{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T22:54:17Z","timestamp":1793573657684,"version":"4.5.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T00:00:00Z","timestamp":1664323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T00:00:00Z","timestamp":1664323200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"DOI":"10.1007\/s00261-022-03687-y","type":"journal-article","created":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T16:02:32Z","timestamp":1664380952000},"page":"282-290","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Accelerated T2-weighted MRI of the liver at 3\u00a0T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection"],"prefix":"10.1007","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0183-7246","authenticated-orcid":false,"given":"Luke A.","family":"Ginocchio","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul N.","family":"Smereka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angela","family":"Tong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinay","family":"Prabhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominik","family":"Nickel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Arberet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hersh","family":"Chandarana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krishna P.","family":"Shanbhogue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,9,28]]},"reference":[{"issue":"1\u20132","key":"3687_CR1","first-page":"42","volume":"9","author":"TK Helmberger","year":"1999","unstructured":"Helmberger TK, Schr\u00f6der J, Holzknecht N, et al. T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging. Magma (New York, NY). 1999;9(1-2):42-51.","journal-title":"Magma (New York, NY)."},{"issue":"22","key":"3687_CR2","doi-asserted-by":"publisher","first-page":"2348","DOI":"10.3748\/wjg.v24.i22.2348","volume":"24","author":"HY Jiang","year":"2018","unstructured":"Jiang HY, Chen J, Xia CC, Cao LK, Duan T, Song B. Noninvasive imaging of hepatocellular carcinoma: From diagnosis to prognosis. World journal of gastroenterology. 2018;24(22):2348-2362.","journal-title":"World journal of gastroenterology."},{"issue":"1","key":"3687_CR3","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1007\/s11427-016-0388-2","volume":"60","author":"Q Su","year":"2017","unstructured":"Su Q, Bi S, Yang X. Prioritization of liver MRI for distinguishing focal lesions. Science China Life sciences. 2017;60(1):28-36.","journal-title":"Science China Life sciences."},{"key":"3687_CR4","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ejrad.2017.05.028","volume":"93","author":"H Donato","year":"2017","unstructured":"Donato H, Fran\u00e7a M, Candel\u00e1ria I, Caseiro-Alves F. Liver MRI: From basic protocol to advanced techniques. European journal of radiology. 2017;93:30-39.","journal-title":"European journal of radiology."},{"issue":"2","key":"3687_CR5","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1148\/radiology.194.2.7824723","volume":"194","author":"JN Rydberg","year":"1995","unstructured":"Rydberg JN, Lomas DJ, Coakley KJ, Hough DM, Ehman RL, Riederer SJ. Comparison of breath-hold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions. Radiology. 1995;194(2):431-437.","journal-title":"Radiology."},{"issue":"2","key":"3687_CR6","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1148\/radiology.194.2.7824701","volume":"194","author":"JW Reinig","year":"1995","unstructured":"Reinig JW. Breath-hold fast spin-echo MR imaging of the liver: a technique for high-quality T2-weighted images. Radiology. 1995;194(2):303-304.","journal-title":"Radiology."},{"issue":"1","key":"3687_CR7","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1148\/radiology.193.1.8090920","volume":"193","author":"EG McFarland","year":"1994","unstructured":"McFarland EG, Mayo-Smith WW, Saini S, Hahn PF, Goldberg MA, Lee MJ. Hepatic hemangiomas and malignant tumors: improved differentiation with heavily T2-weighted conventional spin-echo MR imaging. Radiology. 1994;193(1):43-47.","journal-title":"Radiology."},{"issue":"3","key":"3687_CR8","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1148\/radiology.204.3.9280251","volume":"204","author":"K Ito","year":"1997","unstructured":"Ito K, Mitchell DG, Outwater EK, Szklaruk J, Sadek AG. Hepatic lesions: discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging. Radiology. 1997;204(3):729-737.","journal-title":"Radiology."},{"issue":"2","key":"3687_CR9","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1148\/radiology.190.2.8284393","volume":"190","author":"EK Outwater","year":"1994","unstructured":"Outwater EK, Mitchell DG, Vinitski S. Abdominal MR imaging: evaluation of a fast spin-echo sequence. Radiology. 1994;190(2):425-429.","journal-title":"Radiology."},{"issue":"2","key":"3687_CR10","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/S0033-8389(05)70021-X","volume":"36","author":"ES Siegelman","year":"1998","unstructured":"Siegelman ES, Outwater EK. MR imaging techniques of the liver. Radiologic clinics of North America. 1998;36(2):263-286.","journal-title":"Radiologic clinics of North America."},{"issue":"3","key":"3687_CR11","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/S0720-048X(98)00176-4","volume":"29","author":"T Ichikawa","year":"1999","unstructured":"Ichikawa T, Araki T. Fast magnetic resonance imaging of liver. European journal of radiology. 1999;29(3):186-210.","journal-title":"European journal of radiology."},{"issue":"1","key":"3687_CR12","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1007\/s00261-016-0877-6","volume":"42","author":"J Schreiber-Zinaman","year":"2017","unstructured":"Schreiber-Zinaman J, Rosenkrantz AB. Frequency and reasons for extra sequences in clinical abdominal MRI examinations. Abdominal radiology (New York). 2017;42(1):306-311.","journal-title":"Abdominal radiology (New York)."},{"issue":"5","key":"3687_CR13","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1016\/j.crad.2010.10.018","volume":"66","author":"AB Rosenkrantz","year":"2011","unstructured":"Rosenkrantz AB, Mannelli L, Mossa D, Babb JS. Breath-hold T2-weighted MRI of the liver at 3T using the BLADE technique: impact upon image quality and lesion detection. Clinical radiology. 2011;66(5):426-433.","journal-title":"Clinical radiology."},{"issue":"3","key":"3687_CR14","doi-asserted-by":"publisher","first-page":"634","DOI":"10.2214\/AJR.09.2994","volume":"194","author":"AB Rosenkrantz","year":"2010","unstructured":"Rosenkrantz AB, Patel JM, Babb JS, Storey P, Hecht EM. Liver MRI at 3 T using a respiratory-triggered time-efficient 3D T2-weighted technique: impact on artifacts and image quality. AJR American journal of roentgenology. 2010;194(3):634-641.","journal-title":"AJR American journal of roentgenology."},{"issue":"5","key":"3687_CR15","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1007\/s002619900098","volume":"21","author":"MT Keogan","year":"1996","unstructured":"Keogan MT, Spritzer CE, Paulson EK, et al. Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery. Abdominal imaging. 1996;21(5):433-439.","journal-title":"Abdominal imaging."},{"issue":"3","key":"3687_CR16","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1002\/jmri.1880080319","volume":"8","author":"GG Coates","year":"1998","unstructured":"Coates GG, Borrello JA, McFarland EG, Mirowitz SA, Brown JJ. Hepatic T2-weighted MRI: a prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE). Journal of magnetic resonance imaging : JMRI. 1998;8(3):642-649.","journal-title":"Journal of magnetic resonance imaging : JMRI."},{"issue":"5","key":"3687_CR17","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1002\/jmri.1880080512","volume":"8","author":"JS Yu","year":"1998","unstructured":"Yu JS, Kim KW, Kim YH, Jeong EK, Chien D. Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions. Journal of magnetic resonance imaging : JMRI. 1998;8(5):1079-1084.","journal-title":"Journal of magnetic resonance imaging : JMRI."},{"issue":"3","key":"3687_CR18","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1148\/radiology.203.3.9169702","volume":"203","author":"Y Tang","year":"1997","unstructured":"Tang Y, Yamashita Y, Namimoto T, Abe Y, Takahashi M. Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences. Radiology. 1997;203(3):766-772.","journal-title":"Radiology."},{"issue":"2","key":"3687_CR19","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1002\/jmri.21002","volume":"26","author":"SS Lee","year":"2007","unstructured":"Lee SS, Byun JH, Hong HS, et al. Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. Journal of magnetic resonance imaging : JMRI. 2007;26(2):323-330.","journal-title":"Journal of magnetic resonance imaging : JMRI."},{"issue":"1","key":"3687_CR20","doi-asserted-by":"publisher","first-page":"W19","DOI":"10.2214\/AJR.07.2043","volume":"190","author":"BS Kim","year":"2008","unstructured":"Kim BS, Kim JH, Choi GM, et al. Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions. AJR American journal of roentgenology. 2008;190(1):W19-27.","journal-title":"AJR American journal of roentgenology."},{"issue":"5","key":"3687_CR21","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1007\/s002619900097","volume":"21","author":"P Reimer","year":"1996","unstructured":"Reimer P, Rummeny EJ, Wissing M, Bongartz GM, Schuierer G, Peters PE. Hepatic MR imaging: comparison of RARE derived sequences with conventional sequences for detection and characterization of focal liver lesions. Abdominal imaging. 1996;21(5):427-432.","journal-title":"Abdominal imaging."},{"issue":"6","key":"3687_CR22","doi-asserted-by":"publisher","first-page":"3055","DOI":"10.1002\/mrm.26977","volume":"79","author":"K Hammernik","year":"2018","unstructured":"Hammernik K, Klatzer T, Kobler E, et al. Learning a variational network for reconstruction of accelerated MRI data. Magnetic resonance in medicine. 2018;79(6):3055-3071.","journal-title":"Magnetic resonance in medicine."},{"issue":"2","key":"3687_CR23","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1148\/radiol.2018180445","volume":"289","author":"F Chen","year":"2018","unstructured":"Chen F, Taviani V, Malkiel I, et al. Variable-Density Single-Shot Fast Spin-Echo MRI with Deep Learning Reconstruction by Using Variational Networks. Radiology. 2018;289(2):366-373.","journal-title":"Radiology."},{"issue":"2","key":"3687_CR24","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1109\/TMI.2017.2760978","volume":"37","author":"J Schlemper","year":"2018","unstructured":"Schlemper J, Caballero J, Hajnal JV, Price AN, Rueckert D. A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction. IEEE transactions on medical imaging. 2018;37(2):491-503.","journal-title":"IEEE transactions on medical imaging."},{"issue":"1","key":"3687_CR25","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1109\/TMI.2018.2863670","volume":"38","author":"C Qin","year":"2019","unstructured":"Qin C, Schlemper J, Caballero J, Price AN, Hajnal JV, Rueckert D. Convolutional Recurrent Neural Networks for Dynamic MR Image Reconstruction. IEEE transactions on medical imaging. 2019;38(1):280-290.","journal-title":"IEEE transactions on medical imaging."},{"key":"3687_CR26","doi-asserted-by":"crossref","unstructured":"Shanbhogue K, Tong A, Smereka P, et al. Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning-based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence. European radiology. 2021.","DOI":"10.1007\/s00330-021-08008-3"},{"key":"3687_CR27","doi-asserted-by":"crossref","unstructured":"Laader A, Beiderwellen K, Kraff O, et al. 1.5 versus 3 versus 7 Tesla in abdominal MRI: A comparative study. PloS one. 2017;12(11):e0187528.","DOI":"10.1371\/journal.pone.0187528"},{"key":"3687_CR28","doi-asserted-by":"crossref","unstructured":"Kuhl CK, Tr\u00e4ber F, Schild HH. Whole-body high-field-strength (3.0-T) MR Imaging in Clinical Practice. Part I. Technical considerations and clinical applications. Radiology. 2008;246(3):675\u2013696.","DOI":"10.1148\/radiol.2463060881"},{"issue":"6","key":"3687_CR29","doi-asserted-by":"publisher","first-page":"1448","DOI":"10.1002\/jmri.21350","volume":"27","author":"TC Lauenstein","year":"2008","unstructured":"Lauenstein TC, Sharma P, Hughes T, Heberlein K, Tudorascu D, Martin DR. Evaluation of optimized inversion-recovery fat-suppression techniques for T2-weighted abdominal MR imaging. Journal of magnetic resonance imaging : JMRI. 2008;27(6):1448-1454.","journal-title":"Journal of magnetic resonance imaging : JMRI."},{"issue":"5","key":"3687_CR30","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1002\/mrm.1910320515","volume":"32","author":"T Parrish","year":"1994","unstructured":"Parrish T, Hu X. A new T2 preparation technique for ultrafast gradient-echo sequence. Magnetic resonance in medicine. 1994;32(5):652-657.","journal-title":"Magnetic resonance in medicine."},{"issue":"5","key":"3687_CR31","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1002\/jmri.20293","volume":"21","author":"C Klessen","year":"2005","unstructured":"Klessen C, Asbach P, Kroencke TJ, et al. Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction. Journal of magnetic resonance imaging : JMRI. 2005;21(5):576-582.","journal-title":"Journal of magnetic resonance imaging : JMRI."}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-022-03687-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00261-022-03687-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-022-03687-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,18]],"date-time":"2023-01-18T04:11:14Z","timestamp":1674015074000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00261-022-03687-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,28]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["3687"],"URL":"https:\/\/doi.org\/10.1007\/s00261-022-03687-y","relation":{},"ISSN":["2366-0058"],"issn-type":[{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,28]]},"assertion":[{"value":"26 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 September 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dominik Nickel: Siemens Healthcare employee, who provided technical assistance, but was not involved in the data acquisition or evaluation, nor did he have direct control of the data - Simon Arberet: Siemens Healthcare employee, who provided technical assistance, but was not involved in the data acquisition or evaluation, nor did he have direct control of the data - Other Authors: No relevant disclosures.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}