{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T07:49:22Z","timestamp":1789976962985,"version":"4.0.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2005,5,21]],"date-time":"2005-05-21T00:00:00Z","timestamp":1116633600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur J Nucl Med Mol Imaging"],"published-print":{"date-parts":[[2005,10]]},"DOI":"10.1007\/s00259-005-1784-1","type":"journal-article","created":{"date-parts":[[2005,5,20]],"date-time":"2005-05-20T09:03:53Z","timestamp":1116579833000},"page":"1167-1175","source":"Crossref","is-referenced-by-count":126,"title":["PET\/CT with intravenous contrast can be used for PET attenuation correction in cancer patients"],"prefix":"10.1007","volume":"32","author":[{"given":"A. K.","family":"Berthelsen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Holm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Loft","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. L.","family":"Klausen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Andersen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"H\u00f8jgaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,5,21]]},"reference":[{"key":"1784_CR1","volume-title":"Principles and practice of positron emission tomography","author":"RL Wahl","year":"2002","unstructured":"Wahl RL. Principles and practice of positron emission tomography. Philadelphia, PA: Lippincott Williams & Wilkins; 2002"},{"key":"1784_CR2","doi-asserted-by":"crossref","first-page":"2500","DOI":"10.1056\/NEJMoa022136","volume":"348","author":"D Lardinois","year":"2003","unstructured":"Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 2003;348:2500\u20137","journal-title":"N Engl J Med"},{"key":"1784_CR3","unstructured":"ACR practice guideline for the use of intravascular contrast media. Res 2002;51"},{"key":"1784_CR4","first-page":"56S","volume":"45","author":"G Antoch","year":"2004","unstructured":"Antoch G, Freudenberg LS, Beyer T, Bockisch A, Debatin J. To enhance or not to enhance? 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET\/CT. J Nucl Med 2004;45:56S\u201365S","journal-title":"J Nucl Med"},{"key":"1784_CR5","volume-title":"EUR 16262. European guidelines on quality criteria for computed tomography","author":"K Jessen","year":"2000","unstructured":"Jessen K, Panzer W, Shrimpton P. EUR 16262. European guidelines on quality criteria for computed tomography. Luxemburg: Office for Official publications of the European Communities; 2000"},{"key":"1784_CR6","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0031-9155\/44\/1\/001","volume":"44","author":"JH Hubbell","year":"1999","unstructured":"Hubbell JH. Review of photon interaction cross section data in the medical and biological context. Phys Med Biol 1999;44:R1\u201322","journal-title":"Phys Med Biol"},{"key":"1784_CR7","unstructured":"Hubbell JH, Seltzer SM (2004) Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients (version 1.4). [Online] Available: http:\/\/physics.nist.gov\/xaamdi [2004, November 11]. National Institute of Standards and Technology, Gaithersburg, MD. Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD (1995)"},{"key":"1784_CR8","doi-asserted-by":"crossref","first-page":"2285","DOI":"10.1109\/23.531893","volume":"43","author":"S Holm","year":"1996","unstructured":"Holm S, Toft PA, Jensen M. Estimation of the noise contributions from blank, transmission and emission scans in PET. IEEE Trans Nucl Sci 1996;43:2285\u201391","journal-title":"IEEE Trans Nucl Sci"},{"key":"1784_CR9","volume-title":"Clinical molecular anatomic imaging","author":"GK Schulthess von","year":"2003","unstructured":"von Schulthess GK. Clinical molecular anatomic imaging. Philadelphia, PA: Lippincott Williams & Wilkins; 2003"},{"issue":"Suppl 1","key":"1784_CR10","first-page":"25S","volume":"45","author":"T Beyer","year":"2004","unstructured":"Beyer T, Antoch G, Muller S, Egelhof T, Freudenberg LS, Debatin J, et al. Acquisition protocol considerations for combined PET\/CT imaging. J Nucl Med 2004;45 Suppl 1:25S\u201335S","journal-title":"J Nucl Med"},{"key":"1784_CR11","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.2214\/ajr.179.6.1791555","volume":"179","author":"G Antoch","year":"2002","unstructured":"Antoch G, Freudenberg LS, Stattaus J, Jentzen W, Mueller SP, Debatin JF, et al. Whole-body positron emission tomography\u2013CT: optimized CT using oral and IV contrast materials. Am J Roentgenol 2002;179:1555\u201360","journal-title":"Am J Roentgenol"},{"key":"1784_CR12","doi-asserted-by":"crossref","first-page":"2046","DOI":"10.1118\/1.598392","volume":"25","author":"PE Kinahan","year":"1998","unstructured":"Kinahan PE, Townsend DW, Beyer T, Sashin D Attenuation correction for a combined PET\/CT scanner. Med Phys 1998;25:2046\u201353","journal-title":"Med Phys"},{"key":"1784_CR13","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1007\/s00259-002-0796-3","volume":"29","author":"C Burger","year":"2002","unstructured":"Burger C, Goerres G, Schoenes S, Buck A, Lonn AHR, Schultess GK. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging 2002;29:922\u201327","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1784_CR14","volume-title":"Positron emission tomography","author":"PE Valk","year":"2003","unstructured":"Valk PE, Bailey DL, Townsend DW, Maisey MN. Positron emission tomography. London: Springer; 2003"},{"key":"1784_CR15","first-page":"1339","volume":"43","author":"G Antoch","year":"2002","unstructured":"Antoch G, Freudenberg LS, Egelhof T, Stattaus J, Jentzen W, Debatin JF, et al. Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET\/CT scans. J Nucl Med 2002;43:1339\u201342","journal-title":"J Nucl Med"},{"key":"1784_CR16","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1148\/radiol.2273020299","volume":"227","author":"Y Nakamoto","year":"2003","unstructured":"Nakamoto Y, Chin BB, Kraitchman DL, Lawler LP, Marshall LT, Wahl RL. Effects of nonionic intravenous contrast agents at PET\/CT imaging: phantom and canine studies. Radiology 2003;227:817\u201324","journal-title":"Radiology"},{"key":"1784_CR17","doi-asserted-by":"crossref","unstructured":"Lonn AHR. Evaluation of method to minimize the effect of X-ray contrast in PET\u2013CT attenuation correction. 2003 IEEE Nuclear Science Symposium. Conference Record IEEE Cat. No. 03CH37515 2004 Vol 3. 2220\u20131","DOI":"10.1109\/NSSMIC.2003.1352321"},{"key":"1784_CR18","first-page":"404","volume-title":"Practical statistics for medical research","author":"DG Altman","year":"1999","unstructured":"Altman DG. Practical statistics for medical research. 1st ed. London: Chapman and Hall; 1999 p. 404\u20138","edition":"1"},{"key":"1784_CR19","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1007\/s00259-001-0698-9","volume":"29","author":"E Kamel","year":"2002","unstructured":"Kamel E, Hany TF, Burger C, Treyer V, Lonn AHR, von Schulthess GK, et al. CT vs 68Ge attenuation correction in a combined PET\/CT system: evaluation of the effect of lowering the CT tube current. Eur J Nucl Med Mol Imaging 2002;29:346\u201350","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1784_CR20","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1053\/snuc.2003.127312","volume":"33","author":"C Cohade","year":"2003","unstructured":"Cohade C, Wahl RL. Applications of positron emission tomography\/computed tomography image fusion in clinical positron emission tomography\u2014clinical use, interpretation methods, diagnostic improvements. Semin Nucl Med 2003;33:228\u201337","journal-title":"Semin Nucl Med"},{"key":"1784_CR21","first-page":"784","volume":"38","author":"G Antoch","year":"2003","unstructured":"Antoch G, Jentzen W, Freudenberg LS, Stattaus J, Mueller SP, Debatin JF, et al. Effect of oral contrast agents on computed tomography-based positron emission tomography attenuation correction in dual-modality positron emission tomography\/computed tomography imageing. Invest Radiol 2003;38:784\u20139","journal-title":"Invest Radiol"},{"key":"1784_CR22","first-page":"412","volume":"44","author":"C Cohade","year":"2003","unstructured":"Cohade C, Osman M, Nakamoto Y, Marshall LT, Links JM, Fishman EK, et al. Initial experience with oral contrast in PET\/CT: phantom and clinical studies. J Nucl Med 2003;44:412\u20136","journal-title":"J Nucl Med"},{"key":"1784_CR23","first-page":"1836","volume":"36","author":"JW Keyes","year":"1995","unstructured":"Keyes JW. SUV: standard uptake or silly useless value? J Nucl Med 1995;36:1836\u20139","journal-title":"J Nucl Med"}],"container-title":["European Journal of Nuclear Medicine and Molecular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00259-005-1784-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00259-005-1784-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00259-005-1784-1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T11:58:50Z","timestamp":1558699130000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00259-005-1784-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,5,21]]},"references-count":23,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["1784"],"URL":"https:\/\/doi.org\/10.1007\/s00259-005-1784-1","relation":{},"ISSN":["1619-7070","1619-7089"],"issn-type":[{"value":"1619-7070","type":"print"},{"value":"1619-7089","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,5,21]]}}}