{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T16:15:54Z","timestamp":1787328954536,"version":"build-2736575974"},"reference-count":3,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T00:00:00Z","timestamp":1759017600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T00:00:00Z","timestamp":1759017600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s00246-025-04036-8","type":"journal-article","created":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T16:51:55Z","timestamp":1759078315000},"page":"2762-2764","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Self-expandable Venus P-valve in Patient with Transposition of Great Arteries and Arterial Switch Operation"],"prefix":"10.1007","volume":"47","author":[{"given":"St\u00e9phanie","family":"Douchin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helene","family":"Bouvaist","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastien","family":"Hascoet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phuoc","family":"Duong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alain","family":"Fraisse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,28]]},"reference":[{"key":"4036_CR1","first-page":"359","volume":"103","author":"Q Jin","year":"2024","unstructured":"Jin Q, Long Y, Zhang G et al (2024) Five-year follow-up after percutaneous pulmonary valve implantation using the Venus P-valve system for patients with pulmonary regurgitation and an enlarged native right ventricular outflow tract. Catheter Cardiovasc Interv 103:359\u2013366","journal-title":"Catheter Cardiovasc Interv"},{"issue":"13","key":"4036_CR2","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.4244\/EIJ-D-18-00299","volume":"14","author":"G Morgan","year":"2019","unstructured":"Morgan G, Prachasilchai P, Promphan W et al (2019) Medium-term results of percutaneous pulmonary valve implantation using the Venus P-valve: international experience. EuroIntervention 14(13):1363\u20131370","journal-title":"EuroIntervention"},{"key":"4036_CR3","first-page":"531","volume":"104","author":"S Nageotte","year":"2024","unstructured":"Nageotte S, Salavitabar A, Zablah JE et al (2024) Transcatheter pulmonary valve replacement after arterial switch operation. Catheter Cardiovasc Interv 104:531\u2013539","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-025-04036-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00246-025-04036-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-025-04036-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T15:07:38Z","timestamp":1787324858000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00246-025-04036-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,28]]},"references-count":3,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["4036"],"URL":"https:\/\/doi.org\/10.1007\/s00246-025-04036-8","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,28]]},"assertion":[{"value":"18 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Alain Fraisse is consultant and proctor for Medtronic, Occlutech Inc, Meril, ICardiology, Venus Medtech and Abbott Inc. Other authors have no conflict of interest.","order":1,"name":"Ethics","label":"Competing Interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}