{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T07:10:50Z","timestamp":1791616250561,"version":"4.3.4"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T00:00:00Z","timestamp":1718668800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T00:00:00Z","timestamp":1718668800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["23K07179"],"award-info":[{"award-number":["23K07179"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004206","name":"Osaka University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004206","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Photon-counting CT has a completely different detector mechanism than conventional energy-integrating CT. In the photon-counting detector, X-rays are directly converted into electrons and received as electrical signals. Photon-counting CT provides virtual monochromatic images with a high contrast-to-noise ratio for abdominal CT imaging and may improve the ability to visualize small or low-contrast lesions. In addition, photon-counting CT may offer the possibility of reducing radiation dose. This review provides an overview of the actual clinical operation of photon-counting CT and its diagnostic utility in abdominal imaging. We also describe the clinical implications of photon-counting CT including imaging of hepatocellular carcinoma, liver metastases, hepatic steatosis, pancreatic cancer, intraductal mucinous neoplasm of the pancreas, and thrombus.<\/jats:p>\n                  <jats:p>\n                    <jats:bold>Graphical Abstract<\/jats:bold>\n                  <\/jats:p>","DOI":"10.1007\/s00261-024-04414-5","type":"journal-article","created":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T01:01:55Z","timestamp":1718672515000},"page":"4383-4399","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Photon-counting CT: technical features and clinical impact on abdominal imaging"],"prefix":"10.1007","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3241-5994","authenticated-orcid":false,"given":"Hiromitsu","family":"Onishi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Tsuboyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Nakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Ota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideyuki","family":"Fukui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuaki","family":"Tatsumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toru","family":"Honda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kengo","family":"Kiso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shohei","family":"Matsumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koki","family":"Kaketaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukihiro","family":"Enchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuichi","family":"Kawabata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinya","family":"Nakasone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noriyuki","family":"Tomiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,6,18]]},"reference":[{"issue":"4","key":"4414_CR1","doi-asserted-by":"publisher","first-page":"719","DOI":"10.2214\/ajr.160.4.8456652","volume":"160","author":"RK Zeman","year":"1993","unstructured":"Zeman RK, Fox SH, Silverman PM, et al. Helical (spiral) CT of the abdomen. AJR Am J Roentgenol. 1993 Apr;160(4):719-25.","journal-title":"AJR Am J Roentgenol."},{"key":"4414_CR2","doi-asserted-by":"crossref","unstructured":"Agrawal MD, Pinho DF, Kulkarni NM, Hahn PF, Guimaraes AR, Sahani DV. Oncologic applications of dual-energy CT in the abdomen. Radiographics. 2014 May-Jun;34(3):589\u2013612.","DOI":"10.1148\/rg.343135041"},{"key":"4414_CR3","doi-asserted-by":"crossref","unstructured":"Elbanna KY, Mansoori B, Mileto A, Rogalla P, S Guimar\u00e3es L. Dual-energy CT in diffuse liver disease: is there a role? Abdom Radiol (NY). 2020 Nov;45(11):3413\u20133424.","DOI":"10.1007\/s00261-020-02702-4"},{"key":"4414_CR4","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1097\/RLI.0000000000000680","volume":"55","author":"JE Wildberger","year":"2020","unstructured":"Wildberger JE, Prokop M. Hounsfield\u2019s Legacy. Investig Radiol 2020; 55:556\u2013558.","journal-title":"Hounsfield\u2019s Legacy. Investig Radiol"},{"key":"4414_CR5","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.8.5.052109","volume":"8","author":"J Hsieh","year":"2021","unstructured":"Hsieh J, Flohr T. Computed tomography recent history and future perspectives. J Med Imaging 2021; 8:052109","journal-title":"J Med Imaging"},{"issue":"3","key":"4414_CR6","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1148\/radiol.2293030590","volume":"229","author":"T Murakami","year":"2003","unstructured":"Murakami T, Kim T, Hori M, Federle MP. Double arterial phase multi-detector row helical CT for detection of hypervascular hepatocellular carcinoma. Radiology. 2003 Dec;229(3):931-2.","journal-title":"Radiology."},{"key":"4414_CR7","doi-asserted-by":"crossref","unstructured":"Nino-Murcia M, Tamm EP, Charnsangavej C, Jeffrey RB Jr. Multidetector-row helical CT and advanced postprocessing techniques for the evaluation of pancreatic neoplasms. Abdom Imaging. 2003 May-Jun;28(3):366\u201377.","DOI":"10.1007\/s00261-002-0056-9"},{"issue":"1","key":"4414_CR8","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1148\/radiol.2017160130","volume":"283","author":"T Hyodo","year":"2017","unstructured":"Hyodo T, Yada N, Hori M, et al. Multimaterial Decomposition Algorithm for the Quantification of Liver Fat Content by Using Fast-Kilovolt-Peak Switching Dual-Energy CT: Clinical Evaluation. Radiology. 2017 Apr;283(1):108-118.","journal-title":"Radiology."},{"key":"4414_CR9","doi-asserted-by":"crossref","unstructured":"Okada M, Kim T, Murakami T. Hepatocellular nodules in liver cirrhosis: state of the art CT evaluation (perfusion CT\/volume helical shuttle scan\/dual-energy CT, etc.). Abdom Imaging. 2011 Jun;36(3):273\u201381.","DOI":"10.1007\/s00261-011-9684-2"},{"issue":"1","key":"4414_CR10","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222432","volume":"309","author":"PC Douek","year":"2023","unstructured":"Douek PC, Boccalini S, Oei EHG, et al. Clinical Applications of Photon-counting CT: A Review of Pioneer Studies and a Glimpse into the Future. Radiology 2023; 309(1):e222432","journal-title":"Radiology"},{"key":"4414_CR11","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A, et al. Photon-counting CT: technical principles and clinical prospects. Radiology. 2018;289:293\u2013312.","journal-title":"Radiology."},{"key":"4414_CR12","doi-asserted-by":"crossref","unstructured":"DanielssonM, Persson M, Sj\u00f6lin M. Photon-counting x-ray detectors for CT. Phys Med Biol. 2021;66:03tr1.","DOI":"10.1088\/1361-6560\/abc5a5"},{"key":"4414_CR13","doi-asserted-by":"crossref","unstructured":"Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-Counting CT review. Phys Med 2020; 79: S1120\u20131797(20)30273\u20138:126\u201336:","DOI":"10.1016\/j.ejmp.2020.10.030"},{"key":"4414_CR14","doi-asserted-by":"crossref","unstructured":"Pourmorteza A, Symons R, Reich DS, et al. Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment. AJNR Am J Neuroradiol. 2017 Dec;38(12):2257\u20132263.","DOI":"10.3174\/ajnr.A5402"},{"issue":"3","key":"4414_CR15","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1097\/RLI.0000000000000418","volume":"53","author":"R Symons","year":"2018","unstructured":"Symons R, Reich DS, Bagheri M, et al. Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results. Invest Radiol. 2018 Mar;53(3):135-142.","journal-title":"Invest Radiol."},{"key":"4414_CR16","doi-asserted-by":"publisher","first-page":"5321","DOI":"10.1007\/s00330-023-09545-9","volume":"33","author":"CH McCollough","year":"2023","unstructured":"McCollough, C.H., Rajendran, K., Leng, S. et al. The technical development of photon-counting detector CT. Eur Radiol 33, 5321\u20135330 (2023).","journal-title":"Eur Radiol"},{"issue":"5","key":"4414_CR17","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1016\/j.acra.2022.05.021","volume":"30","author":"R Wrazidlo","year":"2023","unstructured":"Wrazidlo R, Walder L, Estler A, et al. Radiation Dose Reduction in Contrast-Enhanced Abdominal CT: Comparison of Photon-Counting Detector CT with 2nd Generation Dual-Source Dual-Energy CT in an oncologic cohort. Acad Radiol. 2023 May;30(5):855-862.","journal-title":"Acad Radiol."},{"key":"4414_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110181","volume":"148","author":"JA Decker","year":"2022","unstructured":"Decker JA, Bette S, Lubina N, et al. Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT. Eur J Radiol. 2022 Mar;148:110181.","journal-title":"Eur J Radiol."},{"issue":"7","key":"4414_CR19","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/RLI.0000000000000949","volume":"58","author":"FR Schwartz","year":"2023","unstructured":"Schwartz FR, Samei E, Marin D. Exploiting the Potential of Photon-Counting CT in Abdominal Imaging. Invest Radiol. 2023 Jul 1;58(7):488-498.","journal-title":"Invest Radiol."},{"key":"4414_CR20","doi-asserted-by":"crossref","unstructured":"Hagen F, Hofmann J, Wrazidlo R, et al. Image quality and dose exposure of contrast-enhanced abdominal CT on a 1st generation clinical dual-source photon-counting detector CT in obese patients vs. a 2nd generation dual-source dual energy integrating detector CT. Eur J Radiol. 2022 Jun;151:110325.","DOI":"10.1016\/j.ejrad.2022.110325"},{"key":"4414_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2020.108909","volume":"126","author":"S Sawall","year":"2020","unstructured":"Sawall S, Klein L, Amato C, et al. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol. 2020 May;126:108909.","journal-title":"Eur J Radiol."},{"key":"4414_CR22","doi-asserted-by":"crossref","unstructured":"Hagen F, Estler A, Hofmann J, et al. Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT. Eur J Radiol. 2023 Dec;169:111153.","DOI":"10.1016\/j.ejrad.2023.111153"},{"issue":"2","key":"4414_CR23","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1148\/radiol.211931","volume":"303","author":"T Sartoretti","year":"2022","unstructured":"Sartoretti T, Landsmann A, Nakhostin D, et al. Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality. Radiology. 2022 May;303(2):339-348.","journal-title":"Radiology."},{"issue":"5","key":"4414_CR24","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/j.acra.2021.06.018","volume":"29","author":"K Higashigaito","year":"2022","unstructured":"Higashigaito K, Euler A, Eberhard M, Flohr TG, Schmidt B, Alkadhi H. Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT. Acad Radiol. 2022 May;29(5):689-697.","journal-title":"Acad Radiol."},{"issue":"Suppl 1","key":"4414_CR25","doi-asserted-by":"publisher","first-page":"S143","DOI":"10.1016\/j.acra.2023.03.026","volume":"30","author":"D Graafen","year":"2023","unstructured":"Graafen D, M\u00fcller L, Halfmann MC, et al. Soft Reconstruction Kernels Improve HCC Imaging on a Photon-Counting Detector CT. Acad Radiol. 2023 Sep;30 Suppl 1:S143-S154.","journal-title":"Acad Radiol."},{"issue":"5","key":"4414_CR26","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.3390\/diagnostics12051231","volume":"12","author":"S Bette","year":"2022","unstructured":"Bette S, Decker JA, Braun FM, et al. Optimal Conspicuity of Liver Metastases in Virtual Monochromatic Imaging Reconstructions on a Novel Photon-Counting Detector CT-Effect of keV Settings and BMI. Diagnostics (Basel). 2022;12(5):1231.","journal-title":"Diagnostics (Basel)."},{"key":"4414_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110514","volume":"156","author":"D Graafen","year":"2022","unstructured":"Graafen D, M\u00fcller L, Halfmann M, D\u00fcber C, Hahn F, Yang Y, Emrich T, Kloeckner R. Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT. Eur J Radiol. 2022;156:110514.","journal-title":"Eur J Radiol."},{"key":"4414_CR28","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1148\/radiol.2015142631","volume":"276","author":"CH McCollough","year":"2015","unstructured":"McCollough CH, Leng S,Yu L, et al. Dual- andmulti-energy CT: principles, technical approaches, and clinical applications. Radiology. 2015;276:637\u2013653.","journal-title":"Radiology."},{"issue":"6","key":"4414_CR29","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.3390\/diagnostics12061467","volume":"12","author":"R Booij","year":"2022","unstructured":"Booij R, van der Werf NR, Dijkshoorn ML, van der Lugt A, van Straten M. Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data. Diagnostics (Basel). 2022;12(6):1467.","journal-title":"Diagnostics (Basel)."},{"issue":"2","key":"4414_CR30","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1148\/radiol.2018180126","volume":"289","author":"RP Marcus","year":"2018","unstructured":"Marcus RP, Fletcher JG, Ferrero A, et al. Detection and Characterization of Renal Stones by Using Photon-Counting-based CT. Radiology. 2018;289(2):436-442.","journal-title":"Radiology."},{"issue":"9","key":"4414_CR31","doi-asserted-by":"publisher","first-page":"6631","DOI":"10.1007\/s00330-021-07786-0","volume":"31","author":"S Sawall","year":"2021","unstructured":"Sawall S, Klein L, Wehrse E, Rotkopf LT, Amato C, Maier J, Schlemmer HP, Ziener CH, Heinze S, Kachelrie\u00df M. Threshold-dependent iodine imaging and spectral separation in a whole-body photon-counting CT system. Eur Radiol. 2021 Sep;31(9):6631-6639.","journal-title":"Eur Radiol."},{"key":"4414_CR32","doi-asserted-by":"crossref","unstructured":"Racine D, Mergen V, Viry A, Frauenfelder T, Alkadhi H, Vitzthum V, Euler A. Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses. Invest Radiol. 2024 Jan 9.","DOI":"10.1097\/RLI.0000000000001060"},{"issue":"8","key":"4414_CR33","doi-asserted-by":"publisher","first-page":"5309","DOI":"10.1007\/s00330-023-09596-y","volume":"33","author":"CH McCollough","year":"2023","unstructured":"McCollough CH, Rajendran K, Baffour FI, et al. Clinical applications of photon counting detector CT. Eur Radiol. 2023 Aug;33(8):5309-5320.","journal-title":"Eur Radiol."},{"issue":"7","key":"4414_CR34","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/RLI.0000000000000860","volume":"57","author":"T Sartoretti","year":"2022","unstructured":"Sartoretti T, Mergen V, Higashigaito K, Eberhard M, Alkadhi H, Euler A. Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography: A Systematic Phantom and Patient Study. Invest Radiol. 2022 Jul 1;57(7):488-493.","journal-title":"Invest Radiol."},{"issue":"1","key":"4414_CR35","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1148\/radiol.213260","volume":"305","author":"V Mergen","year":"2022","unstructured":"Mergen V, Racine D, Jungblut L, et al. Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT. Radiology. 2022 Oct;305(1):107-115.","journal-title":"Radiology."},{"key":"4414_CR36","doi-asserted-by":"crossref","unstructured":"Burkhart RA, Pawlik TM. Staging and Prognostic Models for Hepatocellular Carcinoma and Intrahepatic Cholangiocarcinoma. Cancer Control. 2017 Jul-Sep;24(3):1073274817729235.","DOI":"10.1177\/1073274817729235"},{"issue":"4","key":"4414_CR37","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1001\/jamasurg.2022.7989","volume":"158","author":"ZJ Brown","year":"2023","unstructured":"Brown ZJ, Tsilimigras DI, Ruff SM, et al. Management of Hepatocellular Carcinoma: A Review. JAMA Surg. 2023 Apr 1;158(4):410-420.","journal-title":"JAMA Surg."},{"issue":"4","key":"4414_CR38","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1007\/s00330-011-2316-y","volume":"22","author":"H Onishi","year":"2012","unstructured":"Onishi H, Kim T, Imai Y, et al. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Eur Radiol. 2012 Apr;22(4):845-54.","journal-title":"Eur Radiol."},{"key":"4414_CR39","doi-asserted-by":"crossref","unstructured":"Kuchay MS, Choudhary NS, Mishra SK. Pathophysiological mechanisms underlying MAFLD. Diabetes Metab Syndr. 2020 Nov-Dec;14(6):1875\u20131887.","DOI":"10.1016\/j.dsx.2020.09.026"},{"issue":"2","key":"4414_CR40","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1148\/radiol.2016160129","volume":"282","author":"T Hyodo","year":"2017","unstructured":"Hyodo T, Hori M, Lamb P, et al. Multimaterial Decomposition Algorithm for the Quantification of Liver Fat Content by Using Fast-Kilovolt-Peak Switching Dual-Energy CT: Experimental Validation. Radiology. 2017;282(2):381-389.","journal-title":"Radiology."},{"key":"4414_CR41","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110185","volume":"149","author":"JH Niehoff","year":"2022","unstructured":"Niehoff JH, Woeltjen MM, Saeed S, et al. Assessment of hepatic steatosis based on virtual non-contrast computed tomography: Initial experiences with a photon counting scanner approved for clinical use. Eur J Radiol. 2022 Apr;149:110185.","journal-title":"Eur J Radiol."},{"key":"4414_CR42","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2024.103210","volume":"118","author":"S Holl\u00fd","year":"2024","unstructured":"Holl\u00fd S, Chmel\u00edk M, Such\u00e1 S, et al. Photon-counting CT using multi-material decomposition algorithm enables fat quantification in the presence of iron deposits. Phys Med. 2024 Feb;118:103210.","journal-title":"Phys Med."},{"issue":"520","key":"4414_CR43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.canlet.2021.06.027","volume":"1","author":"J Cai","year":"2021","unstructured":"Cai J, Chen H, Lu M, et al. Advances in the epidemiology of pancreatic cancer: Trends, risk factors, screening, and prognosis. Cancer Lett. 2021 Nov 1;520:1-11.","journal-title":"Cancer Lett."},{"key":"4414_CR44","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1007\/s00261-017-1330-1","volume":"43","author":"NS Gandhi","year":"2018","unstructured":"Gandhi NS, Feldman MK, Le O, et al. Imaging mimics of pancreatic ductal adenocarcinoma. Abdom Radiol (NY). 2018;43:273\u2013284.","journal-title":"Abdom Radiol (NY)."},{"issue":"1","key":"4414_CR45","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s00261-023-04042-5","volume":"49","author":"JA Decker","year":"2024","unstructured":"Decker JA, Becker J, H\u00e4rting M, et al. Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT. Abdom Radiol (NY). 2024 Jan;49(1):103-116.","journal-title":"Abdom Radiol (NY)."},{"issue":"9791","key":"4414_CR46","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1016\/S0140-6736(10)62307-0","volume":"378","author":"A Vincent","year":"2011","unstructured":"Vincent A, Herman J, Schulick R, et al. Pancreatic cancer. Lancet. 2011 Aug 13;378(9791):607-20.","journal-title":"Lancet."},{"key":"4414_CR47","doi-asserted-by":"crossref","unstructured":"Kim J, Mabud T, Huang C, et al. Inter-reader agreement of pancreatic adenocarcinoma resectability assessment with photon counting versus energy integrating detector CT. Abdom Radiol (NY). 2024 Apr 17.","DOI":"10.1007\/s00261-024-04298-5"},{"key":"4414_CR48","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1038\/nrgastro.2012.31","volume":"9","author":"J Werner","year":"2012","unstructured":"Werner J, Fritz S, Buchler MW. Intraductal papillary mucinous neoplasms of the pancreas: a surgical disease. Nat Rev Gastroenterol Hepatol. 2012; 9:253\u2013259.","journal-title":"Nat Rev Gastroenterol Hepatol."},{"key":"4414_CR49","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/978-1-4939-8879-2_2","volume":"1882","author":"M Tanaka","year":"2019","unstructured":"Tanaka M. Clinical Management and Surgical Decision-Making of IPMN of the Pancreas. Methods Mol Biol. 2019;1882:9-22.","journal-title":"Methods Mol Biol."},{"issue":"175","key":"4414_CR50","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111437","volume":"20","author":"B Dane","year":"2024","unstructured":"Dane B, Kim J, Qian K, Megibow A. Pancreatic cyst prevalence and detection with photon counting CT compared with conventional energy integrating detector CT. Eur J Radiol. 2024 Mar 20;175:111437.","journal-title":"Eur J Radiol."},{"key":"4414_CR51","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.pan.2012.04.004","volume":"12","author":"M Tanaka","year":"2012","unstructured":"Tanaka M, Fernandez del Castillo C, Adsay V et al (2012) International consensus guidelines 2012 for the management of IPMN and MCN of the pancreas. Pancreatology 12:183\u2013197","journal-title":"Pancreatology"},{"key":"4414_CR52","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.2214\/AJR.05.0983","volume":"186","author":"SS Raman","year":"2006","unstructured":"Raman SS, Pojchamarnwiputh S, Muangsomboon K, et al. Utility of 16-MDCT angiography for comprehensive preoperative vascular evaluation of laparoscopic renal donors. AJR Am J Roentgenol 2006;186:1630\u20131638.","journal-title":"AJR Am J Roentgenol"},{"key":"4414_CR53","doi-asserted-by":"crossref","unstructured":"Kumar S, Neyaz Z, Gupta A. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay. Korean J Radiol. 2010 May-Jun;11(3):346\u201354.","DOI":"10.3348\/kjr.2010.11.3.346"},{"issue":"7","key":"4414_CR54","first-page":"499","volume":"58","author":"JE Wildberger","year":"2023","unstructured":"Wildberger JE, Alkadhi H. New Horizons in Vascular Imaging with Photon-Counting Detector CT. Invest Radiol. 2023 Jul 1;58(7):499-504.","journal-title":"Invest Radiol."},{"issue":"5","key":"4414_CR55","doi-asserted-by":"publisher","first-page":"938","DOI":"10.3390\/diagnostics13050938","volume":"13","author":"D Dillinger","year":"2023","unstructured":"Dillinger D, Overhoff D, Booz C, et al. Diagnostics (Basel). 2023 Mar 1;13(5):938.","journal-title":"Diagnostics (Basel)."},{"issue":"4","key":"4414_CR56","doi-asserted-by":"publisher","first-page":"1404","DOI":"10.1016\/j.radcr.2024.01.020","volume":"19","author":"M Kisohara","year":"2024","unstructured":"Kisohara M, Kitera N, Itoh T, et al. Radiol Case Rep. 2024 Jan 16;19(4):1404-1408.","journal-title":"Radiol Case Rep."}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-024-04414-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00261-024-04414-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-024-04414-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,29]],"date-time":"2024-10-29T07:07:30Z","timestamp":1730185650000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00261-024-04414-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,18]]},"references-count":56,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4414"],"URL":"https:\/\/doi.org\/10.1007\/s00261-024-04414-5","relation":{},"ISSN":["2366-0058"],"issn-type":[{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,18]]},"assertion":[{"value":"28 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflicts of interest associated with this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}