{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T01:45:28Z","timestamp":1782524728153,"version":"3.54.5"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T00:00:00Z","timestamp":1769472000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T00:00:00Z","timestamp":1769472000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Skeletal Radiol"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s00256-026-05136-z","type":"journal-article","created":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T05:20:07Z","timestamp":1769491207000},"page":"2087-2097","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Optimizing knee MRI near orthopedic hardware using a 3D-printed anatomical phantom"],"prefix":"10.1007","volume":"55","author":[{"given":"William","family":"Tracqui","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Habeeb","family":"Yusuff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucile","family":"Hausser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Tournayre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guillaume","family":"Bierry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Philippe","family":"Dillenseger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7646-9724","authenticated-orcid":false,"given":"Thibault","family":"Willaume","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,27]]},"reference":[{"issue":"4","key":"5136_CR1","doi-asserted-by":"publisher","first-page":"780","DOI":"10.2106\/JBJS.F.00222","volume":"89","author":"S Kurtz","year":"2007","unstructured":"Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780\u20135. https:\/\/doi.org\/10.2106\/JBJS.F.00222.","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"5136_CR2","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.ocl.2019.11.003","volume":"51","author":"MS Abdelaal","year":"2020","unstructured":"Abdelaal MS, Restrepo C, Sharkey PF. Global perspectives on arthroplasty of hip and knee joints. Orthop Clin North Am. 2020;51(2):169\u201376. https:\/\/doi.org\/10.1016\/j.ocl.2019.11.003.","journal-title":"Orthop Clin North Am"},{"issue":"9","key":"5136_CR3","doi-asserted-by":"publisher","first-page":"1727","DOI":"10.1007\/s00256-024-04601-x","volume":"53","author":"CB Chung","year":"2024","unstructured":"Chung CB, Pathria MN, Resnick D. MRI in MSK\u202f: is it the ultimate examination? Skeletal Radiol. 2024;53(9):1727\u201335. https:\/\/doi.org\/10.1007\/s00256-024-04601-x.","journal-title":"Skeletal Radiol"},{"key":"5136_CR4","doi-asserted-by":"publisher","DOI":"10.1038\/s44172-024-00218-z","volume":"3","author":"S Manohar","year":"2024","unstructured":"Manohar S, Sechopoulos I, Anastasio MA, Maier-Hein L, Gupta R. Super phantoms\u202f: advanced models for testing medical imaging technologies. Commun Eng. 2024;3:73. https:\/\/doi.org\/10.1038\/s44172-024-00218-z.","journal-title":"Commun Eng"},{"key":"5136_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2024.104832","volume":"127","author":"H Yusuff","year":"2024","unstructured":"Yusuff H, Zorn PE, Blindauer F, Kharouf N, Semeril D, Bierry G, et al. High-fidelity anatomical phantoms for MRI practical training. Physica Medica: PM: An International Journal Devoted to the Applications of Physics to Medicine and Biology: Official Journal of the Italian Association of Biomedical Physics (AIFB). 2024;127:104832. https:\/\/doi.org\/10.1016\/j.ejmp.2024.104832.","journal-title":"Physica Medica: PM: An International Journal Devoted to the Applications of Physics to Medicine and Biology: Official Journal of the Italian Association of Biomedical Physics (AIFB)"},{"issue":"3","key":"5136_CR6","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1007\/s10334-024-01217-z","volume":"38","author":"H Yusuff","year":"2025","unstructured":"Yusuff H, Zorn P-E, Giraudeau C, Wach B, Choquet P, Chatelin S, et al. Development of a cost-effective 3D-printed MRI phantom for enhanced teaching of system performance and image quality concepts. Magma (New York, NY). 2025;38(3):561\u201374. https:\/\/doi.org\/10.1007\/s10334-024-01217-z.","journal-title":"Magma (New York, N.Y.)"},{"issue":"6","key":"5136_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.radi.2025.103195","volume":"31","author":"H Yusuff","year":"2025","unstructured":"Yusuff H, Willaume T, Breton E, Bierry G, Dillenseger J-P. Morphological MRI knee phantoms\u202f: design, preliminary results, and perspectives for applied research. Radiography. 2025;31(6):103195. https:\/\/doi.org\/10.1016\/j.radi.2025.103195.","journal-title":"Radiography"},{"issue":"2","key":"5136_CR8","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1002\/mrm.28740","volume":"86","author":"K Gopalan","year":"2021","unstructured":"Gopalan K, Tamir JI, Arias AC, Lustig M. Quantitative anatomy mimicking slice phantoms. Magn Reson Med. 2021;86(2):1159\u201366. https:\/\/doi.org\/10.1002\/mrm.28740.","journal-title":"Magn Reson Med"},{"issue":"2","key":"5136_CR9","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s10334-021-00953-w","volume":"35","author":"N Crasto","year":"2022","unstructured":"Crasto N, Kirubarajan A, Sussman D. Anthropomorphic brain phantoms for use in MRI systems\u202f: a systematic review. Magn Reson Mater Phys Biol Med. 2022;35(2):277\u201389. https:\/\/doi.org\/10.1007\/s10334-021-00953-w.","journal-title":"Magn Reson Mater Phys Biol Med"},{"issue":"6","key":"5136_CR10","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1016\/j.radi.2024.09.063","volume":"30","author":"H Yusuff","year":"2024","unstructured":"Yusuff H, Chatelin S, Dillenseger J-P. Narrative review of tissue-mimicking materials for MRI phantoms\u202f: composition, fabrication, and relaxation properties. Radiography (London, England: 1995). 2024;30(6):1655\u201368. https:\/\/doi.org\/10.1016\/j.radi.2024.09.063.","journal-title":"Radiography (London, England: 1995)"},{"key":"5136_CR11","doi-asserted-by":"crossref","unstructured":"McGarry CK, Grattan LJ, Ivory AM, Leek F, Liney GP, Liu Y, Miloro P, Rai R, Robinson AP, Shih AJ, Zeqiri B. Tissue mimicking materials for imaging and therapy phantoms: a review. Physics in Medicine & Biology. 2020 Dec 16;65(23):23TR01.","DOI":"10.1088\/1361-6560\/abbd17"},{"issue":"5","key":"5136_CR12","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13533","volume":"23","author":"A Antoniou","year":"2022","unstructured":"Antoniou A, Georgiou L, Christodoulou T, Panayiotou N, Ioannides C, Zamboglou N, et al. MR relaxation times of agar-based tissue-mimicking phantoms. J Appl Clin Med Phys. 2022;23(5):e13533. https:\/\/doi.org\/10.1002\/acm2.13533.","journal-title":"J Appl Clin Med Phys"},{"issue":"8","key":"5136_CR13","doi-asserted-by":"publisher","first-page":"4387","DOI":"10.1002\/mp.14986","volume":"48","author":"M Woletz","year":"2021","unstructured":"Woletz M, Roat S, Hummer A, Tik M, Windischberger C. Technical note\u202f: human tissue-equivalent MRI phantom preparation for 3 and 7 Tesla. Med Phys. 2021;48(8):4387\u201394. https:\/\/doi.org\/10.1002\/mp.14986.","journal-title":"Med Phys"},{"issue":"10","key":"5136_CR14","doi-asserted-by":"publisher","first-page":"3199","DOI":"10.1118\/1.2047807","volume":"32","author":"H Kato","year":"2005","unstructured":"Kato H, Kuroda M, Yoshimura K, Yoshida A, Hanamoto K, Kawasaki S, et al. Composition of MRI phantom equivalent to human tissues. Med Phys. 2005;32(10):3199\u2013208. https:\/\/doi.org\/10.1118\/1.2047807.","journal-title":"Med Phys"},{"issue":"2","key":"5136_CR15","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1093\/jrr\/rrz094","volume":"61","author":"M-J Kim","year":"2020","unstructured":"Kim M-J, Lee S-R, Song K-H, Baek H-M, Choe B-Y, Suh TS. Development of a hybrid magnetic resonance\/computed tomography-compatible phantom for magnetic resonance guided radiotherapy. J Radiat Res. 2020;61(2):314\u201324. https:\/\/doi.org\/10.1093\/jrr\/rrz094.","journal-title":"J Radiat Res"},{"issue":"3","key":"5136_CR16","doi-asserted-by":"publisher","first-page":"547","DOI":"10.2214\/AJR.11.7364","volume":"197","author":"BA Hargreaves","year":"2011","unstructured":"Hargreaves BA, Worters PW, Pauly KB, Pauly JM, Koch KM, Gold GE. Metal-induced artifacts in MRI. AJR Am J Roentgenol. 2011;197(3):547\u201355. https:\/\/doi.org\/10.2214\/AJR.11.7364.","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"5136_CR17","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1007\/s00256-016-2338-2","volume":"45","author":"JP Dillenseger","year":"2016","unstructured":"Dillenseger JP, Moli\u00e8re S, Choquet P, Goetz C, Ehlinger M, Bierry G. An illustrative review to understand and manage metal-induced artifacts in musculoskeletal MRI\u202f: a primer and updates. Skeletal Radiol. 2016;45(5):677\u201388. https:\/\/doi.org\/10.1007\/s00256-016-2338-2.","journal-title":"Skeletal Radiol"},{"issue":"9","key":"5136_CR18","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1007\/s00256-024-04624-4","volume":"53","author":"GC Feuerriegel","year":"2024","unstructured":"Feuerriegel GC, Sutter R. Managing hardware-related metal artifacts in MRI\u202f: current and evolving techniques. Skeletal Radiol. 2024;53(9):1737\u201350. https:\/\/doi.org\/10.1007\/s00256-024-04624-4.","journal-title":"Skeletal Radiol"},{"issue":"9","key":"5136_CR19","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1016\/j.spinee.2010.06.006","volume":"10","author":"PT Knott","year":"2010","unstructured":"Knott PT, Mardjetko SM, Kim RH, Cotter TM, Dunn MM, Patel ST, et al. A comparison of magnetic and radiographic imaging artifact after using three types of metal rods\u202f: stainless steel, titanium, and vitallium. Spine J. 2010;10(9):789\u201394. https:\/\/doi.org\/10.1016\/j.spinee.2010.06.006.","journal-title":"Spine J"},{"issue":"7","key":"5136_CR20","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20170361","volume":"47","author":"C Rendenbach","year":"2018","unstructured":"Rendenbach C, Schoellchen M, Bueschel J, Gauer T, Sedlacik J, Kutzner D, et al. Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation\u202f: an in vitro study @ 3\u00a0T. Dento MaxilloFacial Radiol. 2018;47(7):20170361. https:\/\/doi.org\/10.1259\/dmfr.20170361.","journal-title":"Dento MaxilloFacial Radiol"},{"key":"5136_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.socscimed.2022.115127","volume":"306","author":"S Sarkar","year":"2022","unstructured":"Sarkar S, Mateus S. Doing more with less\u2014how frugal innovations can contribute to improving healthcare systems. Soc Sci Med. 2022;306:115127. https:\/\/doi.org\/10.1016\/j.socscimed.2022.115127.","journal-title":"Soc Sci Med"},{"key":"5136_CR22","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000001249","author":"I Khodarahmi","year":"2025","unstructured":"Khodarahmi I, Walter W, Wojack P, Bruno M, Fritz J, Keerthivasan MB. Optimized variable flip angle technique for specific absorption rate reduction in metal artifact reduction magnetic resonance imaging. Invest Radiol. 2025. https:\/\/doi.org\/10.1097\/RLI.0000000000001249.","journal-title":"Invest Radiol"}],"container-title":["Skeletal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-026-05136-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00256-026-05136-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00256-026-05136-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T00:47:10Z","timestamp":1782521230000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00256-026-05136-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,27]]},"references-count":22,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["5136"],"URL":"https:\/\/doi.org\/10.1007\/s00256-026-05136-z","relation":{},"ISSN":["0364-2348","1432-2161"],"issn-type":[{"value":"0364-2348","type":"print"},{"value":"1432-2161","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,27]]},"assertion":[{"value":"23 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 January 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki, with no additional procedures or risks introduced beyond standard MRI practice. All participants provided informed consent to take part.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Conflict of interest"}}]}}