{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T17:37:35Z","timestamp":1773509855694,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,8,2]],"date-time":"2020-08-02T00:00:00Z","timestamp":1596326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,2]],"date-time":"2020-08-02T00:00:00Z","timestamp":1596326400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1007\/s00261-020-02686-1","type":"journal-article","created":{"date-parts":[[2020,8,2]],"date-time":"2020-08-02T10:02:35Z","timestamp":1596362555000},"page":"562-569","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Biliary excretion of gadobenate dimeglumine causing degradation of magnetic resonance cholangiopancreatography (MRCP)"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8574-3775","authenticated-orcid":false,"given":"Lukas M.","family":"Trunz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Flavius F.","family":"Guglielmo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santosh K.","family":"Selvarajan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haresh V.","family":"Naringrekar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdullah","family":"Alturki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaydev K.","family":"Dave","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donald G.","family":"Mitchell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,2]]},"reference":[{"issue":"1","key":"2686_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.13189\/ujmsj.2016.040101","volume":"4","author":"A Patel","year":"2016","unstructured":"Patel A, Silverberg C, Becker-Weidman D, Roth C, Deshmukh S (2016) Understanding Body MRI Sequences and Their Ability to Characterize Tissues. Universal Journal of Medical Science 4(1): 1-9","journal-title":"Universal Journal of Medical Science"},{"issue":"4","key":"2686_CR2","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/j.mric.2017.06.011","volume":"25","author":"F Czeyda-Pommersheim","year":"2017","unstructured":"Czeyda-Pommersheim F, Martin DR, Costello JR, Kalb B (2017) Contrast Agents for MR Imaging. Magnetic resonance imaging clinics of North America 25(4): 705-711","journal-title":"Magnetic resonance imaging clinics of North America"},{"issue":"11","key":"2686_CR3","doi-asserted-by":"publisher","first-page":"2248","DOI":"10.1007\/s00261-016-0829-1","volume":"41","author":"FF Guglielmo","year":"2016","unstructured":"Guglielmo FF, Kania LM, Ahmad HM, Roth CG, Mitchell DG (2016) Interpreting body MRI cases: what you need to know to get started. Abdominal radiology 41(11): 2248-2269","journal-title":"Abdominal radiology"},{"issue":"5","key":"2686_CR4","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1007\/s002610000083","volume":"25","author":"S Takahashi","year":"2000","unstructured":"Takahashi S, Kim T, Murakami T, Okada A, Hori M, Narumi Y, Nakamura H (2000) Influence of paramagnetic contrast on single-shot MRCP image quality. Abdominal Imaging 25(5): 511-513","journal-title":"Abdominal Imaging"},{"key":"2686_CR5","volume-title":"Fundamentals of Body MRI","author":"CG Roth","year":"2017","unstructured":"Roth CG, Deshmukh S (2017) Fundamentals of Body MRI. Elsevier, Philadelphia"},{"issue":"2","key":"2686_CR6","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. Journal of Chiropractic Medicine 15(2): 155-163","journal-title":"Journal of Chiropractic Medicine"},{"key":"2686_CR7","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1007\/s00261-019-02162-5","volume":"45","author":"CL Welle","year":"2019","unstructured":"Welle CL, Guglielmo FF, Venkatesh SK (2019) MRI of the liver: choosing the right contrast agent. Abdominal radiology 45: 384-392","journal-title":"Abdominal radiology"},{"issue":"4","key":"2686_CR8","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.rcl.2014.02.004","volume":"52","author":"FF Guglielmo","year":"2014","unstructured":"Guglielmo FF, Mitchell DG, Gupta S (2014) Gadolinium contrast agent selection and optimal use for body MR imaging. Radiologic clinics of North America 52(4): 637-656","journal-title":"Radiologic clinics of North America"},{"issue":"3","key":"2686_CR9","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1002\/jmri.22833","volume":"35","author":"A Frydrychowicz","year":"2012","unstructured":"Frydrychowicz A, Lubner MG, Brown JJ, Merkle EM, Nagle SK, Rofsky NM, Reeder SB (2012) Hepatobiliary MR imaging with gadolinium-based contrast agents. Journal of magnetic resonance imaging 35(3): 492-511","journal-title":"Journal of magnetic resonance imaging"},{"key":"2686_CR10","doi-asserted-by":"crossref","unstructured":"Cavagna FM, Maggioni F, Castelli PM, Dapra M, Imperatori LG, Lorusso V, Jenkins BG (1997) Gadolinium chelates with weak binding to serum proteins. A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging. Investigative radiology 32(12): 780\u2013796","DOI":"10.1097\/00004424-199712000-00009"},{"issue":"2","key":"2686_CR11","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.jhep.2012.01.031","volume":"57","author":"BE Van Beers","year":"2012","unstructured":"Van Beers BE, Pastor CM, Hussain HK (2012) Primovist, Eovist: what to expect? Journal of hepatology 57(2): 421-429","journal-title":"Journal of hepatology"},{"issue":"4","key":"2686_CR12","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/j.rcl.2014.02.011","volume":"52","author":"BL Yam","year":"2014","unstructured":"Yam BL, Siegelman ES (2014) MR imaging of the biliary system. Radiologic clinics of North America 52(4): 725-755","journal-title":"Radiologic clinics of North America"},{"issue":"2","key":"2686_CR13","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1148\/radiol.10091130","volume":"255","author":"KI Ringe","year":"2010","unstructured":"Ringe KI, Gupta RT, Brady CM, Massey CM, Hahn A, Galanski M, Merkle EM, Lotz J (2010) Respiratory-triggered three-dimensional T2-weighted MR cholangiography after injection of gadoxetate disodium: is it still reliable? Radiology 255(2): 451-458","journal-title":"Radiology"},{"key":"2686_CR14","doi-asserted-by":"crossref","unstructured":"Yoshida M, Nakaura T, Inoue T, Tanoue S, Takada S, Utsunomiya D, Tsumagari S, Harada K, Yamashita Y. (2018) Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE?. European radiology 28(6): 2436\u20132443","DOI":"10.1007\/s00330-017-5240-y"},{"issue":"3","key":"2686_CR15","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1007\/s00261-003-0119-6","volume":"29","author":"L Van Hoe","year":"2004","unstructured":"Van Hoe L, Mermuys K, Vanhoenacker P (2004) MRCP pitfalls. Abdominal Imaging 29(3): 360-387","journal-title":"Abdominal Imaging"},{"issue":"1","key":"2686_CR16","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/s13244-011-0129-9","volume":"3","author":"N Griffin","year":"2012","unstructured":"Griffin N, Charles-Edwards G, Grant LA (2012) Magnetic resonance cholangiopancreatography: the ABC of MRCP. Insights into imaging 3(1): 11-21","journal-title":"Insights into imaging"},{"issue":"2","key":"2686_CR17","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/j.suc.2014.01.004","volume":"94","author":"K O\u2019Connell","year":"2014","unstructured":"O\u2019Connell K, Brasel K (2014) Bile metabolism and lithogenesis. The Surgical clinics of North America 94(2): 361-375","journal-title":"The Surgical clinics of North America"},{"key":"2686_CR18","doi-asserted-by":"crossref","unstructured":"Angelin B, Bjorkhem I, Einarsson K, Ewerth S (1982) Hepatic uptake of bile acids in man. Fasting and postprandial concentrations of individual bile acids in portal venous and systemic blood serum. The Journal of clinical investigation 70(4): 724\u2013731","DOI":"10.1172\/JCI110668"},{"issue":"3","key":"2686_CR19","first-page":"1035","volume":"3","author":"JL Boyer","year":"2013","unstructured":"Boyer JL (2013) Bile formation and secretion. Comprehensive Physiology 3(3): 1035-107","journal-title":"Physiology"},{"key":"2686_CR20","first-page":"123","volume-title":"Blumgart\u2019s Surgery of the Liver","author":"AP Henry","year":"2017","unstructured":"Henry AP, Attila N (2017) Bile secretion and pathophysiology of biliary tract obstruction. In: Jarnagin W (ed) Blumgart\u2019s Surgery of the Liver, Biliary Tract and Pancreas. Elsevier, p 123"}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-020-02686-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00261-020-02686-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-020-02686-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T23:06:39Z","timestamp":1627859199000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00261-020-02686-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,2]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["2686"],"URL":"https:\/\/doi.org\/10.1007\/s00261-020-02686-1","relation":{},"ISSN":["2366-004X","2366-0058"],"issn-type":[{"value":"2366-004X","type":"print"},{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,2]]},"assertion":[{"value":"7 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 August 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Research support\/grant from Lantheus Medical Imaging, GE Healthcare, and Philips (JKD).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}