{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T21:54:30Z","timestamp":1776376470867,"version":"3.51.2"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2008,12,17]],"date-time":"2008-12-17T00:00:00Z","timestamp":1229472000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2009,10]]},"DOI":"10.1007\/s00264-008-0713-x","type":"journal-article","created":{"date-parts":[[2008,12,16]],"date-time":"2008-12-16T10:13:38Z","timestamp":1229422418000},"page":"1415-1419","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of a new minimum contact locking plate and the limited contact dynamic compression plate in an osteoporotic fracture model","Comparaison entre une nouvelle minimum plaque de verrouillage de contact et une plaque dynamique de compression de contact limit\u00e9 dans un mod\u00e8le de fracture d\u2019ost\u00e9oporose"],"prefix":"10.1007","volume":"33","author":[{"given":"Yan","family":"Xiong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yufeng","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ziming","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Quanyin","family":"Du","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weijun","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aimin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2008,12,17]]},"reference":[{"key":"713_CR1","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/00003086-198807000-00018","volume":"232","author":"SM Perren","year":"1988","unstructured":"Perren SM, Cordey J, Rahn BA et al (1988) Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not to stress protection? Clin Orthop Relat Res 232:139\u2013151","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl","key":"713_CR2","first-page":"1","volume":"22","author":"SM Perren","year":"1991","unstructured":"Perren SM (1991) The concept of biological plating using the limited contact dynamic compression plate (LC-DCP). Scientific background, design and application. Injury 22(Suppl):1\u201341","journal-title":"Injury"},{"key":"713_CR3","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/0267-6605(92)90054-W","volume":"9","author":"IG Turner","year":"1992","unstructured":"Turner IG, Rice GN (1992) Comparison of bone screw holding strength in healthy bovine and osteoporotic human cancellous bone. Clin Mater 9:105\u2013107","journal-title":"Clin Mater"},{"key":"713_CR4","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.13752","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84:1093\u20131110","journal-title":"J Bone Joint Surg Br"},{"key":"713_CR5","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1055\/s-0030-1248022","volume":"20","author":"RM Greiwe","year":"2007","unstructured":"Greiwe RM, Archdeacon MT (2007) Locking plate technology: current concepts. J Knee Surg 20:50\u201355","journal-title":"J Knee Surg"},{"key":"713_CR6","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","volume":"18","author":"KA Egol","year":"2004","unstructured":"Egol KA, Kubiak EN, Fulkerson E et al (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18:488\u2013493","journal-title":"J Orthop Trauma"},{"issue":"Suppl","key":"713_CR7","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0020-1383(01)00127-9","volume":"32","author":"R Frigg","year":"2001","unstructured":"Frigg R (2001) Locking compression plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator (PC-Fix). Injury 32(Suppl):63\u201366","journal-title":"Injury"},{"issue":"9","key":"713_CR8","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/01.bot.0000174033.30054.5f","volume":"19","author":"MJ Gardner","year":"2005","unstructured":"Gardner MJ, Brophy RH, Campbell D et al (2005) The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model. J Orthop Trauma 19(9):597\u2013603","journal-title":"J Orthop Trauma"},{"issue":"suppl 3","key":"713_CR9","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0020-1383(00)80029-7","volume":"31","author":"M Borgeaud","year":"2000","unstructured":"Borgeaud M, Cordey J, Leyvraz PE et al (2000) Mechanical analysis of the bone to plate interface of the LC-DCP and of the PC-FIX on human femora. Injury 31(suppl 3):29\u201336","journal-title":"Injury"},{"issue":"5","key":"713_CR10","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1302\/0301-620X.89B5.18504","volume":"89","author":"OC Thiele","year":"2007","unstructured":"Thiele OC, Eckhardt C, Linke B et al (2007) Factors affecting the stability of screws in human cortical osteoporotic bone: a cadaver study. J Bone Joint Surg Br 89(5):701\u2013705","journal-title":"J Bone Joint Surg Br"},{"issue":"Suppl 2","key":"713_CR11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.injury.2003.09.018","volume":"34","author":"SM Perren","year":"2003","unstructured":"Perren SM (2003) Backgrounds of the technology of internal fixators. Injury 34(Suppl 2):1\u20133","journal-title":"Injury"},{"issue":"3","key":"713_CR12","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1115\/1.2796022","volume":"118","author":"JR Chapman","year":"1996","unstructured":"Chapman JR, Harrington RM, Lee KM (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118(3):391\u2013398","journal-title":"J Biomech Eng"},{"issue":"10","key":"713_CR13","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1302\/0301-620X.88B10.17683","volume":"88","author":"PV Giannoudis","year":"2006","unstructured":"Giannoudis PV, Schneider E (2006) Principles of fixation of osteoporotic fractures. J Bone Joint Surg Br 88(10):1272\u20131278","journal-title":"J Bone Joint Surg Br"},{"key":"713_CR14","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/00005373-198102000-00001","volume":"21","author":"RR Jacobs","year":"1981","unstructured":"Jacobs RR, Rahn BA, Perren SM (1981) Effects of plates on cortical bone perfusion. J Trauma 21:91\u201395","journal-title":"J Trauma"},{"key":"713_CR15","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.2106\/00004623-199410000-00010","volume":"76","author":"HK Uhthoff","year":"1994","unstructured":"Uhthoff HK, Boisvert D, Finnegan M (1994) Cortical porosis under plates. Reaction to unloading or to necrosis? J Bone Joint Surg Am 76:1507\u20131512","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl 3","key":"713_CR16","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S0020-1383(00)80030-3","volume":"31","author":"E Gautier","year":"2000","unstructured":"Gautier E, Perren SM, Cordey J (2000) Strain distribution in plated and unplated sheep tibia an in vivo experiment. Injury 31(Suppl 3):37\u201344","journal-title":"Injury"},{"key":"713_CR17","first-page":"559","volume":"93","author":"W Arnold","year":"1990","unstructured":"Arnold W (1990) Initial clinical experiences with the cervical spine titanium locking plate. Unfallchirurg 93:559\u2013561","journal-title":"Unfallchirurg"},{"key":"713_CR18","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/0278-2391(91)90145-C","volume":"49","author":"AL S\u00f6derholm","year":"1991","unstructured":"S\u00f6derholm AL, Lindqvist C, Skutnabb K et al (1991) Bridging of mandibular defects with two different reconstruction systems: an experimental study. J Oral Maxillofac Surg 49:1098\u20131105","journal-title":"J Oral Maxillofac Surg"},{"issue":"10","key":"713_CR19","doi-asserted-by":"crossref","first-page":"2298","DOI":"10.2106\/00004623-200710000-00028","volume":"89","author":"WR Smith","year":"2007","unstructured":"Smith WR, Ziran BH, Anglen JO et al (2007) Locking plates: tips and tricks. J Bone Joint Surg Am 89(10):2298\u20132307","journal-title":"J Bone Joint Surg Am"},{"issue":"suppl 3","key":"713_CR20","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/S0020-1383(00)80028-5","volume":"31","author":"J Cordey","year":"2000","unstructured":"Cordey J, Borgeaud M, Perren SM (2000) Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury 31(suppl 3):21\u201328","journal-title":"Injury"},{"issue":"2","key":"713_CR21","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1097\/BOT.0b013e318160c84c","volume":"22","author":"M Snow","year":"2008","unstructured":"Snow M, Thompson G, Turner PG (2008) A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model. J Orthop Trauma 22(2):121\u2013125","journal-title":"J Orthop Trauma"},{"issue":"suppl 3","key":"713_CR22","first-page":"1","volume":"31","author":"J Cordey","year":"2000","unstructured":"Cordey J, Perren SM, Steinemann SG (2000) Stress protection due to plates: myth or reality? A parametric analysis made using the composite beam theory. Injury 31(suppl 3):1\u201313","journal-title":"Injury"},{"issue":"suppl 2","key":"713_CR23","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/S0020-1383(01)00124-3","volume":"32","author":"H Eijer","year":"2001","unstructured":"Eijer H, Hauke C, Arens S et al (2001) PC-Fix and local infection resistance influence of implant design on postoperative infection development, clinical and experimental results. Injury 32(suppl 2):38\u201343","journal-title":"Injury"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.springerlink.com\/index\/pdf\/10.1007\/s00264-008-0713-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,22]],"date-time":"2023-05-22T23:37:04Z","timestamp":1684798624000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-008-0713-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12,17]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["713"],"URL":"https:\/\/doi.org\/10.1007\/s00264-008-0713-x","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,12,17]]}}}