{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T21:31:58Z","timestamp":1792877518793,"version":"4.5.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T00:00:00Z","timestamp":1774310400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T00:00:00Z","timestamp":1774310400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Fast magnetic resonance imaging (MRI) acquisitions with high frame rates can mitigate artefacts caused by physiological motion and bulk patient movement, enabling motion-resolved imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aims to evaluate the detection performance of triplanar real-time cine fast imaging employing steady-state acquisition (FIESTA), compared to conventional MRI sequences.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>This retrospective study included 53 children (median age, 1.9\u00a0years; range, 1\u00a0day\u20137.1\u00a0years) who underwent clinically indicated 1.5-T chest MRI in sedation between January and December 2024. Findings on triplanar real-time cine FIESTA sequences, acquired in up to 1 min, were compared to the findings obtained by dedicated lung sequences (fast spin echo, zero echo time, perfusion imaging) as reference. Detection of extrapulmonary findings (of the chest wall, diaphragm, pleura, mediastinum), lung parenchymal findings (consolidation, atelectasis, bronchial wall thickening, hyperinflation, cysts), and cardiovascular findings by real-time cine FIESTA are presented with descriptive statistics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Real-time MRI provided diagnostic, motion-artefact-free thoracic images in the sedated but freely breathing patients. Diaphragmatic motion abnormalities were detected in one out of one case (100%), visible only on real-time cine FIESTA and not on the dedicated static sequences. Pleural effusion was present in 16 out of 17 cases (94%), and mediastinal masses were present in five out of five cases (100%). Lung pathologies, including consolidation and atelectasis, were identified in 40 out of 44 cases (91%). However, bronchial wall thickening was missed in all 20 cases (0%). Hyperinflation or air-filled cysts were detected in four out of four  cases (100%). Cardiovascular abnormalities were identified in six out of eight cases (75%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Real-time cine FIESTA imaging demonstrated high accuracy in detecting pleural effusion, pulmonary consolidation, cysts, and gross cardiovascular abnormalities in paediatric patients. However, airway pathologies were not identified. Clinical indications for real-time cine chest MRI need to be defined. Feasibility and performance of real-time imaging in unsedated children warrant further study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00247-026-06596-0","type":"journal-article","created":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T06:52:29Z","timestamp":1774335149000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Diagnostic performance of triplanar real-time chest magnetic resonance imaging in preschool children - comparison with dedicated lung magnetic resonance imaging"],"prefix":"10.1007","author":[{"given":"Michael","family":"Zellner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Geiger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rahel","family":"Heule","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Selma","family":"Sirin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Srdjan","family":"Micic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elias","family":"Seidl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Moeller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian J.","family":"Kellenberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,24]]},"reference":[{"key":"6596_CR1","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1002\/nbm.1585","volume":"23","author":"M Uecker","year":"2010","unstructured":"Uecker M, Zhang S, Voit D et al (2010) Real-time MRI at a resolution of 20 ms. NMR Biomed 23:986\u2013994","journal-title":"NMR Biomed"},{"key":"6596_CR2","doi-asserted-by":"publisher","first-page":"3405","DOI":"10.1007\/s00431-023-04996-0","volume":"182","author":"FW Hirsch","year":"2023","unstructured":"Hirsch FW, Frahm J, Sorge I et al (2023) Real-time MRI: a new tool of radiologic imaging in small children. Eur J Pediatr 182:3405\u20133417.","journal-title":"Eur J Pediatr"},{"key":"6596_CR3","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1007\/s00247-022-05421-8","volume":"53","author":"FW Hirsch","year":"2023","unstructured":"Hirsch FW, Sorge I, Voit D et al (2023) Chest examinations in children with real-time magnetic resonance imaging: first clinical experience. Pediatr Radiol 53:12\u201320.","journal-title":"Pediatr Radiol"},{"key":"6596_CR4","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.71133","volume":"60","author":"FW Hirsch","year":"2025","unstructured":"Hirsch FW, Sorge I, Roth C et al (2025) Real-time MRI of the chest wall, diaphragm, and lungs in children. Pediatr Pulmonol 60:e71133","journal-title":"Pediatr Pulmonol"},{"key":"6596_CR5","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1007\/s00247-022-05327-5","volume":"52","author":"LM R\u00f6wer","year":"2022","unstructured":"R\u00f6wer LM, Radke KL, Hu\u00dfmann J et al (2022) Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children. Pediatr Radiol 52:1462\u20131475.","journal-title":"Pediatr Radiol"},{"key":"6596_CR6","doi-asserted-by":"publisher","first-page":"1652","DOI":"10.1002\/mrm.28029","volume":"83","author":"D Voit","year":"2020","unstructured":"Voit D, Kalentev O, van Zalk M et al (2020) Rapid and motion-robust volume coverage using cross-sectional real-time MRI. Magn Reson Med 83:1652\u20131658.","journal-title":"Magn Reson Med"},{"key":"6596_CR7","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1007\/s00247-022-05298-7","volume":"52","author":"LP Browne","year":"2022","unstructured":"Browne LP, Malone LJ, Englund EK et al (2022) Free-breathing magnetic resonance imaging with radial k-space sampling for neonates and infants to reduce anesthesia. Pediatr Radiol 52:1326\u20131337.","journal-title":"Pediatr Radiol"},{"key":"6596_CR8","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1007\/s00247-019-04594-z","volume":"50","author":"FW Hirsch","year":"2020","unstructured":"Hirsch FW, Sorge I, Vogel-Claussen J et al (2020) The current status and further prospects for lung magnetic resonance imaging in pediatric radiology. Pediatr Radiol 50:734\u2013749.","journal-title":"Pediatr Radiol"},{"key":"6596_CR9","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1055\/a-1561-2430","volume":"194","author":"I Sorge","year":"2022","unstructured":"Sorge I, Hirsch FW, Voit D et al (2022) Decreased need for anesthesia during ultra-fast cranial MRI in\u00a0young children: one-year summary. Rofo 194:192\u2013198.","journal-title":"Rofo"},{"key":"6596_CR10","doi-asserted-by":"publisher","DOI":"10.21037\/qims-23-923","volume":"13","author":"D Voit","year":"2023","unstructured":"Voit D, Kollmeier JM, Kalentev O et al (2023) Whole-body magnetic resonance imaging in two minutes: cross-sectional real-time coverage of multiple volumes. Quant Imaging Med Surg 13:8739746\u20138738746.","journal-title":"Quant Imaging Med Surg"},{"key":"6596_CR11","doi-asserted-by":"publisher","first-page":"2128","DOI":"10.1007\/s00330-022-09197-1","volume":"33","author":"D Gr\u00e4fe","year":"2023","unstructured":"Gr\u00e4fe D, Lacher M, Martynov I et al (2023) Pectus excavatum in motion: dynamic evaluation using real-time MRI. Eur Radiol 33:2128\u20132135.","journal-title":"Eur Radiol"},{"key":"6596_CR12","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1007\/s00247-020-04828-5","volume":"51","author":"FW Hirsch","year":"2021","unstructured":"Hirsch FW, Frahm J, Sorge I et al (2021) Real-time magnetic resonance imaging in pediatric radiology - new approach to movement and moving children. Pediatr Radiol 51:840\u2013846.","journal-title":"Pediatr Radiol"},{"key":"6596_CR13","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1093\/oxfordjournals.bja.a013586","volume":"84","author":"S Malviya","year":"2000","unstructured":"Malviya S, Voepel-Lewis T, Eldevik OP et al (2000) Sedation and general anaesthesia in children undergoing MRI and CT: adverse events and outcomes. Br J Anaesth 84:743\u2013748.","journal-title":"Br J Anaesth"},{"key":"6596_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.braindev.2024.104311","volume":"47","author":"M Uramatsu","year":"2025","unstructured":"Uramatsu M, Takahashi H, Barach P et al (2025) Improving pediatric magnetic resonance imaging safety by enhanced non-technical skills and team collaboration. Brain Dev 47:104311.","journal-title":"Brain Dev"},{"key":"6596_CR15","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.1002\/jmri.28392","volume":"57","author":"MD Mallory","year":"2023","unstructured":"Mallory MD, Travers C, Cravero JP et al (2023) Pediatric sedation\/anesthesia for MRI: results from the Pediatric Sedation Research Consortium. J Magn Reson Imaging 57:1106\u20131113","journal-title":"J Magn Reson Imaging"},{"key":"6596_CR16","doi-asserted-by":"publisher","first-page":"747","DOI":"10.2214\/AJR.22.28490","volume":"220","author":"SE Hayatghaibi","year":"2023","unstructured":"Hayatghaibi SE, Cazaban CG, Chan SS et al (2023) Pediatric outpatient noncontrast brain MRI: a time-driven activity-based costing analysis at three U.S. hospitals. AJR Am J Roentgenol 220:747\u2013756.","journal-title":"AJR Am J Roentgenol"},{"key":"6596_CR17","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1007\/s00247-020-04658-5","volume":"50","author":"CJ Kellenberger","year":"2020","unstructured":"Kellenberger CJ, Amaxopoulou C, Moehrlen U et al (2020) Structural and perfusion magnetic resonance imaging of congenital lung malformations. Pediatr Radiol 50:1083\u20131094.","journal-title":"Pediatr Radiol"},{"key":"6596_CR18","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1007\/s00247-022-05504-6","volume":"53","author":"CJ Kellenberger","year":"2023","unstructured":"Kellenberger CJ, Lovrenski J, Semple T, Caro-Dom\u00ednguez P (2023) Neonatal cardiorespiratory imaging-a multimodality state-of-the-art review. Pediatr Radiol 53:660\u2013676","journal-title":"Pediatr Radiol"},{"key":"6596_CR19","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163","journal-title":"J Chiropr Med"},{"key":"6596_CR20","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-15-79","volume":"15","author":"D Voit","year":"2013","unstructured":"Voit D, Zhang S, Unterberg-Buchwald C et al (2013) Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolution. J Cardiovasc Magn Reson 15:79","journal-title":"J Cardiovasc Magn Reson"},{"key":"6596_CR21","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1002\/mrm.25665","volume":"75","author":"L Feng","year":"2016","unstructured":"Feng L, Axel L, Chandarana H et al (2016) XD-GRASP: golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing. Magn Reson Med 75:775\u2013788.","journal-title":"Magn Reson Med"},{"key":"6596_CR22","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182\u20131195","journal-title":"Magn Reson Med"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-026-06596-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-026-06596-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-026-06596-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:07:05Z","timestamp":1791824825000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-026-06596-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,24]]},"references-count":22,"alternative-id":["6596"],"URL":"https:\/\/doi.org\/10.1007\/s00247-026-06596-0","relation":{},"ISSN":["1432-1998"],"issn-type":[{"value":"1432-1998","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,24]]},"assertion":[{"value":"12 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2026","order":6,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":7,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This article was originally published under the subscription model but it is now published under an Open Access license.","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All patients\/legal guardians had provided a general consent permitting secondary research use of clinical data. Retrospective pseudonymized data analysis for this study was approved by the local ethics committee\u00a0(BASEC 2017-01199).","order":1,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None.","order":2,"name":"Ethics","label":"Conflicts of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}