{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:00:37Z","timestamp":1740106837710,"version":"3.37.3"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2021,12,30]],"date-time":"2021-12-30T00:00:00Z","timestamp":1640822400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,12,30]],"date-time":"2021-12-30T00:00:00Z","timestamp":1640822400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"International Skeletal Society","award":["Early Career Grant"],"award-info":[{"award-number":["Early Career Grant"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Skeletal Radiol"],"published-print":{"date-parts":[[2022,7]]},"DOI":"10.1007\/s00256-021-03984-5","type":"journal-article","created":{"date-parts":[[2021,12,30]],"date-time":"2021-12-30T22:02:36Z","timestamp":1640901756000},"page":"1415-1423","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of AI-powered 3D automated ultrasound tomography with standard handheld ultrasound for the visualization of the hands\u2014clinical proof of concept"],"prefix":"10.1007","volume":"51","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1625-8826","authenticated-orcid":false,"given":"Jonas M.","family":"Getzmann","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malwina","family":"Kaniewska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Esin","family":"Rothenfluh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sophia","family":"Borowka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roman","family":"Guggenberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,30]]},"reference":[{"issue":"9","key":"3984_CR1","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.1002\/1529-0131(200109)44:9<2018::AID-ART350>3.0.CO;2-C","volume":"44","author":"M Szkudlarek","year":"2001","unstructured":"Szkudlarek M, Court-Payen M, Strandberg C, Klarlund M, Klausen T, Ostergaard M. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging. Arthritis Rheum. 2001;44(9):2018\u201323.","journal-title":"Arthritis Rheum"},{"issue":"1","key":"3984_CR2","doi-asserted-by":"publisher","first-page":"e000428","DOI":"10.1136\/rmdopen-2016-000428","volume":"3","author":"MA D\u2019Agostino","year":"2017","unstructured":"D\u2019Agostino MA, Terslev L, Aegerter P, et al. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce\u2013part 1: definition and development of a standardized, consensus-based scoring system. RMD Open. 2017;3(1):e000428.","journal-title":"RMD Open"},{"issue":"1","key":"3984_CR3","doi-asserted-by":"publisher","first-page":"e000427","DOI":"10.1136\/rmdopen-2016-000427","volume":"3","author":"L Terslev","year":"2017","unstructured":"Terslev L, Naredo E, Aegerter P, et al. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-part 2: reliability and application to multiple joints of a standardized consensus-based scoring system. RMD Open. 2017;3(1):e000427.","journal-title":"RMD Open"},{"issue":"8","key":"3984_CR4","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1093\/rheumatology\/kex153","volume":"56","author":"R Husic","year":"2017","unstructured":"Husic R, Lackner A, Stradner MH, Hermann J, Dejaco C. Joint positions matter for ultrasound examination of RA patients\u2013increased power Doppler signal in neutral versus flat position of hands. Rheumatology (Oxford). 2017;56(8):1312\u20139.","journal-title":"Rheumatology (Oxford)"},{"issue":"8","key":"3984_CR5","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1007\/s11926-020-00911-w","volume":"22","author":"A Di Matteo","year":"2020","unstructured":"Di Matteo A, Kulveer M, Azukizawa M, Wakefield RJ. The role of musculoskeletal ultrasound in the rheumatoid arthritis continuum. Curr Rheumatol Rep. 2020;22(8):41.","journal-title":"Curr Rheumatol Rep"},{"issue":"1","key":"3984_CR6","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s42358-018-0023-y","volume":"58","author":"AD Do Prado","year":"2018","unstructured":"Do Prado AD, Staub HL, Bisi MC, et al. Ultrasound and its clinical use in rheumatoid arthritis: where do we stand? Adv Rheumatol. 2018;58(1):19.","journal-title":"Adv Rheumatol"},{"key":"3984_CR7","first-page":"234","volume-title":"Medical image computing and computer-assisted intervention\u2013MICCAI 2015. MICCAI 2015. Lecture Notes in Computer Science","author":"O Ronneberger","year":"2015","unstructured":"Ronneberger O, Fischer P, Brox T. U-Net: Convolutional Networks for Biomedical Image Segmentation. In: Navab N, Hornegger J, Wells W, Frangi A, editors. Medical image computing and computer-assisted intervention\u2013MICCAI 2015. MICCAI 2015. Lecture Notes in Computer Science, vol. 9351. Cham: Springer; 2015. p. 234\u201341."},{"issue":"3","key":"3984_CR8","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s00296-015-3409-8","volume":"36","author":"I Janta","year":"2016","unstructured":"Janta I, Valor L, De la Torre I, et al. Ultrasound-detected activity in rheumatoid arthritis on methotrexate therapy: which joints and tendons should be assessed to predict unstable remission? Rheumatol Int. 2016;36(3):387\u201396.","journal-title":"Rheumatol Int"},{"key":"3984_CR9","first-page":"5","volume":"140","author":"R Likert","year":"1932","unstructured":"Likert R. A technique for the measurements of attitudes. Archives of Psychology. 1932;140:5\u201355.","journal-title":"Archives of Psychology"},{"issue":"1","key":"3984_CR10","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159\u201374.","journal-title":"Biometrics"},{"issue":"9","key":"3984_CR11","doi-asserted-by":"publisher","first-page":"3767","DOI":"10.1007\/s00330-017-4749-4","volume":"27","author":"R Girometti","year":"2017","unstructured":"Girometti R, Zanotel M, Londero V, Bazzocchi M, Zuiani C. Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging. Eur Radiol. 2017;27(9):3767\u201375.","journal-title":"Eur Radiol"},{"issue":"10","key":"3984_CR12","doi-asserted-by":"publisher","first-page":"2860","DOI":"10.1016\/j.ultrasmedbio.2021.06.007","volume":"47","author":"J Su","year":"2021","unstructured":"Su J, Han X, Yang F, Song Y, Lei H, Wang X, Fan X, Li Y. Application of automated hand ultrasound scanning and a simplified three-joint scoring system for assessment of rheumatoid arthritis activity. Ultrasound Med Biol. 2021;47(10):2860\u20138.","journal-title":"Ultrasound Med Biol"},{"issue":"9","key":"3984_CR13","doi-asserted-by":"publisher","first-page":"1194","DOI":"10.1002\/art.24646","volume":"61","author":"M Backhaus","year":"2009","unstructured":"Backhaus M, Ohrndorf S, Kellner H, et al. Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: a pilot project. Arthritis Rheum. 2009;61(9):1194\u2013201.","journal-title":"Arthritis Rheum"},{"issue":"7","key":"3984_CR14","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1136\/ard.2009.126995","volume":"69","author":"HB Hammer","year":"2010","unstructured":"Hammer HB, Sveinsson M, Kongtorp AK, Kvien TK. A 78-joints ultrasonographic assessment is associated with clinical assessments and is highly responsive to improvement in a longitudinal study of patients with rheumatoid arthritis starting adalimumab treatment. Ann Rheum Dis. 2010;69(7):1349\u201351.","journal-title":"Ann Rheum Dis"},{"issue":"4","key":"3984_CR15","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1002\/art.23529","volume":"59","author":"E Naredo","year":"2008","unstructured":"Naredo E, Rodr\u00edguez M, Campos C, et al. Validity, reproducibility, and responsiveness of a twelve-joint simplified power Doppler ultrasonographic assessment of joint inflammation in rheumatoid arthritis. Arthritis Rheum. 2008;59(4):515\u201322.","journal-title":"Arthritis Rheum"},{"issue":"8","key":"3984_CR16","doi-asserted-by":"publisher","first-page":"1841","DOI":"10.1016\/j.ultrasmedbio.2020.04.015","volume":"46","author":"S Elangovan","year":"2020","unstructured":"Elangovan S, Tan YK. The role of musculoskeletal ultrasound imaging in rheumatoid arthritis. Ultrasound Med Biol. 2020;46(8):1841\u201353.","journal-title":"Ultrasound Med Biol"}],"container-title":["Skeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-021-03984-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00256-021-03984-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-021-03984-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T07:06:00Z","timestamp":1652339160000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00256-021-03984-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,30]]},"references-count":16,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["3984"],"URL":"https:\/\/doi.org\/10.1007\/s00256-021-03984-5","relation":{},"ISSN":["0364-2348","1432-2161"],"issn-type":[{"type":"print","value":"0364-2348"},{"type":"electronic","value":"1432-2161"}],"subject":[],"published":{"date-parts":[[2021,12,30]]},"assertion":[{"value":"11 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"S.B. is a co-founder of Aison Technologies AG, provided the 3D ultrasound tomography prototype, participated in data acquisition, and performed image post-processing. She was not involved in data analysis or interpretation. R.G. is a scientific advisor of Aison Technologies AG. The other authors declare that they have no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}