{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:08:22Z","timestamp":1762499302141,"version":"build-2065373602"},"reference-count":100,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T00:00:00Z","timestamp":1737417600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T00:00:00Z","timestamp":1737417600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100017540","name":"NHLBI Division of Intramural Research","doi-asserted-by":"publisher","award":["5T32HL007572-39"],"award-info":[{"award-number":["5T32HL007572-39"]}],"id":[{"id":"10.13039\/100017540","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"DOI":"10.1007\/s00247-024-06144-8","type":"journal-article","created":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T04:17:38Z","timestamp":1737433058000},"page":"2325-2335","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cardiovascular imaging in children with cardiac implantable electronic devices"],"prefix":"10.1007","volume":"55","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1052-9736","authenticated-orcid":false,"given":"Benjamin","family":"Zielonka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashwin","family":"Prakash","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Douglas Y.","family":"Mah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Annese","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Smalley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel A.","family":"Castellanos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,1,21]]},"reference":[{"key":"6144_CR1","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1111\/j.1540-8159.2011.03150.x","volume":"34","author":"HG Mond","year":"2011","unstructured":"Mond HG, Proclemer A (2011) The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009\u2013a World Society of Arrhythmia\u2019s project. Pacing Clin Electrophysiol 34:1013\u20131027","journal-title":"Pacing Clin Electrophysiol"},{"key":"6144_CR2","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1111\/j.1540-8159.2009.02365.x","volume":"32","author":"K Takahashi","year":"2009","unstructured":"Takahashi K, Cecchin F, Fortescue E et al (2009) Permanent atrial pacing lead implant route after Fontan operation. Pacing Clin Electrophysiol 32:779\u2013785","journal-title":"Pacing Clin Electrophysiol"},{"key":"6144_CR3","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1016\/j.hrthm.2023.02.017","volume":"20","author":"CI Berul","year":"2023","unstructured":"Berul CI, Dasgupta S, LeGras MD et al (2023) Tiny pacemakers for tiny babies. Heart Rhythm 20:766\u2013769","journal-title":"Heart Rhythm"},{"key":"6144_CR4","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.hrthm.2011.09.004","volume":"9","author":"RJ Czosek","year":"2012","unstructured":"Czosek RJ, Meganathan K, Anderson JB et al (2012) Cardiac rhythm devices in the pediatric population: utilization and complications. Heart Rhythm 9:199\u2013208","journal-title":"Heart Rhythm"},{"key":"6144_CR5","doi-asserted-by":"publisher","first-page":"e2341174","DOI":"10.1001\/jamanetworkopen.2023.41174","volume":"6","author":"A Mondal","year":"2023","unstructured":"Mondal A, Yoo M, Tuttle S et al (2023) Cost of pacing in pediatric patients with postoperative heart block after congenital heart surgery. Jama Netw Open 6:e2341174","journal-title":"Jama Netw Open"},{"key":"6144_CR6","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/j.jcct.2013.11.002","volume":"7","author":"BK Han","year":"2013","unstructured":"Han BK, Lesser AM, Vezmar M et al (2013) Cardiovascular imaging trends in congenital heart disease: a single center experience. J Cardiovasc Comput Tomogr 7:361\u2013366","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"6144_CR7","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.1016\/j.echo.2020.06.019","volume":"33","author":"S Anderson","year":"2020","unstructured":"Anderson S, Figueroa J, McCracken CE et al (2020) Factors influencing temporal trends in pediatric inpatient imaging utilization. J Am Soc Echocardiogr 33:1517\u20131525","journal-title":"J Am Soc Echocardiogr"},{"issue":"3","key":"6144_CR8","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.jcct.2024.02.002","volume":"18","author":"R Epstein","year":"2024","unstructured":"Epstein R, Yomogida M, Donovan D et al (2024) Trends in cardiac CT utilization for patients with pediatric and congenital heart disease: a multicenter survey study. J Cardiovasc Comput Tomogr 18(3):267\u201373","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"6144_CR9","doi-asserted-by":"publisher","first-page":"e97","DOI":"10.1016\/j.hrthm.2017.04.025","volume":"14","author":"JH Indik","year":"2017","unstructured":"Indik JH, Gimbel JR, Abe H et al (2017) 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm 14:e97\u2013e153","journal-title":"Heart Rhythm"},{"key":"6144_CR10","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1161\/CIRCIMAGING.109.875021","volume":"3","author":"A Prakash","year":"2010","unstructured":"Prakash A, Powell AJ, Geva T (2010) Multimodality noninvasive imaging for assessment of congenital heart disease. Circ Cardiovasc Imaging 3:112\u2013125","journal-title":"Circ Cardiovasc Imaging"},{"key":"6144_CR11","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1016\/j.jacc.2019.10.002","volume":"75","author":"R Sachdeva","year":"2020","unstructured":"Sachdeva R, Valente AM, Armstrong AK et al (2020) ACC\/AHA\/ASE\/HRS\/ISACHD\/SCAI\/SCCT\/SCMR\/SOPE 2020 appropriate use criteria for multimodality imaging during the follow-up care of patients with congenital heart disease: a report of the American College of Cardiology Solution Set Oversight Committee and Appropriate Use Criteria Task Force, American Heart Association, American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Pediatric Echocardiography. J Am Coll Cardiol 75:657\u2013703","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR12","doi-asserted-by":"crossref","unstructured":"Shah MJ, Silka MJ, Silva JNA et al (2021) 2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients. Cardiol Young 31:1738-1769","DOI":"10.1017\/S1047951121003413"},{"key":"6144_CR13","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1016\/j.jcct.2015.07.007","volume":"9","author":"BK Han","year":"2015","unstructured":"Han BK, Rigsby CK, Leipsic J et al (2015) Computed tomography imaging in patients with congenital heart disease, part 2: technical recommendations. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT): Endorsed by the Society of Pediatric Radiology (SPR) and the North American Society of Cardiac Imaging (NASCI). J Cardiovasc Comput Tomogr 9:493\u2013513","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"6144_CR14","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1136\/heartjnl-2013-304958","volume":"100","author":"AM Valente","year":"2014","unstructured":"Valente AM, Gauvreau K, Assenza GE et al (2014) Contemporary predictors of death and sustained ventricular tachycardia in patients with repaired tetralogy of Fallot enrolled in the INDICATOR cohort. Heart 100:247\u2013253","journal-title":"Heart"},{"key":"6144_CR15","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.1016\/j.jacc.2017.03.582","volume":"69","author":"AM Atz","year":"2017","unstructured":"Atz AM, Zak V, Mahony L et al (2017) Longitudinal outcomes of patients with single ventricle after the Fontan procedure. J Am Coll Cardiol 69:2735\u20132744","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR16","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1016\/j.jcmg.2021.09.016","volume":"15","author":"AC Egbe","year":"2022","unstructured":"Egbe AC, Miranda WR, Jain CC, Connolly HM (2022) Prognostic implications of progressive systemic ventricular dysfunction in congenitally corrected transposition of great arteries. JACC Cardiovasc Imaging 15:566\u2013574","journal-title":"JACC Cardiovasc Imaging"},{"key":"6144_CR17","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1161\/CIRCIMAGING.113.001473","volume":"7","author":"RH Rathod","year":"2014","unstructured":"Rathod RH, Prakash A, Kim YY et al (2014) Cardiac magnetic resonance parameters predict transplantation-free survival in patients with Fontan circulation. Circ Cardiovasc Imaging 7:502\u2013509","journal-title":"Circ Cardiovasc Imaging"},{"key":"6144_CR18","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1111\/j.1540-8159.2006.00358.x","volume":"29","author":"J Nothroff","year":"2006","unstructured":"Nothroff J, Norozi K, Alpers V et al (2006) Pacemaker implantation as a risk factor for heart failure in young adults with congenital heart disease. Pacing Clin Electrophysiol 29:386\u2013392","journal-title":"Pacing Clin Electrophysiol"},{"key":"6144_CR19","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1111\/j.1540-8167.2006.00741.x","volume":"18","author":"JJ Kim","year":"2007","unstructured":"Kim JJ, Friedman RA, Eidem BW et al (2007) Ventricular function and long-term pacing in children with congenital complete atrioventricular block. J Cardiovasc Electrophysiol 18:373\u2013377","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"2","key":"6144_CR20","doi-asserted-by":"publisher","first-page":"e001374","DOI":"10.1136\/openhrt-2020-001374","volume":"7","author":"BM Moore","year":"2020","unstructured":"Moore BM, Medi C, McGuire MA et al (2020) Pacing-associated cardiomyopathy in adult congenital heart disease. Open Heart 7(2):e001374","journal-title":"Open Heart"},{"key":"6144_CR21","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.jcmg.2011.05.007","volume":"5","author":"CJ Clarke","year":"2012","unstructured":"Clarke CJ, Gurka MJ, Norton PT et al (2012) Assessment of the accuracy and reproducibility of RV volume measurements by CMR in congenital heart disease. JACC Cardiovasc Imaging 5:28\u201337","journal-title":"JACC Cardiovasc Imaging"},{"key":"6144_CR22","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1080\/10976640701545073","volume":"9","author":"TD Karamitsos","year":"2007","unstructured":"Karamitsos TD, Hudsmith LE, Selvanayagam JB et al (2007) Operator induced variability in left ventricular measurements with cardiovascular magnetic resonance is improved after training. J Cardiovasc Magn Reson 9:777\u2013783","journal-title":"J Cardiovasc Magn Reson"},{"key":"6144_CR23","doi-asserted-by":"publisher","first-page":"2034","DOI":"10.1016\/j.jacc.2006.04.104","volume":"48","author":"M Dewey","year":"2006","unstructured":"Dewey M, Muller M, Eddicks S et al (2006) Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging. J Am Coll Cardiol 48:2034\u20132044","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR24","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1259\/bjr\/18500608","volume":"82","author":"K Debl","year":"2009","unstructured":"Debl K, Djavidani B, Buchner S et al (2009) Quantification of left-to-right shunting in adult congenital heart disease: phase-contrast cine MRI compared with invasive oximetry. Br J Radiol 82:386\u2013391","journal-title":"Br J Radiol"},{"issue":"1523\u20131525","key":"6144_CR25","first-page":"A1529","volume":"91","author":"AJ Powell","year":"2003","unstructured":"Powell AJ, Tsai-Goodman B, Prakash A et al (2003) Comparison between phase-velocity cine magnetic resonance imaging and invasive oximetry for quantification of atrial shunts. Am J Cardiol 91(1523\u20131525):A1529","journal-title":"Am J Cardiol"},{"key":"6144_CR26","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1161\/CIRCIMAGING.112.972588","volume":"5","author":"L Mercer-Rosa","year":"2012","unstructured":"Mercer-Rosa L, Yang W, Kutty S et al (2012) Quantifying pulmonary regurgitation and right ventricular function in surgically repaired tetralogy of Fallot: a comparative analysis of echocardiography and magnetic resonance imaging. Circ Cardiovasc Imaging 5:637\u2013643","journal-title":"Circ Cardiovasc Imaging"},{"key":"6144_CR27","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1161\/01.CIR.0000029103.26029.1E","volume":"106","author":"S Fratz","year":"2002","unstructured":"Fratz S, Hess J, Schwaiger M et al (2002) More accurate quantification of pulmonary blood flow by magnetic resonance imaging than by lung perfusion scintigraphy in patients with Fontan circulation. Circulation 106:1510\u20131513","journal-title":"Circulation"},{"key":"6144_CR28","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1186\/s12968-018-0505-4","volume":"20","author":"T Alsaied","year":"2018","unstructured":"Alsaied T, Sleeper LA, Masci M et al (2018) Maldistribution of pulmonary blood flow in patients after the Fontan operation is associated with worse exercise capacity. J Cardiovasc Magn Reson 20:85","journal-title":"J Cardiovasc Magn Reson"},{"key":"6144_CR29","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1161\/CIRCIMAGING.108.834192","volume":"2","author":"L Grosse-Wortmann","year":"2009","unstructured":"Grosse-Wortmann L, Al-Otay A, Yoo SJ (2009) Aortopulmonary collaterals after bidirectional cavopulmonary connection or Fontan completion: quantification with MRI. Circ Cardiovasc Imaging 2:219\u2013225","journal-title":"Circ Cardiovasc Imaging"},{"issue":"1","key":"6144_CR30","doi-asserted-by":"publisher","first-page":"279","DOI":"10.3390\/jcm11010279","volume":"11","author":"F Graziano","year":"2022","unstructured":"Graziano F, Zorzi A, Cipriani A et al (2022) The 2020 \u201cPadua criteria\u201d for diagnosis and phenotype characterization of arrhythmogenic cardiomyopathy in clinical practice. J Clin Med 11(1):279","journal-title":"J Clin Med"},{"key":"6144_CR31","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.jacc.2004.09.053","volume":"45","author":"H Tandri","year":"2005","unstructured":"Tandri H, Saranathan M, Rodriguez ER et al (2005) Noninvasive detection of myocardial fibrosis in arrhythmogenic right ventricular cardiomyopathy using delayed-enhancement magnetic resonance imaging. J Am Coll Cardiol 45:98\u2013103","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR32","first-page":"358","volume":"29","author":"C Prinz","year":"2013","unstructured":"Prinz C, Schwarz M, Ilic I et al (2013) Myocardial fibrosis severity on cardiac magnetic resonance imaging predicts sustained arrhythmic events in hypertrophic cardiomyopathy. Can J Cardiol 29:358\u2013363","journal-title":"Can J Cardiol"},{"key":"6144_CR33","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1016\/j.amjcard.2016.01.032","volume":"117","author":"JA Spinner","year":"2016","unstructured":"Spinner JA, Noel CV, Denfield SW et al (2016) Association of late gadolinium enhancement and degree of left ventricular hypertrophy assessed on cardiac magnetic resonance imaging with ventricular tachycardia in children with hypertrophic cardiomyopathy. Am J Cardiol 117:1342\u20131348","journal-title":"Am J Cardiol"},{"key":"6144_CR34","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1016\/j.jtcvs.2006.10.057","volume":"133","author":"MA Harris","year":"2007","unstructured":"Harris MA, Johnson TR, Weinberg PM, Fogel MA (2007) Delayed-enhancement cardiovascular magnetic resonance identifies fibrous tissue in children after surgery for congenital heart disease. J Thorac Cardiovasc Surg 133:676\u2013681","journal-title":"J Thorac Cardiovasc Surg"},{"key":"6144_CR35","first-page":"15","volume":"3","author":"P Ylitalo","year":"2014","unstructured":"Ylitalo P, Pitkanen OM, Lauerma K et al (2014) Late gadolinium enhancement (LGE) progresses with right ventricle volume in children after repair of tetralogy of Fallot. Int J Cardiol Heart Vessel 3:15\u201320","journal-title":"Int J Cardiol Heart Vessel"},{"key":"6144_CR36","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1017\/S1047951114002248","volume":"25","author":"U Preim","year":"2015","unstructured":"Preim U, Sommer P, Hoffmann J et al (2015) Delayed enhancement imaging in a contemporary patient cohort following correction of tetralogy of Fallot. Cardiol Young 25:1268\u20131275","journal-title":"Cardiol Young"},{"key":"6144_CR37","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1161\/CIRCULATIONAHA.105.548727","volume":"113","author":"SV Babu-Narayan","year":"2006","unstructured":"Babu-Narayan SV, Kilner PJ, Li W et al (2006) Ventricular fibrosis suggested by cardiovascular magnetic resonance in adults with repaired tetralogy of Fallot and its relationship to adverse markers of clinical outcome. Circulation 113:405\u2013413","journal-title":"Circulation"},{"key":"6144_CR38","doi-asserted-by":"publisher","first-page":"1370","DOI":"10.1161\/CIRCULATIONAHA.108.816546","volume":"119","author":"RM Wald","year":"2009","unstructured":"Wald RM, Haber I, Wald R et al (2009) Effects of regional dysfunction and late gadolinium enhancement on global right ventricular function and exercise capacity in patients with repaired tetralogy of Fallot. Circulation 119:1370\u20131377","journal-title":"Circulation"},{"issue":"5","key":"6144_CR39","doi-asserted-by":"publisher","first-page":"e002628","DOI":"10.1161\/CIRCIMAGING.114.002628","volume":"8","author":"R Rydman","year":"2015","unstructured":"Rydman R, Gatzoulis MA, Ho SY et al (2015) Systemic right ventricular fibrosis detected by cardiovascular magnetic resonance is associated with clinical outcome, mainly new-onset atrial arrhythmia, in patients after atrial redirection surgery for transposition of the great arteries. Circ Cardiovasc Imaging 8(5):e002628","journal-title":"Circ Cardiovasc Imaging"},{"key":"6144_CR40","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1016\/j.jacc.2009.12.036","volume":"55","author":"RH Rathod","year":"2010","unstructured":"Rathod RH, Prakash A, Powell AJ, Geva T (2010) Myocardial fibrosis identified by cardiac magnetic resonance late gadolinium enhancement is associated with adverse ventricular mechanics and ventricular tachycardia late after Fontan operation. J Am Coll Cardiol 55:1721\u20131728","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR41","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.ijcard.2017.04.073","volume":"240","author":"A Kato","year":"2017","unstructured":"Kato A, Riesenkampff E, Yim D et al (2017) Pediatric Fontan patients are at risk for myocardial fibrotic remodeling and dysfunction. Int J Cardiol 240:172\u2013177","journal-title":"Int J Cardiol"},{"key":"6144_CR42","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1007\/s00330-017-5035-1","volume":"28","author":"MH Albrecht","year":"2018","unstructured":"Albrecht MH, Varga-Szemes A, Schoepf UJ et al (2018) Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease. Eur Radiol 28:1267\u20131275","journal-title":"Eur Radiol"},{"key":"6144_CR43","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1016\/j.acra.2018.12.010","volume":"26","author":"MH Albrecht","year":"2019","unstructured":"Albrecht MH, Varga-Szemes A, Schoepf UJ et al (2019) Diagnostic accuracy of noncontrast self-navigated free-breathing MR angiography versus CT angiography: a prospective study in pediatric patients with suspected anomalous coronary arteries. Acad Radiol 26:1309\u20131317","journal-title":"Acad Radiol"},{"key":"6144_CR44","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1007\/s00247-007-0566-2","volume":"37","author":"R Arnold","year":"2007","unstructured":"Arnold R, Ley S, Ley-Zaporozhan J et al (2007) Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization. Pediatr Radiol 37:998\u20131006","journal-title":"Pediatr Radiol"},{"key":"6144_CR45","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1016\/j.hrthm.2018.06.038","volume":"15","author":"DY Mah","year":"2018","unstructured":"Mah DY, Prakash A, Porras D et al (2018) Coronary artery compression from epicardial leads: more common than we think. Heart Rhythm 15:1439\u20131447","journal-title":"Heart Rhythm"},{"key":"6144_CR46","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1016\/j.jtcvs.2014.10.094","volume":"149","author":"EM Carreras","year":"2015","unstructured":"Carreras EM, Duncan WJ, Djurdjev O, Campbell AI (2015) Cardiac strangulation following epicardial pacemaker implantation: a rare pediatric complication. J Thorac Cardiovasc Surg 149:522\u2013527","journal-title":"J Thorac Cardiovasc Surg"},{"key":"6144_CR47","doi-asserted-by":"publisher","first-page":"1832","DOI":"10.1016\/j.jacc.2006.07.042","volume":"48","author":"NR Van de Veire","year":"2006","unstructured":"Van de Veire NR, Schuijf JD, De Sutter J et al (2006) Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography. J Am Coll Cardiol 48:1832\u20131838","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR48","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.2214\/AJR.04.1231","volume":"185","author":"G Muhlenbruch","year":"2005","unstructured":"Muhlenbruch G, Koos R, Wildberger JE et al (2005) Imaging of the cardiac venous system: comparison of MDCT and conventional angiography. AJR Am J Roentgenol 185:1252\u20131257","journal-title":"AJR Am J Roentgenol"},{"key":"6144_CR49","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1016\/j.amjcard.2013.11.016","volume":"113","author":"A Sharma","year":"2014","unstructured":"Sharma A, Einstein AJ, Vallakati A et al (2014) Meta-analysis of global left ventricular function comparing multidetector computed tomography with cardiac magnetic resonance imaging. Am J Cardiol 113:731\u2013738","journal-title":"Am J Cardiol"},{"key":"6144_CR50","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1007\/s00330-011-2345-6","volume":"22","author":"E Maffei","year":"2012","unstructured":"Maffei E, Messalli G, Martini C et al (2012) Left and right ventricle assessment with cardiac CT: validation study vs. cardiac MR. Eur Radiol 22:1041\u20131049","journal-title":"Eur Radiol"},{"key":"6144_CR51","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1016\/j.amjcard.2004.11.014","volume":"95","author":"SV Raman","year":"2005","unstructured":"Raman SV, Cook SC, McCarthy B, Ferketich AK (2005) Usefulness of multidetector row computed tomography to quantify right ventricular size and function in adults with either tetralogy of Fallot or transposition of the great arteries. Am J Cardiol 95:683\u2013686","journal-title":"Am J Cardiol"},{"key":"6144_CR52","doi-asserted-by":"publisher","first-page":"e757","DOI":"10.1016\/j.ejrad.2012.02.002","volume":"81","author":"C Asferg","year":"2012","unstructured":"Asferg C, Usinger L, Kristensen TS, Abdulla J (2012) Accuracy of multi-slice computed tomography for measurement of left ventricular ejection fraction compared with cardiac magnetic resonance imaging and two-dimensional transthoracic echocardiography: a systematic review and meta-analysis. Eur J Radiol 81:e757-762","journal-title":"Eur J Radiol"},{"key":"6144_CR53","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.jcct.2015.07.004","volume":"9","author":"BK Han","year":"2015","unstructured":"Han BK, Rigsby CK, Hlavacek A et al (2015) Computed tomography imaging in patients with congenital heart disease part I: rationale and utility. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT): Endorsed by the Society of Pediatric Radiology (SPR) and the North American Society of Cardiac Imaging (NASCI). J Cardiovasc Comput Tomogr 9:475\u2013492","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"6144_CR54","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1007\/s10554-010-9684-2","volume":"26","author":"IC Tsai","year":"2010","unstructured":"Tsai IC, Huang JL, Ueng KC et al (2010) Global and regional wall motion abnormalities of pacing-induced heart failure assessed by multi-detector row CT: a patient and canine model study. Int J Cardiovasc Imaging 26:223\u2013235","journal-title":"Int J Cardiovasc Imaging"},{"key":"6144_CR55","doi-asserted-by":"publisher","first-page":"1739","DOI":"10.1016\/j.hrthm.2023.06.018","volume":"20","author":"DA Castellanos","year":"2023","unstructured":"Castellanos DA, Carreon CK, Prakash A et al (2023) Pacemaker lead insertion sites contribute to abnormalities of myocardial function and histopathology. Heart Rhythm 20:1739\u20131749","journal-title":"Heart Rhythm"},{"key":"6144_CR56","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1148\/radiol.2531091030","volume":"253","author":"FG Shellock","year":"2009","unstructured":"Shellock FG, Woods TO, Crues JV 3rd (2009) MR labeling information for implants and devices: explanation of terminology. Radiology 253:26\u201330","journal-title":"Radiology"},{"key":"6144_CR57","doi-asserted-by":"publisher","first-page":"1752","DOI":"10.1016\/j.hrthm.2023.08.034","volume":"20","author":"L Gakenheimer-Smith","year":"2023","unstructured":"Gakenheimer-Smith L, Ou Z, Kuang J et al (2023) Multicenter retrospective evaluation of magnetic resonance imaging in pediatric and congenital heart disease patients with cardiac implantable electronic devices. Heart Rhythm 20:1752\u20131758","journal-title":"Heart Rhythm"},{"key":"6144_CR58","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1056\/NEJMoa1603265","volume":"376","author":"RJ Russo","year":"2017","unstructured":"Russo RJ, Costa HS, Silva PD et al (2017) Assessing the risks associated with MRI in patients with a pacemaker or defibrillator. N Engl J Med 376:755\u2013764","journal-title":"N Engl J Med"},{"key":"6144_CR59","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1056\/NEJMoa1604267","volume":"377","author":"S Nazarian","year":"2017","unstructured":"Nazarian S, Hansford R, Rahsepar AA et al (2017) Safety of magnetic resonance imaging in patients with cardiac devices. N Engl J Med 377:2555\u20132564","journal-title":"N Engl J Med"},{"key":"6144_CR60","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1007\/s00246-020-02316-z","volume":"41","author":"M Bireley","year":"2020","unstructured":"Bireley M, Kovach JR, Morton C et al (2020) Cardiac magnetic resonance imaging (MRI) in children is safe with most pacemaker systems, including those with epicardial leads. Pediatr Cardiol 41:801\u2013808","journal-title":"Pediatr Cardiol"},{"key":"6144_CR61","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1001\/jamacardio.2020.7572","volume":"6","author":"RD Schaller","year":"2021","unstructured":"Schaller RD, Brunker T, Riley MP et al (2021) Magnetic resonance imaging in patients with cardiac implantable electronic devices with abandoned leads. JAMA Cardiol 6:549\u2013556","journal-title":"JAMA Cardiol"},{"key":"6144_CR62","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1111\/pace.13984","volume":"43","author":"L Gakenheimer-Smith","year":"2020","unstructured":"Gakenheimer-Smith L, Etheridge SP, Niu MC et al (2020) MRI in pediatric and congenital heart disease patients with CIEDs and epicardial or abandoned leads. Pacing Clin Electrophysiol 43:797\u2013804","journal-title":"Pacing Clin Electrophysiol"},{"key":"6144_CR63","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/S1051-0443(07)61918-6","volume":"12","author":"LW Bartels","year":"2001","unstructured":"Bartels LW, Smits HF, Bakker CJ, Viergever MA (2001) MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents. J Vasc Interv Radiol 12:365\u2013371","journal-title":"J Vasc Interv Radiol"},{"key":"6144_CR64","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1161\/CIRCIMAGING.111.965764","volume":"4","author":"T Sasaki","year":"2011","unstructured":"Sasaki T, Hansford R, Zviman MM et al (2011) Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators. Circ Cardiovasc Imaging 4:662\u2013670","journal-title":"Circ Cardiovasc Imaging"},{"issue":"20","key":"6144_CR65","doi-asserted-by":"publisher","first-page":"6673","DOI":"10.3390\/jcm12206673","volume":"12","author":"A Barison","year":"2023","unstructured":"Barison A, Ricci F, Pavon AG et al (2023) Cardiovascular magnetic resonance in patients with cardiac electronic devices: evidence from a multicenter study. J Clin Med 12(20):6673","journal-title":"J Clin Med"},{"key":"6144_CR66","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1177\/0284185115574873","volume":"57","author":"T Kaasalainen","year":"2016","unstructured":"Kaasalainen T, Kivisto S, Holmstrom M et al (2016) Cardiac MRI in patients with cardiac pacemakers: practical methods for reducing susceptibility artifacts and optimizing image quality. Acta Radiol 57:178\u2013187","journal-title":"Acta Radiol"},{"key":"6144_CR67","doi-asserted-by":"publisher","first-page":"E126","DOI":"10.1148\/rg.2021200092","volume":"41","author":"EM Lee","year":"2021","unstructured":"Lee EM, Ibrahim EH, Dudek N et al (2021) Improving MR image quality in patients with metallic implants. Radiographics 41:E126\u2013E137","journal-title":"Radiographics"},{"key":"6144_CR68","doi-asserted-by":"publisher","first-page":"1229","DOI":"10.1007\/s00330-022-09059-w","volume":"33","author":"AM Vuorinen","year":"2023","unstructured":"Vuorinen AM, Lehmonen L, Karvonen J et al (2023) Reducing cardiac implantable electronic device-induced artefacts in cardiac magnetic resonance imaging. Eur Radiol 33:1229\u20131242","journal-title":"Eur Radiol"},{"key":"6144_CR69","doi-asserted-by":"publisher","first-page":"374","DOI":"10.2214\/AJR.19.21883","volume":"215","author":"J Stojanovska","year":"2020","unstructured":"Stojanovska J, Runge M, Mahani MG et al (2020) Cardiac MRI for patients with cardiac implantable electronic devices. aJR Am J Roentgenol 215:374\u2013381","journal-title":"aJR Am J Roentgenol"},{"key":"6144_CR70","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.1007\/s00247-015-3366-0","volume":"45","author":"LJ Olivieri","year":"2015","unstructured":"Olivieri LJ, Cross RR, O\u2019Brien KE et al (2015) Optimized protocols for cardiac magnetic resonance imaging in patients with thoracic metallic implants. Pediatr Radiol 45:1455\u20131464","journal-title":"Pediatr Radiol"},{"key":"6144_CR71","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1007\/s00247-006-0255-6","volume":"36","author":"J Wansapura","year":"2006","unstructured":"Wansapura J, Fleck R, Crotty E, Gottliebson W (2006) Frequency scouting for cardiac imaging with SSFP at 3 Tesla. Pediatr Radiol 36:1082\u20131085","journal-title":"Pediatr Radiol"},{"key":"6144_CR72","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1002\/mrm.10442","volume":"49","author":"VS Deshpande","year":"2003","unstructured":"Deshpande VS, Shea SM, Li D (2003) Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency. Magn Reson Med 49:803\u2013809","journal-title":"Magn Reson Med"},{"key":"6144_CR73","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1148\/radiol.13130942","volume":"270","author":"S Rashid","year":"2014","unstructured":"Rashid S, Rapacchi S, Vaseghi M et al (2014) Improved late gadolinium enhancement MR imaging for patients with implanted cardiac devices. Radiology 270:269\u2013274","journal-title":"Radiology"},{"key":"6144_CR74","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1093\/europace\/euu263","volume":"17","author":"R Ranjan","year":"2015","unstructured":"Ranjan R, McGann CJ, Jeong EK et al (2015) Wideband late gadolinium enhanced magnetic resonance imaging for imaging myocardial scar without image artefacts induced by implantable cardioverter-defibrillator: a feasibility study at 3 T. Europace 17:483\u2013488","journal-title":"Europace"},{"key":"6144_CR75","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1002\/mrm.27458","volume":"81","author":"K Hong","year":"2019","unstructured":"Hong K, Collins JD, Knight BP et al (2019) Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic device. Magn Reson Med 81:1219\u20131228","journal-title":"Magn Reson Med"},{"key":"6144_CR76","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.hrthm.2013.10.032","volume":"11","author":"SM Stevens","year":"2014","unstructured":"Stevens SM, Tung R, Rashid S et al (2014) Device artifact reduction for magnetic resonance imaging of patients with implantable cardioverter-defibrillators and ventricular tachycardia: late gadolinium enhancement correlation with electroanatomic mapping. Heart Rhythm 11:289\u2013298","journal-title":"Heart Rhythm"},{"key":"6144_CR77","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.hrcr.2024.02.003","volume":"10","author":"L Desai","year":"2024","unstructured":"Desai L, Popescu A, Golestanirad L et al (2024) Wideband magnetic resonance sequencing to decrease image artifact in a child with a cardiac implantable device. HeartRhythm Case Rep 10:292\u2013296","journal-title":"HeartRhythm Case Rep"},{"key":"6144_CR78","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"D Brenner","year":"2001","unstructured":"Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176:289\u2013296","journal-title":"AJR Am J Roentgenol"},{"key":"6144_CR79","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1016\/j.amjcard.2011.01.065","volume":"107","author":"BK Han","year":"2011","unstructured":"Han BK, Lindberg J, Grant K et alR (2011) Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease. Am J Cardiol 107:1541\u20131546","journal-title":"Am J Cardiol"},{"key":"6144_CR80","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1097\/RLI.0b013e3181f33b1d","volume":"46","author":"MM Lell","year":"2011","unstructured":"Lell MM, May M, Deak P et al (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Invest Radiol 46:116\u2013123","journal-title":"Invest Radiol"},{"key":"6144_CR81","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1161\/CIRCULATIONAHA.115.019412","volume":"133","author":"AA Elagha","year":"2016","unstructured":"Elagha AA, Weissman G (2016) Pacemaker malfunction attributed to multidetector cardiac computed tomography. Circulation 133:342\u2013343","journal-title":"Circulation"},{"key":"6144_CR82","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1148\/radiol.2433060993","volume":"243","author":"CH McCollough","year":"2007","unstructured":"McCollough CH, Zhang J, Primak AN et al (2007) Effects of CT irradiation on implantable cardiac rhythm management devices. Radiology 243:766\u2013774","journal-title":"Radiology"},{"key":"6144_CR83","doi-asserted-by":"publisher","first-page":"1769","DOI":"10.1016\/j.jacc.2013.12.040","volume":"63","author":"AA Hussein","year":"2014","unstructured":"Hussein AA, Abutaleb A, Jeudy J et al (2014) Safety of computed tomography in patients with cardiac rhythm management devices: assessment of the U.S. Food and Drug Administration advisory in clinical practice. J Am Coll Cardiol 63:1769\u20131775","journal-title":"J Am Coll Cardiol"},{"key":"6144_CR84","unstructured":"U.S. Food and Drug Administration (2016) Interference between CT and electronic medical devices. [Press release] https:\/\/www.fda.gov\/radiation-emitting-products\/radiation-safety\/electronic-medical-devices-x-ray-imaging-and-radiation-therapy-what-know-and-how-prevent-damage?utm_medium=email&utm_source=govdelivery"},{"key":"6144_CR85","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1148\/rg.246045065","volume":"24","author":"JF Barrett","year":"2004","unstructured":"Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679\u20131691","journal-title":"Radiographics"},{"key":"6144_CR86","doi-asserted-by":"publisher","first-page":"31","DOI":"10.3109\/14017430903114453","volume":"44","author":"M Sosnowski","year":"2010","unstructured":"Sosnowski M, Mlynarski R, Wlodyka A et al (2010) The presence of endocardial leads may limit applicability of coronary CT angiography. Scand Cardiovasc J 44:31\u201336","journal-title":"Scand Cardiovasc J"},{"key":"6144_CR87","doi-asserted-by":"publisher","first-page":"20160778","DOI":"10.1259\/bjr.20160778","volume":"90","author":"J Aissa","year":"2017","unstructured":"Aissa J, Boos J, Sawicki LM et al (2017) Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms. Br J Radiol 90:20160778","journal-title":"Br J Radiol"},{"key":"6144_CR88","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/j.jacep.2022.10.012","volume":"9","author":"JP Moore","year":"2023","unstructured":"Moore JP, de Groot NMS, O\u2019Connor M et al (2023) Conduction system pacing versus conventional cardiac resynchronization therapy in congenital heart disease. JACC Clin Electrophysiol 9:385\u2013393","journal-title":"JACC Clin Electrophysiol"},{"key":"6144_CR89","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.122.011447","volume":"16","author":"MJ Shah","year":"2023","unstructured":"Shah MJ, Borquez AA, Cortez D et al (2023) Transcatheter leadless pacing in children: a PACES Collaborative Study in the real-world setting. Circ Arrhythm Electrophysiol 16:e011447","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"6144_CR90","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1007\/s00508-018-1334-z","volume":"130","author":"C Edlinger","year":"2018","unstructured":"Edlinger C, Granitz M, Paar V et al (2018) Visualization and appearance of artifacts of leadless pacemaker systems in cardiac MRI: an experimental ex vivo study. Wien Klin Wochenschr 130:427\u2013435","journal-title":"Wien Klin Wochenschr"},{"key":"6144_CR91","doi-asserted-by":"publisher","first-page":"2407","DOI":"10.1161\/CIRCULATIONAHA.112.000112","volume":"128","author":"FW Prinzen","year":"2013","unstructured":"Prinzen FW, Vernooy K, Auricchio A (2013) Cardiac resynchronization therapy: state-of-the-art of current applications, guidelines, ongoing trials, and areas of controversy. Circulation 128:2407\u20132418","journal-title":"Circulation"},{"key":"6144_CR92","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1038\/nrcardio.2014.67","volume":"11","author":"K Vernooy","year":"2014","unstructured":"Vernooy K, van Deursen CJ, Strik M, Prinzen FW (2014) Strategies to improve cardiac resynchronization therapy. Nat Rev Cardiol 11:481\u2013493","journal-title":"Nat Rev Cardiol"},{"key":"6144_CR93","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.ijcard.2019.01.051","volume":"286","author":"AMW van Stipdonk","year":"2019","unstructured":"van Stipdonk AMW, Vanbelle S, Ter Horst IAH et al (2019) Large variability in clinical judgement and definitions of left bundle branch block to identify candidates for cardiac resynchronisation therapy. Int J Cardiol 286:61\u201365","journal-title":"Int J Cardiol"},{"key":"6144_CR94","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.jacep.2019.10.009","volume":"6","author":"AMW van Stipdonk","year":"2020","unstructured":"van Stipdonk AMW, Hoogland R, Ter Horst I et al (2020) Evaluating electrocardiography-based identification of cardiac resynchronization therapy responders beyond current left bundle branch block definitions. JACC Clin Electrophysiol 6:193\u2013203","journal-title":"JACC Clin Electrophysiol"},{"key":"6144_CR95","doi-asserted-by":"publisher","first-page":"e012363","DOI":"10.1161\/CIRCEP.123.012363","volume":"17","author":"NL Ramdat Misier","year":"2024","unstructured":"Ramdat Misier NL, Moore JP, Nguyen HH et al (2024) Long-term outcomes of cardiac resynchronization therapy in patients with repaired tetralogy of fallot: a multicenter study. Circ Arrhythm Electrophysiol 17:e012363","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"6144_CR96","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1016\/j.hrthm.2017.04.041","volume":"14","author":"JM Behar","year":"2017","unstructured":"Behar JM, Rajani R, Pourmorteza A et al (2017) Comprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapy. Heart Rhythm 14:1364\u20131372","journal-title":"Heart Rhythm"},{"key":"6144_CR97","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1111\/jce.14896","volume":"32","author":"J Gould","year":"2021","unstructured":"Gould J, Sidhu BS, Sieniewicz BJ et al (2021) Feasibility of intraprocedural integration of cardiac CT to guide left ventricular lead implantation for CRT upgrades. J Cardiovasc Electrophysiol 32:802\u2013812","journal-title":"J Cardiovasc Electrophysiol"},{"key":"6144_CR98","doi-asserted-by":"publisher","first-page":"e014165","DOI":"10.1161\/CIRCIMAGING.122.014165","volume":"15","author":"A Manohar","year":"2022","unstructured":"Manohar A, Colvert GM, Yang J et al (2022) Prediction of cardiac resynchronization therapy response using a lead placement score derived from 4-dimensional computed tomography. Circ Cardiovasc Imaging 15:e014165","journal-title":"Circ Cardiovasc Imaging"},{"key":"6144_CR99","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1017\/S1047951115000190","volume":"26","author":"N Al-Wakeel","year":"2016","unstructured":"Al-Wakeel N, Oh-I D, Schmitt KR et al (2016) Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system. Cardiol Young 26:306\u2013314","journal-title":"Cardiol Young"},{"key":"6144_CR100","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1111\/j.1540-8159.2009.02304.x","volume":"32","author":"AF Pulver","year":"2009","unstructured":"Pulver AF, Puchalski MD, Bradley DJ et al (2009) Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers. Pacing Clin Electrophysiol 32:450\u2013456","journal-title":"Pacing Clin Electrophysiol"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-024-06144-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-024-06144-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-024-06144-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:02:50Z","timestamp":1762498970000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-024-06144-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,21]]},"references-count":100,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,10]]}},"alternative-id":["6144"],"URL":"https:\/\/doi.org\/10.1007\/s00247-024-06144-8","relation":{},"ISSN":["1432-1998"],"issn-type":[{"type":"electronic","value":"1432-1998"}],"subject":[],"published":{"date-parts":[[2025,1,21]]},"assertion":[{"value":"3 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 December 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}