{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T20:06:01Z","timestamp":1784577961719,"version":"3.55.0"},"reference-count":64,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,5,10]],"date-time":"2022-05-10T00:00:00Z","timestamp":1652140800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,5,10]],"date-time":"2022-05-10T00:00:00Z","timestamp":1652140800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Skeletal Radiol"],"published-print":{"date-parts":[[2023,3]]},"DOI":"10.1007\/s00256-022-04069-7","type":"journal-article","created":{"date-parts":[[2022,5,10]],"date-time":"2022-05-10T08:09:35Z","timestamp":1652170175000},"page":"393-404","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Carbon-fiber-reinforced polyetheretherketone orthopedic implants in musculoskeletal and spinal tumors: imaging and clinical features"],"prefix":"10.1007","volume":"52","author":[{"given":"Jeremiah R.","family":"Long","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maziyar A.","family":"Kalani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krista A.","family":"Goulding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan B.","family":"Ashman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan A.","family":"Flug","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,10]]},"reference":[{"issue":"9","key":"4069_CR1","doi-asserted-by":"publisher","first-page":"1735","DOI":"10.1007\/s00264-017-3562-7","volume":"41","author":"DJ Hak","year":"2017","unstructured":"Hak DJ, Fader R, Baldini T, Chadayammuri VBS. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates. Int Orthop. 2017;41(9):1735\u20139.","journal-title":"Int Orthop"},{"key":"4069_CR2","doi-asserted-by":"crossref","unstructured":"Hillock R, Howard S. Utility of carbon fiber implants in orthopedic surgery: literature review. Reconstr Rev. 2014;4(1).","DOI":"10.15438\/rr.v4i1.55"},{"issue":"7","key":"4069_CR3","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1016\/j.jhsa.2012.04.027","volume":"37","author":"SS Van Nortwick","year":"2012","unstructured":"Van Nortwick SS, Yao J, Ladd AL. Titanium integration with bone, welding, and screw head destruction complicating hardware removal of the distal radius: report of 2 cases. J Hand Surg Am. 2012;37(7):1388\u201392.","journal-title":"J Hand Surg Am"},{"key":"4069_CR4","first-page":"1538158","volume":"2019","author":"GF Vles","year":"2019","unstructured":"Vles GF, Brodermann MH, Roussot MA, Youngman J. Carbon-fiber-reinforced PEEK intramedullary nails defining the niche. Case Rep Orthop. 2019;2019:1538158.","journal-title":"Case Rep Orthop"},{"issue":"3","key":"4069_CR5","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1097\/CORR.0000000000002127","volume":"480","author":"BK Potter","year":"2022","unstructured":"Potter BK. From bench to bedside: radiolucent implants-better visualization or camouflaged gimmick? Clin Orthop Relat Res. 2022;480(3):461\u20133.","journal-title":"Clin Orthop Relat Res"},{"key":"4069_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2021.113640","volume":"262","author":"R Hsissou","year":"2021","unstructured":"Hsissou R, Seghiri R, Benzekri Z, et al. Polymer composite materials: a comprehensive review. Compos Struct. 2021;262: 113640.","journal-title":"Compos Struct"},{"key":"4069_CR7","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.jmbbm.2012.09.013","volume":"17","author":"EL Steinberg","year":"2013","unstructured":"Steinberg EL, Rath E, Shlaifer A, Ofir C, et al. Carbon fiber reinforced PEEK Optima\u2013a composite material biomechanical properties and wear\/debris characteristics of CF-PEEK composites for orthopedic trauma implants. J Mech Behav Biomed Mater. 2013;17:221\u20138.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"9","key":"4069_CR8","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1007\/s00256-015-2158-9","volume":"44","author":"MN Zimel","year":"2015","unstructured":"Zimel MN, Hwang S, Riedel ER, Healey JH. Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging. Skelet Radiol. 2015;44(9):1317\u201325.","journal-title":"Skelet Radiol"},{"issue":"12","key":"4069_CR9","doi-asserted-by":"publisher","first-page":"e720","DOI":"10.1016\/S1470-2045(17)30612-5","volume":"18","author":"DE Spratt","year":"2017","unstructured":"Spratt DE, Beeler WH, de Moraes FY, et al. An integrated multidisciplinary algorithm for the management of spinal metastases: an International Spine Oncology Consortium report. Lancet Oncol. 2017;18(12):e720\u201330.","journal-title":"Lancet Oncol"},{"issue":"1 Suppl","key":"4069_CR10","doi-asserted-by":"publisher","first-page":"108S","DOI":"10.1177\/2192568219828727","volume":"9","author":"R Charest-Morin","year":"2019","unstructured":"Charest-Morin R, Fisher CG, Sahgal A, et al. Primary bone tumor of the spine-an evolving field: what a general spine surgeon should know. Glob Spine J. 2019;9(1 Suppl):108S-116S.","journal-title":"Glob Spine J"},{"issue":"5","key":"4069_CR11","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1120\/jacmp.v16i5.5566","volume":"16","author":"Y Jia","year":"2015","unstructured":"Jia Y, Zhao L, Cheng C, et al. Dose perturbation effect of metallic spinal implants in proton beam therapy. J Appl Clin Med Phys. 2015;16(5):333\u201343.","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"4069_CR12","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1007\/s00586-017-5258-5","volume":"27","author":"S Boriani","year":"2018","unstructured":"Boriani S, Tedesco G, Ming L, et al. Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report. Eur Spine J. 2018;27(4):874\u201381.","journal-title":"Eur Spine J"},{"issue":"3","key":"4069_CR13","doi-asserted-by":"publisher","first-page":"323","DOI":"10.21037\/jss.2017.06.20","volume":"3","author":"G Tedesco","year":"2017","unstructured":"Tedesco G, Gasbarrini A, Bandiera, et al. Composite PEEK\/Carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. J Spine Surg. 2017;3(3):323\u20139.","journal-title":"J Spine Surg"},{"issue":"12","key":"4069_CR14","doi-asserted-by":"publisher","first-page":"3229","DOI":"10.1007\/s00586-020-06534-0","volume":"29","author":"S Boriani","year":"2020","unstructured":"Boriani S, Pipola V, Cecchinato R, et al. Composite PEEK\/carbon fiber rods in the treatment for bone tumors of the cervical spine: a case series. Eur Spine J. 2020;29(12):3229\u201336.","journal-title":"Eur Spine J"},{"key":"4069_CR15","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.jocn.2020.03.013","volume":"75","author":"F Cofano","year":"2020","unstructured":"Cofano F, Di Perna G, Monticelli M, et al. Carbon fiber reinforced vs titanium implants for fixation in spinal metastases: a comparative clinical study about safety and effectiveness of the new \u201ccarbon-strategy.\u201d J Clin Neurosci. 2020;75:106\u201311.","journal-title":"J Clin Neurosci"},{"issue":"17","key":"4069_CR16","doi-asserted-by":"publisher","first-page":"2732","DOI":"10.3390\/ma12172732","volume":"12","author":"D Adler","year":"2019","unstructured":"Adler D, Akbar M, Spicher A, et al. Biomechanical study of a novel, expandable, non-metallic and radiolucent CF\/PEEK vertebral body replacement (VBR). Materials (Basel). 2019;12(17):2732.","journal-title":"Materials (Basel)"},{"issue":"3","key":"4069_CR17","doi-asserted-by":"publisher","first-page":"29","DOI":"10.3390\/jfb10030029","volume":"10","author":"H Milavec","year":"2019","unstructured":"Milavec H, Kellner C, Ravikumar N, et al. First clinical experience with a carbon fibre reinforced PEEK composite plating system for anterior cervical discectomy and fusion. J Funct Biomater. 2019;10(3):29.","journal-title":"J Funct Biomater"},{"issue":"6","key":"4069_CR18","doi-asserted-by":"publisher","first-page":"766","DOI":"10.3171\/2010.5.SPINE09948","volume":"13","author":"HJ Bruner","year":"2010","unstructured":"Bruner HJ, Guan Y, Yoganandan N, et al. Biomechanics of polyaryletherketone rod composites and titanium rods for posterior lumbosacral instrumentation. Presented at the 2010 Joint Spine Section Meeting. Laboratory investigation. J Neurosurg Spine. 2010;13(6):766\u201372.","journal-title":"J Neurosurg Spine"},{"key":"4069_CR19","first-page":"4796136","volume":"2020","author":"O Uri","year":"2020","unstructured":"Uri O, Folman Y, Laufer G, Behrbalk E. A novel spine fixation system made entirely of carbon-fiber-reinforced PEEK composite: an in vitro mechanical evaluation. Adv Orthop. 2020;2020:4796136.","journal-title":"Adv Orthop"},{"issue":"8","key":"4069_CR20","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1007\/s00586-018-5538-8","volume":"27","author":"RA Lindtner","year":"2018","unstructured":"Lindtner RA, Schmid R, Nydegger T, et al. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading. Eur Spine J. 2018;27(8):1775\u201384.","journal-title":"Eur Spine J"},{"key":"4069_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2020.105153","volume":"80","author":"S Oikonomidis","year":"2020","unstructured":"Oikonomidis S, Greven J, Bredow J, et al. Biomechanical effects of posterior pedicle screw-based instrumentation using titanium versus carbon fiber reinforced PEEK in an osteoporotic spine human cadaver model. Clin Biomech (Bristol, Avon). 2020;80: 105153.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"5","key":"4069_CR22","doi-asserted-by":"publisher","first-page":"E13","DOI":"10.3171\/2021.2.FOCUS20995","volume":"50","author":"MT Neal","year":"2021","unstructured":"Neal MT, Richards AE, Curley KL, et al. Carbon fiber-reinforced PEEK instrumentation in the spinal oncology population: a retrospective series demonstrating technique, feasibility, and clinical outcomes. Neurosurg Focus. 2021;50(5):E13.","journal-title":"Neurosurg Focus"},{"key":"4069_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbo.2020.100320","volume":"25","author":"G Di Perna","year":"2020","unstructured":"Di Perna G, Cofano F, Mantovani C, Badellino S, et al. Separation surgery for metastatic epidural spinal cord compression: a qualitative review. J Bone Oncol. 2020;25: 100320.","journal-title":"J Bone Oncol"},{"issue":"3","key":"4069_CR24","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/BRS.0000000000004177","volume":"47","author":"FH Shen","year":"2022","unstructured":"Shen FH, Gasbarrini A, Lui DF, Reynolds J, et al. Integrated custom composite polyetheretherketone\/carbon fiber (PEEK\/CF) vertebral body replacement (VBR) in the treatment of bone tumors of the spine: a preliminary report from a multicenter study. Spine (Phila Pa 1976). 2022;47(3):252\u201360.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"4069_CR25","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1186\/s12957-018-1545-9","volume":"16","author":"CJ Laux","year":"2018","unstructured":"Laux CJ, Hodel SM, Farshad M, Muller DA. Carbon fibre\/polyether ether ketone (CF\/PEEK) implants in orthopaedic oncology. World J Surg Oncol. 2018;16(1):241.","journal-title":"World J Surg Oncol"},{"issue":"Suppl 3","key":"4069_CR26","first-page":"iii113","volume":"25","author":"ESMO\/European Sarcoma Network Working Group","year":"2014","unstructured":"ESMO\/European Sarcoma Network Working Group. Bone sarcomas: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up. Ann Oncol. 2014;25(Suppl 3):iii113-2.","journal-title":"Ann Oncol"},{"issue":"Suppl 3","key":"4069_CR27","first-page":"iii102","volume":"25","author":"ESMO\/European Sarcoma Network Working Group","year":"2014","unstructured":"ESMO\/European Sarcoma Network Working Group. Soft tissue and visceral sarcomas: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up. Ann Oncol. 2014;25(Suppl 3):iii102-12.","journal-title":"Ann Oncol."},{"key":"4069_CR28","doi-asserted-by":"publisher","first-page":"8289509","DOI":"10.1155\/2016\/8289509","volume":"2016","author":"DD Greenberg","year":"2016","unstructured":"Greenberg DD, Crawford B. Surveillance strategies for sarcoma: results of a survey of Members of the Musculoskeletal Tumor Society. Sarcoma. 2016;2016:8289509.","journal-title":"Sarcoma"},{"issue":"2","key":"4069_CR29","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1302\/0301-620X.100B2.BJJ-2017-0789.R1","volume":"100-B","author":"A Puri","year":"2018","unstructured":"Puri A, Ranganathan P, Gulia A, Crasto S, et al. Does a less intensive surveillance protocol affect the survival of patients after treatment of a sarcoma of the limb? Updated results of the randomized TOSS study. Bone Joint J. 2018;100-B(2):262\u20138.","journal-title":"Bone Joint J"},{"issue":"1","key":"4069_CR30","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/S0959-8049(00)00362-2","volume":"37","author":"S Weeden","year":"2001","unstructured":"Weeden S, Grimer RJ, Cannon SR, Taminiau AH, et al. The effect of local recurrence on survival in resected osteosarcoma. Eur J Cancer. 2001;37(1):39\u201346.","journal-title":"Eur J Cancer"},{"issue":"6","key":"4069_CR31","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1302\/0301-620X.98B6.37417","volume":"98-B","author":"RJ Grimer","year":"2016","unstructured":"Grimer RJ, Aydin BK, Wafa H, Carter SR, et al. Very long-term outcomes after endoprosthetic replacement for malignant tumours of bone. Bone Joint J. 2016;98-B(6):857\u201364.","journal-title":"Bone Joint J"},{"issue":"10","key":"4069_CR32","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0204927","volume":"13","author":"MW Joo","year":"2018","unstructured":"Joo MW, Kang YK, Ogura K, Iwata S, et al. Post-radiation sarcoma: a study by the Eastern Asian Musculoskeletal Oncology Group. PLoS ONE. 2018;13(10): e0204927.","journal-title":"PLoS ONE"},{"issue":"5","key":"4069_CR33","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1097\/00000421-198910000-00010","volume":"12","author":"BE Amendola","year":"1989","unstructured":"Amendola BE, Amendola MA, McClatchey KD, Miller CH Jr. Radiation-associated sarcoma: a review of 23 patients with postradiation sarcoma over a 50-year period. Am J Clin Oncol. 1989;12(5):411\u20135.","journal-title":"Am J Clin Oncol"},{"issue":"5","key":"4069_CR34","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1016\/j.breast.2010.04.006","volume":"19","author":"E Erel","year":"2010","unstructured":"Erel E, Vlachou E, Athanasiadou M, Hassan S, et al. Management of radiation-induced sarcomas in a tertiary referral centre: a review of 25 cases. Breast. 2010;19(5):424\u20137.","journal-title":"Breast"},{"issue":"12","key":"4069_CR35","doi-asserted-by":"publisher","first-page":"2064","DOI":"10.1200\/JCO.2009.25.1728","volume":"28","author":"RA Gladdy","year":"2010","unstructured":"Gladdy RA, Quin L, Moraco N, Edgar MA, et al. Do radiation-associated soft tissue sarcomas have the same prognosis as sporadic soft tissue sarcomas? J Clin Oncol. 2010;28(12):2064\u20139.","journal-title":"J Clin Oncol"},{"issue":"1","key":"4069_CR36","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/S0003-4975(96)00927-7","volume":"63","author":"AR Chapelier","year":"1997","unstructured":"Chapelier AR, Bacha EA, de Montpreville VT, Dulmet EM, et al. Radical resection of radiation-induced sarcoma of the chest wall: report of 15 cases. Ann Thorac Surg. 1997;63(1):214\u20139.","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"4069_CR37","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1016\/j.ejso.2008.11.008","volume":"35","author":"SJ Neuhaus","year":"2009","unstructured":"Neuhaus SJ, Pinnock N, Giblin V, Fisher C, et al. Treatment and outcome of radiation-induced soft-tissue sarcomas at a specialist institution. Eur J Surg Oncol. 2009;35(6):654\u20139.","journal-title":"Eur J Surg Oncol"},{"issue":"3","key":"4069_CR38","doi-asserted-by":"publisher","first-page":"e20.00041","DOI":"10.2106\/JBJS.CC.20.00041","volume":"10","author":"WA Goudriaan","year":"2020","unstructured":"Goudriaan WA, Tordoir RL, Broekhuis D, van der Wal RJP. Early failure of a carbon-fiber-reinforced polyetheretherketone distal femur plate: a case report. JBJS Case Connect. 2020;10(3):e20.00041.","journal-title":"JBJS Case Connect"},{"key":"4069_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.tcr.2021.100493","volume":"34","author":"MB Mellon","year":"2021","unstructured":"Mellon MB. Late recognition of an early catastrophic failure of a carbon fiber reinforced distal femoral plate: a case report. Trauma Case Rep. 2021;34: 100493.","journal-title":"Trauma Case Rep"},{"issue":"4","key":"4069_CR40","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.CC.18.00096","volume":"8","author":"AE Loeb","year":"2018","unstructured":"Loeb AE, Mitchell SL, Osgood GM, Shafiq B. Catastrophic failure of a carbon-fiber-reinforced polyetheretherketone tibial intramedullary nail: a case report. JBJS Case Connect. 2018;8(4): e83.","journal-title":"JBJS Case Connect"},{"issue":"4","key":"4069_CR41","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1016\/j.injury.2010.10.012","volume":"42","author":"PN Collis","year":"2011","unstructured":"Collis PN, Clegg TE, Seligson D. The invisible nail: a technique report of treatment of a pathological humerus fracture with a radiolucent intramedullary nail. Injury. 2011;42(4):424\u20136.","journal-title":"Injury"},{"issue":"4","key":"4069_CR42","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","volume":"15","author":"L Tarallo","year":"2014","unstructured":"Tarallo L, Mugnai R, Adani R, Zambianchi F, Catani F. A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases. J Orthop Traumatol. 2014;15(4):277\u201383.","journal-title":"J Orthop Traumatol"},{"issue":"Suppl 3","key":"4069_CR43","doi-asserted-by":"publisher","first-page":"S34","DOI":"10.1016\/S0020-1383(17)30655-1","volume":"48","author":"B Di Maggio","year":"2017","unstructured":"Di Maggio B, Sessa P, Mantelli P, Maniscalco P, et al. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up. Injury. 2017;48(Suppl 3):S34\u20138.","journal-title":"Injury"},{"issue":"Suppl 3","key":"4069_CR44","doi-asserted-by":"publisher","first-page":"S24","DOI":"10.1016\/S0020-1383(17)30653-8","volume":"48","author":"D Perugia","year":"2017","unstructured":"Perugia D, Guzzini M, Mazza D, Iorio C, et al. Comparison between carbon-PEEK volar locking plates and titanium volar locking plates in the treatment of distal radius fractures. Injury. 2017;48(Suppl 3):S24\u20139.","journal-title":"Injury"},{"issue":"3","key":"4069_CR45","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1177\/1938640017718343","volume":"11","author":"ZW Pinter","year":"2018","unstructured":"Pinter ZW, Smith KS, Hudson PW, Jones CW, et al. A retrospective case series of carbon fiber plate fixation of ankle fractures. Foot Ankle Spec. 2018;11(3):223\u20139.","journal-title":"Foot Ankle Spec"},{"key":"4069_CR46","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.medengphy.2019.03.006","volume":"67","author":"EA Gallagher","year":"2019","unstructured":"Gallagher EA, Lamoriniere S, McGarry P. Finite element investigation into the use of carbon fibre reinforced PEEK laminated composites for distal radius fracture fixation implants. Med Eng Phys. 2019;67:22\u201332.","journal-title":"Med Eng Phys"},{"issue":"3","key":"4069_CR47","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1016\/j.injury.2020.01.007","volume":"51","author":"K Takashima","year":"2020","unstructured":"Takashima K, Nakahara I, Uemura K, Hamada H, et al. Clinical outcomes of proximal femoral fractures treated with a novel carbon fiber-reinforced polyetheretherketone intramedullary nail. Injury. 2020;51(3):678\u201382.","journal-title":"Injury"},{"issue":"2","key":"4069_CR48","doi-asserted-by":"publisher","first-page":"113","DOI":"10.5435\/00124635-200802000-00009","volume":"16","author":"DJ Hak","year":"2008","unstructured":"Hak DJ, McElvany M. Removal of broken hardware. J Am Acad Orthop Surg. 2008;16(2):113\u201320.","journal-title":"J Am Acad Orthop Surg"},{"key":"4069_CR49","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.wneu.2021.05.100","volume":"152","author":"A Takayanagi","year":"2021","unstructured":"Takayanagi A, Siddiqi I, Ghanchi H, Lischalk J, et al. Radiolucent carbon fiber-reinforced implants for treatment of spinal tumors-clinical, radiographic, and dosimetric considerations. World Neurosurg. 2021;152:61\u201370.","journal-title":"World Neurosurg"},{"key":"4069_CR50","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.wneu.2017.04.091","volume":"105","author":"F Ringel","year":"2017","unstructured":"Ringel F, Ryang Y, Krischke JS, Muller BS, et al. Radiolucent carbon fiber-reinforced pedicle screws for treatment of spinal tumors: advantages for radiation planning and follow-up imaging. World Neurosurg. 2017;105:294\u2013301.","journal-title":"World Neurosurg"},{"issue":"4","key":"4069_CR51","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s10143-020-01384-2","volume":"44","author":"T Kratzig","year":"2021","unstructured":"Kratzig T, Mende KC, Mohme M, Kniep H, et al. Carbon fiber-reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg Rev. 2021;44(4):2163\u201370.","journal-title":"Neurosurg Rev"},{"issue":"Suppl 6","key":"4069_CR52","doi-asserted-by":"publisher","first-page":"S36","DOI":"10.1016\/j.injury.2014.10.020","volume":"45","author":"M Caforio","year":"2014","unstructured":"Caforio M, Perugia D, Colombo M, Calori GM, et al. Preliminary experience with Piccolo Composite\u2122, a radiolucent distal fibula plate, in ankle fractures. Injury. 2014;45(Suppl 6):S36\u20138.","journal-title":"Injury"},{"issue":"Suppl 5","key":"4069_CR53","doi-asserted-by":"publisher","first-page":"S8","DOI":"10.1016\/S0020-1383(17)30731-3","volume":"48","author":"N Kojic","year":"2017","unstructured":"Kojic N, Rangger C, Ozgun C, Lojpur, et al. Carbon-fibre-reinforced PEEK radiolucent intramedullary nail for humeral shaft fracture fixation: technical features and a pilot clinical study. Injury. 2017;48(Suppl 5):S8\u201311.","journal-title":"Injury"},{"issue":"11","key":"4069_CR54","doi-asserted-by":"publisher","first-page":"1437","DOI":"10.1097\/00007632-200006010-00017","volume":"25","author":"JW Brantigan","year":"2000","unstructured":"Brantigan JW, Steffee AD, Lewis ML, Quinn LM, Persenaire JM. Lumbar interbody fusion using the Brantigan I\/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: two-year results from a Food and Drug Administration investigational device exemption clinical trial. Spine (Phila Pa 1976). 2000;25(11):1437\u201346.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"4069_CR55","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1007\/s00256-020-03622-6","volume":"50","author":"FT Delaney","year":"2021","unstructured":"Delaney FT, Denton H, Dodds M, Kavanaugh EC. Multimodal imaging of composite carbon fiber-based implants for orthopedic spinal fixation. Skelet Radiol. 2021;50(5):1039\u201345.","journal-title":"Skelet Radiol"},{"issue":"1","key":"4069_CR56","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s12880-021-00554-y","volume":"21","author":"FA Huber","year":"2021","unstructured":"Huber FA, Sprengel K, Muller L, Graf LC, et al. Comparison of different CT metal artifact reduction strategies for standard titanium and carbon-fiber reinforced polymer implants in sheep cadavers. BMC Med Imaging. 2021;21(1):29.","journal-title":"BMC Med Imaging"},{"issue":"4","key":"4069_CR57","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.jor.2016.07.001","volume":"13","author":"C Zoccali","year":"2016","unstructured":"Zoccali C, Soriana A, Rossi B, Salducca N, et al. The Carbofix\u2122 \u201cPiccolo proximal femur nail\u201d: a new perspective for treating proximal femur lesion. A technique report. J Orthop. 2016;13(4):343\u20136.","journal-title":"J Orthop"},{"issue":"3","key":"4069_CR58","doi-asserted-by":"publisher","first-page":"547","DOI":"10.2214\/AJR.11.7364","volume":"197","author":"BA Hargreaves","year":"2011","unstructured":"Hargreaves BA, Worters PW, Pauly KB, Pauly JM, et al. Metal-induced artifacts in MRI. AJR Am J Roentgenol. 2011;197(3):547\u201355.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"4069_CR59","doi-asserted-by":"publisher","first-page":"16094","DOI":"10.1038\/s41598-020-73386-5","volume":"10","author":"C Fleege","year":"2020","unstructured":"Fleege C, Makowski M, Rauschmann M, Fraunhoffer KL, et al. Carbon fiber-reinforced pedicle screws reduce artifacts in magnetic resonance imaging of patients with lumbar spondylodesis. Sci Rep. 2020;10(1):16094.","journal-title":"Sci Rep"},{"issue":"2","key":"4069_CR60","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1016\/j.ijrobp.2006.08.052","volume":"67","author":"HP Rutz","year":"2007","unstructured":"Rutz HP, Weber DC, Sugahara S, Timmermann B, et al. Extracranial chordoma: outcome in patients treated with function-preserving surgery followed by spot-scanning proton beam irradiation. Int J Radiat Oncol Biol Phys. 2007;67(2):512\u201320.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"4","key":"4069_CR61","doi-asserted-by":"publisher","first-page":"3821","DOI":"10.1120\/jacmp.v13i4.3821","volume":"13","author":"N Xin-ye","year":"2012","unstructured":"Xin-ye N, Xiao-bin T, Chang-ran G, Da C. The prospect of carbon fiber implants in radiotherapy. J Appl Clin Med Phys. 2012;13(4):3821.","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"4069_CR62","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1002\/acm2.12046","volume":"18","author":"A Nevelsky","year":"2017","unstructured":"Nevelsky A, Borzov E, Daniel S, Bar-Deroma R. Perturbation effects of the carbon fiber-PEEK screws on radiotherapy dose distribution. J Appl Clin Med Phys. 2017;18(2):62\u20138.","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"4069_CR63","volume":"91","author":"A Soriani","year":"2020","unstructured":"Soriani A, Strigari L, Petrongari MG, Anelli V, et al. The advantages of carbon fiber based orthopedic devices in patients who have to undergo radiotherapy. Acta Biomed. 2020;91(3): e2020057.","journal-title":"Acta Biomed"},{"issue":"7","key":"4069_CR64","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.3390\/ma13071754","volume":"13","author":"CJ Laux","year":"2020","unstructured":"Laux CJ, Villefort C, Ehrbar S, Wilke L, et al. Carbon fiber\/polyether ether ketone (CF\/PEEK) implants allow for more effective radiation in long bones. Materials (Basel). 2020;13(7):1754.","journal-title":"Materials (Basel)"}],"container-title":["Skeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-022-04069-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00256-022-04069-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-022-04069-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,21]],"date-time":"2023-01-21T03:25:41Z","timestamp":1674271541000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00256-022-04069-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,10]]},"references-count":64,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["4069"],"URL":"https:\/\/doi.org\/10.1007\/s00256-022-04069-7","relation":{},"ISSN":["0364-2348","1432-2161"],"issn-type":[{"value":"0364-2348","type":"print"},{"value":"1432-2161","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,10]]},"assertion":[{"value":"2 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 May 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"MAK is a consultant for Carbofix, NuVasive, and Medtronic. The remaining authors declare they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}