{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T19:55:49Z","timestamp":1789415749157,"version":"build-2803163510"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,8,9]],"date-time":"2020-08-09T00:00:00Z","timestamp":1596931200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,9]],"date-time":"2020-08-09T00:00:00Z","timestamp":1596931200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1007\/s00261-020-02652-x","type":"journal-article","created":{"date-parts":[[2020,8,9]],"date-time":"2020-08-09T08:05:26Z","timestamp":1596960326000},"page":"590-596","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Technical success rate of MR elastography in a population without known liver disease"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9142-894X","authenticated-orcid":false,"given":"Howard E.","family":"Gill","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Lisanti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan B.","family":"Schwope","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Katz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Harrison","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,9]]},"reference":[{"issue":"3","key":"2652_CR1","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.cgh.2014.09.046","volume":"13","author":"S Singh","year":"2015","unstructured":"Singh S, Venkatesh SK, Wang Z, et al (2015) Diagnostic performance of magnetic resonance elastography in staging liver fibrosis: a systematic review and meta-analysis of individual participant data. Clin Gastroentero Hepatol 13(3):440-451.","journal-title":"Clin Gastroentero Hepatol"},{"issue":"5","key":"2652_CR2","first-page":"778","volume":"15","author":"KP McGee","year":"2018","unstructured":"McGee KP (2018) Virtual Palpation: The Role of MR Elastography in Quantifying and Spatially Resolving Tissue Stiffness as a Biomarker of Disease. JACR 15(5):778-780","journal-title":"JACR"},{"issue":"1","key":"2652_CR3","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1002\/hep.29367","volume":"67","author":"N Chalasani","year":"2018","unstructured":"Chalasani N, Younossi Z, Lavine JE, et al. 2018 The diagnosis and management of nonalcoholic fatty liver disease: practice guidance from the American Association for the Study of Liver Diseases. Hepatology 67(1):328-357.","journal-title":"Hepatology"},{"issue":"1","key":"2652_CR4","first-page":"307","volume":"51","author":"RS O\u2019Shea","year":"2010","unstructured":"O'Shea RS, Dasarathy S, McCullough AJ 2010 Practice Guideline Committee of the American Association for the Study of Liver Diseases and the Practice Parameters Committee of the American College of Gastroenterology. Alcoholic liver disease. Hepatology 51(1):307-328.","journal-title":"Alcoholic liver disease. Hepatology"},{"issue":"1","key":"2652_CR5","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1148\/radiol.2015142141","volume":"278","author":"M Yin","year":"2010","unstructured":"Yin M, Glaser KJ, Talwalkar JA, et al 2010 Hepatic MR elastography: clinical performance in a series of 1377 consecutive examinations. Radiology 278(1):114-124.","journal-title":"Radiology"},{"issue":"3","key":"2652_CR6","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1002\/jmri.22066","volume":"31","author":"CD Hines","year":"2010","unstructured":"Hines CD, Bley TA, Lindstrom MJ, Reeder SB 2010 Repeatability of magnetic resonance elastography for quantification of hepatic stiffness. JMRI 31(3):725-731.","journal-title":"JMRI"},{"issue":"3","key":"2652_CR7","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1148\/radiol.2015150619","volume":"276","author":"RG Barr","year":"2015","unstructured":"Barr RG, Ferraioli G, Palmeri ML, et al 2015 Elastography assessment of liver fibrosis: society of radiologists in ultrasound consensus conference statement. Radiology 276(3):845-861.","journal-title":"Radiology"},{"issue":"3","key":"2652_CR8","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1148\/radiol.11101942","volume":"259","author":"J Chen","year":"2011","unstructured":"Chen J, Talwalkar JA, Yin M, Glaser KJ, Sanderson SO, Ehman RL 2011 Early detection of nonalcoholic steatohepatitis in patients with nonalcoholic fatty liver disease by using MR elastography. Radiology 259(3):749-756.","journal-title":"Radiology"},{"key":"2652_CR9","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.matbio.2018.04.006","volume":"68","author":"D Schuppan","year":"2018","unstructured":"Schuppan D, Ashfaq-Khan M, Yang AT, Kim YO 2018 Liver fibrosis: Direct antifibrotic agents and targeted therapies. Matrix Biology 68:435-451.","journal-title":"Matrix Biology"},{"issue":"7","key":"2652_CR10","doi-asserted-by":"publisher","first-page":"1987","DOI":"10.1148\/rg.2016160042","volume":"36","author":"A Srinivasa Babu","year":"2016","unstructured":"Srinivasa Babu A, Wells ML, Teytelboym OM, et al. (2016) Elastography in chronic liver disease: modalities, techniques, limitations, and future directions. Radiographics 36(7):1987\u20132006","journal-title":"Radiographics"},{"issue":"1","key":"2652_CR11","doi-asserted-by":"publisher","first-page":"22","DOI":"10.2214\/AJR.15.14552","volume":"205","author":"A Tang","year":"2015","unstructured":"Tang A, Cloutier G, Szeverenyi NM, Sirlin CB 2015 Ultrasound elastography and MR elastography for assessing liver fibrosis: part 1, principles and techniques. AJR 205(1):22-32.","journal-title":"AJR"},{"issue":"2","key":"2652_CR12","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1148\/radiol.2016160153","volume":"282","author":"YK Mariappan","year":"2016","unstructured":"Mariappan YK, Dzyubak B, Glaser KJ, et al 2016 Application of modified spin-echo\u2013based sequences for hepatic MR elastography: evaluation, comparison with the conventional gradient-echo sequence, and preliminary clinical experience. Radiology 282(2):390-398.","journal-title":"Radiology"},{"issue":"2","key":"2652_CR13","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1148\/radiol.2016160863","volume":"284","author":"M Wagner","year":"2017","unstructured":"Wagner M, Corcuera-Solano I, Lo G, et al 2017 Technical failure of MR elastography examinations of the liver: experience from a large single-center study. Radiology 284(2):401-412.","journal-title":"Radiology"},{"issue":"2","key":"2652_CR14","first-page":"119","volume":"52","author":"A Agresti","year":"1998","unstructured":"Agresti A, Coull BA 1998 Approximate is better than \u201cexact\u201d for interval estimation of binomial proportions. The American Statistician 52(2):119-126.","journal-title":"The American Statistician"},{"issue":"3","key":"2652_CR15","doi-asserted-by":"publisher","first-page":"588","DOI":"10.2214\/AJR.17.19288","volume":"211","author":"ER Felker","year":"2018","unstructured":"Felker ER, Choi KS, Sung K, et al 2018 Liver MR Elastography at 3 T: Agreement Across Pulse Sequences and Effect of Liver R2* on Image Quality. AJR 211(3):588-594.","journal-title":"AJR"},{"issue":"3","key":"2652_CR16","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1148\/radiol.2016160589","volume":"282","author":"SD Serai","year":"2016","unstructured":"Serai SD, Dillman JR, Trout AT 2016 Spin-echo echo-planar imaging MR elastography versus gradient-echo MR elastography for assessment of liver stiffness in children and young adults suspected of having liver disease. Radiology 282(3):761-770.","journal-title":"Radiology"}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-020-02652-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00261-020-02652-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-020-02652-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,8]],"date-time":"2021-08-08T23:16:17Z","timestamp":1628464577000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00261-020-02652-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,9]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["2652"],"URL":"https:\/\/doi.org\/10.1007\/s00261-020-02652-x","relation":{},"ISSN":["2366-004X","2366-0058"],"issn-type":[{"value":"2366-004X","type":"print"},{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,9]]},"assertion":[{"value":"13 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Dr. Lisanti receives royalties from Lippincott William-Wilkins for the book MRI: The Basics. Dr. Harrison has received consulting fees from Akero, Altimmune, Axcella, Blade Therapeutics, Cirius, CiVi Biopharma, Hepion, Cymabay, Echosens, Foresite Labs, Galectin, Galmed, Gelesis, Genfit, Gilead Sciences, Hightide, HistoIndex, Indalo, Innovate, Intercept, Madrigal, Medpace, Metacrine, NGM Bio, NorthSea, Novartis, Novo Nordisk, Perspectum, Poxel, Prometheus, Prometic,Terns, Viking, and Sagimet; has received funds for research support from Axcella, BMS, Cirius, Conatus, Hepion, Cymabay, Enyo, Galectin, Galmed, Genfit, Gilead Sciences, Hightide, Immuron, Intercept, Madrigal, Metacrine, NGM Bio, NorthSea, Novartis, Novo Nordisk, Pfizer, Second Genome, Tobira\/Allergan, and Sagimet; and has been granted stock ownership or equity in Akero, Galectin, Genfit, Histoindex, Madrigal, Metacrine, NGM, and NorthSea. Drs. Gill, Schwope, Kim, and Katz have no disclosures. The view(s) expressed herein are those of the author(s) and do not reflect the official policy or position of Brooke Army Medical Center, the U.S. Army Medical Department, the U.S. Army Office of the Surgeon General, the Department of the Army, and Department of Defense or the U.S. Government.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}