{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:16:42Z","timestamp":1791825402170,"version":"4.3.4"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2009,2,13]],"date-time":"2009-02-13T00:00:00Z","timestamp":1234483200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2010,1]]},"DOI":"10.1007\/s00264-009-0731-3","type":"journal-article","created":{"date-parts":[[2009,2,12]],"date-time":"2009-02-12T14:44:00Z","timestamp":1234449840000},"page":"19-26","source":"Crossref","is-referenced-by-count":74,"title":["Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty"],"prefix":"10.1007","volume":"34","author":[{"given":"Jiri","family":"Gallo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vitezslav","family":"Havranek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jana","family":"Zapletalova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,2,13]]},"reference":[{"key":"731_CR1","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/BLO.0b013e3180320ae8","volume":"458","author":"AD Pearle","year":"2007","unstructured":"Pearle AD, Crow MK, Rakshit DS, Wohlgemuth J, Nestor BJ (2007) Distinct inflammatory gene pathways induced by particles. Clin Orthop Relat Res 458:194\u2013201","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR2","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1038\/ncprheum0428","volume":"3","author":"P Drees","year":"2007","unstructured":"Drees P, Eckardt A, Gay RE, Gay S, Huber LC (2007) Mechanisms of disease: molecular insights into aseptic loosening of orthopedic implants. Nat Clin Pract Rheumatol 3:165\u2013171","journal-title":"Nat Clin Pract Rheumatol"},{"key":"731_CR3","doi-asserted-by":"crossref","first-page":"5049","DOI":"10.1016\/j.biomaterials.2007.07.040","volume":"28","author":"HA McKellop","year":"2007","unstructured":"McKellop HA (2007) The lexicon of polyethylene wear in artificial joints. Biomaterials 28:5049\u20135057","journal-title":"Biomaterials"},{"key":"731_CR4","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/01.blo.0000150112.34736.82","volume":"429","author":"RH Hopper Jr","year":"2004","unstructured":"Hopper RH Jr, Engh CA Jr, Fowlkes LB, Engh CA (2004) The pros and cons of polyethylene sterilization with gamma irradiation. Clin Orthop Relat Res 429:54\u201362","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR5","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.2106\/00004623-199808000-00018","volume":"80","author":"TP Schmalzried","year":"1998","unstructured":"Schmalzried TP, Dorey FJ, McKellop H (1998) The multifactorial nature of polyethylene wear in vivo. J Bone Joint Surg Am 80:1234\u20131242","journal-title":"J Bone Joint Surg Am"},{"key":"731_CR6","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/00003086-200012000-00005","volume":"381","author":"TP Schmalzried","year":"2000","unstructured":"Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M et al (2000) The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res 381:36\u201346","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR7","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1302\/0301-620X.86B4.14249","volume":"86","author":"BM Wroblewski","year":"2004","unstructured":"Wroblewski BM, Siney PD, Fleming PA (2004) Wear of the cup in the Charnley LFA in the young patient. J Bone Joint Surg Br 86:498\u2013503","journal-title":"J Bone Joint Surg Br"},{"key":"731_CR8","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.arth.2007.06.008","volume":"23","author":"Z Wan","year":"2008","unstructured":"Wan Z, Boutary M, Dorr LD (2008) The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty 23:51\u201356","journal-title":"J Arthroplasty"},{"key":"731_CR9","doi-asserted-by":"crossref","first-page":"135","DOI":"10.5507\/bp.2006.021","volume":"150","author":"J Gallo","year":"2006","unstructured":"Gallo J, Havranek V, Cechova I, Zapletalova J (2006) Influence of demographic, surgical and implant variables on wear rate and osteolysis in ABG I hip arthroplasty. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 150:135\u2013141","journal-title":"Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub"},{"key":"731_CR10","doi-asserted-by":"crossref","first-page":"163","DOI":"10.5507\/bp.2008.027","volume":"152","author":"J Gallo","year":"2008","unstructured":"Gallo J, Langova K, Havranek V, Cechova I (2008) Poor survival of ABG I hip prosthesis in younger patients. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 152:163\u2013168","journal-title":"Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub"},{"key":"731_CR11","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1080\/00016470412331294365","volume":"75","author":"CJ Oosterbos","year":"2004","unstructured":"Oosterbos CJ, Rahmy AI, Tonino AJ, Witpeerd W (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10\u00a0years. Acta Orthop Scand 75:127\u2013133","journal-title":"Acta Orthop Scand"},{"key":"731_CR12","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1016\/S0883-5403(98)80010-7","volume":"13","author":"C Garcia Araujo","year":"1998","unstructured":"Garcia Araujo C, Fernandez Gonzalez J, Tonino A (1998) Rheumatoid arthritis and hydroxyapatite-coated hip prostheses: five-year results. International ABG Study Group. J Arthroplasty 13:660\u2013667","journal-title":"J Arthroplasty"},{"key":"731_CR13","first-page":"98","volume":"310","author":"P Rossi","year":"1995","unstructured":"Rossi P, Sibelli P, Fumero S, Crua E (1995) Short-term results of hydroxyapatite-coated primary total hip arthroplasty. Clin Orthop Relat Res 310:98\u2013102","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR14","first-page":"333","volume":"48","author":"J Gallo","year":"2003","unstructured":"Gallo J, Havranek V, Hrabovsky M (2003) Measurement of retrieved polyethylene cup by universal microscope. Fine Mech Opt 48:333\u2013338 (in Czech)","journal-title":"Fine Mech Opt"},{"key":"731_CR15","doi-asserted-by":"crossref","first-page":"28","DOI":"10.55095\/achot2006\/005","volume":"73","author":"J Gallo","year":"2006","unstructured":"Gallo J, Havranek V, Zapletalova J, Mandat D (2006) Measurement of acetabular polyethylene wear of total hip replacement, using a universal measuring microscope. Characteristics of measurements. Acta Chir Orthop Traumatol Cech 73:28\u201333 (in Czech)","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"731_CR16","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1302\/0301-620X.54B1.61","volume":"54","author":"J Charnley","year":"1972","unstructured":"Charnley J (1972) The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br 54:61\u201376","journal-title":"J Bone Joint Surg Br"},{"key":"731_CR17","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.2106\/00004623-199607000-00004","volume":"78","author":"W Pagnano","year":"1996","unstructured":"Pagnano W, Hanssen AD, Lewallen DG, Shaughnessy WJ (1996) The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty. J Bone Joint Surg Am 78:1004\u20131014","journal-title":"J Bone Joint Surg Am"},{"key":"731_CR18","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.2106\/00004623-200107000-00009","volume":"83","author":"KJ Saleh","year":"2001","unstructured":"Saleh KJ, Holtzman J, Gafni A, Saleh L, Davis A et al (2001) Reliability and intraoperative validity of preoperative assessment of standardized plain radiographs in predicting bone loss at revision hip surgery. J Bone Joint Surg Am 83:1040\u20131046","journal-title":"J Bone Joint Surg Am"},{"key":"731_CR19","doi-asserted-by":"crossref","first-page":"3451","DOI":"10.1002\/sim.1930","volume":"23","author":"D Wang","year":"2004","unstructured":"Wang D, Zhang W, Bakhai A (2004) Comparison of Bayesian model averaging and stepwise methods for model selection in logistic regression. Stat Med 23:3451\u20133467","journal-title":"Stat Med"},{"key":"731_CR20","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/00003086-199311000-00026","volume":"296","author":"T Karachalios","year":"1993","unstructured":"Karachalios T, Hartofilakidis G, Zacharakis N, Tsekoura M (1993) A 12- to 18-year radiographic follow-up study of Charnley low-friction arthroplasty. The role of the center of rotation. Clin Orthop Relat Res 296:140\u2013147","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR21","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/j.orthres.2004.11.005","volume":"23","author":"JM Wilkinson","year":"2005","unstructured":"Wilkinson JM, Hamer AJ, Stockley I, Eastell R (2005) Polyethylene wear rate and osteolysis: critical threshold versus continuous dose-response relationship. J Orthop Res 23:520\u2013525","journal-title":"J Orthop Res"},{"key":"731_CR22","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1054\/arth.2003.50023","volume":"18","author":"KF Orishimo","year":"2003","unstructured":"Orishimo KF, Sychterz CJ, Hopper RH Jr, Engh CA (2003) Can component and patient factors account for the variance in wear rates among bilateral total hip arthroplasty patients? J Arthroplasty 18:154\u2013160","journal-title":"J Arthroplasty"},{"key":"731_CR23","doi-asserted-by":"crossref","first-page":"639","DOI":"10.2106\/00004623-197961050-00001","volume":"61","author":"RC Johnston","year":"1979","unstructured":"Johnston RC, Brand RA, Crowninshield RD (1979) Reconstruction of the hip. A mathematical approach to determine optimum geometric relationships. J Bone Joint Surg Am 61:639\u2013652","journal-title":"J Bone Joint Surg Am"},{"key":"731_CR24","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/00003086-200107000-00020","volume":"388","author":"K Hirakawa","year":"2001","unstructured":"Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y et al (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res 388:135\u2013142","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl 4","key":"731_CR25","doi-asserted-by":"crossref","first-page":"56","DOI":"10.2106\/00004623-200300004-00007","volume":"85","author":"S Patil","year":"2003","unstructured":"Patil S, Bergula A, Chen PC, Colwell CW Jr, D\u2019Lima DD (2003) Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am 85(Suppl 4):56\u201363","journal-title":"J Bone Joint Surg Am"},{"key":"731_CR26","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/S0883-5403(98)80003-X","volume":"13","author":"H Del Schutte Jr","year":"1998","unstructured":"Del Schutte H Jr, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D et al (1998) Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty 13:621\u2013626","journal-title":"J Arthroplasty"},{"key":"731_CR27","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1023\/A:1008970027306","volume":"12","author":"JE Nevelos","year":"2001","unstructured":"Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J (2001) The influence of acetabular cup angle on the wear of \"BIOLOX Forte\" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 12:141\u2013144","journal-title":"J Mater Sci Mater Med"},{"key":"731_CR28","doi-asserted-by":"crossref","first-page":"65","DOI":"10.3928\/0147-7447-20020101-18","volume":"25","author":"M Kligman","year":"2002","unstructured":"Kligman M, Michael H, Roffman M (2002) The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wear. Orthopedics 25:65\u201367","journal-title":"Orthopedics"},{"key":"731_CR29","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/01.blo.0000096802.78689.45","volume":"417","author":"G Digas","year":"2003","unstructured":"Digas G, Karrholm J, Thanner J, Malchau H, Herberts P (2003) Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips. Clin Orthop Relat Res 417:126\u2013138","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR30","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1302\/0301-620X.89B2.18158","volume":"89","author":"GS Chuter","year":"2007","unstructured":"Chuter GS, Cloke DJ, Mahomed A, Partington PF, Green SM (2007) Wear analysis of failed acetabular polyethylene: a comparison of analytical methods. J Bone Joint Surg Br 89:273\u2013279","journal-title":"J Bone Joint Surg Br"},{"key":"731_CR31","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/S0966-6362(01)00097-2","volume":"13","author":"MR Pierrynowski","year":"2001","unstructured":"Pierrynowski MR, Galea V (2001) Enhancing the ability of gait analyses to differentiate between groups: scaling gait data to body size. Gait Posture 13:193\u2013201","journal-title":"Gait Posture"},{"key":"731_CR32","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1243\/095441104322983997","volume":"218","author":"K Vassiliou","year":"2004","unstructured":"Vassiliou K, Unsworth A (2004) Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts? Proc Inst Mech Eng Part H-J Eng Med 218:101\u2013107","journal-title":"Proc Inst Mech Eng Part H-J Eng Med"},{"key":"731_CR33","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.cuor.2005.09.005","volume":"20","author":"ZM Jin","year":"2006","unstructured":"Jin ZM, Stone M, Ingham E, Fisher J (2006) Biotribology. Curr Orthop 20:32\u201340","journal-title":"Curr Orthop"},{"key":"731_CR34","first-page":"131","volume":"54","author":"MN Charles","year":"2005","unstructured":"Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF et al (2005) Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect 54:131\u2013141","journal-title":"Instr Course Lect"},{"key":"731_CR35","doi-asserted-by":"crossref","unstructured":"Bicanic G, Delimar D, Delimar M, Pecina M (2008) Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasia. Int Orthop (in press). doi: 10.1007\/s00264-008-0683-z","DOI":"10.1007\/s00264-008-0683-z"},{"key":"731_CR36","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/00003086-200107000-00019","volume":"388","author":"DP Sakalkale","year":"2001","unstructured":"Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH (2001) Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res 388:125\u2013134","journal-title":"Clin Orthop Relat Res"},{"key":"731_CR37","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1002\/jor.20224","volume":"24","author":"C Roder","year":"2006","unstructured":"Roder C, Staub LP, Eichler P, Widmer M, Dietrich D et al (2006) Avoiding misclassification bias with the traditional Charnley classification: rationale for a fourth Charnley class BB. J Orthop Res 24:1803\u20131808","journal-title":"J Orthop Res"},{"key":"731_CR38","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1054\/arth.2002.33664","volume":"17","author":"JH Dumbleton","year":"2002","unstructured":"Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649\u2013661","journal-title":"J Arthroplasty"},{"key":"731_CR39","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1007\/s00264-006-0075-1","volume":"30","author":"WY Kim","year":"2006","unstructured":"Kim WY, Muddu BN (2006) Eleven-year results of the ABG I hip replacement. Int Orthop 30:182\u2013184","journal-title":"Int Orthop"},{"key":"731_CR40","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1080\/00016470410001204","volume":"75","author":"J Blacha","year":"2004","unstructured":"Blacha J (2004) High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses: 65 hips in 56 young patients followed for 5\u20139\u00a0years. Acta Orthop Scand 75:276\u2013282","journal-title":"Acta Orthop Scand"},{"key":"731_CR41","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1007\/s00402-006-0168-8","volume":"126","author":"KS Delank","year":"2006","unstructured":"Delank KS, Drees P, Menzel N, Hansen T, Duschner H et al (2006) Increased polyethylene wear after cementless ABG I total hip arthroplasty. Arch Orthop Trauma Surg 126:509\u2013516","journal-title":"Arch Orthop Trauma Surg"},{"key":"731_CR42","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s00264-005-0021-7","volume":"30","author":"S Badhe","year":"2006","unstructured":"Badhe S, Livesley P (2006) Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up). Int Orthop 30:31\u201334","journal-title":"Int Orthop"},{"key":"731_CR43","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.arth.2006.05.022","volume":"22","author":"F Castoldi","year":"2007","unstructured":"Castoldi F, Rossi R, La Russa M, Sibelli P, Rossi P et al (2007) Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty. J Arthroplasty 22:363\u2013368","journal-title":"J Arthroplasty"},{"key":"731_CR44","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1007\/s00264-005-0065-8","volume":"30","author":"V Canales Cortes","year":"2006","unstructured":"Canales Cortes V, Panisello Sebastia JJ, Herrera Rodriguez A, Peguero Bona A, Martinez Martin A et al (2006) Ten-year follow-up of an anatomical hydroxyapatite-coated total hip prosthesis. Int Orthop 30:84\u201390","journal-title":"Int Orthop"},{"key":"731_CR45","first-page":"177","volume":"12","author":"J Ingram","year":"2002","unstructured":"Ingram J, Matthews JB, Tipper J, Stone M, Fisher J et al (2002) Comparison of the biological activity of grade GUR 1120 and GUR 415HP UHMWPE wear debris. Bio-Med Mater Eng 12:177\u2013188","journal-title":"Bio-Med Mater Eng"},{"key":"731_CR46","doi-asserted-by":"crossref","first-page":"815","DOI":"10.2106\/JBJS.D.02111","volume":"87","author":"SM Kurtz","year":"2005","unstructured":"Kurtz SM, Rimnac CM, Hozack WJ, Turner J, Marcolongo M et al (2005) In vivo degradation of polyethylene liners after gamma sterilization in air. J Bone Joint Surg Am 87:815\u2013823","journal-title":"J Bone Joint Surg Am"},{"key":"731_CR47","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.arth.2004.11.003","volume":"20","author":"SM Kurtz","year":"2005","unstructured":"Kurtz SM, Harrigan TP, Herr M, Manley MT (2005) An in vitro model for fluid pressurization of screw holes in metal-backed total joint components. J Arthroplasty 20:932\u2013938","journal-title":"J Arthroplasty"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-009-0731-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-009-0731-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-009-0731-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,10]],"date-time":"2024-03-10T13:52:26Z","timestamp":1710078746000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-009-0731-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,2,13]]},"references-count":47,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["731"],"URL":"https:\/\/doi.org\/10.1007\/s00264-009-0731-3","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2,13]]}}}