{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T20:30:37Z","timestamp":1759177837422},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2014,8,28]],"date-time":"2014-08-28T00:00:00Z","timestamp":1409184000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Skeletal Radiol"],"published-print":{"date-parts":[[2014,12]]},"DOI":"10.1007\/s00256-014-1986-3","type":"journal-article","created":{"date-parts":[[2014,8,27]],"date-time":"2014-08-27T02:42:38Z","timestamp":1409107358000},"page":"1705-1712","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws"],"prefix":"10.1007","volume":"43","author":[{"given":"Lukas","family":"Filli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magda","family":"Marcon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Scholz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurizio","family":"Calcagni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tim","family":"Finkenst\u00e4dt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gustav","family":"Andreisek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roman","family":"Guggenberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,8,28]]},"reference":[{"issue":"1","key":"1986_CR1","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ocl.2012.09.003","volume":"44","author":"R Sendher","year":"2013","unstructured":"Sendher R, Ladd AL. The scaphoid. Orthop Clin North Am. 2013;44(1):107\u201320. doi: 10.1016\/j.ocl.2012.09.003 .","journal-title":"Orthop Clin North Am"},{"issue":"1","key":"1986_CR2","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1177\/230949901202000112","volume":"20","author":"KO Oduwole","year":"2012","unstructured":"Oduwole KO, Cichy B, Dillon JP, Wilson J, O\u2019Beirne J. Acutrak versus Herbert screw fixation for scaphoid non-union and delayed union. J Orthop Surg (Hong Kong). 2012;20(1):61\u20135.","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"8","key":"1986_CR3","doi-asserted-by":"crossref","first-page":"474","DOI":"10.5435\/00124635-200708000-00004","volume":"15","author":"AP Gutow","year":"2007","unstructured":"Gutow AP. Percutaneous fixation of scaphoid fractures. J Am Acad Orthop Surg. 2007;15(8):474\u201385.","journal-title":"J Am Acad Orthop Surg"},{"issue":"3","key":"1986_CR4","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.jhsa.2005.01.001","volume":"30","author":"CL Temple","year":"2005","unstructured":"Temple CL, Ross DC, Bennett JD, Garvin GJ, King GJ, Faber KJ. Comparison of sagittal computed tomography and plain film radiography in a scaphoid fracture model. J Hand Surg. 2005;30(3):534\u201342. doi: 10.1016\/j.jhsa.2005.01.001 .","journal-title":"J Hand Surg"},{"issue":"12","key":"1986_CR5","doi-asserted-by":"crossref","first-page":"2695","DOI":"10.2106\/JBJS.E.01211","volume":"88","author":"S Lozano-Calderon","year":"2006","unstructured":"Lozano-Calderon S, Blazar P, Zurakowski D, Lee SG, Ring D. Diagnosis of scaphoid fracture displacement with radiography and computed tomography. J Bone Joint Surg Am Volume. 2006;88(12):2695\u2013703. doi: 10.2106\/JBJS.E.01211 .","journal-title":"J Bone Joint Surg Am Volume"},{"issue":"1\u20132","key":"1986_CR6","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1111\/j.1445-2197.2009.05204.x","volume":"80","author":"M Smith","year":"2010","unstructured":"Smith M, Bain GI, Turner PC, Watts AC. Review of imaging of scaphoid fractures. ANZ J Surg. 2010;80(1\u20132):82\u201390. doi: 10.1111\/j.1445-2197.2009.05204.x .","journal-title":"ANZ J Surg"},{"issue":"11","key":"1986_CR7","doi-asserted-by":"crossref","first-page":"2767","DOI":"10.1007\/s00330-007-0651-9","volume":"17","author":"WA Kalender","year":"2007","unstructured":"Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol. 2007;17(11):2767\u201379. doi: 10.1007\/s00330-007-0651-9 .","journal-title":"Eur Radiol"},{"issue":"10","key":"1986_CR8","doi-asserted-by":"crossref","first-page":"1930","DOI":"10.3174\/ajnr.A1237","volume":"29","author":"Y Kyriakou","year":"2008","unstructured":"Kyriakou Y, Richter G, Dorfler A, Kalender WA. Neuroradiologic applications with routine C-arm flat panel detector CT: evaluation of patient dose measurements. AJNR Am J Neuroradiol. 2008;29(10):1930\u20136. doi: 10.3174\/ajnr.A1237 .","journal-title":"AJNR Am J Neuroradiol"},{"issue":"7","key":"1986_CR9","doi-asserted-by":"crossref","first-page":"2009","DOI":"10.1148\/rg.287085004","volume":"28","author":"R Gupta","year":"2008","unstructured":"Gupta R, Cheung AC, Bartling SH, et al. Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics. 2008;28(7):2009\u201322. doi: 10.1148\/rg.287085004 .","journal-title":"Radiographics"},{"issue":"21","key":"1986_CR10","doi-asserted-by":"crossref","first-page":"6575","DOI":"10.1088\/0031-9155\/54\/21\/009","volume":"54","author":"D Prell","year":"2009","unstructured":"Prell D, Kyriakou Y, Beister M, Kalender WA. A novel forward projection-based metal artifact reduction method for flat-detector computed tomography. Phys Med Biol. 2009;54(21):6575\u201391. doi: 10.1088\/0031-9155\/54\/21\/009 .","journal-title":"Phys Med Biol"},{"issue":"8","key":"1986_CR11","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1007\/s00256-008-0630-5","volume":"38","author":"PT Liu","year":"2009","unstructured":"Liu PT, Pavlicek WP, Peter MB, Spangehl MJ, Roberts CC, Paden RG. Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress. Skeletal Radiol. 2009;38(8):797\u2013802. doi: 10.1007\/s00256-008-0630-5 .","journal-title":"Skeletal Radiol"},{"issue":"12","key":"1986_CR12","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1097\/01.rli.0000086495.96457.54","volume":"38","author":"AH Mahnken","year":"2003","unstructured":"Mahnken AH, Raupach R, Wildberger JE, et al. A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. Investig Radiol. 2003;38(12):769\u201375. doi: 10.1097\/01.rli.0000086495.96457.54 .","journal-title":"Investig Radiol"},{"issue":"11","key":"1986_CR13","doi-asserted-by":"crossref","first-page":"2357","DOI":"10.1007\/s00330-012-2501-7","volume":"22","author":"R Guggenberger","year":"2012","unstructured":"Guggenberger R, Winklhofer S, Osterhoff G, et al. Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels. Eur Radiol. 2012;22(11):2357\u201364. doi: 10.1007\/s00330-012-2501-7 .","journal-title":"Eur Radiol"},{"issue":"8","key":"1986_CR14","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/S1076-6332(00)80576-0","volume":"7","author":"G Wang","year":"2000","unstructured":"Wang G, Frei T, Vannier MW. Fast iterative algorithm for metal artifact reduction in X-ray CT. Acad Radiol. 2000;7(8):607\u201314.","journal-title":"Acad Radiol"},{"issue":"8","key":"1986_CR15","doi-asserted-by":"crossref","first-page":"2852","DOI":"10.1118\/1.2218062","volume":"33","author":"M Bal","year":"2006","unstructured":"Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys. 2006;33(8):2852\u20139.","journal-title":"Med Phys"},{"issue":"2","key":"1986_CR16","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1109\/TMI.2008.929103","volume":"28","author":"C Lemmens","year":"2009","unstructured":"Lemmens C, Faul D, Nuyts J. Suppression of metal artifacts in CT using a reconstruction procedure that combines MAP and projection completion. IEEE Trans Med Imaging. 2009;28(2):250\u201360. doi: 10.1109\/TMI.2008.929103 .","journal-title":"IEEE Trans Med Imaging"},{"issue":"4","key":"1986_CR17","doi-asserted-by":"crossref","first-page":"1904","DOI":"10.1118\/1.3691902","volume":"39","author":"E Meyer","year":"2012","unstructured":"Meyer E, Raupach R, Lell M, Schmidt B, Kachelriess M. Frequency split metal artifact reduction (FSMAR) in computed tomography. Med Phys. 2012;39(4):1904\u201316. doi: 10.1118\/1.3691902 .","journal-title":"Med Phys"},{"issue":"5","key":"1986_CR18","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1109\/42.538943","volume":"15","author":"G Wang","year":"1996","unstructured":"Wang G, Snyder DL, O\u2019Sullivan JA, Vannier MW. Iterative deblurring for CT metal artifact reduction. IEEE Trans Med Imaging. 1996;15(5):657\u201364. doi: 10.1109\/42.538943 .","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"1986_CR19","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1118\/1.3533711","volume":"38","author":"X Zhang","year":"2011","unstructured":"Zhang X, Wang J, Xing L. Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization. Med Phys. 2011;38(2):701\u201311.","journal-title":"Med Phys"},{"issue":"996","key":"1986_CR20","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1259\/bjr\/19113084","volume":"83","author":"D Prell","year":"2010","unstructured":"Prell D, Kalender WA, Kyriakou Y. Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT. Brit J Radiol. 2010;83(996):1052\u201362. doi: 10.1259\/bjr\/19113084 .","journal-title":"Brit J Radiol"},{"issue":"9","key":"1986_CR21","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1055\/s-0033-1350117","volume":"185","author":"JH Buhk","year":"2013","unstructured":"Buhk JH, Groth M, Sehner S, Fiehler J, Schmidt NO, Grzyska U. Application of a Novel Metal Artifact Correction Algorithm in Flat-Panel CT After Coil Embolization of Brain Aneurysms: Intraindividual Comparison. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2013;185(9):824\u20139. doi: 10.1055\/s-0033-1350117 .","journal-title":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin"},{"issue":"1","key":"1986_CR22","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159\u201374.","journal-title":"Biometrics"},{"issue":"9","key":"1986_CR23","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/j.jvir.2008.05.020","volume":"19","author":"S Suzuki","year":"2008","unstructured":"Suzuki S, Furui S, Yamaguchi I, et al. Entrance surface dose during three-dimensional imaging with a flat-panel detector angiography system. J Vasc Interv Radiol : JVIR. 2008;19(9):1361\u20135. doi: 10.1016\/j.jvir.2008.05.020 .","journal-title":"J Vasc Interv Radiol : JVIR"},{"issue":"6","key":"1986_CR24","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.2214\/AJR.09.2747","volume":"193","author":"K Chida","year":"2009","unstructured":"Chida K, Inaba Y, Saito H, et al. Radiation dose of interventional radiology system using a flat-panel detector. AJR Am J Roentgenol. 2009;193(6):1680\u20135. doi: 10.2214\/AJR.09.2747 .","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"1986_CR25","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1007\/s00256-012-1501-7","volume":"42","author":"R Guggenberger","year":"2013","unstructured":"Guggenberger R, Morsbach F, Alkadhi H, et al. C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers. Skeletal Radiol. 2013;42(3):419\u201329. doi: 10.1007\/s00256-012-1501-7 .","journal-title":"Skeletal Radiol"},{"issue":"8","key":"1986_CR26","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1097\/RLI.0b013e318289fa78","volume":"48","author":"R Guggenberger","year":"2013","unstructured":"Guggenberger R, Winklhofer S, Spiczak JV, Andreisek G, Alkadhi H. In vitro high-resolution flat-panel computed tomographic arthrography for artificial cartilage defect detection: comparison with multidetector computed tomography. Investig Radiol. 2013;48(8):614\u201321. doi: 10.1097\/RLI.0b013e318289fa78 .","journal-title":"Investig Radiol"}],"container-title":["Skeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-014-1986-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00256-014-1986-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-014-1986-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T15:49:57Z","timestamp":1558712997000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00256-014-1986-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8,28]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["1986"],"URL":"https:\/\/doi.org\/10.1007\/s00256-014-1986-3","relation":{},"ISSN":["0364-2348","1432-2161"],"issn-type":[{"value":"0364-2348","type":"print"},{"value":"1432-2161","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,8,28]]}}}