{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T21:08:24Z","timestamp":1783976904587,"version":"3.55.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2019,1,18]],"date-time":"2019-01-18T00:00:00Z","timestamp":1547769600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"published-print":{"date-parts":[[2019,5]]},"DOI":"10.1007\/s00261-018-01886-0","type":"journal-article","created":{"date-parts":[[2019,1,18]],"date-time":"2019-01-18T13:25:36Z","timestamp":1547817936000},"page":"1766-1772","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique"],"prefix":"10.1007","volume":"44","author":[{"given":"Shoma","family":"Nagata","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Goshima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshifumi","family":"Noda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Kawai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimihiro","family":"Kajita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kawada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukichi","family":"Tanahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masayuki","family":"Matsuo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,1,18]]},"reference":[{"issue":"2","key":"1886_CR1","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1002\/jmri.24155","volume":"39","author":"JH Lee","year":"2014","unstructured":"Lee JH, Lee SS, Kim JY, Kim IS, Byun JH, Park SH, Lee MG (2014) Parallel imaging improves the image quality and duct visibility of breathhold two-dimensional thick-slab MR cholangiopancreatography. J Magn Reson Imaging 39 (2):269-275. \n                    https:\/\/doi.org\/10.1002\/jmri.24155","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"1886_CR2","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1148\/radiol.2382032065","volume":"238","author":"A Sodickson","year":"2006","unstructured":"Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CMC (2006) Three-dimensional Fast-Recovery Fast Spin-Echo MRCP: Comparison with Two-dimensional Single-Shot Fast Spin-Echo Techniques. Radiology 238 (2):549-559. \n                    https:\/\/doi.org\/10.1148\/radiol.2382032065","journal-title":"Radiology"},{"issue":"5","key":"1886_CR3","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1002\/jmri.25672","volume":"46","author":"N Seo","year":"2017","unstructured":"Seo N, Park MS, Han K, Kim D, King KF, Choi JY, Kim H, Kim HJ, Lee M, Bae H, Kim MJ (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T. J Magn Reson Imaging 46 (5):1289-1297. \n                    https:\/\/doi.org\/10.1002\/jmri.25672","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"1886_CR4","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: The application of compressed sensing for rapid MR imaging. Magnetic resonance in medicine 58 (6):1182-1195. \n                    https:\/\/doi.org\/10.1002\/mrm.21391","journal-title":"Magnetic resonance in medicine"},{"issue":"10","key":"1886_CR5","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1097\/RLI.0000000000000380","volume":"52","author":"JH Yoon","year":"2017","unstructured":"Yoon JH, Lee SM, Kang HJ, Weiland E, Raithel E, Son Y, Kiefer B, Lee JM (2017) Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing: Comparison of Image Quality and Diagnostic Performance. Investigative radiology 52 (10):612-619. \n                    https:\/\/doi.org\/10.1097\/rli.0000000000000380","journal-title":"Investigative radiology"},{"issue":"3","key":"1886_CR6","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1097\/RLI.0000000000000421","volume":"53","author":"L Zhu","year":"2018","unstructured":"Zhu L, Wu X, Sun Z, Jin Z, Weiland E, Raithel E, Qian T, Xue H (2018) Compressed-Sensing Accelerated 3-Dimensional Magnetic Resonance Cholangiopancreatography: Application in Suspected Pancreatic Diseases. Investigative radiology 53 (3):150-157. \n                    https:\/\/doi.org\/10.1097\/rli.0000000000000421","journal-title":"Investigative radiology"},{"key":"1886_CR7","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.mri.2018.11.004","volume":"57","author":"N Kawai","year":"2018","unstructured":"Kawai N, Goshima S, Noda Y, Kajita K, Kawada H, Tanahashi Y, Nagata S, Matsuo M (2018) Gadoxetic acid-enhanced dynamic magnetic resonance imaging using optimized integrated combination of compressed sensing and parallel imaging technique. Magn Reson Imaging 57:111-117. \n                    https:\/\/doi.org\/10.1016\/j.mri.2018.11.004","journal-title":"Magn Reson Imaging"},{"issue":"6","key":"1886_CR8","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1002\/mrm.20713","volume":"54","author":"P Kellman","year":"2005","unstructured":"Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: a general method for SNR measurement. Magnetic resonance in medicine 54 (6):1439-1447. \n                    https:\/\/doi.org\/10.1002\/mrm.20713","journal-title":"Magnetic resonance in medicine"},{"issue":"4","key":"1886_CR9","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1002\/mrm.21728","volume":"60","author":"PM Robson","year":"2008","unstructured":"Robson PM, Grant AK, Madhuranthakam AJ, Lattanzi R, Sodickson DK, McKenzie CA (2008) Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions. Magnetic resonance in medicine 60 (4):895-907. \n                    https:\/\/doi.org\/10.1002\/mrm.21728","journal-title":"Magnetic resonance in medicine"},{"issue":"2","key":"1886_CR10","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1002\/jmri.20969","volume":"26","author":"O Dietrich","year":"2007","unstructured":"Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26 (2):375-385. \n                    https:\/\/doi.org\/10.1002\/jmri.20969","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"1886_CR11","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1007\/s11604-005-1528-y","volume":"24","author":"T Masui","year":"2006","unstructured":"Masui T, Katayama M, Kobayashi S, Nozaki A, Sugimura M, Ikeda M, Sakahara H (2006) Magnetic resonance cholangiopancreatography: comparison of respiratory-triggered three-dimensional fast-recovery fast spin-echo with parallel imaging technique and breath-hold half-Fourier two-dimensional single-shot fast spin-echo technique. Radiation medicine 24 (3):202-209","journal-title":"Radiation medicine"},{"issue":"6","key":"1886_CR12","doi-asserted-by":"publisher","first-page":"1564","DOI":"10.2214\/AJR.05.1032","volume":"187","author":"J Zhang","year":"2006","unstructured":"Zhang J, Israel GM, Hecht EM, Krinsky GA, Babb JS, Lee VS (2006) Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study. AJR American journal of roentgenology 187 (6):1564-1570. \n                    https:\/\/doi.org\/10.2214\/AJR.05.1032","journal-title":"AJR American journal of roentgenology"},{"issue":"2","key":"1886_CR13","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1148\/radiol.2016151935","volume":"280","author":"H Chandarana","year":"2016","unstructured":"Chandarana H, Doshi AM, Shanbhogue A, Babb JS, Bruno MT, Zhao T, Raithel E, Zenge MO, Li G, Otazo R (2016) Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data. Radiology 280 (2):585-594. \n                    https:\/\/doi.org\/10.1148\/radiol.2016151935","journal-title":"Radiology"},{"key":"1886_CR14","doi-asserted-by":"publisher","unstructured":"Zhu L, Xue H, Sun Z, Qian T, Weiland E, Kuehn B, Asbach P, Hamm B, Jin Z (2018) Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: Clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging. \n                    https:\/\/doi.org\/10.1002\/jmri.26049","DOI":"10.1002\/jmri.26049"},{"key":"1886_CR15","doi-asserted-by":"publisher","unstructured":"Kwon H, Reid S, Kim D, Lee S, Cho J, Oh J (2018) Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing. Abdominal radiology (New York). \n                    https:\/\/doi.org\/10.1007\/s00261-017-1451-6","DOI":"10.1007\/s00261-017-1451-6"},{"issue":"1","key":"1886_CR16","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1002\/jmri.23750","volume":"37","author":"PW Worters","year":"2013","unstructured":"Worters PW, Sung K, Stevens KJ, Koch KM, Hargreaves BA (2013) Compressed-sensing multispectral imaging of the postoperative spine. J Magn Reson Imaging 37 (1):243-248. \n                    https:\/\/doi.org\/10.1002\/jmri.23750","journal-title":"J Magn Reson Imaging"}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00261-018-01886-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-018-01886-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-018-01886-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,1,18]],"date-time":"2020-01-18T00:22:13Z","timestamp":1579306933000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00261-018-01886-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,18]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["1886"],"URL":"https:\/\/doi.org\/10.1007\/s00261-018-01886-0","relation":{},"ISSN":["2366-004X","2366-0058"],"issn-type":[{"value":"2366-004X","type":"print"},{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1,18]]},"assertion":[{"value":"18 January 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Author disclosure of potential conflict of interest. No relevant conflicts of interest to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Research involving human participants and\/or animals"}},{"value":"The requirement for informed consent was waived by our Institutional Review Board.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}