{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T00:57:09Z","timestamp":1792717029116,"version":"4.5.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T00:00:00Z","timestamp":1745625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T00:00:00Z","timestamp":1745625600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"DOI":"10.1007\/s00247-025-06222-5","type":"journal-article","created":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T07:54:30Z","timestamp":1745654070000},"page":"1270-1280","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Influence of anti-scatter grids on radiation dose and image quality in cardiac catheterization of children weighing less than 10 kg"],"prefix":"10.1007","volume":"55","author":[{"given":"Naoki","family":"Hashimoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayako","family":"Kuraoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichiro","family":"Yamamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Sagawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saki","family":"Hashimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Urabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joji","family":"Hashimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Mizumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masako","family":"Hiroshima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasunori","family":"Tateishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,26]]},"reference":[{"key":"6222_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.9794\/jspccs.37.27","volume":"37","author":"T Tanaka","year":"2021","unstructured":"Tanaka T (2021) Radiation exposure in pediatric cardiac catheterization: invisible complications. Ped Cardiol Card Surg 37:27\u201328","journal-title":"Ped Cardiol Card Surg"},{"key":"6222_CR2","first-page":"645","volume":"10","author":"E Shelly","year":"2023","unstructured":"Shelly E, Waldron MG, Field E et al (2023) Cumulative radiation dose from medical imaging in children with congenital heart disease: a systematic review. Children (Basel) 10:645","journal-title":"Children (Basel)"},{"key":"6222_CR3","doi-asserted-by":"publisher","first-page":"2703","DOI":"10.1093\/eurheartj\/ehl014","volume":"27","author":"MG Andreassi","year":"2006","unstructured":"Andreassi MG, Ait-Ali L, Botto N et al (2006) Cardiac catheterization and long-term chromosomal damage in children with congenital heart disease. Eur Heart J 27:2703\u20132708","journal-title":"Eur Heart J"},{"key":"6222_CR4","doi-asserted-by":"publisher","first-page":"503163","DOI":"10.1016\/j.mrgentox.2020.503163","volume":"852","author":"Y Gao","year":"2020","unstructured":"Gao Y, Wang P, Su Y et al (2020) Cardiac catheterization procedures in children with congenital heart disease: increased chromosomal aberrations in peripheral lymphocytes. Mutat Res Genet Toxicol Environ Mutagen 852:503163","journal-title":"Mutat Res Genet Toxicol Environ Mutagen"},{"key":"6222_CR5","first-page":"1154","volume":"115","author":"JL Manica","year":"2020","unstructured":"Manica JL, Duarte VO, Ribeiro M et al (2020) Standardizing radiation exposure during cardiac catheterization in children with congenital heart disease: data from a multicenter Brazilian registry. Arq Bras Cardio 115:1154\u20131161","journal-title":"Arq Bras Cardio"},{"key":"6222_CR6","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1007\/s00247-006-0194-2","volume":"36","author":"H Justino","year":"2006","unstructured":"Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36:146\u2013153","journal-title":"Pediatr Radiol"},{"key":"6222_CR7","doi-asserted-by":"crossref","unstructured":"Boothroyd A, McDonald E, Moores BM et al (1997) Radiation exposure to children during cardiac catheterization.\u00a0Br J Radiol\u00a070:180\u20135","DOI":"10.1259\/bjr.70.830.9135445"},{"issue":"62","key":"6222_CR8","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.6009\/jjrt.62.1119","volume":"20","author":"C Kawabata","year":"2006","unstructured":"Kawabata C, Koshida K, Hayakawa M et al (2006) Estimation of the effective dose of patient in interventional radiology: study of coronary angiography. Jpn J Radiol Technol 20(62):1119\u201326","journal-title":"Jpn J Radiol Technol"},{"key":"6222_CR9","unstructured":"National diagnostic reference levels in Japan (2020) https:\/\/j-rime.qst.go.jp\/report\/DRL2020_Engver.pdf. Accessed 3 March 2025"},{"key":"6222_CR10","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/S0146-6453(00)00026-9","volume":"30","author":"J Valentin","year":"2000","unstructured":"Valentin J (2000) Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30:7\u201367","journal-title":"Ann ICRP"},{"key":"6222_CR11","doi-asserted-by":"publisher","first-page":"4863","DOI":"10.1088\/0031-9155\/52\/16\/010","volume":"52","author":"MJ Tapiovaara","year":"2007","unstructured":"Tapiovaara MJ, Sandborg M, Fetterly KA, Schueler BA (2007) Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital X-ray systems. Phys Med Biol 52:4863\u201380","journal-title":"Phys Med Biol"},{"key":"6222_CR12","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1088\/0031-9155\/40\/4\/007","volume":"40","author":"MJ Tapiovaara","year":"1995","unstructured":"Tapiovaara MJ, Sandborg M (1995) Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations. Phys Med Biol 40:589\u2013607","journal-title":"Phys Med Biol"},{"key":"6222_CR13","doi-asserted-by":"crossref","unstructured":"Osei FA, Hayman J, Sutton NJ, Pass RH (2016) Radiation dosage during pediatric diagnostic or interventional cardiac catheterizations using the \u201cair gap technique\u201d and an aggressive \u201cas low as reasonably achievable\u201d radiation reduction protocol in patients weighing <20 kg. Ann Pediatr Cardiol 9:16-21","DOI":"10.4103\/0974-2069.171406"},{"key":"6222_CR14","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1016\/j.jcmg.2017.04.003","volume":"10","author":"KD Hill","year":"2017","unstructured":"Hill KD, Frush DP, Han BK et al (2017) Radiation safety in children with congenital and acquired heart disease: a scientific position statement on multimodality dose optimization from the Image Gently Alliance. JACC Cardiovasc Imaging 10:797\u2013818","journal-title":"JACC Cardiovasc Imaging"},{"key":"6222_CR15","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1002\/ccd.24602","volume":"82","author":"C Ubeda","year":"2013","unstructured":"Ubeda C, Vano E, Gonzalez L, Miranda P (2013) Influence of the antiscatter grid on dose and image quality in pediatric interventional cardiology X-ray systems. Catheter Cardiovasc Interv. 82:51\u20137","journal-title":"Catheter Cardiovasc Interv."},{"key":"6222_CR16","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1259\/0007-1285-22-261-549-b","volume":"22","author":"DEA Jones","year":"1949","unstructured":"Jones DEA, Raine HC (1949) Correspondence. Br J Radiol 22:549\u2013550","journal-title":"Br J Radiol"},{"key":"6222_CR17","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1038\/nmeth.2089","volume":"9","author":"CA Schneider","year":"2012","unstructured":"Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9:671\u2013675","journal-title":"Nat Methods"},{"key":"6222_CR18","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1002\/ccd.26630","volume":"89","author":"KD Hill","year":"2017","unstructured":"Hill KD, Wang C, Einstein AJ et al (2017) Impact of imaging approach on radiation dose and associated cancer risk in children undergoing cardiac catheterization. Catheter Cardiovasc Interv 89:888\u2013897","journal-title":"Catheter Cardiovasc Interv"},{"key":"6222_CR19","doi-asserted-by":"publisher","first-page":"1474","DOI":"10.1017\/S1047951119002506","volume":"29","author":"RC Chamberlain","year":"2019","unstructured":"Chamberlain RC, Shindhelm AC, Wang C et al (2019) Estimating radiation exposure during pediatric cardiac catheterization: a potential for radiation reduction with air gap technique. Cardiol Young 29:1474\u20131480","journal-title":"Cardiol Young"},{"key":"6222_CR20","unstructured":"Nakamae M\u00a0(2014) Understanding of image quality; that\u2019s why determinable exposure condition. Jpan J Radiol Technol 22:28\u201329"},{"key":"6222_CR21","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1136\/hrt.2005.063909","volume":"92","author":"J Partridge","year":"2006","unstructured":"Partridge J, McGahan G, Causton S et al (2006) Radiation dose reduction without compromise of image quality in cardiac angiography and intervention with the use of a flat panel detector without an antiscatter grid. Heart 92:507\u2013510","journal-title":"Heart"},{"key":"6222_CR22","doi-asserted-by":"publisher","first-page":"41","DOI":"10.6009\/jjrt.64.41","volume":"64","author":"S Sakai","year":"2008","unstructured":"Sakai S, Katayama R, Morisita J et al (2008) Comparison of basic imaging properties for digital radiographic systems based on a direct conversion type of flat panel detector. Jpn J Radiol Technol 64:41\u201349","journal-title":"Jpn J Radiol Technol"},{"key":"6222_CR23","first-page":"300","volume":"26","author":"T Fujii","year":"2010","unstructured":"Fujii T, Mori Y, Kishi K et al (2010) Development of systemic venous collateral channels after the Fontan procedures. Ped Cardiol Card Surg 26:300\u2013307","journal-title":"Ped Cardiol Card Surg"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-025-06222-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-025-06222-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-025-06222-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,28]],"date-time":"2025-05-28T09:51:48Z","timestamp":1748425908000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-025-06222-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,26]]},"references-count":23,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,5]]}},"alternative-id":["6222"],"URL":"https:\/\/doi.org\/10.1007\/s00247-025-06222-5","relation":{},"ISSN":["1432-1998"],"issn-type":[{"value":"1432-1998","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,26]]},"assertion":[{"value":"25 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}