{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T12:57:09Z","timestamp":1787921829370,"version":"build-2784847793"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"13","license":[{"start":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T00:00:00Z","timestamp":1631836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T00:00:00Z","timestamp":1631836800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s00247-021-05160-2","type":"journal-article","created":{"date-parts":[[2021,9,16]],"date-time":"2021-09-16T23:47:32Z","timestamp":1631836052000},"page":"2498-2506","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Patient-level dose monitoring in computed tomography: tracking cumulative dose from multiple multi-sequence exams with tube current modulation in children"],"prefix":"10.1007","volume":"51","author":[{"given":"Azadeh","family":"Tabari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinhua","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bob","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael S.","family":"Gee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9952-6891","authenticated-orcid":false,"given":"Sjirk J.","family":"Westra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,17]]},"reference":[{"key":"5160_CR1","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1148\/radiol.2020192256","volume":"295","author":"FA Mettler Jr","year":"2020","unstructured":"Mettler FA Jr, Mahesh M, Bhargavan-Chatfield M et al (2020) Patient exposure from radiologic and nuclear medicine procedures in the United States: procedure volume and effective dose for the period 2006\u20132016. Radiology 295:418\u2013427","journal-title":"Radiology"},{"key":"5160_CR2","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1148\/radiol.2511081296","volume":"251","author":"A Sodickson","year":"2009","unstructured":"Sodickson A, Baeyens PF, Andriole KP et al (2009) Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology 251:175\u2013184","journal-title":"Radiology"},{"key":"5160_CR3","doi-asserted-by":"publisher","first-page":"1828","DOI":"10.1007\/s00330-019-06523-y","volume":"30","author":"MM Rehani","year":"2020","unstructured":"Rehani MM, Yang K, Melick ER et al (2020) Patients undergoing recurrent CT scans: assessing the magnitude. Eur Radiol 30:1828\u20131836","journal-title":"Eur Radiol"},{"key":"5160_CR4","doi-asserted-by":"publisher","first-page":"1839","DOI":"10.1007\/s00330-019-06551-8","volume":"30","author":"MM Rehani","year":"2020","unstructured":"Rehani MM, Melick ER, Alvi RM et al (2020) Patients undergoing recurrent CT exams: assessment of patients with non-malignant diseases, reasons for imaging and imaging appropriateness. Eur Radiol 30:1839\u20131846","journal-title":"Eur Radiol"},{"key":"5160_CR5","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1001\/jama.2010.973","volume":"304","author":"DJ Brenner","year":"2010","unstructured":"Brenner DJ, Hricak H (2010) Radiation exposure from medical imaging: time to regulate? JAMA 304:208\u2013209","journal-title":"JAMA"},{"key":"5160_CR6","doi-asserted-by":"publisher","first-page":"810","DOI":"10.2214\/AJR.14.13693","volume":"204","author":"EJ Zucker","year":"2015","unstructured":"Zucker EJ, Larson DB, Newman B et al (2015) Radiologist compliance with California CT dose reporting requirements: a single-center review of pediatric chest CT. AJR Am J Roentgenol 204:810\u2013816","journal-title":"AJR Am J Roentgenol"},{"key":"5160_CR7","unstructured":"American Association of Physicists in Medicine (2011) Report of Task Group 204: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. https:\/\/www.aapm.org\/pubs\/reports\/rpt_204.pdf. Accessed 6 June 2021"},{"key":"5160_CR8","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1016\/j.acra.2015.12.008","volume":"23","author":"A Padole","year":"2016","unstructured":"Padole A, Deedar Ali Khawaja R, Otrakji A et al (2016) Comparison of measured and estimated CT organ doses for modulated and fixed tube current: a human cadaver study. Acad Radiol 23:634\u2013642","journal-title":"Acad Radiol"},{"key":"5160_CR9","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1093\/rpd\/ncs275","volume":"155","author":"E Samei","year":"2013","unstructured":"Samei E, Li X, Chen B, Reiman R (2013) The effect of dose heterogeneity on radiation risk in medical imaging. Radiat Prot Dosim 155:42\u201358","journal-title":"Radiat Prot Dosim"},{"key":"5160_CR10","doi-asserted-by":"publisher","first-page":"3935","DOI":"10.1088\/0031-9155\/61\/10\/3935","volume":"61","author":"X Tian","year":"2016","unstructured":"Tian X, Segars WP, Dixon RL, Samei E (2016) Convolution-based estimation of organ dose in tube current modulated CT. Phys Med Biol 61:3935\u20133954","journal-title":"Phys Med Biol"},{"key":"5160_CR11","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1118\/1.3533897","volume":"38","author":"AC Turner","year":"2011","unstructured":"Turner AC, Zhang D, Khatonabadi M et al (2011) The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams. Med Phys 38:820\u2013829","journal-title":"Med Phys"},{"key":"5160_CR12","doi-asserted-by":"crossref","unstructured":"McCollough C, Bakalyar DM, Bostani M et al (2014) Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT. The report of AAPM Task Group 220. https:\/\/www.aapm.org\/pubs\/reports\/RPT_220.pdf. Accessed 6 June 2021","DOI":"10.37206\/146"},{"key":"5160_CR13","unstructured":"American Association of Physicists in Medicine (2010) Report of Task Group 111: Comprehensive methodology for the evaluation of radiation dose in x-ray computed tomography. https:\/\/www.aapm.org\/pubs\/reports\/RPT_111.pdf. Accessed 6 June 2021"},{"key":"5160_CR14","doi-asserted-by":"publisher","first-page":"111920","DOI":"10.1118\/1.4824918","volume":"40","author":"RL Dixon","year":"2013","unstructured":"Dixon RL, Boone JM (2013) Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDIvol. Med Phys 40:111920","journal-title":"Med Phys"},{"key":"5160_CR15","doi-asserted-by":"publisher","first-page":"2309","DOI":"10.1002\/mp.12888","volume":"45","author":"X Li","year":"2018","unstructured":"Li X, Yang K, Liu B (2018) Radiation dose dependence on subject size in abdominal computed tomography: water phantom and patient model comparison. Med Phys 45:2309\u20132317","journal-title":"Med Phys"},{"key":"5160_CR16","doi-asserted-by":"publisher","first-page":"5878","DOI":"10.1118\/1.4963811","volume":"43","author":"X Li","year":"2016","unstructured":"Li X, Yang K, Liu B (2016) A study of the midpoint dose to CTDIvol ratio: implications for CT dose evaluation. Med Phys 43:5878","journal-title":"Med Phys"},{"key":"5160_CR17","doi-asserted-by":"publisher","first-page":"5347","DOI":"10.1118\/1.4742070","volume":"39","author":"X Li","year":"2012","unstructured":"Li X, Zhang D, Liu B (2012) Equations for CT dose calculations on axial lines based on the principle of symmetry. Med Phys 39:5347\u20135352","journal-title":"Med Phys"},{"key":"5160_CR18","doi-asserted-by":"publisher","first-page":"111910","DOI":"10.1118\/1.4898124","volume":"41","author":"X Li","year":"2014","unstructured":"Li X, Zhang D, Liu B (2014) Radiation dose calculations for CT scans with tube current modulation using the approach to equilibrium function. Med Phys 41:111910","journal-title":"Med Phys"},{"key":"5160_CR19","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1002\/mp.13431","volume":"46","author":"X Li","year":"2019","unstructured":"Li X, Yang K, Liu B (2019) Exam-level dose monitoring in CT: quality metric consideration for multiple series acquisitions. Med Phys 46:1575\u20131580","journal-title":"Med Phys"},{"key":"5160_CR20","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1118\/1.3678990","volume":"39","author":"X Li","year":"2012","unstructured":"Li X, Zhang D, Liu B (2012) Estimation of the weighted CTDI(infinity) for multislice CT examinations. Med Phys 39:901\u2013905","journal-title":"Med Phys"},{"key":"5160_CR21","doi-asserted-by":"publisher","first-page":"1833","DOI":"10.1148\/rg.317115048","volume":"31","author":"TS Cook","year":"2011","unstructured":"Cook TS, Zimmerman SL, Steingall SR et al (2011) RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. Radiographics 31:1833\u20131846","journal-title":"Radiographics"},{"key":"5160_CR22","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1053\/j.ro.2018.02.002","volume":"53","author":"NM Cross","year":"2018","unstructured":"Cross NM, Zamora DA, Moirano JM et al (2018) Practical CT dose monitoring: current tools and the clinical relevance. Semin Roentgenol 53:115\u2013123","journal-title":"Semin Roentgenol"},{"key":"5160_CR23","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1148\/radiol.2017161911","volume":"284","author":"KM Kanal","year":"2017","unstructured":"Kanal KM, Butler PF, Sengupta D et al (2017) U.S. diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology 284:120\u2013133","journal-title":"Radiology"},{"key":"5160_CR24","doi-asserted-by":"publisher","first-page":"953","DOI":"10.2214\/AJR.14.13317","volume":"204","author":"SL Brady","year":"2015","unstructured":"Brady SL, Mirro AE, Moore BM, Kaufman RA (2015) How to appropriately calculate effective dose for CT using either size-specific dose estimates or dose-length product. AJR Am J Roentgenol 204:953\u2013958","journal-title":"AJR Am J Roentgenol"},{"key":"5160_CR25","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1118\/1.2713240","volume":"34","author":"JM Boone","year":"2007","unstructured":"Boone JM (2007) The trouble with CTD100. Med Phys 34:1364\u20131371","journal-title":"Med Phys"},{"key":"5160_CR26","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1097\/PTS.0b013e3182a8c2c4","volume":"9","author":"D Frush","year":"2013","unstructured":"Frush D, Denham CR, Goske MJ et al (2013) Radiation protection and dose monitoring in medical imaging: a journey from awareness, through accountability, ability and action...but where will we arrive? J Patient Saf 9:232\u2013238","journal-title":"J Patient Saf"},{"key":"5160_CR27","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1001\/jamapediatrics.2013.311","volume":"167","author":"DL Miglioretti","year":"2013","unstructured":"Miglioretti DL, Johnson E, Williams A et al (2013) The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatr 167:700\u2013707","journal-title":"JAMA Pediatr"},{"key":"5160_CR28","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.icrp.2012.07.001","volume":"41","author":"DJ Brenner","year":"2012","unstructured":"Brenner DJ (2012) We can do better than effective dose for estimating or comparing low-dose radiation risks. Ann ICRP 41:124\u2013128","journal-title":"Ann ICRP"},{"key":"5160_CR29","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1177\/0146645315576096","volume":"44","author":"J Harrison","year":"2015","unstructured":"Harrison J, Lopez PO (2015) Use of effective dose in medicine. Ann ICRP 44:221\u2013228","journal-title":"Ann ICRP"},{"key":"5160_CR30","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1016\/j.jacr.2012.03.003","volume":"9","author":"DJ Durand","year":"2012","unstructured":"Durand DJ, Dixon RL, Morin RL (2012) Utilization strategies for cumulative dose estimates: a review and rational assessment. J Am Coll Radiol 9:480\u2013485","journal-title":"J Am Coll Radiol"},{"key":"5160_CR31","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.icrp.2012.06.002","volume":"41","author":"MI Balonov","year":"2012","unstructured":"Balonov MI, Shrimpton PC (2012) Effective dose and risks from medical X-ray procedures. Ann ICRP 41:129\u2013141","journal-title":"Ann ICRP"},{"key":"5160_CR32","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1148\/radiol.11101800","volume":"259","author":"CH McCollough","year":"2011","unstructured":"McCollough CH, Leng S, Yu L et al (2011) CT dose index and patient dose: they are not the same thing. Radiology 259:311\u2013316","journal-title":"Radiology"},{"key":"5160_CR33","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1148\/radiol.2502081340","volume":"250","author":"PC Shrimpton","year":"2009","unstructured":"Shrimpton PC, Wall BF, Yoshizumi TT et al (2009) Effective dose and dose-length product in CT. Radiology 250:604\u2013605","journal-title":"Radiology"},{"key":"5160_CR34","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.2214\/AJR.09.3771","volume":"194","author":"PL Kleinman","year":"2010","unstructured":"Kleinman PL, Strauss KJ, Zurakowski D et al (2010) Patient size measured on CT images as a function of age at a tertiary care children\u2019s hospital. AJR Am J Roentgenol 194:1611\u20131619","journal-title":"AJR Am J Roentgenol"},{"key":"5160_CR35","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1007\/s00247-014-3117-7","volume":"44","author":"E Samei","year":"2014","unstructured":"Samei E, Tian X, Segars WP (2014) Determining organ dose: the holy grail. Pediatr Radiol 44:460\u2013467","journal-title":"Pediatr Radiol"},{"key":"5160_CR36","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab0e97","volume":"64","author":"S Rosendahl","year":"2019","unstructured":"Rosendahl S, B\u00fcermann L, Borowski M et al (2019) CT beam dosimetric characterization procedure for personalized dosimetry. Phys Med Biol 64:075009","journal-title":"Phys Med Biol"},{"key":"5160_CR37","doi-asserted-by":"publisher","first-page":"7131","DOI":"10.1118\/1.4761871","volume":"39","author":"O Christianson","year":"2012","unstructured":"Christianson O, Li X, Frush D, Samei E (2012) Automated size-specific CT dose monitoring program: assessing variability in CT dose. Med Phys 39:7131\u20137139","journal-title":"Med Phys"},{"key":"5160_CR38","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1148\/radiol.11101900","volume":"259","author":"X Li","year":"2011","unstructured":"Li X, Samei E, Segars WP et al (2011) Patient-specific radiation dose and cancer risk for pediatric chest CT. Radiology 259:862\u2013874","journal-title":"Radiology"},{"key":"5160_CR39","doi-asserted-by":"publisher","DOI":"10.1118\/1.4883778","volume":"41","author":"P Sahbaee","year":"2014","unstructured":"Sahbaee P, Segars WP, Samei E (2014) Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories. Med Phys 41:072104","journal-title":"Med Phys"},{"key":"5160_CR40","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1118\/1.4907955","volume":"42","author":"X Tian","year":"2015","unstructured":"Tian X, Li X, Segars WP et al (2015) Prospective estimation of organ dose in CT under tube current modulation. Med Phys 42:1575\u20131585","journal-title":"Med Phys"},{"key":"5160_CR41","doi-asserted-by":"publisher","first-page":"1340","DOI":"10.2214\/AJR.09.2886","volume":"193","author":"E Angel","year":"2009","unstructured":"Angel E, Yaghmai N, Jude CM et al (2009) Dose to radiosensitive organs during routine chest CT: effects of tube current modulation. AJR Am J Roentgenol 193:1340\u20131345","journal-title":"AJR Am J Roentgenol"},{"key":"5160_CR42","doi-asserted-by":"publisher","first-page":"1816","DOI":"10.1118\/1.3368596","volume":"37","author":"AC Turner","year":"2010","unstructured":"Turner AC, Zankl M, DeMarco JJ et al (2010) The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDIvol to account for differences between scanners. Med Phys 37:1816\u20131825","journal-title":"Med Phys"},{"key":"5160_CR43","doi-asserted-by":"publisher","first-page":"412","DOI":"10.2214\/AJR.11.7230","volume":"198","author":"D Zhang","year":"2012","unstructured":"Zhang D, Cagnon CH, Villablanca JP et al (2012) Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation. AJR Am J Roentgenol 198:412\u2013417","journal-title":"AJR Am J Roentgenol"},{"key":"5160_CR44","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1093\/rpd\/ncn187","volume":"129","author":"MW Charles","year":"2008","unstructured":"Charles MW (2008) ICRP publication 103: recommendations of the ICRP. Radiat Prot Dosim 129:500\u2013507","journal-title":"Radiat Prot Dosim"},{"key":"5160_CR45","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/j.jacr.2018.01.032","volume":"15","author":"N Kasraie","year":"2018","unstructured":"Kasraie N, Jordan D, Keup C et al (2018) Optimizing communication with parents on benefits and radiation risks in pediatric imaging. J Am Coll Radiol 15:809\u2013817","journal-title":"J Am Coll Radiol"},{"key":"5160_CR46","doi-asserted-by":"publisher","first-page":"109780","DOI":"10.1016\/j.ejrad.2021.109780","volume":"141","author":"X Li","year":"2021","unstructured":"Li X, Yang K, Westra SJ et al (2021) Fetal dose evaluation for body CT examinations of pregnant patients during all stages of pregnancy. Eur J Radiol 141:109780","journal-title":"Eur J Radiol"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-021-05160-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-021-05160-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-021-05160-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,6]],"date-time":"2023-02-06T16:03:18Z","timestamp":1675699398000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-021-05160-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,17]]},"references-count":46,"journal-issue":{"issue":"13","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["5160"],"URL":"https:\/\/doi.org\/10.1007\/s00247-021-05160-2","relation":{},"ISSN":["0301-0449","1432-1998"],"issn-type":[{"value":"0301-0449","type":"print"},{"value":"1432-1998","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,17]]},"assertion":[{"value":"20 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}