{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T05:56:07Z","timestamp":1777010167207,"version":"3.51.4"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,5,30]],"date-time":"2022-05-30T00:00:00Z","timestamp":1653868800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,5,30]],"date-time":"2022-05-30T00:00:00Z","timestamp":1653868800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100006502","name":"Defense Sciences Office, DARPA","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006502","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Skeletal Radiol"],"published-print":{"date-parts":[[2022,11]]},"DOI":"10.1007\/s00256-022-04079-5","type":"journal-article","created":{"date-parts":[[2022,5,30]],"date-time":"2022-05-30T04:02:44Z","timestamp":1653883364000},"page":"2185-2193","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Prospective pre-operative 3-T MR neurography peripheral nerve mapping of upper extremity amputations implanted with FAST-LIFE electrode interfaces of robotic hands: technical report"],"prefix":"10.1007","volume":"51","author":[{"given":"Bayan","family":"Mogharrabi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raghu","family":"Ratakonda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward","family":"Keefer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Avneesh","family":"Chhabra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,30]]},"reference":[{"key":"4079_CR1","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1016\/B978-0-323-54947-9.00119-X","volume-title":"Essentials of physical medicine and rehabilitation","author":"DW Braza","year":"2020","unstructured":"Braza DW, Martin JNY. Chapter 119 - Upper limb amputations. In: Frontera WR, Silver JK, Rizzo TD, editors. Essentials of physical medicine and rehabilitation. 4th ed. Philadelphia: Elsevier; 2020. p. 651\u20137.","edition":"4"},{"issue":"3","key":"4079_CR2","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.apmr.2007.11.005","volume":"89","author":"K Ziegler-Graham","year":"2008","unstructured":"Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R. Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil. 2008;89(3):422\u20139.","journal-title":"Arch Phys Med Rehabil"},{"issue":"7","key":"4079_CR3","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1682\/JRRD.2007.09.0151","volume":"45","author":"KA Raichle","year":"2008","unstructured":"Raichle KA, Hanley MA, Molton I, Kadel NJ, Campbell K, Phelps E, et al. Prosthesis use in persons with lower- and upper-limb amputation. J Rehabil Res Dev. 2008;45(7):961\u201372.","journal-title":"J Rehabil Res Dev"},{"key":"4079_CR4","unstructured":"National Academies of Sciences E, and Medicine; Health and Medicine Division; Board on Health Care Services; Committee on the use of selected assistive products and technologies in eliminating or reducing the effects of impairments. In: Flaubert JL, Spicer CM, Jette AM, eds. The promise of assistive technology to enhance activity and work participation. Washington (DC): National Academies Press (US). Copyright 2017 by the National Academy of Sciences. All rights reserved.; 2017."},{"issue":"4","key":"4079_CR5","first-page":"84","volume":"10","author":"PJ Kyberd","year":"1998","unstructured":"Kyberd PJ, Beard DJ, Davey JJ, Morrison JD. A survey of upper-limb prosthesis users in Oxfordshire. JPO: Journal of Prosthetics and Orthotics. 1998;10(4):84\u201391.","journal-title":"JPO: Journal of Prosthetics and Orthotics"},{"key":"4079_CR6","doi-asserted-by":"crossref","unstructured":"Cordella F, Ciancio AL, Sacchetti R, Davalli A, Cutti AG, Guglielmelli E, et al. Literature review on needs of upper limb prosthesis users. Frontiers in Neuroscience. 2016; 10.","DOI":"10.3389\/fnins.2016.00209"},{"key":"4079_CR7","doi-asserted-by":"crossref","unstructured":"Nguyen AT, Xu J, Jiang M, Luu DK, Wu T, Tam WK, et al. A bioelectric neural interface towards intuitive prosthetic control for amputees. J Neural Eng. 2020.","DOI":"10.1101\/2020.09.17.301663"},{"issue":"3","key":"4079_CR8","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1016\/j.hcl.2021.04.004","volume":"37","author":"J Cheng","year":"2021","unstructured":"Cheng J, Yang Z, Overstreet CK, Keefer E. Fascicle-specific targeting of longitudinal intrafascicular electrodes for motor and sensory restoration in upper-limb amputees. Hand Clin. 2021;37(3):401\u201314.","journal-title":"Hand Clin"},{"issue":"2","key":"4079_CR9","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1007\/s00330-017-4976-8","volume":"28","author":"A Chhabra","year":"2018","unstructured":"Chhabra A, Madhuranthakam AJ, Andreisek G. Magnetic resonance neurography: current perspectives and literature review. Eur Radiol. 2018;28(2):698\u2013707.","journal-title":"Eur Radiol"},{"issue":"5","key":"4079_CR10","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1007\/s00330-015-3958-y","volume":"26","author":"A Chhabra","year":"2016","unstructured":"Chhabra A, Belzberg AJ, Rosson GD, Thawait GK, Chalian M, Farahani SJ, et al. Impact of high resolution 3 tesla MR neurography (MRN) on diagnostic thinking and therapeutic patient management. Eur Radiol. 2016;26(5):1235\u201344.","journal-title":"Eur Radiol"},{"issue":"1","key":"4079_CR11","doi-asserted-by":"publisher","first-page":"20935","DOI":"10.1038\/s41598-021-00353-z","volume":"11","author":"D Rojoa","year":"2021","unstructured":"Rojoa D, Raheman F, Rassam J, Wade RG. Meta-analysis of the normal diffusion tensor imaging values of the median nerve and how they change in carpal tunnel syndrome. Sci Rep. 2021;11(1):20935.","journal-title":"Sci Rep"},{"issue":"11","key":"4079_CR12","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1007\/s00256-010-0974-5","volume":"39","author":"S Jambawalikar","year":"2010","unstructured":"Jambawalikar S, Baum J, Button T, Li H, Geronimo V, Gould ES. Diffusion tensor imaging of peripheral nerves. Skeletal Radiol. 2010;39(11):1073\u20139.","journal-title":"Skeletal Radiol"},{"issue":"5","key":"4079_CR13","doi-asserted-by":"publisher","first-page":"2625","DOI":"10.1152\/jn.00937.2004","volume":"93","author":"GS Dhillon","year":"2005","unstructured":"Dhillon GS, Kr\u00fcger TB, Sandhu JS, Horch KW. Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees. J Neurophysiol. 2005;93(5):2625\u201333.","journal-title":"J Neurophysiol"},{"issue":"6","key":"4079_CR14","doi-asserted-by":"publisher","first-page":"066040","DOI":"10.1088\/1741-2552\/ab4370","volume":"16","author":"CK Overstreet","year":"2019","unstructured":"Overstreet CK, Cheng J, Keefer EW. Fascicle specific targeting for selective peripheral nerve stimulation. J Neural Eng. 2019;16(6):066040.","journal-title":"J Neural Eng"},{"issue":"5","key":"4079_CR15","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1109\/TNSRE.2008.2006207","volume":"16","author":"S Micera","year":"2008","unstructured":"Micera S, Navarro X, Carpaneto J, Citi L, Tonet O, Rossini PM, et al. On the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputees. IEEE Trans Neural Syst Rehabil Eng. 2008;16(5):453\u201372.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"4079_CR16","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.pmrj.2010.06.016","volume":"3","author":"AE Schultz","year":"2011","unstructured":"Schultz AE, Kuiken TA. Neural interfaces for control of upper limb prostheses: the state of the art and future possibilities. PM&R. 2011;3(1):55\u201367.","journal-title":"PM&R"}],"container-title":["Skeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-022-04079-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00256-022-04079-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-022-04079-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,10]],"date-time":"2022-09-10T03:41:25Z","timestamp":1662781285000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00256-022-04079-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,30]]},"references-count":16,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["4079"],"URL":"https:\/\/doi.org\/10.1007\/s00256-022-04079-5","relation":{},"ISSN":["0364-2348","1432-2161"],"issn-type":[{"value":"0364-2348","type":"print"},{"value":"1432-2161","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,30]]},"assertion":[{"value":"28 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Avneesh Chhabra serves as a consultant to ICON Medical and Treace Medical Concepts, Inc. Avneesh Chhabra receives royalties from Jaypee and Wolters, has grant support from Image Biopsy Lab, Inc., is a speaker for Siemens, and is also on medical advisory board of Image Biopsy Lab, Inc.Jonathan Cheng and Edward Keefer are both co-owners of Nerves Incorporated which conducted this research sponsored by the DARPA HAPTIX (Hand Proprioceptive and Touch Interfaces) program under the US federal BRAIN initiative.Bayan Mogharrabi and Raghu Ratakonda declare that they have no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}