{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T23:41:34Z","timestamp":1769125294116,"version":"3.49.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T00:00:00Z","timestamp":1740096000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T00:00:00Z","timestamp":1740096000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2026,1]]},"DOI":"10.1007\/s00246-025-03801-z","type":"journal-article","created":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T17:50:19Z","timestamp":1740160219000},"page":"462-466","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Leadless Pacemaker Implantation in an Adolescent with Durable LVAD Support"],"prefix":"10.1007","volume":"47","author":[{"given":"Taylor S.","family":"Howard","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael A.","family":"Bruno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hari","family":"Tunuguntla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward J.","family":"Hickey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santiago O.","family":"Valdes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina Y.","family":"Miyake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Seger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,2,21]]},"reference":[{"issue":"6","key":"3801_CR1","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1056\/NEJMoa1511643","volume":"374","author":"D Reynolds","year":"2016","unstructured":"Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S, Narasimhan C, Steinwender C, Brugada J, Lloyd M, Roberts PR, Sagi V, Hummel J, Bongiorni MG, Knops RE, Ellis CR, Gornick CC, Bernabei MA, Laager V, Stromberg K, Williams ER, Hudnall JH, Ritter P et al (2016) A leadless intracardiac transcatheter pacing system. N Engl J Med. 374(6):533\u2013541","journal-title":"N Engl J Med."},{"issue":"9","key":"3801_CR2","doi-asserted-by":"publisher","first-page":"1048","DOI":"10.1111\/pace.13937","volume":"43","author":"AM Parker","year":"2020","unstructured":"Parker AM, Vilaro JR, Aranda JM Jr, Al-Ani M, George P Jr, Ahmed MM (2020) Leadless pacemaker use in a patient with a durable left ventricular assist device. Pacing Clin Electrophysiol 43(9):1048\u20131050. https:\/\/doi.org\/10.1111\/pace.13937. (Epub 2020 May 27 PMID: 32394443)","journal-title":"Pacing Clin Electrophysiol"},{"key":"3801_CR3","doi-asserted-by":"publisher","first-page":"1126","DOI":"10.1111\/pace.14182","volume":"44","author":"Y Miyazaki","year":"2021","unstructured":"Miyazaki Y, Wada M, Yoshitake K et al (2021) Leadless pacemaker implantation in a patient with a fully magnetically levitated left ventricular assist device. Pacing Clin Electrophysiol 44:1126\u20131129","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"3801_CR4","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.hrcr.2022.10.005","volume":"9","author":"K Kawase","year":"2022","unstructured":"Kawase K, Yamagata K, Ishibashi K, Fukushima N, Kusano K (2022) Leadless pacemaker interrogation interference after conversion of a left ventricular assist device. HeartRhythm Case Rep 9(1):25\u201327","journal-title":"HeartRhythm Case Rep"},{"issue":"11","key":"3801_CR5","doi-asserted-by":"publisher","first-page":"1888","DOI":"10.1016\/j.hrthm.2021.07.038","volume":"18","author":"MJ Shah","year":"2021","unstructured":"Shah MJ, Silka MJ, Silva JNA, Balaji S, Beach CM, Benjamin MN, Berul CI, Cannon B, Cecchin F, Cohen MI, Dalal AS, Dechert BE, Foster A, Gebauer R, Gonzalez Corcia MC, Kannankeril PJ, Karpawich PP, Kim JJ, Krishna MR, Kubu\u0161 P, LaPage MJ, Mah DY, Malloy-Walton L, Miyazaki A, Motonaga KS, Niu MC, Olen M, Paul T, Rosenthal E, Saarel EV, Silvetti MS, Stephenson EA, Tan RB, Triedman J, Bergen NHV, Wackel PL (2021) 2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients. Heart Rhythm 18(11):1888\u20131924","journal-title":"Heart Rhythm"},{"issue":"12","key":"3801_CR6","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1016\/j.jchf.2017.08.014","volume":"5","author":"KJ Clerkin","year":"2017","unstructured":"Clerkin KJ, Topkara VK, Demmer RT, Dizon JM, Yuzefpolskaya M, Fried JA, Mai X, Mancini DM, Takeda K, Takayama H, Naka Y, Colombo PC, Garan AR (2017) Implantable cardioverter-defibrillators in patients with a continuous-flow left ventricular assist device: an analysis of the INTERMACS registry. JACC Heart Fail 5(12):916\u2013926","journal-title":"JACC Heart Fail"},{"issue":"20","key":"3801_CR7","doi-asserted-by":"publisher","first-page":"e967","DOI":"10.1161\/CIR.0000000000000673","volume":"139","author":"R Gopinathannair","year":"2019","unstructured":"Gopinathannair R, Cornwell WK, Dukes JW, Ellis CR, Hickey KT, Joglar JA, Pagani FD, Roukoz H, Slaughter MS, Patton KK (2019) Device therapy and arrhythmia management in left ventricular assist device recipients: a scientific statement from the American Heart Association. Circulation 139(20):e967\u2013e989","journal-title":"Circulation"},{"issue":"400","key":"3801_CR8","doi-asserted-by":"publisher","first-page":"131807","DOI":"10.1016\/j.ijcard.2024.131807","volume":"1","author":"F Migliore","year":"2024","unstructured":"Migliore F, Schiavone M, Pittorru R, Forleo GB, De Lazzari M, Mitacchione G, Biffi M, Gulletta S, Kuschyk J, Dall\u2019Aglio PB, Rovaris G, Tilz R, Mastro FR, Iliceto S, Tondo C, Di Biase L, Gasperetti A, Tarzia V, Gerosa G (2024) Left ventricular assist device in the presence of subcutaneous implantable cardioverter defibrillator: data from a multicenter experience. Int J Cardiol 1(400):131807","journal-title":"Int J Cardiol"},{"key":"3801_CR9","doi-asserted-by":"publisher","unstructured":"Mitacchione G, Migliore F (2024) Co-presence of subcutaneous implantable cardioverter-defibrillator and leadless pacemaker in high-risk infection patients: are we out of the woods? J Interv Card Electrophysiol. https:\/\/doi.org\/10.1007\/s10840-023-01726-2. Epub ahead of print.","DOI":"10.1007\/s10840-023-01726-2"},{"issue":"14","key":"3801_CR10","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1093\/eurheartj\/ehae101","volume":"45","author":"MF El-Chami","year":"2024","unstructured":"El-Chami MF, Garweg C, Clementy N, Al-Samadi F, Iacopino S, Martinez-Sande JL, Roberts PR, Tondo C, Johansen JB, Vinolas-Prat X, Cha YM, Grubman E, Bordachar P, Stromberg K, Fagan DH, Piccini JP (2024) Leadless pacemakers at 5-year follow-up: the Micra transcatheter pacing system post-approval registry. Eur Heart J 45(14):1241\u20131251","journal-title":"Eur Heart J"},{"issue":"2","key":"3801_CR11","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1111\/jce.15343","volume":"33","author":"RG Hauser","year":"2022","unstructured":"Hauser RG, Gornick CC, Abdelhadi RH, Tang CY, Kapphahn-Bergs M, Casey SA, Okeson BK, Steele EA, Sengupta JD (2022) Leadless pacemaker perforations: clinical consequences and related device and user problems. J Cardiovasc Electrophysiol 33(2):154\u2013159","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"4","key":"3801_CR12","doi-asserted-by":"publisher","first-page":"e011447","DOI":"10.1161\/CIRCEP.122.011447","volume":"16","author":"MJ Shah","year":"2023","unstructured":"Shah MJ, Borquez AA, Cortez D, McCanta AC, De Filippo P, Whitehill RD, Imundo JR, Moore JP, Sherwin ED, Howard TS, Rosenthal E, Kertesz NJ, Chang PM, Madan N, Kutalek SP, Hammond BH, Janson CM, Ramesh Iyer V, Williams MR (2023) transcatheter leadless pacing in children: a PACES collaborative study in the real-world setting. Circ Arrhythm Electrophysiol 16(4):e011447","journal-title":"Circ Arrhythm Electrophysiol"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-025-03801-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00246-025-03801-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-025-03801-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T06:42:52Z","timestamp":1769064172000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00246-025-03801-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,21]]},"references-count":12,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["3801"],"URL":"https:\/\/doi.org\/10.1007\/s00246-025-03801-z","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,21]]},"assertion":[{"value":"10 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Author John Seger, MD has a consulting relationship with Medtronic related to training on cardiac rhythm products..  He did participate in the implant procedure, but did not participate in the decision of what type of device was going to be utilized in this particular patient.    All other authors have no disclosures.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}