{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T11:27:17Z","timestamp":1786966037520,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"DOI":"10.1007\/s00246-026-04421-x","type":"journal-article","created":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T11:03:39Z","timestamp":1786964619000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Transcatheter Pulmonary Valve Replacement in Dysfunctional Valved Polytetrafluoroethylene (PTFE) Right Ventricular Outflow Tract Conduits"],"prefix":"10.1007","author":[{"given":"Alexandra A.","family":"Erdmann MD","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos E.","family":"Diaz-Castrillon MD, MS","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara M.","family":"Trucco MD","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan H.","family":"Goldstein MD","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor O.","family":"Morell MD","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacqueline","family":"Kreutzer MD","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,17]]},"reference":[{"issue":"6","key":"4421_CR1","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1161\/CIRCINTERVENTIONS.112.000073","volume":"6","author":"MR Hainstock","year":"2013","unstructured":"Hainstock MR, Marshall AC, Lock JE, McElhinney DB (2013) Angioplasty of obstructed homograft conduits in the right ventricular outflow tract with ultra-noncompliant balloons. Circ Cardiovasc Interv 6(6):671\u2013679. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.112.000073","journal-title":"Circ Cardiovasc Interv"},{"issue":"6","key":"4421_CR2","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1002\/ccd.22400","volume":"75","author":"SC Brown","year":"2010","unstructured":"Brown SC, Boshoff DE, Heying R et al (2010) Stent expansion of stretch Gore-Tex grafts in children with congenital heart lesions. Catheter Cardiovasc Interv 75(6):843\u2013848. https:\/\/doi.org\/10.1002\/ccd.22400","journal-title":"Catheter Cardiovasc Interv"},{"issue":"11","key":"4421_CR3","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1161\/01.CIR.92.11.3282","volume":"92","author":"AJ Powell","year":"1995","unstructured":"Powell AJ, Lock JE, Keane JF, Perry SB (1995) Prolongation of RV-PA conduit life span by percutaneous stent implantation. Circulation 92(11):3282\u20133288. https:\/\/doi.org\/10.1161\/01.CIR.92.11.3282","journal-title":"Circulation"},{"issue":"22","key":"4421_CR4","doi-asserted-by":"publisher","first-page":"2598","DOI":"10.1161\/CIRCULATIONAHA.105.607127","volume":"113","author":"LF Peng","year":"2006","unstructured":"Peng LF, McElhinney DB, Nugent AW et al (2006) Endovascular stenting of obstructed right ventricle\u2013to\u2013pulmonary artery conduits. Circulation 113(22):2598\u20132605. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.105.607127","journal-title":"Circulation"},{"key":"4421_CR5","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.118.006598","author":"JW Delaney","year":"2018","unstructured":"Delaney JW, Goldstein BH, Bishnoi RN et al (2018) Covered CP stent for treatment of right ventricular conduit injury during Melody transcatheter pulmonary valve replacement. Circ Cardiovasc Interv. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.118.006598","journal-title":"Circ Cardiovasc Interv"},{"issue":"1","key":"4421_CR6","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/S0003-4975(00)01788-4","volume":"71","author":"JM Forbess","year":"2001","unstructured":"Forbess JM, Shah AS, St. Louis JD, Jaggers JJ, Ungerleider RM (2001) Cryopreserved homografts in the pulmonary position: determinants of durability. Ann Thorac Surg 71(1):54\u201359. https:\/\/doi.org\/10.1016\/S0003-4975(00)01788-4","journal-title":"Ann Thorac Surg"},{"key":"4421_CR7","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2021.719840","volume":"8","author":"T Qian","year":"2021","unstructured":"Qian T, Yuan H, Chen C et al (2021) Conduits for right ventricular outflow tract reconstruction in infants and young children. Front Surg 8:719840. https:\/\/doi.org\/10.3389\/fsurg.2021.719840","journal-title":"Front Surg"},{"issue":"5","key":"4421_CR8","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1016\/j.jtcvs.2006.12.045","volume":"133","author":"JW Brown","year":"2007","unstructured":"Brown JW, Ruzmetov M, Vijay P, Rodefeld MD, Turrentine MW (2007) Right ventricular outflow tract reconstruction with a polytetrafluoroethylene monocusp valve: A twelve-year experience. J Thorac Cardiovasc Surg 133(5):1336\u20131343. https:\/\/doi.org\/10.1016\/j.jtcvs.2006.12.045","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"4421_CR9","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.jtcvs.2008.08.060","volume":"137","author":"M Ando","year":"2009","unstructured":"Ando M, Takahashi Y (2009) Ten-year experience with handmade trileaflet polytetrafluoroethylene valved conduit used for pulmonary reconstruction. J Thorac Cardiovasc Surg 137(1):124\u2013131. https:\/\/doi.org\/10.1016\/j.jtcvs.2008.08.060","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"4421_CR10","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1177\/21501351221120411","volume":"14","author":"CH Tan","year":"2023","unstructured":"Tan CH, Cleveland DC, Dabal RJ et al (2023) Association between venous homografts and allosensitization after norwood procedure. World J Pediatr Congenit Heart Surg 14(1):25\u201330. https:\/\/doi.org\/10.1177\/21501351221120411","journal-title":"World J Pediatr Congenit Heart Surg"},{"issue":"5","key":"4421_CR11","doi-asserted-by":"publisher","first-page":"2082","DOI":"10.1016\/j.jtcvs.2017.11.107","volume":"155","author":"CW Mercer","year":"2018","unstructured":"Mercer CW, West SC, Sharma MS, Yoshida M, Morell VO (2018) Polytetrafluoroethylene conduits versus homografts for right ventricular outflow tract reconstruction in infants and young children: An institutional experience. J Thorac Cardiovasc Surg 155(5):2082\u20132091e1. https:\/\/doi.org\/10.1016\/j.jtcvs.2017.11.107","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"4421_CR12","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1177\/2150135119888141","volume":"11","author":"LM Seese","year":"2020","unstructured":"Seese LM, Turbendian HK, Castrillon CED, Morell VO (2020) The fate of homograft versus polytetrafluoroethylene conduits after neonatal truncus arteriosus repair. World J Pediatr Congenit Heart Surg 11(2):141\u2013147. https:\/\/doi.org\/10.1177\/2150135119888141","journal-title":"World J Pediatr Congenit Heart Surg"},{"key":"4421_CR13","doi-asserted-by":"publisher","unstructured":"Diaz-Castrillon CE, Castro-Medina M, Viegas M et al (2022) Anatomic position and durability of polytetrafluoroethylene conduit\u2009\u2265\u200918\u00a0mm: single-center experience. Ann Thorac Surg. https:\/\/doi.org\/10.1016\/j.athoracsur.2022.08.013","DOI":"10.1016\/j.athoracsur.2022.08.013"},{"key":"4421_CR14","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000001291","author":"T Geva","year":"2024","unstructured":"Geva T, Wald RM, Bucholz E et al (2024) Long-term management of right ventricular outflow tract dysfunction in repaired tetralogy of Fallot: a scientific statement from the American Heart Association. Circulation. https:\/\/doi.org\/10.1161\/CIR.0000000000001291","journal-title":"Circulation"},{"issue":"3","key":"4421_CR15","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1016\/j.athoracsur.2015.04.108","volume":"100","author":"MJ Gillespie","year":"2015","unstructured":"Gillespie MJ, McElhinney DB, Kreutzer J et al (2015) Transcatheter pulmonary valve replacement for right ventricular outflow tract conduit dysfunction after the ross procedure. Ann Thorac Surg 100(3):996\u20131003. https:\/\/doi.org\/10.1016\/j.athoracsur.2015.04.108","journal-title":"Ann Thorac Surg"},{"issue":"4","key":"4421_CR16","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1016\/j.athoracsur.2010.11.010","volume":"91","author":"M Yoshida","year":"2011","unstructured":"Yoshida M, Wearden PD, Dur O, Pekkan K, Morell VO (2011) Right ventricular outflow tract reconstruction with bicuspid valved polytetrafluoroethylene conduit. Ann Thorac Surg 91(4):1235\u20131239. https:\/\/doi.org\/10.1016\/j.athoracsur.2010.11.010","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"4421_CR17","doi-asserted-by":"publisher","first-page":"e455","DOI":"10.1016\/j.athoracsur.2020.11.090","volume":"111","author":"GN Coyan","year":"2021","unstructured":"Coyan GN, Da Fonseca Da Silva L, Da Silva JP, Viegas M, Morell VO, Castro-Medina M (2021) Polytetrafluoroethylene tricuspid valved conduit for right ventricular outflow tract reconstruction. Ann Thorac Surg 111(6):e455\u2013e458. https:\/\/doi.org\/10.1016\/j.athoracsur.2020.11.090","journal-title":"Ann Thorac Surg"},{"key":"4421_CR18","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.amjcard.2024.06.026","volume":"226","author":"EC D\u2019Angelo","year":"2024","unstructured":"D\u2019Angelo EC, Egidy Assenza G, Balducci A et al (2024) Performance and failure of right ventricle to pulmonary artery conduit in congenital heart disease. Am J Cardiol 226:50\u201358. https:\/\/doi.org\/10.1016\/j.amjcard.2024.06.026","journal-title":"Am J Cardiol"},{"issue":"Supplement 3","key":"4421_CR19","doi-asserted-by":"publisher","first-page":"III-130","DOI":"10.1161\/01.CIR.102.suppl_3.III-130","volume":"102","author":"JS Tweddell","year":"2000","unstructured":"Tweddell JS, Pelech AN, Frommelt PC et al (2000) Factors affecting longevity of homograft valves used in right ventricular outflow tract reconstruction for congenital heart disease. Circulation 102(Supplement 3):III-130\u2013III&#x02212;135. https:\/\/doi.org\/10.1161\/01.CIR.102.suppl_3.III-130","journal-title":"Circulation"},{"issue":"3","key":"4421_CR20","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.ejcts.2010.01.063","volume":"38","author":"AC Fiore","year":"2010","unstructured":"Fiore AC, Ruzmetov M, Huynh D et al (2010) Comparison of bovine jugular vein with pulmonary homograft conduits in children less than 2 years of age. Eur J Cardio-Thorac Surg 38(3):318\u2013325. https:\/\/doi.org\/10.1016\/j.ejcts.2010.01.063","journal-title":"Eur J Cardio-Thorac Surg"},{"issue":"4","key":"4421_CR21","first-page":"478","volume":"24","author":"M Ruzmetov","year":"2015","unstructured":"Ruzmetov M, Geiss DM, Shah JJ, Fortuna RS, Welke KF (2015) Does the homograft for RVOT reconstruction in ross: patients fare better than for non-ross patients? A single-center experience. J Heart Valve Dis 24(4):478\u2013483","journal-title":"J Heart Valve Dis"},{"issue":"01","key":"4421_CR22","doi-asserted-by":"publisher","first-page":"025","DOI":"10.1055\/s-0035-1554962","volume":"64","author":"E Sandica","year":"2015","unstructured":"Sandica E, Boethig D, Blanz U et al (2015) Bovine jugular veins versus homografts in the pulmonary position: an analysis across two centers and 711 patients\u2014conventional comparisons and time status graphs as a new approach. Thorac Cardiovasc Surg 64(01):025\u2013035. https:\/\/doi.org\/10.1055\/s-0035-1554962","journal-title":"Thorac Cardiovasc Surg"},{"issue":"1","key":"4421_CR23","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.121.010852","volume":"15","author":"TK Jones","year":"2022","unstructured":"Jones TK, McElhinney DB, Vincent JA et al (2022) Long-term outcomes after Melody transcatheter pulmonary valve replacement in the US investigational device exemption trial. Circ Cardiovasc Interv 15(1):e010852. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.121.010852","journal-title":"Circ Cardiovasc Interv"},{"issue":"11","key":"4421_CR24","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1016\/J.JCIN.2014.08.002","volume":"7","author":"AK Armstrong","year":"2014","unstructured":"Armstrong AK, Balzer DT, Cabalka AK et al (2014) One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study. JACC Cardiovasc Interv 7(11):1254\u20131262. https:\/\/doi.org\/10.1016\/J.JCIN.2014.08.002","journal-title":"JACC Cardiovasc Interv"},{"issue":"3","key":"4421_CR25","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1002\/CCD.27973","volume":"93","author":"S Sinha","year":"2019","unstructured":"Sinha S, Aboulhosn J, Asnes J et al (2019) Initial results from the off-label use of the SAPIEN S3 valve for percutaneous transcatheter pulmonary valve replacement: a multi-institutional experience. Catheter Cardiovasc Interv 93(3):455\u2013463. https:\/\/doi.org\/10.1002\/CCD.27973","journal-title":"Catheter Cardiovasc Interv"},{"issue":"24","key":"4421_CR26","doi-asserted-by":"publisher","first-page":"2847","DOI":"10.1016\/J.JACC.2020.10.041","volume":"76","author":"S Shahanavaz","year":"2020","unstructured":"Shahanavaz S, Zahn EM, Levi DS et al (2020) Transcatheter pulmonary valve replacement with the sapien prosthesis. J Am Coll Cardiol 76(24):2847\u20132858. https:\/\/doi.org\/10.1016\/J.JACC.2020.10.041","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"4421_CR27","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/J.JCIN.2018.01.239","volume":"11","author":"S Shahanavaz","year":"2018","unstructured":"Shahanavaz S, Qureshi AM, Levi DS et al (2018) Transcatheter pulmonary valve replacement with the melody valve in small diameter expandable right ventricular outflow tract conduits. JACC Cardiovasc Interv 11(6):554\u2013564. https:\/\/doi.org\/10.1016\/J.JCIN.2018.01.239","journal-title":"JACC Cardiovasc Interv"},{"issue":"3","key":"4421_CR28","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1002\/CCD.27974","volume":"93","author":"BH Morray","year":"2019","unstructured":"Morray BH, Jones TK, Coe JY et al (2019) Implantation of the Melody transcatheter pulmonary valve PB1016 in patients with dysfunctional right ventricular outflow tract conduits. Catheter Cardiovasc Interv 93(3):474\u2013480. https:\/\/doi.org\/10.1002\/CCD.27974","journal-title":"Catheter Cardiovasc Interv"},{"issue":"1","key":"4421_CR29","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1002\/ccd.27310","volume":"91","author":"G Penford","year":"2018","unstructured":"Penford G, Quandt D, Mehta C et al (2018) Stenting and overdilating small Gore-Tex vascular grafts in complex congenital heart disease. Catheter Cardiovasc Interv 91(1):71\u201380. https:\/\/doi.org\/10.1002\/ccd.27310","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-026-04421-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00246-026-04421-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-026-04421-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T11:03:40Z","timestamp":1786964620000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00246-026-04421-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,17]]},"references-count":29,"alternative-id":["4421"],"URL":"https:\/\/doi.org\/10.1007\/s00246-026-04421-x","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,17]]},"assertion":[{"value":"16 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Drs. Kreutzer, Trucco and Goldstein - research relationship with Medtronic and Edwards-Lifesciences.","order":1,"name":"Ethics","label":"Conflict of Interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}