{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T20:27:08Z","timestamp":1790195228632,"version":"4.1.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T00:00:00Z","timestamp":1631836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T00:00:00Z","timestamp":1631836800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1007\/s00247-021-05190-w","type":"journal-article","created":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T22:02:40Z","timestamp":1631916160000},"page":"549-558","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Improving the detection of ventricular shunt disruption using volume-rendered three-dimensional head computed tomography"],"prefix":"10.1007","volume":"52","author":[{"given":"Murat Alp","family":"Oztek","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marguerite T.","family":"Parisi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco A.","family":"Perez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helen H. R.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey P.","family":"Otjen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5333-1773","authenticated-orcid":false,"given":"Grace S.","family":"Phillips","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,17]]},"reference":[{"key":"5190_CR1","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1159\/000452840","volume":"52","author":"BW Hanak","year":"2017","unstructured":"Hanak BW, Bonow RH, Harris CA, Browd SR (2017) Cerebrospinal fluid shunting complications in children. Pediatr Neurosurg 52:381\u2013400","journal-title":"Pediatr Neurosurg"},{"key":"5190_CR2","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1159\/000477174","volume":"52","author":"KL Tomei","year":"2017","unstructured":"Tomei KL (2017) The evolution of cerebrospinal fluid shunts: advances in technology and technique. Pediatr Neurosurg 52:369\u2013380","journal-title":"Pediatr Neurosurg"},{"key":"5190_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.2214\/AJR.12.10270","volume":"202","author":"AN Wallace","year":"2014","unstructured":"Wallace AN, McConathy J, Menias CO et al (2014) Imaging evaluation of CSF shunts. AJR Am J Roentgenol 202:38\u201353","journal-title":"AJR Am J Roentgenol"},{"key":"5190_CR4","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s00381-017-3342-0","volume":"33","author":"FS Erol","year":"2017","unstructured":"Erol FS, Ozturk S, Akgun B, Kaplan M (2017) Ventriculoperitoneal shunt malfunction caused by fractures and disconnections over 10 years of follow-up. Childs Nerv Syst 33:475\u2013481","journal-title":"Childs Nerv Syst"},{"key":"5190_CR5","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1097\/PEC.0000000000000462","volume":"31","author":"TP Boyle","year":"2015","unstructured":"Boyle TP, Nigrovic LE (2015) Radiographic evaluation of pediatric cerebrospinal fluid shunt malfunction in the emergency setting. Pediatr Emerg Care 31:435\u2013440","journal-title":"Pediatr Emerg Care"},{"key":"5190_CR6","doi-asserted-by":"publisher","first-page":"420","DOI":"10.3171\/2014.9.PEDS14207","volume":"15","author":"EL Yue","year":"2015","unstructured":"Yue EL, Meckler GD, Fleischman RJ et al (2015) Test characteristics of quick brain MRI for shunt evaluation in children: an alternative modality to avoid radiation. J Neurosurg Pediatr 15:420\u2013426","journal-title":"J Neurosurg Pediatr"},{"key":"5190_CR7","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1097\/PEC.0000000000000248","volume":"31","author":"I Kim","year":"2015","unstructured":"Kim I, Torrey SB, Milla SS et al (2015) Benefits of brain magnetic resonance imaging over computed tomography in children requiring emergency evaluation of ventriculoperitoneal shunt malfunction: reducing lifetime attributable risk of cancer. Pediatr Emerg Care 31:239\u2013242","journal-title":"Pediatr Emerg Care"},{"key":"5190_CR8","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1016\/j.ajem.2020.09.024","volume":"39","author":"A Jayanth","year":"2021","unstructured":"Jayanth A, Benabbas R, Chao J, Sinert R (2021) Diagnostic modalities to determine ventriculoperitoneal shunt malfunction: a systematic review and meta-analysis. Am J Emerg Med 39:180\u2013189","journal-title":"Am J Emerg Med"},{"key":"5190_CR9","doi-asserted-by":"publisher","first-page":"e479","DOI":"10.1016\/j.wneu.2020.02.003","volume":"137","author":"M Broggi","year":"2020","unstructured":"Broggi M, Zattra CM, Schiariti M et al (2020) Diagnosis of ventriculoperitoneal shunt malfunction: a practical algorithm. World Neurosurg 137:e479\u2013e486","journal-title":"World Neurosurg"},{"key":"5190_CR10","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.wneu.2019.07.065","volume":"130","author":"DK Jha","year":"2019","unstructured":"Jha DK, Khera P, Bhaskar S, Garg M (2019) Three-dimensional volume rendering: an underutilized tool in neurosurgery. World Neurosurg 130:485\u2013492","journal-title":"World Neurosurg"},{"key":"5190_CR11","doi-asserted-by":"publisher","first-page":"426","DOI":"10.3171\/2015.3.PEDS1553","volume":"16","author":"G Orman","year":"2015","unstructured":"Orman G, Wagner MW, Seeburg D et al (2015) Pediatric skull fracture diagnosis: should 3D CT reconstructions be added as routine imaging? J Neurosurg Pediatr 16:426\u2013431","journal-title":"J Neurosurg Pediatr"},{"key":"5190_CR12","first-page":"1276","volume":"16","author":"MW Stannard","year":"1995","unstructured":"Stannard MW, Rollins NK (1995) Subcutaneous catheter calcification in ventriculoperitoneal shunts. AJNR Am J Neuroradiol 16:1276\u20131278","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-021-05190-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-021-05190-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-021-05190-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T00:24:31Z","timestamp":1645230271000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-021-05190-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,17]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["5190"],"URL":"https:\/\/doi.org\/10.1007\/s00247-021-05190-w","relation":{},"ISSN":["0301-0449","1432-1998"],"issn-type":[{"value":"0301-0449","type":"print"},{"value":"1432-1998","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,17]]},"assertion":[{"value":"18 February 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}