{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T10:24:31Z","timestamp":1773829471333,"version":"3.50.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2009,9,24]],"date-time":"2009-09-24T00:00:00Z","timestamp":1253750400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Abdom Imaging"],"published-print":{"date-parts":[[2010,10]]},"DOI":"10.1007\/s00261-009-9568-x","type":"journal-article","created":{"date-parts":[[2009,9,23]],"date-time":"2009-09-23T13:22:40Z","timestamp":1253712160000},"page":"596-601","source":"Crossref","is-referenced-by-count":41,"title":["CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden"],"prefix":"10.1007","volume":"35","author":[{"given":"Emanuele","family":"Neri","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Faggioni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesca","family":"Cerri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesca","family":"Turini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Angeli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Cini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franco","family":"Perrone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio","family":"Paolicchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Bartolozzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,9,24]]},"reference":[{"issue":"1","key":"9568_CR1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.3322\/canjclin.55.1.10","volume":"55","author":"A Jemal","year":"2005","unstructured":"Jemal A, Murray T, Ward E, et al. (2005) Cancer statistics, 2005. CA Cancer J Clin 55(1):10\u201330","journal-title":"CA Cancer J Clin"},{"issue":"21","key":"9568_CR2","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1093\/jnci\/djn403","volume":"100","author":"NJ Nelson","year":"2008","unstructured":"Nelson NJ (2008) Virtual colonoscopy accepted as primary colon cancer screening test. J Natl Cancer Inst 100(21):1492\u20131499","journal-title":"J Natl Cancer Inst"},{"issue":"1","key":"9568_CR3","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1053\/j.gastro.2005.05.021","volume":"129","author":"DJ Brenner","year":"2005","unstructured":"Brenner DJ, Georgsson MA (2005) Mass screening with CT colonography: should the radiation exposure be of concern? Gastroenterology 129(1):328\u2013337","journal-title":"Gastroenterology"},{"key":"9568_CR4","unstructured":"International Commission on Radiological Protection (1991) 1990 recommendations of the international commission of radiological protection, publication no. 60. In: Smith H, (ed). Annals of the ICRP, vol 21. Oxford: Pergamon Press, pp 1\u20133"},{"key":"9568_CR5","unstructured":"Hospital Physicists\u2019 Association (Diagnostic Radiology Topic Group) (1977) The physics of radiodiagnostics: scientific report series, vol 6. London"},{"key":"9568_CR6","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1259\/bjr\/18915538","volume":"82","author":"Y Hirofuji","year":"2009","unstructured":"Hirofuji Y, Aoyama T, Koyama S, Kawaura C, Fujii K (2009) Evaluation of patient dose for barium enemas and CT colonography in Japan. Br J Radiol 82:219\u2013227","journal-title":"Br J Radiol"},{"key":"9568_CR7","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1259\/bjr.74.881.740420","volume":"74","author":"GJ Kemerink","year":"2001","unstructured":"Kemerink GJ, Borstlap ACW, Frantzen MJ, et al. (2001) Patient and occupational dosimetry in double contrast barium enema examinations. Br J Radiol 74:420\u2013428","journal-title":"Br J Radiol"},{"key":"9568_CR8","doi-asserted-by":"crossref","first-page":"695","DOI":"10.2214\/AJR.05.0662","volume":"187","author":"A Graser","year":"2006","unstructured":"Graser A, Wintersperger BJ, Suess C, Reiser MF, Becker CR (2006) Dose reduction and image quality in MDCT colonography using tube current modulation. AJR Am J Roentgenol 187:695\u2013701","journal-title":"AJR Am J Roentgenol"},{"key":"9568_CR9","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1148\/radiol.2242011382","volume":"224","author":"M Macari","year":"2002","unstructured":"Macari M, Bini EJ, Xue X, et al. (2002) Colorectal neoplasms: prospective comparison of thin-section low-dose multi-detector row CT colonography and conventional colonoscopy for detection. Radiology 224:383\u2013392","journal-title":"Radiology"},{"key":"9568_CR10","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1093\/rpd\/ncn159","volume":"129","author":"S Schopphoven","year":"2008","unstructured":"Schopphoven S, Faulkner K, Busch HP (2008) Assessment of patient organ dose in CT virtual colonoscopy for bowel cancer screening. Radiat Prot Dosimetry 129:179\u2013183","journal-title":"Radiat Prot Dosimetry"},{"key":"9568_CR11","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1007\/s00383-007-1982-y","volume":"23","author":"A Sugiyama","year":"2007","unstructured":"Sugiyama A, Ohashi Y, Gomi A, et al. (2007) Colorectal screening with single scan CT colonography in children. Pediatr Surg Int 23:987\u2013990","journal-title":"Pediatr Surg Int"},{"key":"9568_CR12","doi-asserted-by":"crossref","first-page":"2566","DOI":"10.1109\/TNS.2008.2004557","volume":"55","author":"J Wang","year":"2008","unstructured":"Wang J, Wang S, Li L, et al. (2008) Virtual colonoscopy screening with ultra low-dose CT and less-stressful bowel preparation: a computer simulation study. IEEE Trans Nucl Sci 55:2566\u20132675","journal-title":"IEEE Trans Nucl Sci"},{"key":"9568_CR13","first-page":"13","volume":"11","author":"M Branschofsky","year":"2006","unstructured":"Branschofsky M, Vogt C, Aurich V, et al. (2006) Feasibility of ultra-low-dose multi-detector-row CT-colonography: detection of artificial endoluminal lesions in an in vitro-model with optimization of image quality using a noise reduction filter algorithm. Eur J Med Res 11:13\u201319","journal-title":"Eur J Med Res"},{"key":"9568_CR14","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1148\/radiol.2291020561","volume":"229","author":"SA Taylor","year":"2003","unstructured":"Taylor SA, Halligan S, Bartram CI, et al. (2003) Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen. Radiology 229:109\u2013118","journal-title":"Radiology"},{"key":"9568_CR15","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1007\/s00330-002-1671-0","volume":"13","author":"A Laghi","year":"2003","unstructured":"Laghi A, Iannaccone R, Mangiapane F, et al. (2003) Experimental colonic phantom for the evaluation of the optimal scanning technique for CT colonography using a multidetector spiral CT equipment. Eur Radiol 13:459\u2013466","journal-title":"Eur Radiol"},{"key":"9568_CR16","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/s00261-001-0166-9","volume":"27","author":"CH McCollough","year":"2002","unstructured":"McCollough CH (2002) Optimization of multidetector array CT acquisition parameters for CT colonography. Abdom Imaging 27:253\u2013259","journal-title":"Abdom Imaging"},{"key":"9568_CR17","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1148\/rg.271065037","volume":"27","author":"NC Dalrymple","year":"2007","unstructured":"Dalrymple NC, Prasad SR, El-Merhi FM, Chintapalli KN (2007) Price of isotropy in multidetector CT. Radiographics 27:49\u201362","journal-title":"Radiographics"},{"key":"9568_CR18","doi-asserted-by":"crossref","first-page":"2616","DOI":"10.1007\/s00330-007-0601-6","volume":"17","author":"O Luz","year":"2007","unstructured":"Luz O, Buchgeister M, Klabunde M, et al. (2007) Evaluation of dose exposure in 64-slice CT colonography. Eur Radiol 17:2616\u20132621","journal-title":"Eur Radiol"},{"key":"9568_CR19","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1007\/s00330-005-0047-7","volume":"16","author":"S Jensch","year":"2006","unstructured":"Jensch S, van Gelder RE, Venema HW, et al. (2006) Effective radiation doses in CT colonography: results of an inventory among research institutions. Eur Radiol 16:981\u2013987","journal-title":"Eur Radiol"},{"key":"9568_CR20","doi-asserted-by":"crossref","first-page":"2222","DOI":"10.1007\/s00330-008-0994-x","volume":"18","author":"MH Liedenbaum","year":"2008","unstructured":"Liedenbaum MH, Venema HW, Stoker J (2008) Radiation dose in CT colonography\u2014trends in time and differences between daily practice and screening protocols. Eur Radiol 18:2222\u20132230","journal-title":"Eur Radiol"},{"key":"9568_CR21","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1148\/radiology.204.2.9240552","volume":"204","author":"J Geleijns","year":"1997","unstructured":"Geleijns J, Broerse JJ, Shaw MP, et al. (1997) Patient dose due to colon examination: dose assessment and results from a survey in the Netherlands. Radiology 204:553\u2013559","journal-title":"Radiology"},{"key":"9568_CR22","doi-asserted-by":"crossref","unstructured":"Yanch JC, Behrman RH, Hendricks MJ, McCall JH. Increased radiation dose to overweight and obese patients from radiographic examinations. Radiology 2009. doi: 10.1148\/radiol.2521080141","DOI":"10.1148\/radiol.2521080141"}],"container-title":["Abdominal Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-009-9568-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00261-009-9568-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-009-9568-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T11:30:41Z","timestamp":1590147041000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00261-009-9568-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9,24]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2010,10]]}},"alternative-id":["9568"],"URL":"https:\/\/doi.org\/10.1007\/s00261-009-9568-x","relation":{},"ISSN":["0942-8925","1432-0509"],"issn-type":[{"value":"0942-8925","type":"print"},{"value":"1432-0509","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9,24]]}}}