{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:26:06Z","timestamp":1740108366480,"version":"3.37.3"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T00:00:00Z","timestamp":1701648000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T00:00:00Z","timestamp":1701648000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"DOI":"10.1007\/s00247-023-05810-7","type":"journal-article","created":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T07:02:46Z","timestamp":1701673366000},"page":"154-156","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Commentary: Achieving ALARA in scoliosis examinations by using body measurements to set techniques and eliminating physical anti-scatter grids"],"prefix":"10.1007","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9505-6928","authenticated-orcid":false,"given":"Steven","family":"Don","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Quentin T.","family":"Moore","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pam","family":"Hensley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,12,4]]},"reference":[{"key":"5810_CR1","doi-asserted-by":"publisher","unstructured":"Al-Dasuqi K, Taylor E, Ehrlich L et al (2023) Performance and reliability assessment of a lower dose, task-based scoliosis radiography protocol in pediatric patients. Pediatr Radiol. https:\/\/doi.org\/10.1007\/s00247-023-05812-5","DOI":"10.1007\/s00247-023-05812-5"},{"key":"5810_CR2","doi-asserted-by":"publisher","first-page":"S244","DOI":"10.1016\/j.jacr.2019.02.018","volume":"16","author":"JY Jones","year":"2019","unstructured":"Jones JY, Saigal G, Palasis S et al (2019) ACR Appropriateness Criteria\u00ae Scoliosis-Child. J Am Coll Radiol. 16:S244\u2013S51","journal-title":"J Am Coll Radiol."},{"key":"5810_CR3","unstructured":"Food and Drug Administration. Reducing Patient Exposure During Scoliosis Radiography. https:\/\/www.fda.gov\/radiation-emitting-products\/resources-you-radiation-emitting-products\/reducing-patient-exposure-during-scoliosis-radiography (2017). Accessed September 30, 2023"},{"key":"5810_CR4","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1001\/archpediatrics.2010.270","volume":"165","author":"AL Dorfman","year":"2011","unstructured":"Dorfman AL, Fazel R, Einstein AJ et al (2011) Use of medical imaging procedures with ionizing radiation in children: a population-based study. Arch Pediatr Adolesc Med 165:458\u2013464","journal-title":"Arch Pediatr Adolesc Med"},{"key":"5810_CR5","unstructured":"National Council on Radiation Protection Measurements (2019) Medical Radiation Exposure of Patients in the United States: NCRP Report. No. 184"},{"key":"5810_CR6","unstructured":"The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Annals of the ICRP"},{"key":"5810_CR7","doi-asserted-by":"publisher","first-page":"2052","DOI":"10.1097\/00007632-200008150-00009","volume":"25","author":"MM Doody","year":"2000","unstructured":"Doody MM, Lonstein JE, Stovall M et al (2000) Breast cancer mortality after diagnostic radiography: findings from the U.S. Scoliosis Cohort Study. Spine. 25:2052\u201363","journal-title":"Spine."},{"key":"5810_CR8","doi-asserted-by":"publisher","first-page":"3366","DOI":"10.1007\/s00586-016-4747-2","volume":"25","author":"A Simony","year":"2016","unstructured":"Simony A, Hansen EJ, Christensen SB et al (2016) Incidence of cancer in adolescent idiopathic scoliosis patients treated 25 years previously. Eur Spine J 25:3366\u20133370","journal-title":"Eur Spine J"},{"key":"5810_CR9","doi-asserted-by":"publisher","first-page":"3123","DOI":"10.1007\/s00586-020-06573-7","volume":"29","author":"F-J Luan","year":"2020","unstructured":"Luan F-J, Wan Y, Mak K-C et al (2020) Cancer and mortality risks of patients with scoliosis from radiation exposure: a systematic review and meta-analysis. Eur Spine J 29:3123\u20133134","journal-title":"Eur Spine J"},{"key":"5810_CR10","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.1097\/BRS.0000000000003507","volume":"45","author":"PJ Cundy","year":"2020","unstructured":"Cundy PJ, Venugopal K, Antoniou G et al (2020) Do Children With Spinal Deformity Who Have Metal Implants and Frequent Exposure to X-Rays Increase Their Risk of Cancer? Spine 45:1200\u20131207","journal-title":"Spine"},{"key":"5810_CR11","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.2214\/AJR.09.3771","volume":"194","author":"PL Kleinman","year":"2010","unstructured":"Kleinman PL, Strauss KJ, Zurakowski D et al (2010) Patient size measured on CT images as a function of age at a tertiary care children\u2019s hospital. AJR Am J Roentgenol 194:1611\u20131619","journal-title":"AJR Am J Roentgenol"},{"key":"5810_CR12","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1016\/j.spinee.2015.12.012","volume":"16","author":"A Ben-Shlomo","year":"2016","unstructured":"Ben-Shlomo A, Bartal G, Mosseri M et al (2016) Effective dose reduction in spine radiographic imaging by choosing the less radiation-sensitive side of the body. The Spine Journal 16:558\u2013563","journal-title":"The Spine Journal"},{"key":"5810_CR13","volume":"42","author":"S Don","year":"2012","unstructured":"Don S, Goski M, Uzenoff R et al (2012) SPR 2012. Pediatr Radiol 42:s284","journal-title":"Pediatr Radiol"},{"key":"5810_CR14","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13582","volume":"23","author":"M Hoerner","year":"2022","unstructured":"Hoerner M, Grizzard K, Moroz J (2022) Method of determining technique from weight and height to achieve targeted detector exposures in portable chest and abdominal digital radiography. J Appl Clin Med Phys 23:e13582","journal-title":"J Appl Clin Med Phys"},{"key":"5810_CR15","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1007\/s00247-017-3968-9","volume":"48","author":"RD MacDougall","year":"2018","unstructured":"MacDougall RD, Scherrer B, Don S (2018) Development of a tool to aid the radiologic technologist using augmented reality and computer vision. Pediatr Radiol 48:141\u2013145","journal-title":"Pediatr Radiol"},{"key":"5810_CR16","doi-asserted-by":"crossref","unstructured":"Couwenhoven M, Sehnert W, Wang X et al (2005) Observer study of a noise suppression algorithm for computed radiography images. Medical Imaging. SPIE Proceedings of Medical Imaging 5749:318\u2013327","DOI":"10.1117\/12.595159"},{"key":"5810_CR17","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1016\/j.diii.2021.01.009","volume":"102","author":"JA Feghali","year":"2021","unstructured":"Feghali JA, Chambers G, Delepierre J et al (2021) New image quality and dose reduction technique for pediatric digital radiography. Diagn Interv Imaging 102:463\u2013470","journal-title":"Diagn Interv Imaging"},{"key":"5810_CR18","unstructured":"Fauber T. Radiographic Imaging and Exposure. 6th ed. Mosby; 2021"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-023-05810-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-023-05810-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-023-05810-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T09:04:07Z","timestamp":1704791047000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-023-05810-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,4]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["5810"],"URL":"https:\/\/doi.org\/10.1007\/s00247-023-05810-7","relation":{},"ISSN":["1432-1998"],"issn-type":[{"type":"electronic","value":"1432-1998"}],"subject":[],"published":{"date-parts":[[2023,12,4]]},"assertion":[{"value":"2 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 November 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 November 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 December 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}