{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T21:08:33Z","timestamp":1780088913735,"version":"3.54.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2005,11,8]],"date-time":"2005-11-08T00:00:00Z","timestamp":1131408000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICO"],"published-print":{"date-parts":[[2006,2]]},"DOI":"10.1007\/s00264-005-0021-7","type":"journal-article","created":{"date-parts":[[2005,11,10]],"date-time":"2005-11-10T09:35:56Z","timestamp":1131615356000},"page":"31-34","source":"Crossref","is-referenced-by-count":11,"title":["Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up)"],"prefix":"10.1007","volume":"30","author":[{"given":"Sachin","family":"Badhe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Livesley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,11,8]]},"reference":[{"key":"21_CR1","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s00264-002-0410-0","volume":"27","author":"MS Ali","year":"2003","unstructured":"Ali MS, Kumar A (2003) Hydroxiapatite coated RM cup in primary hip arthroplasty 27:90\u201393","journal-title":"Int Orthop"},{"key":"21_CR2","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1016\/S0883-5403(98)80010-7","volume":"6","author":"CG Araujo","year":"1998","unstructured":"Araujo CG, Gonzales FJ, Tonino A (1998) International ABG study group. Rheumatoid Arthritis and hydroxyapatite coated hip prosthesis: five year results. J Arthroplasty 6:660\u2013667","journal-title":"J Arthroplasty"},{"issue":"3","key":"21_CR3","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1080\/00016470410001204","volume":"75","author":"J Blacha","year":"2004","unstructured":"Blacha J (2004) High Osteolysis and revision rate with hydroxyapatite coated ABG hip prosthesis. 65 hips in 56 patients followed for 6\u20139 years. Acta Orthop Scand 75(3):276\u2013282","journal-title":"Acta Orthop Scand"},{"key":"21_CR4","doi-asserted-by":"crossref","first-page":"760","DOI":"10.2106\/00004623-199505000-00012","volume":"77","author":"JD Bruijn","year":"1995","unstructured":"Bruijn JD, Seelen RM, Feenstra RM, Hansen BE, Bernoski FP (1995) Failure of Mecring screw-ring acetabular component in total hip arthroplasty. A 3 to 7-year follow-up study. J Bone Joint Surg Am 77:760\u2013766","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR5","first-page":"20","volume":"121","author":"JG DeLee","year":"1976","unstructured":"DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20\u201332","journal-title":"Clin Orthop"},{"key":"21_CR6","first-page":"36","volume":"86","author":"P Duffy","year":"2004","unstructured":"Duffy P, Sher JL, Partington PF (2004) Premature wear and Osteolysis in HA coated uncemented total hip arthroplasty. J Bone Joint Surg Br 86:36\u201338","journal-title":"J Bone Joint Surg Br"},{"key":"21_CR7","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s00264-004-0546-1","volume":"28","author":"EffenbergerH Ramsaver","year":"2004","unstructured":"Effenberger H Ramsaver T, Dorn U, Imhof M (2004) Factors influencing the revision rate of Zweymuller acetabular cup. Int Orthop 28:155\u2013158","journal-title":"Int Orthop"},{"key":"21_CR8","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s002640050178","volume":"21","author":"J Fernandez-Gonzalez","year":"1997","unstructured":"Fernandez-Gonzalez J, Canosa Sevillano R, Garcia Araujo C (1997) Cementless total hip arthroplasty with threaded cup. Int Orthop 21:327\u2013331","journal-title":"Int Orthop"},{"key":"21_CR9","first-page":"343","volume":"70","author":"J Gallo","year":"2003","unstructured":"Gallo J, Kaminek P, Zapletalova J (2003) Early failure of polyethylene liner in ABG I total hip prosthesis. Acta Chir Orthop Traumatol Cech 70:343\u2013349","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"21_CR10","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1054\/arth.2002.29394","volume":"17","author":"KA Giannikas","year":"2002","unstructured":"Giannikas KA, Din R, Sadiq S, Dunningham TH (2002) Medium term results of ABG total hip arthroplasty in young patients. J Arthroplasty 17:184\u2013188","journal-title":"J Arthroplasty"},{"key":"21_CR11","first-page":"17","volume":"141","author":"TA Gruen","year":"1979","unstructured":"Gruen TA, McNeice GM, Amstutz HC (1979) \"Modes of failure\" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17\u201327","journal-title":"Clin Orthop"},{"key":"21_CR12","doi-asserted-by":"crossref","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","volume":"51","author":"WH Harris","year":"1969","unstructured":"Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures. Treatment by mould arthroplasty. J Bone Joint Surg Am 51:737\u2013755","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR13","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2106\/00004623-199301000-00011","volume":"75","author":"RD Heekin","year":"1993","unstructured":"Heekin RD, Callaghan JJ, Hopkinson WJ (1993) The porous coated anatomic total hip prosthesis inserted without cement. J Bone Joint Surg Am 75:77\u201391","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR14","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1148\/radiology.148.3.6878678","volume":"148","author":"RW Hendrix","year":"1983","unstructured":"Hendrix RW, Wixon RL, Rana NA, Rogers LF (1983) Arthrography after total hip arthroplasty. A modified technique used in the diagnosis of pain. Radiology 148:647\u2013652","journal-title":"Radiology"},{"key":"21_CR15","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1007\/s002640050032","volume":"20","author":"D Hernandez-Vasquero","year":"1996","unstructured":"Hernandez-Vaquero D, Suarez Vazquez A, Fernandez-Corona C, Menendez-Vinvela G, Alegre-Matio R, Garcia-Sandoval MA (1996) Loosening of threaded acetabular cups in arthroplasty of the hip. The association with different types of coxarthrosis. Int Orthop 20:70\u201374","journal-title":"Int Orthop"},{"key":"21_CR16","doi-asserted-by":"crossref","first-page":"161","DOI":"10.2106\/00004623-199072020-00002","volume":"72","author":"RC Johnston","year":"1990","unstructured":"Johnston RC, Fitzgerald RH, Harris WH (1990) Clinical and Radiological evaluation of total hip replacement. J Bone Joint Surg Am 72:161\u2013168","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR17","doi-asserted-by":"crossref","first-page":"554","DOI":"10.2106\/00004623-199304000-00010","volume":"75","author":"JM Martell","year":"1993","unstructured":"Martell JM, Pierson RH 3rd, Jacobs JJ (1993) Primary total hip reconstruction with titanium fibre coated prosthesis inserted without cement. J Bone Joint Surg Am 75:554\u2013571","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR18","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.2106\/00004623-200012000-00004","volume":"82","author":"H Mckellop","year":"2000","unstructured":"Mckellop H, Shen FW, Lu B, Campbell P, Salovey R (2000) Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg Am 82:1708\u20131725","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR19","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1302\/0301-620X.76B2.8113287","volume":"76","author":"TD Owen","year":"1994","unstructured":"Owen TD, Moran CG, Smith SR, Pinder IM (1994) Results of uncemented porous-coated anatomic total hip replacement. J Bone Joint Surg Br 76:258\u2013262","journal-title":"J Bone Joint Surg Br"},{"key":"21_CR20","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/S0883-5403(03)00208-0","volume":"18","author":"A Rogers","year":"2003","unstructured":"Rogers A, Kulkarni R, Downes EM (2003) The ABG hydroxyapatite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up. J Arthroplasty 18:619\u2013625","journal-title":"J Arthroplasty"},{"key":"21_CR21","first-page":"85","volume":"319","author":"E Salvati","year":"1995","unstructured":"Salvati E, Lieberman J, Huko, Evans B (1995) Complications of femoral and acetabular modularity. Clin Orthop Relat Res 319:85\u201393","journal-title":"Clin Orthop Relat Res"},{"key":"21_CR22","doi-asserted-by":"crossref","first-page":"677","DOI":"10.2106\/00004623-199405000-00008","volume":"76","author":"TP Schmalzried","year":"1994","unstructured":"Schmalzried TP, Guttmann D, Grecula M, Amstutz HC (1994) The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 76:677\u2013688","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR23","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/00003086-200012000-00005","volume":"381","author":"T Schmalzried","year":"2000","unstructured":"Schmalzried T, Shepherd EF, Dorey FJ (2000) The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res 381:36\u201346","journal-title":"Clin Orthop Relat Res"},{"key":"21_CR24","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1302\/0301-620X.79B3.6630","volume":"79","author":"CH Shih","year":"1997","unstructured":"Shih CH, Lee PC, Chen JH (1997) Measurement of polyethylene wear in cementless total hip arthroplasty. J Bone Joint Surg Br 79:361\u2013365","journal-title":"J Bone Joint Surg Br"},{"key":"21_CR25","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1007\/s002640100265","volume":"25","author":"DD Spicer","year":"2001","unstructured":"Spicer DD, Scharper LA, Pomeroy DL, Badenhausen We Jr, Curry JI, Suthers KE, Smith MW (2001) Cementless cup fixation in total hip arthroplasty after 5\u20138 years. Int Orthop 25:286\u2013289","journal-title":"Int Orthop"},{"key":"21_CR26","doi-asserted-by":"crossref","first-page":"169","DOI":"10.2106\/00004623-199702000-00002","volume":"79","author":"GS Tompkins","year":"1997","unstructured":"Tompkins GS, Jacobs JJ, Kull LR (1997) Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-ten-year results. J Bone Joint Surg Am 79:169\u2013176","journal-title":"J Bone Joint Surg Am"},{"key":"21_CR27","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/S0883-5403(00)90486-8","volume":"15","author":"AJ Tonino","year":"2000","unstructured":"Tonino AJ, Rahmy AI (2000) The hydroxyapatite\u2013ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group. J Arthroplasty 15:274\u2013282","journal-title":"J Arthroplasty"},{"key":"21_CR28","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1080\/00016470410001213","volume":"75","author":"T Schewelow Von","year":"2004","unstructured":"Von Schewelow T, Sanzen L, Onsten I, Carlsson A (2004) Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis: an analysis of 154 omnifit prostheses with mean 6-year followup. Acta Orthop Scand 75:283\u2013294","journal-title":"Acta Orthop Scand"},{"issue":"Suppl 1","key":"21_CR29","first-page":"S16","volume":"27","author":"JM Wilkinson","year":"2003","unstructured":"Wilkinson JM, Gordan A, Stockley I (2003) Experiences with the Plasmacup\u2014early stability, wear, remodelling and outcome. Int Orthop 27 (Suppl 1):16\u201319","journal-title":"Int Orthop"},{"key":"21_CR30","doi-asserted-by":"crossref","first-page":"432","DOI":"10.2106\/00004623-199503000-00013","volume":"77","author":"B Zicat","year":"1995","unstructured":"Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:432\u2013439","journal-title":"J Bone Joint Surg Am"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-005-0021-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-005-0021-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-005-0021-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,10]],"date-time":"2020-04-10T19:41:03Z","timestamp":1586547663000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-005-0021-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11,8]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,2]]}},"alternative-id":["21"],"URL":"https:\/\/doi.org\/10.1007\/s00264-005-0021-7","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11,8]]}}}