{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T07:04:22Z","timestamp":1791875062102,"version":"4.3.4"},"reference-count":75,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T00:00:00Z","timestamp":1744761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T00:00:00Z","timestamp":1744761600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Medizinische Hochschule Brandenburg CAMPUS GmbH"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Skeletal Radiol"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Computed tomography (CT) has traditionally been underutilized in the imaging of inflammatory arthritis due to its limitations in assessing soft tissue inflammation and concerns over radiation exposure. However, recent technological advancements have positioned CT as a more viable imaging modality for arthritis, offering high specificity and sensitivity in detecting structural bone changes. However, advances in ultra-low-dose CT protocols and AI-driven image reconstruction have significantly reduced radiation exposure while maintaining diagnostic quality. Dynamic CT and spectral CT techniques, including dual-energy CT (DECT), have broadened CT\u2019s application in assessing dynamic joint instabilities and visualizing inflammatory changes through material-specific imaging. Techniques such as CT subtraction imaging and iodine mapping have enhanced the detection of active soft-tissue inflammation, virtual non-calcium reconstructions, and the detection of bone marrow edema. Possible CT applications span various forms of arthritis, including gout, calcium pyrophosphate deposition disease (CPPD), psoriatic arthritis, and axial spondyloarthritis. Beyond its diagnostic capabilities, CT\u2019s ability to provide detailed structural assessment positions is a valuable tool for monitoring disease progression and therapeutic response, particularly in clinical trials. While MRI remains superior for soft tissue evaluation, CT\u2019s specificity for bone-related changes and its potential for integration into routine arthritis management warrant further exploration and research. This review explores the current and emerging roles of CT in arthritis diagnostics, with a focus on novel applications and future potential.<\/jats:p>","DOI":"10.1007\/s00256-025-04931-4","type":"journal-article","created":{"date-parts":[[2025,4,15]],"date-time":"2025-04-15T21:44:42Z","timestamp":1744753482000},"page":"2385-2397","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Current and future role of CT and advanced CT applications in inflammatory arthritis in the clinic and trials"],"prefix":"10.1007","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3593-1449","authenticated-orcid":false,"given":"Torsten","family":"Diekhoff","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sevtap Tugce","family":"Ulas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,16]]},"reference":[{"issue":"5","key":"4931_CR1","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1016\/j.jacr.2019.02.029","volume":"16","author":"M Torabi","year":"2019","unstructured":"Torabi M, Lenchik L, Beaman FD, et al. ACR Appropriateness Criteria\u00ae acute hand and wrist trauma. J Am Coll Radiol. 2019;16(5):S7\u201317.","journal-title":"J Am Coll Radiol"},{"key":"4931_CR2","doi-asserted-by":"publisher","first-page":"1759720X2412873","DOI":"10.1177\/1759720X241287373","volume":"16","author":"ST Ulas","year":"2024","unstructured":"Ulas ST, Diekhoff T. Computed tomography\u2014current status and future directions for arthritis imaging. Ther Adv Musculoskelet Dis. 2024;16:1759720X241287373.","journal-title":"Ther Adv Musculoskelet Dis."},{"key":"4931_CR3","doi-asserted-by":"crossref","unstructured":"Teh J, McQueen F, Eshed I, Plagou A, Klauser A. Advanced imaging in the diagnosis of gout and other crystal arthropathies. Seminars in musculoskeletal radiology. Thieme Medical Publishers. 2018;225\u2013236","DOI":"10.1055\/s-0038-1639484"},{"issue":"2","key":"4931_CR4","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1136\/annrheumdis-2021-220136","volume":"81","author":"T Diekhoff","year":"2022","unstructured":"Diekhoff T, Eshed I, Radny F, et al. Choose wisely: imaging for diagnosis of axial spondyloarthritis. Ann Rheum Dis. 2022;81(2):237\u201342.","journal-title":"Ann Rheum Dis"},{"issue":"1","key":"4931_CR5","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1136\/annrheumdis-2018-213904","volume":"78","author":"T Diekhoff","year":"2019","unstructured":"Diekhoff T, Ulas ST, Poddubnyy D, et al. Ultra-low-dose CT detects synovitis in patients with suspected rheumatoid arthritis. Ann Rheum Dis. 2019;78(1):31\u20135.","journal-title":"Ann Rheum Dis"},{"key":"4931_CR6","doi-asserted-by":"publisher","unstructured":"Omoumi P, Verdun FR, Becce F. Optimization of radiation dose and image quality in musculoskeletal CT: emphasis on Iterative Reconstruction Techniques (Part 2). Semin Musculoskelet Radiol. 2015;19(5):422\u201330. https:\/\/doi.org\/10.1055\/s-0035-1569254.","DOI":"10.1055\/s-0035-1569254"},{"issue":"2","key":"4931_CR7","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s00256-021-03802-y","volume":"51","author":"J Fritz","year":"2022","unstructured":"Fritz J, Kijowski R, Recht MP. Artificial intelligence in musculoskeletal imaging: a perspective on value propositions, clinical use, and obstacles. Skeletal Radiol. 2022;51(2):239\u201343.","journal-title":"Skeletal Radiol"},{"issue":"1","key":"4931_CR8","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1097\/RLI.0000000000000908","volume":"58","author":"HA Ibad","year":"2023","unstructured":"Ibad HA, de Cesar NC, Shakoor D, et al. Computed tomography: state-of-the-art advancements in musculoskeletal imaging. Invest Radiol. 2023;58(1):99\u2013110.","journal-title":"Invest Radiol"},{"key":"4931_CR9","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1007\/s00256-019-03309-7","volume":"49","author":"Z Alagic","year":"2020","unstructured":"Alagic Z, Bujila R, Enocson A, Srivastava S, Koskinen SK. Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects. Skeletal Radiol. 2020;49:531\u20139.","journal-title":"Skeletal Radiol"},{"key":"4931_CR10","doi-asserted-by":"publisher","first-page":"104214","DOI":"10.1016\/j.medengphy.2024.104214","volume":"130","author":"RL Lawrence","year":"2024","unstructured":"Lawrence RL, Nicholson L, Lee EC, Napier K, Zmistowski B, Rainbow MJ. Geometric accuracy of low-dose CT scans for use in shoulder musculoskeletal research applications. Med Eng Phys. 2024;130:104214.","journal-title":"Med Eng Phys"},{"issue":"3","key":"4931_CR11","doi-asserted-by":"publisher","first-page":"e230193","DOI":"10.1148\/radiol.230193","volume":"308","author":"S Orkut","year":"2023","unstructured":"Orkut S, Gillet R, Granero J, et al. Assessment of scapholunate instability on 4D CT scans in patients with inconclusive conventional images. Radiology. 2023;308(3):e230193.","journal-title":"Radiology"},{"issue":"2","key":"4931_CR12","doi-asserted-by":"publisher","first-page":"e230344","DOI":"10.1148\/radiol.230344","volume":"308","author":"S Demehri","year":"2023","unstructured":"Demehri S, Baffour FI, Klein JG, et al. Musculoskeletal CT imaging: state-of-the-art advancements and future directions. Radiology. 2023;308(2):e230344.","journal-title":"Radiology"},{"issue":"1","key":"4931_CR13","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1007\/s00256-020-03526-5","volume":"50","author":"ST Ulas","year":"2021","unstructured":"Ulas ST, Hermann KG, Makowski MR, et al. Perfusion in hand arthritis on dynamic contrast-enhanced computed tomography: a randomized prospective study using MRI as a standard of reference. Skeletal Radiol. 2021;50(1):59\u201368.","journal-title":"Skeletal Radiol"},{"issue":"11","key":"4931_CR14","doi-asserted-by":"publisher","first-page":"7590","DOI":"10.1007\/s00330-022-08746-y","volume":"32","author":"S Orkut","year":"2022","unstructured":"Orkut S, Gillet R, Hossu G, et al. Kinematic 4D CT case-control study of wrist in dart throwing motion \u201cin vivo\u201d: comparison with other maneuvers. Eur Radiol. 2022;32(11):7590\u2013600.","journal-title":"Eur Radiol"},{"issue":"9746","key":"4931_CR15","doi-asserted-by":"publisher","first-page":"1094","DOI":"10.1016\/S0140-6736(10)60826-4","volume":"376","author":"DL Scott","year":"2010","unstructured":"Scott DL, Wolfe F, Huizinga TW. Rheumatoid arthritis. Lancet. 2010;376(9746):1094\u2013108.","journal-title":"Lancet"},{"issue":"6","key":"4931_CR16","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1136\/annrheumdis-2016-210602","volume":"76","author":"B Combe","year":"2017","unstructured":"Combe B, Landewe R, Daien CI, et al. 2016 update of the EULAR recommendations for the management of early arthritis. Ann Rheum Dis. 2017;76(6):948\u201359.","journal-title":"Ann Rheum Dis"},{"issue":"9","key":"4931_CR17","doi-asserted-by":"publisher","first-page":"6376","DOI":"10.1007\/s00330-022-08744-0","volume":"32","author":"ST Ulas","year":"2022","unstructured":"Ulas ST, Ziegeler K, Richter ST, et al. Contrast-enhanced CT techniques and MRI perform equally well in arthritis imaging of the hand: a prospective diagnostic accuracy study. Eur Radiol. 2022;32(9):6376\u201383.","journal-title":"Eur Radiol"},{"issue":"3","key":"4931_CR18","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.nic.2017.03.002","volume":"27","author":"R Forghani","year":"2017","unstructured":"Forghani R, De Man B, Gupta R. Dual-energy computed tomography: physical principles, approaches to scanning, usage, and implementation: Part 1. Neuroimaging Clin N Am. 2017;27(3):371\u201384.","journal-title":"Neuroimaging Clin N Am"},{"issue":"6","key":"4931_CR19","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1007\/s00330-006-0517-6","volume":"17","author":"TR Johnson","year":"2007","unstructured":"Johnson TR, Krauss B, Sedlmair M, et al. Material differentiation by dual energy CT: initial experience. Eur Radiol. 2007;17(6):1510\u20137.","journal-title":"Eur Radiol"},{"issue":"6","key":"4931_CR20","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1136\/annrheumdis-2013-205095","volume":"74","author":"T Bongartz","year":"2015","unstructured":"Bongartz T, Glazebrook KN, Kavros SJ, et al. Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. Ann Rheum Dis. 2015;74(6):1072\u20137.","journal-title":"Ann Rheum Dis"},{"issue":"10","key":"4931_CR21","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1136\/ard.2008.099713","volume":"68","author":"HK Choi","year":"2009","unstructured":"Choi HK, Al-Arfaj AM, Eftekhari A, et al. Dual energy computed tomography in tophaceous gout. Ann Rheum Dis. 2009;68(10):1609\u201312.","journal-title":"Ann Rheum Dis"},{"issue":"1","key":"4931_CR22","doi-asserted-by":"publisher","first-page":"34","DOI":"10.3390\/gucdd2010003","volume":"2","author":"S Ottaviani","year":"2024","unstructured":"Ottaviani S. Imaging follow-up of MSU crystal depletion. Gout, Urate, and Crystal Deposition Disease. 2024;2(1):34\u201344.","journal-title":"Gout, Urate, and Crystal Deposition Disease"},{"issue":"1","key":"4931_CR23","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1148\/radiol.2021203624","volume":"300","author":"F Ghazi Sherbaf","year":"2021","unstructured":"Ghazi Sherbaf F, Sair HI, Shakoor D, et al. DECT in detection of vertebral fracture-associated bone marrow edema: a systematic review and meta-analysis with emphasis on technical and imaging interpretation parameters. Radiology. 2021;300(1):110\u20139.","journal-title":"Radiology"},{"issue":"2","key":"4931_CR24","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s00256-016-2533-1","volume":"46","author":"T Diekhoff","year":"2017","unstructured":"Diekhoff T, Scheel M, Hermann S, Mews J, Hamm B, Hermann KA. Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout. Skeletal Radiol. 2017;46(2):185\u201390.","journal-title":"Skeletal Radiol"},{"issue":"6","key":"4931_CR25","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1136\/annrheumdis-2018-213152","volume":"77","author":"L Jans","year":"2018","unstructured":"Jans L, De Kock I, Herregods N, et al. Dual-energy CT: a new imaging modality for bone marrow oedema in rheumatoid arthritis. Ann Rheum Dis. 2018;77(6):958\u201360.","journal-title":"Ann Rheum Dis"},{"key":"4931_CR26","doi-asserted-by":"publisher","unstructured":"Fukuda T, Umezawa Y, Tojo S, Yonenaga T, Asahina A, Nakagawa H, Fukuda K. Initial Experience of using dual-energy ct with an iodine overlay image for hand psoriatic arthritis: comparison study with contrast-enhanced MR imaging. Radiology. 2017;284(1):134\u2013142. https:\/\/doi.org\/10.1148\/radiol.2016161671.","DOI":"10.1148\/radiol.2016161671"},{"key":"4931_CR27","doi-asserted-by":"publisher","first-page":"100383","DOI":"10.1016\/j.ejro.2021.100383","volume":"8","author":"S Ogiwara","year":"2021","unstructured":"Ogiwara S, Fukuda T, Kawakami R, Ojiri H, Fukuda K. Anatomical analysis of inflammation in hand psoriatic arthritis by dual-energy CT iodine map. Eur J Radiol Open. 2021;8:100383.","journal-title":"Eur J Radiol Open"},{"issue":"1","key":"4931_CR28","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1038\/s41598-020-58235-9","volume":"10","author":"R Kayama","year":"2020","unstructured":"Kayama R, Fukuda T, Ogiwara S, et al. Quantitative analysis of therapeutic response in psoriatic arthritis of digital joints with dual-energy CT iodine maps. Sci Rep. 2020;10(1):1225.","journal-title":"Sci Rep"},{"issue":"12","key":"4931_CR29","doi-asserted-by":"publisher","first-page":"2966","DOI":"10.3390\/diagnostics12122966","volume":"12","author":"TM Wittig","year":"2022","unstructured":"Wittig TM, Ziegeler K, Kreutzinger V, et al. Dual-energy computed tomography collagen density mapping of the cranio-cervical ligaments-a retrospective feasibility study. Diagnostics (Basel). 2022;12(12):2966.","journal-title":"Diagnostics (Basel)"},{"issue":"8","key":"4931_CR30","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.3390\/diagnostics12081819","volume":"12","author":"ST Ulas","year":"2022","unstructured":"Ulas ST, Ziegeler K, Richter ST, et al. Virtual monochromatic images from dual-energy computed tomography do not improve the detection of synovitis in hand arthritis. Diagnostics (Basel). 2022;12(8):1819.","journal-title":"Diagnostics (Basel)"},{"issue":"4","key":"4931_CR31","doi-asserted-by":"publisher","first-page":"555","DOI":"10.3348\/kjr.2017.18.4.555","volume":"18","author":"HW Goo","year":"2017","unstructured":"Goo HW, Goo JM. Dual-energy CT: new horizon in medical imaging. Korean J Radiol. 2017;18(4):555\u201369.","journal-title":"Korean J Radiol"},{"issue":"2","key":"4931_CR32","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1148\/radiol.2015140857","volume":"276","author":"S Leng","year":"2015","unstructured":"Leng S, Yu L, Fletcher JG, McCollough CH. Maximizing iodine contrast-to-noise ratios in abdominal CT imaging through use of energy domain noise reduction and virtual monoenergetic dual-energy CT. Radiology. 2015;276(2):562\u201370.","journal-title":"Radiology"},{"issue":"2","key":"4931_CR33","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: technical principles and clinical prospects. Radiology. 2018;289(2):293\u2013312.","journal-title":"Radiology"},{"issue":"4","key":"4931_CR34","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.diii.2022.11.003","volume":"104","author":"J Greffier","year":"2023","unstructured":"Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023;104(4):167\u201377.","journal-title":"Diagn Interv Imaging"},{"key":"4931_CR35","doi-asserted-by":"publisher","unstructured":"Quintiens J, van Lenthe GH. Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints. Curr Osteoporos Rep. 2024;22(4):387\u201395. https:\/\/doi.org\/10.1007\/s11914-024-00876-0.","DOI":"10.1007\/s11914-024-00876-0"},{"key":"4931_CR36","doi-asserted-by":"publisher","unstructured":"Bayrak YE, \u00d6zer T, Anik Y, Balci S, Aydin D, \u015eahin N, S\u00f6nmez HE. Assessment of sacroiliitis using zero echo time magnetic resonance imaging: a comprehensive evaluation. Pediatr Radiol. 2025. https:\/\/doi.org\/10.1007\/s00247-025-06201-w.","DOI":"10.1007\/s00247-025-06201-w"},{"issue":"5","key":"4931_CR37","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1007\/s00256-018-3116-0","volume":"48","author":"ST Ulas","year":"2019","unstructured":"Ulas ST, Diekhoff T, Hermann KGA, Poddubnyy D, Hamm B, Makowski MR. Susceptibility-weighted MR imaging to improve the specificity of erosion detection: a prospective feasibility study in hand arthritis. Skeletal Radiol. 2019;48(5):721\u20138.","journal-title":"Skeletal Radiol"},{"issue":"1","key":"4931_CR38","doi-asserted-by":"publisher","first-page":"e002089","DOI":"10.1136\/rmdopen-2021-002089","volume":"8","author":"ST Ulas","year":"2022","unstructured":"Ulas ST, Ziegeler K, Richter ST, et al. CT-like images in MRI improve specificity of erosion detection in patients with hand arthritis: a diagnostic accuracy study with CT as standard of reference. RMD Open. 2022;8(1):e002089.","journal-title":"RMD Open"},{"issue":"2","key":"4931_CR39","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1148\/radiol.2020201537","volume":"298","author":"LBO Jans","year":"2021","unstructured":"Jans LBO, Chen M, Elewaut D, et al. MRI-based synthetic CT in the detection of structural lesions in patients with suspected Sacroiliitis: comparison with MRI. Radiology. 2021;298(2):343\u20139.","journal-title":"Radiology"},{"key":"4931_CR40","doi-asserted-by":"publisher","unstructured":"Sudo\u0142-Szopi\u0144ska I, Lanckoro\u0144ski M, Teh J, Diekhoff T, Giraudo C, Chaudhary SR. Advanced Imaging of Gout and Other Inflammatory Diseases Around the Knee. Semin Musculoskelet Radiol. 2024;28(3):337\u2013351. https:\/\/doi.org\/10.1055\/s-0044-1785471.","DOI":"10.1055\/s-0044-1785471"},{"issue":"10","key":"4931_CR41","doi-asserted-by":"publisher","first-page":"1789","DOI":"10.1136\/annrheumdis-2015-208237","volume":"74","author":"T Neogi","year":"2015","unstructured":"Neogi T, Jansen TL, Dalbeth N, et al. 2015 Gout classification criteria: an American College of Rheumatology\/European League Against Rheumatism collaborative initiative. Ann Rheum Dis. 2015;74(10):1789\u201398.","journal-title":"Ann Rheum Dis"},{"key":"4931_CR42","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s00256-016-2533-1","volume":"46","author":"T Diekhoff","year":"2017","unstructured":"Diekhoff T, Scheel M, Hermann S, Mews J, Hamm B, Hermann KGA. Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout. Skeletal Radiol. 2017;46:185\u201390.","journal-title":"Skeletal Radiol"},{"issue":"6","key":"4931_CR43","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1007\/s00296-014-2979-1","volume":"34","author":"A Huppertz","year":"2014","unstructured":"Huppertz A, Hermann KG, Diekhoff T, Wagner M, Hamm B, Schmidt WA. Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout. Rheumatol Int. 2014;34(6):763\u201371.","journal-title":"Rheumatol Int"},{"key":"4931_CR44","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s00256-013-1771-8","volume":"43","author":"PI Mallinson","year":"2014","unstructured":"Mallinson PI, Reagan AC, Coupal T, Munk PL, Ouellette H, Nicolaou S. The distribution of urate deposition within the extremities in gout: a review of 148 dual-energy CT cases. Skeletal Radiol. 2014;43:277\u201381.","journal-title":"Skeletal Radiol"},{"key":"4931_CR45","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-016-0943-9","volume":"17","author":"AN Baer","year":"2016","unstructured":"Baer AN, Kurano T, Thakur UJ, et al. Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout. BMC Musculoskelet Disord. 2016;17:1\u20139.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"4931_CR46","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1097\/RLI.0000000000000099","volume":"50","author":"T Diekhoff","year":"2015","unstructured":"Diekhoff T, Kiefer T, Stroux A, et al. Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies. Invest Radiol. 2015;50(4):255\u201360.","journal-title":"Invest Radiol"},{"issue":"10","key":"4931_CR47","doi-asserted-by":"publisher","first-page":"4861","DOI":"10.1093\/rheumatology\/keaa923","volume":"60","author":"JA Singh","year":"2021","unstructured":"Singh JA, Budzik J-F, Becce F, Pascart T. Dual-energy computed tomography vs ultrasound, alone or combined, for the diagnosis of gout: a prospective study of accuracy. Rheumatology. 2021;60(10):4861\u20137.","journal-title":"Rheumatology"},{"issue":"1","key":"4931_CR48","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s41747-023-00348-7","volume":"7","author":"M Kotlyarov","year":"2023","unstructured":"Kotlyarov M, Mews J, Ulas ST, Ziegeler K, Hamm B, Diekhoff T. Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration. European Radiology Experimental. 2023;7(1):43.","journal-title":"European Radiology Experimental"},{"issue":"1","key":"4931_CR49","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1186\/s41747-024-00466-w","volume":"8","author":"K Khayata","year":"2024","unstructured":"Khayata K, Diekhoff T, Mews J, Schmolke S, Kotlyarov M. Virtual noncontrast images reveal gouty tophi in contrast-enhanced dual-energy CT: a phantom study. European Radiology Experimental. 2024;8(1):69.","journal-title":"European Radiology Experimental"},{"key":"4931_CR50","doi-asserted-by":"publisher","first-page":"109692","DOI":"10.1016\/j.ejrad.2021.109692","volume":"139","author":"M Kotlyarov","year":"2021","unstructured":"Kotlyarov M, Hermann KGA, Mews J, Hamm B, Diekhoff T. Dual-energy computed tomography: tube current settings and detection of uric acid tophi. Eur J Radiol. 2021;139:109692.","journal-title":"Eur J Radiol"},{"issue":"1","key":"4931_CR51","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1186\/s41747-024-00528-z","volume":"8","author":"T Diekhoff","year":"2024","unstructured":"Diekhoff T, Schmolke SA, Khayata K, Mews J, Kotlyarov M. Material decomposition approaches for monosodium urate (MSU) quantification in gouty arthritis: a (bio) phantom study. European Radiology Experimental. 2024;8(1):127.","journal-title":"European Radiology Experimental"},{"issue":"1","key":"4931_CR52","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1097\/RLI.0000000000000402","volume":"53","author":"T Diekhoff","year":"2018","unstructured":"Diekhoff T, Kotlyarov M, Mews J, Hamm B, Hermann KGA. Iterative reconstruction may improve diagnosis of gout: an ex vivo (bio) phantom dual-energy computed tomography study. Investigative Radiology. 2018;53(1):6\u201312.","journal-title":"Investigative Radiology"},{"issue":"7081","key":"4931_CR53","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1038\/nature04516","volume":"440","author":"F Martinon","year":"2006","unstructured":"Martinon F, Petrilli V, Mayor A, Tardivel A, Tschopp J. Gout-associated uric acid crystals activate the NALP3 inflammasome. Nature. 2006;440(7081):237\u201341.","journal-title":"Nature"},{"issue":"6","key":"4931_CR54","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1136\/ard-2023-224771","volume":"83","author":"P Mandl","year":"2024","unstructured":"Mandl P, D\u2019Agostino MA, Navarro-Compan V, et al. 2023 EULAR recommendations on imaging in diagnosis and management of crystal-induced arthropathies in clinical practice. Ann Rheum Dis. 2024;83(6):752\u20139.","journal-title":"Ann Rheum Dis"},{"issue":"5","key":"4931_CR55","first-page":"826","volume":"37","author":"K Ziegeler","year":"2019","unstructured":"Ziegeler K, Diekhoff T, Hermann S, Hamm B, Hermann KGA. Low-dose computed tomography as diagnostic tool in calcium pyrophosphate deposition disease arthropathy: focus on ligamentous calcifications of the wrist. Clin Exp Rheumatol. 2019;37(5):826\u201333.","journal-title":"Clin Exp Rheumatol"},{"issue":"2","key":"4931_CR56","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s00256-020-03580-z","volume":"50","author":"K Ziegeler","year":"2021","unstructured":"Ziegeler K, Richter ST, Hermann S, Hermann KGA, Hamm B, Diekhoff T. Dual-energy CT collagen density mapping of wrist ligaments reveals tissue remodeling in CPPD patients: first results from a clinical cohort. Skeletal Radiol. 2021;50(2):417\u201323.","journal-title":"Skeletal Radiol"},{"key":"4931_CR57","doi-asserted-by":"publisher","unstructured":"Ulas ST, Pochandke L, Ohrndorf S, Diekhoff T, Ziegeler K. Four-dimensional computed tomography detects dynamic three-dimensional pathologies of the wrist in patients with calcium pyrophosphate deposition disease. Front Med (Lausanne). 2023;10:1231667. https:\/\/doi.org\/10.3389\/fmed.2023.1231667","DOI":"10.3389\/fmed.2023.1231667"},{"key":"4931_CR58","doi-asserted-by":"publisher","first-page":"1231667","DOI":"10.3389\/fmed.2023.1231667","volume":"10","author":"ST Ulas","year":"2023","unstructured":"Ulas ST, Pochandke L, Ohrndorf S, Diekhoff T, Ziegeler K. Four-dimensional computed tomography detects dynamic three-dimensional pathologies of the wrist in patients with calcium pyrophosphate deposition disease. Front Med. 2023;10:1231667.","journal-title":"Front Med"},{"issue":"7","key":"4931_CR59","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1136\/annrheumdis-2013-204627","volume":"73","author":"M Cross","year":"2014","unstructured":"Cross M, Smith E, Hoy D, et al. The global burden of rheumatoid arthritis: estimates from the global burden of disease 2010 study. Ann Rheum Dis. 2014;73(7):1316\u201322.","journal-title":"Ann Rheum Dis"},{"issue":"3","key":"4931_CR60","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.semarthrit.2012.03.016","volume":"42","author":"J Narvaez","year":"2012","unstructured":"Narvaez J, Narvaez JA, de Albert M, Gomez-Vaquero C, Nolla JM. Can magnetic resonance imaging of the hand and wrist differentiate between rheumatoid arthritis and psoriatic arthritis in the early stages of the disease? Semin Arthritis Rheum. 2012;42(3):234\u201345.","journal-title":"Semin Arthritis Rheum"},{"issue":"Suppl 2","key":"4931_CR61","doi-asserted-by":"publisher","first-page":"18","DOI":"10.3899\/jrheum.2023-0518","volume":"50","author":"M Ostergaard","year":"2023","unstructured":"Ostergaard M, Maksymowych WP. Advances in the evaluation of peripheral enthesitis by magnetic resonance imaging in patients with psoriatic arthritis. J Rheumatol. 2023;50(Suppl 2):18\u201322.","journal-title":"J Rheumatol"},{"issue":"6","key":"4931_CR62","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1007\/s11926-022-01075-5","volume":"24","author":"T Diekhoff","year":"2022","unstructured":"Diekhoff T, Hermann KGA, Lambert RG. Future of low-dose computed tomography and dual-energy computed tomography in axial spondyloarthritis. Curr Rheumatol Rep. 2022;24(6):198\u2013205.","journal-title":"Curr Rheumatol Rep"},{"issue":"4","key":"4931_CR63","doi-asserted-by":"publisher","first-page":"776","DOI":"10.3390\/diagnostics13040776","volume":"13","author":"D Deppe","year":"2023","unstructured":"Deppe D, Ziegeler K, Hermann KGA, et al. Dual-energy-CT for osteitis and fat lesions in axial spondyloarthritis: how feasible is low-dose scanning? Diagnostics. 2023;13(4):776.","journal-title":"Diagnostics"},{"key":"4931_CR64","doi-asserted-by":"publisher","first-page":"3393","DOI":"10.1007\/s00330-020-06670-7","volume":"30","author":"M Chen","year":"2020","unstructured":"Chen M, Herregods N, Jaremko JL, et al. Bone marrow edema in sacroiliitis: detection with dual-energy CT. Eur Radiol. 2020;30:3393\u2013400.","journal-title":"Eur Radiol"},{"key":"4931_CR65","doi-asserted-by":"publisher","unstructured":"Vereecke E, Diekhoff T, Eshed I, Herregods N, Morb\u00e9e L, Jaremko JL, Jans L. ESR Essentials: Imaging of sacroiliitis-practice recommendations by ESSR. Eur Radiol. 2024;34(9):5773\u201382. https:\/\/doi.org\/10.1007\/s00330-024-10653-3.","DOI":"10.1007\/s00330-024-10653-3"},{"issue":"11","key":"4931_CR66","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1038\/s41584-019-0309-4","volume":"15","author":"WP Maksymowych","year":"2019","unstructured":"Maksymowych WP. The role of imaging in the diagnosis and management of axial spondyloarthritis. Nat Rev Rheumatol. 2019;15(11):657\u201372.","journal-title":"Nat Rev Rheumatol"},{"issue":"9","key":"4931_CR67","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1007\/s00256-022-04018-4","volume":"51","author":"T Diekhoff","year":"2022","unstructured":"Diekhoff T, Lambert R, Hermann KG. MRI in axial spondyloarthritis: understanding an \u2018ASAS-positive MRI\u2019 and the ASAS classification criteria. Skeletal Radiol. 2022;51(9):1721\u201330.","journal-title":"Skeletal Radiol"},{"issue":"9","key":"4931_CR68","doi-asserted-by":"publisher","first-page":"1502","DOI":"10.1136\/annrheumdis-2016-210640","volume":"76","author":"T Diekhoff","year":"2017","unstructured":"Diekhoff T, Hermann KG, Greese J, et al. Comparison of MRI with radiography for detecting structural lesions of the sacroiliac joint using CT as standard of reference: results from the SIMACT study. Ann Rheum Dis. 2017;76(9):1502\u20138.","journal-title":"Ann Rheum Dis"},{"issue":"1","key":"4931_CR69","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1093\/rheumatology\/keab318","volume":"61","author":"K Ziegeler","year":"2022","unstructured":"Ziegeler K, Kreutzinger V, Proft F, Poddubnyy D, Hermann KGA, Diekhoff T. Joint anatomy in axial spondyloarthritis: strong associations between sacroiliac joint form variation and symptomatic disease. Rheumatology. 2022;61(1):388\u201393.","journal-title":"Rheumatology"},{"issue":"3","key":"4931_CR70","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1093\/rheumatology\/keac282","volume":"62","author":"K Ziegeler","year":"2023","unstructured":"Ziegeler K, Ulas ST, Poddubnyy D, et al. Anatomical variation of the sacroiliac joint carries an increased risk for erosion and bone marrow oedema in axial spondyloarthritis. Rheumatology. 2023;62(3):1117\u201323.","journal-title":"Rheumatology"},{"issue":"11","key":"4931_CR71","doi-asserted-by":"publisher","first-page":"8310","DOI":"10.1007\/s00330-023-09704-y","volume":"33","author":"T Van Den Berghe","year":"2023","unstructured":"Van Den Berghe T, Babin D, Chen M, et al. Neural network algorithm for detection of erosions and ankylosis on CT of the sacroiliac joints: multicentre development and validation of diagnostic accuracy. Eur Radiol. 2023;33(11):8310\u201323.","journal-title":"Eur Radiol"},{"issue":"3","key":"4931_CR72","doi-asserted-by":"publisher","first-page":"101876","DOI":"10.1016\/j.berh.2023.101876","volume":"37","author":"K Di Dier","year":"2023","unstructured":"Di Dier K, Deppe D, Diekhoff T, Herregods N, Jans L. Clash of the titans: current CT and CT-like imaging modalities in sacroiliitis in spondyloarthritis. Best Pract Res Clin Rheumatol. 2023;37(3):101876.","journal-title":"Best Pract Res Clin Rheumatol"},{"issue":"12","key":"4931_CR73","doi-asserted-by":"publisher","first-page":"3776","DOI":"10.1093\/rheumatology\/keaa155","volume":"59","author":"R Stal","year":"2020","unstructured":"Stal R, van Gaalen F, Sepriano A, et al. Facet joint ankylosis in r-axSpA: detection and 2-year progression on whole spine low-dose CT and comparison with syndesmophyte progression. Rheumatology (Oxford). 2020;59(12):3776\u201383.","journal-title":"Rheumatology (Oxford)"},{"issue":"2","key":"4931_CR74","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1136\/annrheumdis-2017-211989","volume":"77","author":"A de Koning","year":"2018","unstructured":"de Koning A, de Bruin F, van den Berg R, et al. Low-dose CT detects more progression of bone formation in comparison to conventional radiography in patients with ankylosing spondylitis: results from the SIAS cohort. Ann Rheum Dis. 2018;77(2):293\u20139.","journal-title":"Ann Rheum Dis"},{"issue":"3","key":"4931_CR75","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1136\/annrheumdis-2017-212553","volume":"77","author":"F de Bruin","year":"2018","unstructured":"de Bruin F, de Koning A, van den Berg R, et al. Development of the CT Syndesmophyte Score (CTSS) in patients with ankylosing spondylitis: data from the SIAS cohort. Ann Rheum Dis. 2018;77(3):371\u20137.","journal-title":"Ann Rheum Dis"}],"container-title":["Skeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-025-04931-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00256-025-04931-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-025-04931-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T10:04:34Z","timestamp":1758708274000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00256-025-04931-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,16]]},"references-count":75,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["4931"],"URL":"https:\/\/doi.org\/10.1007\/s00256-025-04931-4","relation":{},"ISSN":["0364-2348","1432-2161"],"issn-type":[{"value":"0364-2348","type":"print"},{"value":"1432-2161","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,16]]},"assertion":[{"value":"4 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 April 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"TD: speaker: Novartis, MSD, UCB, Janssen, Eli Lilly, Canon MS, Berlinflame, Bracco; Advisory board: Eli Lilly, AbbVie, UCB; TU: none were declared.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}