{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T08:33:45Z","timestamp":1772786025536,"version":"3.50.1"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T00:00:00Z","timestamp":1722038400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T00:00:00Z","timestamp":1722038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Minufiya University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Pediatric heart surgery is a vital therapeutic option for congenital heart disease, which is one of the most prevalent causes of death in children. Arterial cannulation (AC) and central venous catheter (CVC) are required in pediatric cardiac surgery for continuous monitoring of the central venous pressure (CVP), replacement of fluid or blood products, close hemodynamic monitoring, and frequent sampling for arterial blood gases (ABG). A systematic review and meta-analysis synthesizing evidence from randomized controlled trials (RCTs) retrieved from PubMed, Embase Cochrane, Scopus, and WOS until February 2024. Risk ratio (RR) was used to report dichotomous outcomes, and mean difference (MD) was used to report continuous outcomes, both with a 95% confidence interval (CI) using the random-effects model. Thirteen RCTs with 1060 children were included. Regarding arterial cannulation, the ultrasound-guided technique (US) was associated with a statistically significant increase in successful cannulation [RR: 1.31 with 95% CI (1.10, 1.56), P\u2009&lt;\u20090.0001], and first-attempt success [RR: 1.88 with 95% CI (1.35, 2.63), P\u2009&lt;\u20090.0001]. However, US was not associated with any statistically significant difference in venous cannulation in both outcomes with [RR: 1.13 with 95% CI (0.98, 1.30), P\u2009=\u20090.10], [RR: 1.53 with 95% CI (0.86, 2.71), P\u2009=\u20090.15] respectively. Moreover, US was associated with a statistically significant decrease in the number of attempts either in arterial cannulation with [MD: \u2212\u00a00.73 with 95% CI (\u2212\u00a01.00, \u2212\u00a00.46), P\u2009&lt;\u20090.0001] or in venous cannulation with [MD: \u2212\u00a01.34 with 95% CI (\u2212\u00a02.55, \u2212\u00a00.12), P\u2009=\u20090.03], and the time of attempted cannulation also either in arterial cannulation with [MD: \u2212\u00a02.27 with 95% CI (\u2212\u00a03.38, \u2212\u00a01.16), P\u2009&lt;\u20090.0001] or in venous cannulation with [MD: \u2212\u00a04.13 with 95% CI (\u2212\u00a07.06, \u2212\u00a01.19), P\u2009&lt;\u20090.0001]. US guidance improves successful cannulation rates and first-attempt success in arterial access and reduces the number of attempts and procedural time for arterial and venous access. It was also associated with a lower incidence of complications and procedure failure, particularly in arterial access. However, it was associated with a higher incidence of venous puncture.<\/jats:p>","DOI":"10.1007\/s00246-024-03581-y","type":"journal-article","created":{"date-parts":[[2024,7,27]],"date-time":"2024-07-27T12:01:39Z","timestamp":1722081699000},"page":"1426-1447","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Ultrasound-Guided Versus Palpation-Guided Techniques to Achieve Vascular Access in Children Undergoing Cardiac Surgery: A Systematic Review and Meta-analysis of Randomized Controlled Trials"],"prefix":"10.1007","volume":"46","author":[{"given":"Ahmed A.","family":"Ibrahim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdallah R.","family":"Allam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed Mazen","family":"Amin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed Saad","family":"Rakab","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdulhameed","family":"Alhadeethi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed W.","family":"Hageen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdelrahman","family":"Mahmoud","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Abuelazm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Basel","family":"Abdelazeem","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,27]]},"reference":[{"key":"3581_CR1","doi-asserted-by":"publisher","first-page":"e139","DOI":"10.1161\/CIR.0000000000000757","volume":"141","author":"SS Virani","year":"2020","unstructured":"Virani SS, Alonso A, Benjamin EJ, Bittencourt MS, Callaway CW, Carson AP, Chamberlain AM, Chang AR, American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee (2020) Heart Disease and Stroke Statistics-2020 Update: a report from the American Heart Association. Circulation 141:e139\u2013e596. https:\/\/doi.org\/10.1161\/CIR.0000000000000757","journal-title":"Circulation"},{"key":"3581_CR2","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1097\/PCC.0b013e318250af0c","volume":"13","author":"JA Alten","year":"2012","unstructured":"Alten JA, Borasino S, Gurley WQ, Law MA, Toms R, Dabal RJ (2012) Ultrasound-guided femoral vein catheterization in neonates with cardiac disease. Pediatr Crit Care Med 13:654\u2013659. https:\/\/doi.org\/10.1097\/PCC.0b013e318250af0c","journal-title":"Pediatr Crit Care Med"},{"key":"3581_CR3","doi-asserted-by":"publisher","unstructured":"Aouad-Maroun M, Raphael CK, Sayyid SK, Farah F, Akl EA (2016) Ultrasound-guided arterial cannulation for paediatrics. Cochrane Database Syst Rev 9:CD011364. https:\/\/doi.org\/10.1002\/14651858.CD011364.pub2","DOI":"10.1002\/14651858.CD011364.pub2"},{"key":"3581_CR4","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1213\/ANE.0b013e3182407cd8","volume":"114","author":"CA Troianos","year":"2012","unstructured":"Troianos CA, Hartman GS, Glas KE, Skubas NJ, Eberhardt RT, Walker JD, Reeves ST, Councils on Intraoperative Echocardiography and Vascular Ultrasound of the American Society of Echocardiography, Society of Cardiovascular Anesthesiologists (2012) Special articles: guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society Of Cardiovascular Anesthesiologists. Anesth Analg 114:46\u201372. https:\/\/doi.org\/10.1213\/ANE.0b013e3182407cd8","journal-title":"Anesth Analg"},{"key":"3581_CR5","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1111\/pan.12005","volume":"22","author":"E Schindler","year":"2012","unstructured":"Schindler E, Schears GJ, Hall SR, Yamamoto T (2012) Ultrasound for vascular access in pediatric patients. Paediatr Anaesth 22:1002\u20131007. https:\/\/doi.org\/10.1111\/pan.12005","journal-title":"Paediatr Anaesth"},{"key":"3581_CR6","first-page":"65","volume":"24","author":"R Yaseen","year":"2008","unstructured":"Yaseen R, Memon H (2008) Correlation of femoral artery vs radial artery pressures with central pressure after cardiopulmonary bypass in children. Pakistan J Surg 24:65\u201366","journal-title":"Pakistan J Surg"},{"key":"3581_CR7","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.jped.2017.03.011","volume":"94","author":"HJ Cho","year":"2018","unstructured":"Cho HJ, Lee SH, Jeong IS, Yoon NS, Ma JS, Ahn BH (2018) Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass. J Pediatr (Rio J) 94:76\u201381. https:\/\/doi.org\/10.1016\/j.jped.2017.03.011","journal-title":"J Pediatr (Rio J)"},{"key":"3581_CR8","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1097\/00006565-200008000-00003","volume":"16","author":"VW Chiang","year":"2000","unstructured":"Chiang VW, Baskin MN (2000) Uses and complications of central venous catheters inserted in a pediatric emergency department. Pediatr Emerg Care 16:230\u2013232. https:\/\/doi.org\/10.1097\/00006565-200008000-00003","journal-title":"Pediatr Emerg Care"},{"key":"3581_CR9","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1093\/bja\/aeq123","volume":"105","author":"C Breschan","year":"2010","unstructured":"Breschan C, Platzer M, Jost R, Stettner H, Likar R (2010) Size of internal jugular vs subclavian vein in small infants: an observational, anatomical evaluation with ultrasound. Br J Anaesth 105:179\u2013184. https:\/\/doi.org\/10.1093\/bja\/aeq123","journal-title":"Br J Anaesth"},{"key":"3581_CR10","unstructured":"Shojania KG, Duncan BW, McDonald KM, Wachter RM, Markowitz AJ (2001) Making health care safer: a critical analysis of patient safety practices. Evid Rep Technol Assess (Summ)(43):i\u2013x, 1\u2013668"},{"key":"3581_CR11","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1136\/bmj.327.7411.361","volume":"327","author":"D Hind","year":"2003","unstructured":"Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, Thomas S (2003) Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 327:361. https:\/\/doi.org\/10.1136\/bmj.327.7411.361","journal-title":"BMJ"},{"key":"3581_CR12","doi-asserted-by":"publisher","first-page":"1875","DOI":"10.1097\/01.ccm.0000174483.90346.60","volume":"33","author":"D Feller-Kopman","year":"2005","unstructured":"Feller-Kopman D (2005) Ultrasound-guided central venous catheter placement: the new standard of care? Crit Care Med 33:1875\u20131877. https:\/\/doi.org\/10.1097\/01.ccm.0000174483.90346.60","journal-title":"Crit Care Med"},{"key":"3581_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3310\/hta7120","volume":"7","author":"N Calvert","year":"2003","unstructured":"Calvert N, Hind D, McWilliams RG, Thomas SM, Beverley C, Davidson A (2003) The effectiveness and cost-effectiveness of ultrasound locating devices for central venous access: a systematic review and economic evaluation. Health Technol Assess 7:1\u201384. https:\/\/doi.org\/10.3310\/hta7120","journal-title":"Health Technol Assess"},{"key":"3581_CR14","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1213\/01.ane.0000255289.78333.c2","volume":"104","author":"PL Bailey","year":"2007","unstructured":"Bailey PL, Glance LG, Eaton MP, Parshall B, McIntosh S (2007) A survey of the use of ultrasound during central venous catheterization. Anesth Analg 104:491\u2013497. https:\/\/doi.org\/10.1213\/01.ane.0000255289.78333.c2","journal-title":"Anesth Analg"},{"key":"3581_CR15","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1093\/bja\/aeh134","volume":"92","author":"CR Grebenik","year":"2004","unstructured":"Grebenik CR, Boyce A, Sinclair ME, Evans RD, Mason DG, Martin B (2004) NICE guidelines for central venous catheterization in children. Is the evidence base sufficient? Br J Anaesth 92:827\u2013830. https:\/\/doi.org\/10.1093\/bja\/aeh134","journal-title":"Br J Anaesth"},{"key":"3581_CR16","doi-asserted-by":"publisher","first-page":"2053","DOI":"10.1097\/00003246-199612000-00020","volume":"24","author":"AG Randolph","year":"1996","unstructured":"Randolph AG, Cook DJ, Gonzales CA, Pribble CG (1996) Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med 24:2053\u20132058. https:\/\/doi.org\/10.1097\/00003246-199612000-00020","journal-title":"Crit Care Med"},{"key":"3581_CR17","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.n71","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, Shamseer L, Tetzlaff JM, Akl EA, Brennan SE, Chou R, Glanville J, Grimshaw JM, Hr\u00f3bjartsson A, Lalu MM, Li T, Loder EW, Mayo-Wilson E, McDonald S, McGuinness LA, Stewart LA, Thomas J, Tricco AC, Welch VA, Whiting P, Moher D (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71. https:\/\/doi.org\/10.1136\/bmj.n71","journal-title":"BMJ"},{"key":"3581_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/9781119536604","volume-title":"Cochrane handbook for systematic reviews of interventions","author":"JPT Higgins","year":"2019","unstructured":"Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (2019) Cochrane handbook for systematic reviews of interventions, 1st edn. Wiley, New York","edition":"1"},{"key":"3581_CR19","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.l4898","volume":"366","author":"JAC Sterne","year":"2019","unstructured":"Sterne JAC, Savovi\u0107 J, Page MJ, Elbers RG, Blencowe NS, Boutron I, Cates CJ, Cheng H-Y, Corbett MS, Eldridge SM, Emberson JR, Hern\u00e1n MA, Hopewell S, Hr\u00f3bjartsson A, Junqueira DR, J\u00fcni P, Kirkham JJ, Lasserson T, Li T, McAleenan A, Reeves BC, Shepperd S, Shrier I, Stewart LA, Tilling K, White IR, Whiting PF, Higgins JPT (2019) RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 366:l4898. https:\/\/doi.org\/10.1136\/bmj.l4898","journal-title":"BMJ"},{"key":"3581_CR20","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1136\/bmj.39490.551019.BE","volume":"336","author":"GH Guyatt","year":"2008","unstructured":"Guyatt GH, Oxman AD, Kunz R, Vist GE, Falck-Ytter Y, Sch\u00fcnemann HJ, GRADE Working Group (2008) What is \u201cquality of evidence\u201d and why is it important to clinicians? BMJ 336:995\u2013998. https:\/\/doi.org\/10.1136\/bmj.39490.551019.BE","journal-title":"BMJ"},{"key":"3581_CR21","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1136\/bmj.39489.470347.AD","volume":"336","author":"GH Guyatt","year":"2008","unstructured":"Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, Sch\u00fcnemann HJ, GRADE Working Group (2008) GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ 336:924\u2013926. https:\/\/doi.org\/10.1136\/bmj.39489.470347.AD","journal-title":"BMJ"},{"key":"3581_CR22","doi-asserted-by":"publisher","DOI":"10.14744\/GKDAD.2023.84755","author":"E Aktiz B\u0131\u00e7ak","year":"2023","unstructured":"Aktiz B\u0131\u00e7ak E (2023) Comparison of Ultrasound Guidance Versus Direct Palpation Technique for Central Venous Catheterisation in Children Undergoing Cardiac Surgery. GKDA Derg. https:\/\/doi.org\/10.14744\/GKDAD.2023.84755","journal-title":"GKDA Derg"},{"key":"3581_CR23","doi-asserted-by":"publisher","first-page":"11077","DOI":"10.24875\/CIRU.23000112","volume":"91","author":"E Aktiz-B\u0131\u00e7ak","year":"2023","unstructured":"Aktiz-B\u0131\u00e7ak E, K\u0131l\u0131\u00e7 Y, Elmasta OD, B\u0131\u00e7ak M, Aldudak B, Sal\u0131k F (2023) Comparaci\u00f3n de la t\u00e9cnica de palpaci\u00f3n y gu\u00eda por ultrasonido para el cateterismo de la arteria femoral en ni\u00f1os sometidos a cirug\u00eda card\u00edaca. CIRU 91:11077. https:\/\/doi.org\/10.24875\/CIRU.23000112","journal-title":"CIRU"},{"key":"3581_CR24","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1093\/bja\/70.2.145","volume":"70","author":"PJ Alderson","year":"1993","unstructured":"Alderson PJ, Burrows FA, Stemp LI, Holtby HM (1993) Use of ultrasound to evaluate internal jugular vein anatomy and to facilitate central venous cannulation in paediatric patients. Br J Anaesth 70:145\u2013148. https:\/\/doi.org\/10.1093\/bja\/70.2.145","journal-title":"Br J Anaesth"},{"key":"3581_CR25","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1213\/ANE.0b013e3181e9c475","volume":"111","author":"MT Aouad","year":"2010","unstructured":"Aouad MT, Kanazi GE, Abdallah FW, Moukaddem FH, Turbay MJ, Obeid MY, Siddik-Sayyid SM (2010) Femoral vein cannulation performed by residents: a comparison between ultrasound-guided and landmark technique in infants and children undergoing cardiac surgery. Anesth Analg 111:724\u2013728. https:\/\/doi.org\/10.1213\/ANE.0b013e3181e9c475","journal-title":"Anesth Analg"},{"key":"3581_CR26","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1097\/PCC.0b013e31828a8657","volume":"14","author":"S Ishii","year":"2013","unstructured":"Ishii S, Shime N, Shibasaki M, Sawa T (2013) Ultrasound-Guided Radial Artery Catheterization in Infants and Small Children. Pediatric Critical Care Medicine 14:471\u2013473. https:\/\/doi.org\/10.1097\/PCC.0b013e31828a8657","journal-title":"Pediatric Critical Care Medicine"},{"key":"3581_CR27","doi-asserted-by":"publisher","first-page":"1246","DOI":"10.1007\/s00246-014-0923-5","volume":"35","author":"MA Law","year":"2014","unstructured":"Law MA, Borasino S, McMahon WS, Alten JA (2014) Ultrasound- versus landmark-guided femoral catheterization in the pediatric catheterization laboratory: a randomized-controlled trial. Pediatr Cardiol 35:1246\u20131252. https:\/\/doi.org\/10.1007\/s00246-014-0923-5","journal-title":"Pediatr Cardiol"},{"key":"3581_CR28","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1097\/EJA.0000000000000926","volume":"36","author":"JJ Min","year":"2019","unstructured":"Min JJ, Tay CK, Gil N-S, Lee J-H, Kim S, Kim CS, Yang J-H, Jun T-G (2019) Ultrasound-guided vs. palpation-guided techniques for radial arterial catheterisation in infants: a randomised controlled trial. Eur J Anaesthesiol 36:200\u2013205. https:\/\/doi.org\/10.1097\/EJA.0000000000000926","journal-title":"Eur J Anaesthesiol"},{"key":"3581_CR29","first-page":"55","volume":"24","author":"A Sadeghi","year":"2023","unstructured":"Sadeghi A, Ziyaeifard M, Azarfarin R, Rastravan R, Totonchi Z, Hydarpour E (2023) Comparison between central venous catheter placement and ultrasound guide and anatomical landmarks in pediatric patients undergoing cardiac surgeries. Iran Heart J 24:55\u201361","journal-title":"Iran Heart J"},{"key":"3581_CR30","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1177\/11297298211023307","volume":"24","author":"F Sal\u0131k","year":"2023","unstructured":"Sal\u0131k F, B\u0131\u00e7ak M (2023) Comparison of ultrasound-guided femoral artery cannulation versus palpation technique in neonates undergoing cardiac surgery. J Vasc Access 24:27\u201334. https:\/\/doi.org\/10.1177\/11297298211023307","journal-title":"J Vasc Access"},{"key":"3581_CR31","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1111\/pan.12935","volume":"26","author":"SM Siddik-Sayyid","year":"2016","unstructured":"Siddik-Sayyid SM, Aouad MT, Ibrahim MH, Taha SK, Nawfal MF, Tfaili YJ, Kaddoum RN (2016) Femoral arterial cannulation performed by residents: a comparison between ultrasound-guided and palpation technique in infants and children undergoing cardiac surgery. Pediatr Anesth 26:823\u2013830. https:\/\/doi.org\/10.1111\/pan.12935","journal-title":"Pediatr Anesth"},{"key":"3581_CR32","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/00000542-199907000-00013","volume":"91","author":"ST Verghese","year":"1999","unstructured":"Verghese ST, McGill WA, Patel RI, Sell JE, Midgley FM, Ruttimann UE (1999) Ultrasound-guided internal jugular venous cannulation in infants: a prospective comparison with the traditional palpation method. Anesthesiology 91:71\u201377. https:\/\/doi.org\/10.1097\/00000542-199907000-00013","journal-title":"Anesthesiology"},{"key":"3581_CR33","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1046\/j.1460-9592.2000.00554.x","volume":"10","author":"ST Verghese","year":"2000","unstructured":"Verghese ST, McGill WA, Patel RI, Sell JE, Midgley FM, Ruttimann UE (2000) Comparison of three techniques for internal jugular vein cannulation in infants. Paediatr Anaesth 10:505\u2013511. https:\/\/doi.org\/10.1046\/j.1460-9592.2000.00554.x","journal-title":"Paediatr Anaesth"},{"key":"3581_CR34","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1017\/S0265021506000275","volume":"23","author":"U Schwemmer","year":"2006","unstructured":"Schwemmer U, Arzet HA, Trautner H, Rauch S, Roewer N, Greim C-A (2006) Ultrasound-guided arterial cannulation in infants improves success rate. Eur J Anaesthesiol 23:476\u2013480. https:\/\/doi.org\/10.1017\/S0265021506000275","journal-title":"Eur J Anaesthesiol"},{"key":"3581_CR35","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1097\/01.CCM.0000050452.17304.2F","volume":"31","author":"PD Levin","year":"2003","unstructured":"Levin PD, Sheinin O, Gozal Y (2003) Use of ultrasound guidance in the insertion of radial artery catheters. Crit Care Med 31:481\u2013484. https:\/\/doi.org\/10.1097\/01.CCM.0000050452.17304.2F","journal-title":"Crit Care Med"},{"key":"3581_CR36","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1378\/chest.10-0919","volume":"139","author":"AL Shiloh","year":"2011","unstructured":"Shiloh AL, Savel RH, Paulin LM, Eisen LA (2011) Ultrasound-guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trials. Chest 139:524\u2013529. https:\/\/doi.org\/10.1378\/chest.10-0919","journal-title":"Chest"},{"key":"3581_CR37","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1197\/j.aem.2006.07.015","volume":"13","author":"S Shiver","year":"2006","unstructured":"Shiver S, Blaivas M, Lyon M (2006) A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters. Acad Emerg Med 13:1275\u20131279. https:\/\/doi.org\/10.1197\/j.aem.2006.07.015","journal-title":"Acad Emerg Med"},{"key":"3581_CR38","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s10877-014-9585-3","volume":"29","author":"H Dolu","year":"2015","unstructured":"Dolu H, Goksu S, Sahin L, Ozen O, Eken L (2015) Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation. J Clin Monit Comput 29:177\u2013182. https:\/\/doi.org\/10.1007\/s10877-014-9585-3","journal-title":"J Clin Monit Comput"},{"key":"3581_CR39","doi-asserted-by":"publisher","first-page":"1813","DOI":"10.4187\/respcare.02905","volume":"59","author":"AG Miller","year":"2014","unstructured":"Miller AG, Cappiello JL, Gentile MA, Almond AM, Thalman JJ, MacIntyre NR (2014) Analysis of radial artery catheter placement by respiratory therapists using ultrasound guidance. Respir Care 59:1813\u20131816. https:\/\/doi.org\/10.4187\/respcare.02905","journal-title":"Respir Care"},{"key":"3581_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ahj.2018.06.007","volume":"204","author":"H Moussa Pacha","year":"2018","unstructured":"Moussa Pacha H, Alahdab F, Al-Khadra Y, Idris A, Rabbat F, Darmoch F, Soud M, Zaitoun A, Kaki A, Rao SV, Kwok CS, Mamas MA, Alraies MC (2018) Ultrasound-guided versus palpation-guided radial artery catheterization in adult population: A systematic review and meta-analysis of randomized controlled trials. Am Heart J 204:1\u20138. https:\/\/doi.org\/10.1016\/j.ahj.2018.06.007","journal-title":"Am Heart J"},{"key":"3581_CR41","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.ajem.2014.10.008","volume":"33","author":"Y-B Gao","year":"2015","unstructured":"Gao Y-B, Yan J-H, Gao F-Q, Pan L, Wang X-Z, Lv C-J (2015) Effects of ultrasound-guided radial artery catheterization: an updated meta-analysis. Am J Emerg Med 33:50\u201355. https:\/\/doi.org\/10.1016\/j.ajem.2014.10.008","journal-title":"Am J Emerg Med"},{"key":"3581_CR42","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1002\/ca.22768","volume":"30","author":"T Hoffman","year":"2017","unstructured":"Hoffman T, Du Plessis M, Prekupec MP, Gielecki J, Zurada A, Tubbs RS, Loukas M (2017) Ultrasound-guided central venous catheterization: A review of the relevant anatomy, technique, complications, and anatomical variations. Clin Anat 30:237\u2013250. https:\/\/doi.org\/10.1002\/ca.22768","journal-title":"Clin Anat"},{"key":"3581_CR43","doi-asserted-by":"publisher","first-page":"383","DOI":"10.4187\/respcare.04190","volume":"61","author":"AG Miller","year":"2016","unstructured":"Miller AG, Bardin AJ (2016) Review of Ultrasound-Guided Radial Artery Catheter Placement. Respir Care 61:383\u2013388. https:\/\/doi.org\/10.4187\/respcare.04190","journal-title":"Respir Care"},{"key":"3581_CR44","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1378\/chest.15-1784","volume":"149","author":"W-J Gu","year":"2016","unstructured":"Gu W-J, Wu X-D, Wang F, Ma Z-L, Gu X-P (2016) Ultrasound Guidance Facilitates Radial Artery Catheterization: A Meta-analysis With Trial Sequential Analysis of Randomized Controlled Trials. Chest 149:166\u2013179. https:\/\/doi.org\/10.1378\/chest.15-1784","journal-title":"Chest"},{"key":"3581_CR45","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0111527","volume":"9","author":"L Tang","year":"2014","unstructured":"Tang L, Wang F, Li Y, Zhao L, Xi H, Guo Z, Li X, Gao C, Wang J, Zhou L (2014) Ultrasound guidance for radial artery catheterization: an updated meta-analysis of randomized controlled trials. PLoS ONE 9:e111527. https:\/\/doi.org\/10.1371\/journal.pone.0111527","journal-title":"PLoS ONE"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-024-03581-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00246-024-03581-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-024-03581-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T20:25:56Z","timestamp":1757103956000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00246-024-03581-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,27]]},"references-count":45,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["3581"],"URL":"https:\/\/doi.org\/10.1007\/s00246-024-03581-y","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,27]]},"assertion":[{"value":"19 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}}]}}