{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T13:40:23Z","timestamp":1769262023888,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T00:00:00Z","timestamp":1750982400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T00:00:00Z","timestamp":1750982400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Abdom Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>MRCP is essential for noninvasive evaluation of the biliary and pancreatic ductal systems in children but can suffer from suboptimal image quality due to inconsistent protocols and technical factors. We performed a quality improvement project focused on enhancing the image quality of 3D MRCP at a tertiary children\u2019s hospital. The project identified key contributors to poor image quality, including the inconsistent use of respiratory-triggered techniques and the absence of standardized protocols across multiple MRI units. Interventions were implemented, including updating protocols, technologist education, and improving communication between radiologists and technologists. We set a goal of achieving 90% of MRCP exams with acceptable image quality by September 2024. Our efforts increased the success rate from 68 to 77%. Although the target was not fully reached by the end of the set project timeline, the effort highlights the importance of multidisciplinary collaboration, continuous education, and ongoing auditing in driving improvements in imaging quality.<\/jats:p>","DOI":"10.1007\/s00261-025-05063-y","type":"journal-article","created":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T02:22:23Z","timestamp":1750990943000},"page":"127-136","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pediatric 3D MRCP imaging: strategies for enhancing exam quality"],"prefix":"10.1007","volume":"51","author":[{"given":"Mohammad","family":"Jalloul","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sudha A.","family":"Anupindi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shyam S. B.","family":"Venkatakrishna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhay S.","family":"Srinivasan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael R.","family":"Acord","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge","family":"Delgado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Levy C.","family":"Onyango","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youck Jen","family":"Siu Navarro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janet R.","family":"Reid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rebecca","family":"Dennis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valerie A.","family":"Rigby","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Summer L.","family":"Kaplan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suraj D.","family":"Serai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,27]]},"reference":[{"key":"5063_CR1","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.mric.2013.04.009","volume":"21","author":"ND Egbert","year":"2013","unstructured":"Egbert ND, Bloom DA, Dillman JR (2013) Magnetic resonance imaging of the pediatric pancreaticobiliary system. Magn Reson Imaging Clin N Am 21:681\u2013696. https:\/\/doi.org\/10.1016\/j.mric.2013.04.009","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"5063_CR2","doi-asserted-by":"publisher","first-page":"910","DOI":"10.2214\/AJR.21.26954","volume":"218","author":"A Glenn","year":"2022","unstructured":"Glenn A, Trout AT, Kocaoglu M, Ata NA, Crotty EJ, Tkach JA, Dillman JR (2022) Patient- and examination-related predictors of 3D MRCP image quality in children. AJR Am J Roentgenol 218:910\u2013916. https:\/\/doi.org\/10.2214\/AJR.21.26954","journal-title":"AJR Am J Roentgenol"},{"key":"5063_CR3","doi-asserted-by":"publisher","first-page":"e0154178","DOI":"10.1371\/journal.pone.0154178","volume":"11","author":"S-G Huang","year":"2016","unstructured":"Huang S-G, Guo W-L, Wang J, Sheng M, Lan X-H, Fang L (2016) Factors interfering with delineation on MRCP of pancreaticobiliary maljunction in paediatric patients. PLoS One 11:e0154178. https:\/\/doi.org\/10.1371\/journal.pone.0154178","journal-title":"PLoS One"},{"key":"5063_CR4","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1002\/jmri.24033","volume":"38","author":"T Nakaura","year":"2013","unstructured":"Nakaura T, Kidoh M, Maruyama N, Kawahara T, Namimoto T, Sakai Y, Harada K, Yamashita Y (2013) Usefulness of the SPACE pulse sequence at 1.5T MR cholangiography: comparison of image quality and image acquisition time with conventional 3D-TSE sequence. J Magn Reson Imaging 38:1014\u20131019. https:\/\/doi.org\/10.1002\/jmri.24033","journal-title":"J Magn Reson Imaging"},{"key":"5063_CR5","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1002\/jmri.21484","volume":"28","author":"S Arizono","year":"2008","unstructured":"Arizono S, Isoda H, Maetani YS, Hirokawa Y, Shimada K, Nakamoto Y, Togashi K (2008) High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3T: comparison with the conventional constant flip angle sequence in healthy volunteers. J Magn Reson Imaging 28:685\u2013690. https:\/\/doi.org\/10.1002\/jmri.21484","journal-title":"J Magn Reson Imaging"},{"key":"5063_CR6","doi-asserted-by":"publisher","first-page":"e28","DOI":"10.2349\/biij.4.4.e28","volume":"4","author":"G Mandarano","year":"2008","unstructured":"Mandarano G, Sim J (2008) The diagnostic MRCP examination: overcoming technical challenges to ensure clinical success. Biomed Imaging Interv J 4:e28. https:\/\/doi.org\/10.2349\/biij.4.4.e28","journal-title":"Biomed Imaging Interv J"},{"key":"5063_CR7","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1002\/jmri.24850","volume":"42","author":"M Zaitsev","year":"2015","unstructured":"Zaitsev M, Maclaren J, Herbst M (2015) Motion artifacts in MRI: a complex problem with many partial solutions. J Magn Reson Imaging 42:887\u2013901. https:\/\/doi.org\/10.1002\/jmri.24850","journal-title":"J Magn Reson Imaging"},{"key":"5063_CR8","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1148\/radiology.160.3.3737921","volume":"160","author":"CE Lewis","year":"1986","unstructured":"Lewis CE, Prato FS, Drost DJ, Nicholson RL (1986) Comparison of respiratory triggering and gating techniques for the removal of respiratory artifacts in MR imaging. Radiology 160:803\u2013810. https:\/\/doi.org\/10.1148\/radiology.160.3.3737921","journal-title":"Radiology"},{"key":"5063_CR9","unstructured":"MRI Navigators\u00a0| Phase scout navigators\u00a0| Liver dome navigators. https:\/\/mrimaster.com\/mri-navigators\/. Accessed 18 Mar 2025"},{"issue":"Suppl 1","key":"5063_CR10","doi-asserted-by":"publisher","first-page":"i3-9","DOI":"10.1136\/qshc.2008.029066","volume":"17","author":"F Davidoff","year":"2008","unstructured":"Davidoff F, Batalden P, Stevens D, Ogrinc G, Mooney S, SQUIRE Development Group (2008) Publication guidelines for quality improvement in health care: evolution of the SQUIRE project. Qual Saf Health Care 17 Suppl 1:i3-9. https:\/\/doi.org\/10.1136\/qshc.2008.029066","journal-title":"Qual Saf Health Care"},{"key":"5063_CR11","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1136\/bmjqs-2013-001862","volume":"23","author":"MJ Taylor","year":"2014","unstructured":"Taylor MJ, McNicholas C, Nicolay C, Darzi A, Bell D, Reed JE (2014) Systematic review of the application of the plan-do-study-act method to improve quality in healthcare. BMJ Qual Saf 23:290\u2013298. https:\/\/doi.org\/10.1136\/bmjqs-2013-001862","journal-title":"BMJ Qual Saf"},{"key":"5063_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/00185868.2020.1824137","volume":"99","author":"AJ Karkhanis","year":"2021","unstructured":"Karkhanis AJ, Thompson JM (2021) Improving the effectiveness of root cause analysis in hospitals. Hosp Top 99:1\u201314. https:\/\/doi.org\/10.1080\/00185868.2020.1824137","journal-title":"Hosp Top"},{"key":"5063_CR13","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1002\/jmri.26863","volume":"51","author":"M He","year":"2020","unstructured":"He M, Xu J, Sun Z, Wang S, Zhu L, Wang X, Wang J, Feng F, Xue H, Jin Z (2020) Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient- and spin-echo (GRASE) in breath-hold (BH) magnetic resonance cholangiopancreatography (MRCP). J Magn Reson Imaging 51:824\u2013832. https:\/\/doi.org\/10.1002\/jmri.26863","journal-title":"J Magn Reson Imaging"},{"key":"5063_CR14","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1136\/qhc.12.6.458","volume":"12","author":"JC Benneyan","year":"2003","unstructured":"Benneyan JC, Lloyd RC, Plsek PE (2003) Statistical process control as a tool for research and healthcare improvement. Qual Saf Health Care 12:458\u2013464. https:\/\/doi.org\/10.1136\/qhc.12.6.458","journal-title":"Qual Saf Health Care"},{"key":"5063_CR15","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/s13244-011-0129-9","volume":"3","author":"N Griffin","year":"2012","unstructured":"Griffin N, Charles-Edwards G, Grant LA (2012) Magnetic resonance cholangiopancreatography: the ABC of MRCP. Insights Imaging 3:11\u201321. https:\/\/doi.org\/10.1007\/s13244-011-0129-9","journal-title":"Insights Imaging"},{"key":"5063_CR16","doi-asserted-by":"publisher","first-page":"20130036","DOI":"10.1259\/bjr.20130036","volume":"86","author":"A Almehdar","year":"2013","unstructured":"Almehdar A, Chavhan GB (2013) MR cholangiopancreatography at 3.0 T in children: diagnostic quality and ability in assessment of common paediatric pancreatobiliary pathology. Br J Radiol 86:20130036. https:\/\/doi.org\/10.1259\/bjr.20130036","journal-title":"Br J Radiol"},{"key":"5063_CR17","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.2214\/AJR.19.21399","volume":"213","author":"Z Chen","year":"2019","unstructured":"Chen Z, Sun B, Duan Q, Xue Y, Zheng E, He Y, Li G (2019) Three-dimensional breath-hold MRCP using SPACE pulse sequence at 3 T: comparison with conventional navigator-triggered technique. AJR Am J Roentgenol 213:1247\u20131252. https:\/\/doi.org\/10.2214\/AJR.19.21399","journal-title":"AJR Am J Roentgenol"},{"key":"5063_CR18","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1002\/mrm.1910340617","volume":"34","author":"DA Feinberg","year":"1995","unstructured":"Feinberg DA, Rofsky NM, Johnson G (1995) Multiple breath-hold averaging (MBA) method for increased SNR in abdominal MRI. Magn Reson Med 34:905\u2013909. https:\/\/doi.org\/10.1002\/mrm.1910340617","journal-title":"Magn Reson Med"},{"key":"5063_CR19","doi-asserted-by":"publisher","first-page":"e63016","DOI":"10.7759\/cureus.63016","volume":"16","author":"AP Varghese","year":"2024","unstructured":"Varghese AP, Naik S, Asrar Up Haq Andrabi S, Luharia A, Tivaskar S (2024) Enhancing radiological diagnosis: a comprehensive review of image quality assessment and optimization strategies. Cureus 16:e63016. https:\/\/doi.org\/10.7759\/cureus.63016","journal-title":"Cureus"}],"container-title":["Abdominal Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-025-05063-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00261-025-05063-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00261-025-05063-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T06:04:01Z","timestamp":1769148241000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00261-025-05063-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,27]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1]]}},"alternative-id":["5063"],"URL":"https:\/\/doi.org\/10.1007\/s00261-025-05063-y","relation":{},"ISSN":["2366-0058"],"issn-type":[{"value":"2366-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,27]]},"assertion":[{"value":"4 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 June 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}