{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T16:11:52Z","timestamp":1777997512774,"version":"3.51.4"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T00:00:00Z","timestamp":1754006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T00:00:00Z","timestamp":1754006400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1007\/s00246-025-03978-3","type":"journal-article","created":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T11:12:54Z","timestamp":1754046774000},"page":"1925-1932","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Characteristics and Success of Intentional Stent Fracture in Drug-Eluting Coronary Stents for Use in Congenital Heart Disease"],"prefix":"10.1007","volume":"47","author":[{"given":"Samuel N.","family":"DeSantis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew A.","family":"Crystal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver M.","family":"Barry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,8,1]]},"reference":[{"issue":"6","key":"3978_CR1","doi-asserted-by":"publisher","first-page":"1923","DOI":"10.1161\/01.cir.83.6.1923","volume":"83","author":"MP O'Laughlin","year":"1991","unstructured":"O\u2019Laughlin MP, Perry SB, Lock JE, Mullins CE (1991) Use of endovascular stents in congenital heart disease. Circulation 83(6):1923\u20131939. https:\/\/doi.org\/10.1161\/01.cir.83.6.1923","journal-title":"Circulation"},{"issue":"8","key":"3978_CR2","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1136\/heart.89.8.905","volume":"89","author":"C Duke","year":"2003","unstructured":"Duke C, Rosenthal E, Qureshi SA (2003) The efficacy and safety of stent redilatation in congenital heart disease. Heart 89(8):905\u2013912. https:\/\/doi.org\/10.1136\/heart.89.8.905","journal-title":"Heart"},{"issue":"4","key":"3978_CR3","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.115.003281","volume":"9","author":"BH Morray","year":"2016","unstructured":"Morray BH, McElhinney DB, Marshall AC, Porras D (2016) Intentional fracture of maximally dilated balloon-expandable pulmonary artery stents using ultra-high-pressure balloon angioplasty: a preliminary analysis. Circ Cardiovasc Interv 9(4):e003281. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.115.003281","journal-title":"Circ Cardiovasc Interv"},{"issue":"5","key":"3978_CR4","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1161\/CIRCINTERVENTIONS.113.000148","volume":"6","author":"DB McElhinney","year":"2013","unstructured":"McElhinney DB, Marshall AC, Schievano S (2013) Fracture of cardiovascular stents in patients with congenital heart disease: theoretical and empirical considerations. Circ Cardiovasc Interv 6(5):575\u2013585. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.113.000148","journal-title":"Circ Cardiovasc Interv"},{"issue":"6","key":"3978_CR5","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1111\/chd.12399","volume":"11","author":"S Danon","year":"2016","unstructured":"Danon S, Gray RG, Crystal MA et al (2016) Expansion characteristics of stents used in congenital heart disease: serial dilation offers improved expansion potential compared to direct dilation: results from a Pediatric Interventional Cardiology Early Career Society (PICES) Investigation. Congenit Heart Dis 11(6):741\u2013750. https:\/\/doi.org\/10.1111\/chd.12399","journal-title":"Congenit Heart Dis"},{"issue":"1","key":"3978_CR6","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1007\/s00246-017-1736-0","volume":"39","author":"MA Crystal","year":"2018","unstructured":"Crystal MA, Morgan GJ, Danon S et al (2018) Serial versus direct dilation of small diameter stents results in a more predictable and complete intentional transcatheter stent fracture: A PICES bench testing study. Pediatr Cardiol 39(1):120\u2013128. https:\/\/doi.org\/10.1007\/s00246-017-1736-0","journal-title":"Pediatr Cardiol"},{"issue":"1","key":"3978_CR7","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1002\/ccd.31309","volume":"105","author":"K Gendera","year":"2025","unstructured":"Gendera K, Bambul Heck P, Eicken A et al (2025) Serial dilation and intentional fracturing of stents in congenital heart disease\u2014benchside tests and initial clinical results. Catheter Cardiovasc Interv 105(1):150\u2013157. https:\/\/doi.org\/10.1002\/ccd.31309","journal-title":"Catheter Cardiovasc Interv"},{"issue":"6","key":"3978_CR8","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1016\/j.amjcard.2019.06.014","volume":"124","author":"V Aggarwal","year":"2019","unstructured":"Aggarwal V, Dhillon GS, Penny DJ, Gowda ST, Qureshi AM (2019) Drug-eluting stents compared with bare metal stents for stenting the ductus arteriosus in infants with ductal-dependent pulmonary blood flow. Am J Cardiol 124(6):952\u2013959. https:\/\/doi.org\/10.1016\/j.amjcard.2019.06.014","journal-title":"Am J Cardiol"},{"issue":"2","key":"3978_CR9","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1002\/ccd.28328","volume":"94","author":"A Khan","year":"2019","unstructured":"Khan A, Qureshi AM, Justino H (2019) Comparison of drug-eluting versus bare-metal stents for pulmonary vein stenosis in childhood. Catheter Cardiovasc Interv 94(2):233\u2013242. https:\/\/doi.org\/10.1002\/ccd.28328","journal-title":"Catheter Cardiovasc Interv"},{"key":"3978_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jscai.2024.101574","author":"M Gupta","year":"2024","unstructured":"Gupta M, Callahan RM, Leeth EB, Silvestro E (2024) B-7 | balloon dilation technique influences stent shortening and intentional stent fracture during over-expansion of drug-eluting stents: a bench testing study. J Soc Cardiovasc Angiograph Interventions. https:\/\/doi.org\/10.1016\/j.jscai.2024.101574","journal-title":"J Soc Cardiovasc Angiograph Interventions"},{"issue":"3","key":"3978_CR11","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1007\/s12325-010-0022-9","volume":"27","author":"IBA Menown","year":"2010","unstructured":"Menown IBA, Noad R, Garcia EJ, Meredith I (2010) The platinum chromium element stent platform: from alloy, to design, to clinical practice. Adv Ther 27(3):129\u2013141. https:\/\/doi.org\/10.1007\/s12325-010-0022-9","journal-title":"Adv Ther"},{"key":"3978_CR12","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12216711","author":"P Brami","year":"2023","unstructured":"Brami P, Fischer Q, Pham V, Seret G, Varenne O, Picard F (2023) Evolution of coronary stent platforms: a brief overview of currently used drug-eluting stents. J Clin Med. https:\/\/doi.org\/10.3390\/jcm12216711","journal-title":"J Clin Med"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-025-03978-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00246-025-03978-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-025-03978-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T15:17:16Z","timestamp":1777994236000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00246-025-03978-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,1]]},"references-count":12,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["3978"],"URL":"https:\/\/doi.org\/10.1007\/s00246-025-03978-3","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-6900435\/v1","asserted-by":"object"}]},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,1]]},"assertion":[{"value":"15 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors report no financial relationships or conflicts of interest regarding the content herein.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}