{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T02:20:51Z","timestamp":1790821251658,"version":"4.1.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2019,2,22]],"date-time":"2019-02-22T00:00:00Z","timestamp":1550793600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"published-print":{"date-parts":[[2019,5]]},"DOI":"10.1007\/s00261-019-01932-5","type":"journal-article","created":{"date-parts":[[2019,2,22]],"date-time":"2019-02-22T10:55:39Z","timestamp":1550832939000},"page":"1825-1833","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements"],"prefix":"10.1007","volume":"44","author":[{"given":"Chenyang","family":"Zhan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Kannengiesser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hersh","family":"Chandarana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Fenchel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin","family":"Ream","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krishna Prasad","family":"Shanbhogue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,22]]},"reference":[{"issue":"6","key":"1932_CR1","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1002\/hep.20466","volume":"40","author":"JD Browning","year":"2004","unstructured":"Browning, J.D., L.S. Szczepaniak, R. Dobbins, P. Nuremberg, J.D. Horton, et al. (2004) Prevalence of hepatic steatosis in an urban population in the United States: impact of ethnicity. Hepatology, 40(6): p. 1387-95.","journal-title":"Hepatology"},{"key":"1932_CR2","doi-asserted-by":"crossref","unstructured":"Younossi, Z.M., M. Stepanova, M. Afendy, Y. Fang, Y. Younossi, et al. (2011) Changes in the prevalence of the most common causes of chronic liver diseases in the United States from 1988 to 2008. Clin Gastroenterol Hepatol, 9(6): p. 524-530 e1; quiz e60.","DOI":"10.1016\/j.cgh.2011.03.020"},{"issue":"2","key":"1932_CR3","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1002\/hep.23315","volume":"51","author":"JE Everhart","year":"2010","unstructured":"Everhart, J.E., E.C. Wright, Z.D. Goodman, J.L. Dienstag, J.C. Hoefs, et al. (2010) Prognostic value of Ishak fibrosis stage: findings from the hepatitis C antiviral long-term treatment against cirrhosis trial. Hepatology, 51(2): p. 585-94.","journal-title":"Hepatology"},{"key":"1932_CR4","doi-asserted-by":"crossref","unstructured":"Garcia-Tsao, G., A.J. Sanyal, N.D. Grace, W. Carey, D. Practice Guidelines Committee of the American Association for the Study of Liver, et al. (2007) Prevention and management of gastroesophageal varices and variceal hemorrhage in cirrhosis. Hepatology, 46(3): p. 922-38.","DOI":"10.1002\/hep.21907"},{"issue":"3","key":"1932_CR5","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1002\/hep.24199","volume":"53","author":"Bruix, J., M. Sherman, and D. American Association for the Study of Liver","year":"2011","unstructured":"Bruix, J., M. Sherman, and D. American Association for the Study of Liver (2011) Management of hepatocellular carcinoma: an update. Hepatology, 53(3): p. 1020-2.","journal-title":"Hepatology"},{"issue":"7","key":"1932_CR6","doi-asserted-by":"publisher","first-page":"1898","DOI":"10.1053\/j.gastro.2005.03.084","volume":"128","author":"V Ratziu","year":"2005","unstructured":"Ratziu, V., F. Charlotte, A. Heurtier, S. Gombert, P. Giral, et al. (2005) Sampling variability of liver biopsy in nonalcoholic fatty liver disease. Gastroenterology, 128(7): p. 1898-906.","journal-title":"Gastroenterology"},{"issue":"3","key":"1932_CR7","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/j.crad.2011.08.022","volume":"67","author":"L Mannelli","year":"2012","unstructured":"Mannelli, L., E. Godfrey, M.J. Graves, A.J. Patterson, P. Beddy, et al. (2012) Magnetic resonance elastography: feasibility of liver stiffness measurements in healthy volunteers at 3T. Clin Radiol, 67(3): p. 258-62.","journal-title":"Clin Radiol"},{"issue":"5232","key":"1932_CR8","doi-asserted-by":"publisher","first-page":"1854","DOI":"10.1126\/science.7569924","volume":"269","author":"R Muthupillai","year":"1995","unstructured":"Muthupillai, R., D.J. Lomas, P.J. Rossman, J.F. Greenleaf, A. Manduca, et al. (1995) Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science, 269(5232): p. 1854-7.","journal-title":"Science"},{"key":"1932_CR9","doi-asserted-by":"crossref","unstructured":"Yin, M., J.A. Talwalkar, K.J. Glaser, A. Manduca, R.C. Grimm, et al. (2007) Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterol Hepatol, 5(10): p. 1207-1213 e2.","DOI":"10.1016\/j.cgh.2007.06.012"},{"issue":"5","key":"1932_CR10","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.jhep.2016.06.005","volume":"65","author":"PS Dulai","year":"2016","unstructured":"Dulai, P.S., C.B. Sirlin, and R. Loomba (2016) MRI and MRE for non-invasive quantitative assessment of hepatic steatosis and fibrosis in NAFLD and NASH: Clinical trials to clinical practice. J Hepatol, 65(5): p. 1006-1016.","journal-title":"J Hepatol"},{"issue":"4","key":"1932_CR11","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1002\/hep.27647","volume":"61","author":"R Loomba","year":"2015","unstructured":"Loomba, R., C.B. Sirlin, B. Ang, R. Bettencourt, R. Jain, et al. (2015) Ezetimibe for the treatment of nonalcoholic steatohepatitis: assessment by novel magnetic resonance imaging and magnetic resonance elastography in a randomized trial (MOZART trial). Hepatology, 61(4): p. 1239-50.","journal-title":"Hepatology"},{"issue":"3","key":"1932_CR12","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1148\/radiol.11101942","volume":"259","author":"J Chen","year":"2011","unstructured":"Chen, J., J.A. Talwalkar, M. Yin, K.J. Glaser, S.O. Sanderson, et al. (2011) Early detection of nonalcoholic steatohepatitis in patients with nonalcoholic fatty liver disease by using MR elastography. Radiology, 259(3): p. 749-56.","journal-title":"Radiology"},{"issue":"3","key":"1932_CR13","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1148\/radiol.2018172099","volume":"287","author":"AT Trout","year":"2018","unstructured":"Trout, A.T., R.M. Sheridan, S.D. Serai, S.A. Xanthakos, W. Su, et al. (2018) Diagnostic Performance of MR Elastography for Liver Fibrosis in Children and Young Adults with a Spectrum of Liver Diseases. Radiology, 287(3): p. 824-832.","journal-title":"Radiology"},{"issue":"1","key":"1932_CR14","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1148\/radiol.2015142141","volume":"278","author":"M Yin","year":"2016","unstructured":"Yin, M., K.J. Glaser, J.A. Talwalkar, J. Chen, A. Manduca, et al. (2016) Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations. Radiology, 278(1): p. 114-24.","journal-title":"Radiology"},{"issue":"3","key":"1932_CR15","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1148\/radiol.2016160589","volume":"282","author":"SD Serai","year":"2017","unstructured":"Serai, S.D., J.R. Dillman, and A.T. Trout (2017) Spin-echo Echo-planar Imaging MR Elastography versus Gradient-echo MR Elastography for Assessment of Liver Stiffness in Children and Young Adults Suspected of Having Liver Disease. Radiology, 282(3): p. 761-770.","journal-title":"Radiology"},{"key":"1932_CR16","doi-asserted-by":"crossref","unstructured":"Felker, E.R., K.S. Choi, K. Sung, H.H. Wu, S.S. Raman, et al. (2018) Liver MR Elastography at 3 T: Agreement Across Pulse Sequences and Effect of Liver R2* on Image Quality. AJR Am J Roentgenol: p. 1-7.","DOI":"10.2214\/AJR.17.19288"},{"issue":"2","key":"1932_CR17","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1148\/radiol.2016160153","volume":"282","author":"YK Mariappan","year":"2017","unstructured":"Mariappan, Y.K., B. Dzyubak, K.J. Glaser, S.K. Venkatesh, C.B. Sirlin, et al. (2017) Application of Modified Spin-Echo-based Sequences for Hepatic MR Elastography: Evaluation, Comparison with the Conventional Gradient-Echo Sequence, and Preliminary Clinical Experience. Radiology, 282(2): p. 390-398.","journal-title":"Radiology"},{"issue":"10","key":"1932_CR18","doi-asserted-by":"publisher","first-page":"4120","DOI":"10.1007\/s00330-017-4781-4","volume":"27","author":"YS Kim","year":"2017","unstructured":"Kim, Y.S., J.S. Song, S. Kannengiesser, and S.Y. Seo (2017) Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration. Eur Radiol, 27(10): p. 4120-4128.","journal-title":"Eur Radiol"},{"issue":"2","key":"1932_CR19","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1002\/jmri.24147","volume":"39","author":"Y Lee","year":"2014","unstructured":"Lee, Y., J.M. Lee, J.E. Lee, K.B. Lee, E.S. Lee, et al. (2014) MR elastography for noninvasive assessment of hepatic fibrosis: reproducibility of the examination and reproducibility and repeatability of the liver stiffness value measurement. J Magn Reson Imaging, 39(2): p. 326-31.","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"1932_CR20","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1007\/s00261-017-1045-3","volume":"42","author":"M Toguchi","year":"2017","unstructured":"Toguchi, M., M. Tsurusaki, N. Yada, K. Sofue, T. Hyodo, et al. (2017) Magnetic resonance elastography in the assessment of hepatic fibrosis: a study comparing transient elastography and histological data in the same patients. Abdom Radiol (NY), 42(6): p. 1659-1666.","journal-title":"Abdom Radiol (NY)"},{"issue":"1","key":"1932_CR21","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.jhep.2013.09.002","volume":"60","author":"R Banerjee","year":"2014","unstructured":"Banerjee, R., M. Pavlides, E.M. Tunnicliffe, S.K. Piechnik, N. Sarania, et al. (2014) Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease. J Hepatol, 60(1): p. 69-77.","journal-title":"J Hepatol"},{"issue":"2","key":"1932_CR22","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1148\/radiol.2016160863","volume":"284","author":"M Wagner","year":"2017","unstructured":"Wagner, M., I. Corcuera-Solano, G. Lo, S. Esses, J. Liao, et al. (2017) Technical Failure of MR Elastography Examinations of the Liver: Experience from a Large Single-Center Study. Radiology, 284(2): p. 401-412.","journal-title":"Radiology"},{"issue":"10","key":"1932_CR23","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1002\/nbm.2958","volume":"26","author":"P Garteiser","year":"2013","unstructured":"Garteiser, P., R.S. Sahebjavaher, L.C. Ter Beek, S. Salcudean, V. Vilgrain, et al. (2013) Rapid acquisition of multifrequency, multislice and multidirectional MR elastography data with a fractionally encoded gradient echo sequence. NMR Biomed, 26(10): p. 1326-35.","journal-title":"NMR Biomed"},{"issue":"10","key":"1932_CR24","doi-asserted-by":"publisher","first-page":"e3919","DOI":"10.1002\/nbm.3919","volume":"31","author":"C Guenthner","year":"2018","unstructured":"Guenthner, C. and S. Kozerke (2018) Encoding and readout strategies in magnetic resonance elastography. NMR Biomed, 31(10): p. e3919.","journal-title":"NMR Biomed"},{"issue":"4","key":"1932_CR25","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1007\/s00261-015-0373-4","volume":"40","author":"M Dhyani","year":"2015","unstructured":"Dhyani, M., A. Anvari, and A.E. Samir (2015) Ultrasound elastography: liver. Abdom Imaging, 40(4): p. 698-708.","journal-title":"Abdom Imaging"},{"issue":"4","key":"1932_CR26","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1002\/mrm.22785","volume":"65","author":"S Chung","year":"2011","unstructured":"Chung, S., E. Breton, L. Mannelli, and L. Axel (2011) Liver stiffness assessment by tagged MRI of cardiac-induced liver motion. Magn Reson Med, 65(4): p. 949-55.","journal-title":"Magn Reson Med"},{"issue":"6","key":"1932_CR27","doi-asserted-by":"publisher","first-page":"1490","DOI":"10.1002\/jmri.23743","volume":"36","author":"L Mannelli","year":"2012","unstructured":"Mannelli, L., G.J. Wilson, T.J. Dubinsky, C.A. Potter, P. Bhargava, et al. (2012) Assessment of the liver strain among cirrhotic and normal livers using tagged MRI. J Magn Reson Imaging, 36(6): p. 1490-5.","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"1932_CR28","doi-asserted-by":"publisher","first-page":"291","DOI":"10.2463\/mrms.11.291","volume":"11","author":"S Ichikawa","year":"2012","unstructured":"Ichikawa, S., U. Motosugi, T. Ichikawa, K. Sano, H. Morisaka, et al. (2012) Magnetic resonance elastography for staging liver fibrosis in chronic hepatitis C. Magn Reson Med Sci, 11(4): p. 291-7.","journal-title":"Magn Reson Med Sci"},{"issue":"7","key":"1932_CR29","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1056\/NEJM200102153440706","volume":"344","author":"AA Bravo","year":"2001","unstructured":", A.A., S.G. Sheth, and S. Chopra (2001) Liver biopsy. N Engl J Med, 344(7): p. 495-500.","journal-title":"N Engl J Med"},{"issue":"10","key":"1932_CR30","doi-asserted-by":"publisher","first-page":"2614","DOI":"10.1111\/j.1572-0241.2002.06038.x","volume":"97","author":"A Regev","year":"2002","unstructured":"Regev, A., M. Berho, L.J. Jeffers, C. Milikowski, E.G. Molina, et al. (2002) Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection. Am J Gastroenterol, 97(10): p. 2614-8.","journal-title":"Am J Gastroenterol"},{"issue":"2","key":"1932_CR31","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/s00261-013-0063-z","volume":"39","author":"JH Runge","year":"2014","unstructured":"Runge, J.H., A.E. Bohte, J. Verheij, V. Terpstra, A.J. Nederveen, et al. (2014) Comparison of interobserver agreement of magnetic resonance elastography with histopathological staging of liver fibrosis. Abdom Imaging, 39(2): p. 283-90.","journal-title":"Abdom Imaging"}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00261-019-01932-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-019-01932-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-019-01932-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,22]],"date-time":"2020-02-22T00:26:45Z","timestamp":1582331205000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00261-019-01932-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,22]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["1932"],"URL":"https:\/\/doi.org\/10.1007\/s00261-019-01932-5","relation":{},"ISSN":["2366-004X","2366-0058"],"issn-type":[{"value":"2366-004X","type":"print"},{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,22]]},"assertion":[{"value":"22 February 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Stephan Kannengiesser and Matthias Fenchel are the Employee of Siemens Healthineers. All other author declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study is IRB-approved and HIPAA-compliant.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}