{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T11:03:44Z","timestamp":1789470224973,"version":"build-2803163510"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Radiol"],"DOI":"10.1007\/s00247-026-06668-1","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T08:19:38Z","timestamp":1779956378000},"page":"2238-2248","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Super-resolution deep learning reconstruction achieves low-dose high-resolution imaging in pediatric cardiac computed tomography"],"prefix":"10.1007","volume":"56","author":[{"given":"Haruka","family":"Obinata","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyohiro","family":"Takigiku","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kosuke","family":"Yonehara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuma","family":"Shibuya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yohei","family":"Akazawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohta","family":"Takei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Miyazawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taro","family":"Sakashita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"6668_CR1","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1111\/echo.13147","volume":"33","author":"A Kulkarni","year":"2016","unstructured":"Kulkarni A, Hsu HH, Ou P et al (2016) Computed tomography in congenital heart disease: clinical applications and technical considerations. Echocardiography 33:629\u2013640","journal-title":"Echocardiography"},{"key":"6668_CR2","unstructured":"UNSCEAR (2010) Sources and effects of ionizing radiation. UNSCEAR 2008 Report to the General Assembly, with Scientific Annexes. Volume I: Sources (Report, Annexes A and B). United Nations, New York\u00a0"},{"key":"6668_CR3","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.jcct.2009.05.013","volume":"3","author":"J Hoe","year":"2009","unstructured":"Hoe J, Toh KH (2009) First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose. J Cardiovasc Comput Tomogr 3:257\u2013261","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"6668_CR4","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1161\/CIRCULATIONAHA.109.859280","volume":"120","author":"M Dewey","year":"2009","unstructured":"Dewey M, Zimmermann E, Deissenrieder F et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867\u2013875","journal-title":"Circulation"},{"key":"6668_CR5","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1364\/BOE.8.000679","volume":"8","author":"H Chen","year":"2017","unstructured":"Chen H, Zhang Y, Zhang W et al (2017) Low-dose CT via convolutional neural network. Biomed Opt Express 8:679\u2013694","journal-title":"Biomed Opt Express"},{"key":"6668_CR6","unstructured":"Boedeker K (2019) AiCE deep learning reconstruction: bringing the power of ultra-high resolution CT to routine imaging. https:\/\/global.medical.canon\/publication\/ct\/2019WP_AiCE_Deep_Learning.html. Accessed 24 Feb 2026"},{"key":"6668_CR7","unstructured":"Boedeker K (2021) Precision-trained deep learning: redefining cardiac imaging. https:\/\/global.medical.canon\/publication\/ct\/MWPCT0008EA. Accessed 24 Feb 2026"},{"key":"6668_CR8","doi-asserted-by":"publisher","first-page":"2870","DOI":"10.21037\/qims-23-1204","volume":"14","author":"S Sawamura","year":"2024","unstructured":"Sawamura S, Kato S, Funama Y et al (2024) Evaluation of four computed tomography reconstruction algorithms using a coronary artery phantom. Quantitative Imaging in Medicine and Surgery 14:2870\u20132883","journal-title":"Quantitative Imaging in Medicine and Surgery"},{"key":"6668_CR9","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.diii.2023.10.004","volume":"105","author":"J Greffier","year":"2024","unstructured":"Greffier J, Pastor M, Si-Mohamed S et al (2024) Comparison of two deep-learning image reconstruction algorithms on cardiac CT images: a phantom study. Diagn Interv Imaging 105:110\u2013117","journal-title":"Diagn Interv Imaging"},{"key":"6668_CR10","volume":"5","author":"M Takafuji","year":"2023","unstructured":"Takafuji M, Kitagawa K, Mizutani S et al (2023) Super-resolution deep learning reconstruction for improved image quality of coronary CT angiography. Radiology: Cardiothoracic Imaging 5:e230085","journal-title":"Radiology: Cardiothoracic Imaging"},{"key":"6668_CR11","doi-asserted-by":"publisher","first-page":"8488","DOI":"10.1007\/s00330-023-09888-3","volume":"33","author":"Y Nagayama","year":"2023","unstructured":"Nagayama Y, Emoto T, Kato Y et al (2023) Improving image quality with super\u2011resolution deep\u2011learning\u2011based reconstruction in coronary CT angiography. Eur Radiol 33:8488\u20138500","journal-title":"Eur Radiol"},{"key":"6668_CR12","doi-asserted-by":"publisher","first-page":"1663","DOI":"10.1007\/s00247-016-3676-x","volume":"46","author":"Y Nishiyama","year":"2016","unstructured":"Nishiyama Y, Tada K, Nishiyama Y et al (2016) Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography. Pediatr Radiol 46:1663\u20131670","journal-title":"Pediatr Radiol"},{"key":"6668_CR13","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1088\/0031-9155\/32\/5\/003","volume":"32","author":"MF Kijewski","year":"1987","unstructured":"Kijewski MF, Judy PF (1987) The noise power spectrum of CT images. Phys Med Biol 32:565\u2013575","journal-title":"Phys Med Biol"},{"key":"6668_CR14","doi-asserted-by":"publisher","first-page":"4115","DOI":"10.1118\/1.4725171","volume":"39","author":"S Richard","year":"2012","unstructured":"Richard S, Husarik DB, Yadava G et al (2012) Toward task-based assessment of CT performance: system and object MTF across different reconstruction algorithms. Med Phys 39:4115\u20134122","journal-title":"Med Phys"},{"key":"6668_CR15","first-page":"1","volume":"37","author":"J Valentin","year":"2007","unstructured":"Valentin J (2007) International Commission on Radiation Protection: managing patient dose in multi-detector computed tomography (MDCT). ICRP publication 102. Ann ICRP 37:1\u201379","journal-title":"Ann ICRP"},{"key":"6668_CR16","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/s11604-018-0796-2","volume":"37","author":"T Higaki","year":"2019","unstructured":"Higaki T, Nakamura Y, Tatsugami F et al (2019) Improvement of image quality at CT and MRI using deep learning. Jpn J Radiol 37:73\u201380","journal-title":"Jpn J Radiol"},{"key":"6668_CR17","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.acra.2019.09.008","volume":"27","author":"T Higaki","year":"2020","unstructured":"Higaki T, Nakamura Y, Zhou J et al (2020) Deep learning reconstruction at CT: phantom study of the image characteristics. Acad Radiol 27:82\u201387","journal-title":"Acad Radiol"},{"key":"6668_CR18","doi-asserted-by":"publisher","first-page":"5322","DOI":"10.1007\/s00330-019-06183-y","volume":"29","author":"F Tatsugami","year":"2019","unstructured":"Tatsugami F, Higaki T, Nakamura Y et al (2019) Deep learning\u2013based image restoration algorithm for coronary CT angiography. Eur Radiol 29:5322\u20135329","journal-title":"Eur Radiol"},{"key":"6668_CR19","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1007\/s00247-017-3901-2","volume":"47","author":"G Shirota","year":"2017","unstructured":"Shirota G, Maeda E, Namiki Y et al (2017) Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction. Pediatr Radiol 47:1463\u20131470","journal-title":"Pediatr Radiol"},{"key":"6668_CR20","doi-asserted-by":"publisher","first-page":"S122","DOI":"10.1001\/dmp.2011.21","volume":"5","author":"EB Douple","year":"2011","unstructured":"Douple EB, Mabuchi K, Cullings HM et al (2011) Long-term radiation-related health effects in a unique human population: lessons learned from the atomic bomb survivors of Hiroshima and Nagasaki. Disaster Med Public Health Prep 5:S122\u2013S133","journal-title":"Disaster Med Public Health Prep"},{"key":"6668_CR21","unstructured":"Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, National Research Council (2006). Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase2. Washington DC: National Academy of Sciences. https:\/\/www.philrutherford.com\/Radiation_Risk\/BEIR\/BEIR_VII.pdf. Accessed 24 Feb 2026"},{"key":"6668_CR22","unstructured":"Japan Network for Research and Information on Medical Exposure (J-RIME). National diagnostic reference levels in Japan (2020) -Japan DRLs 2020-. https:\/\/j-rime.qst.go.jp\/report\/DRL2020_Engver.pdf. Accessed 24 Feb 2025"}],"container-title":["Pediatric Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-026-06668-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00247-026-06668-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00247-026-06668-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T10:17:27Z","timestamp":1789467447000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00247-026-06668-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":22,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["6668"],"URL":"https:\/\/doi.org\/10.1007\/s00247-026-06668-1","relation":{},"ISSN":["1432-1998"],"issn-type":[{"value":"1432-1998","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"assertion":[{"value":"13 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"D.M. and T.S. are employees of Canon Medical Systems. The remaining authors have no financial interests.","order":1,"name":"Ethics","label":"Conflicts of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}