{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T16:31:37Z","timestamp":1770136297857,"version":"3.49.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2012,4,4]],"date-time":"2012-04-04T00:00:00Z","timestamp":1333497600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2012,9]]},"DOI":"10.1007\/s00264-012-1532-7","type":"journal-article","created":{"date-parts":[[2012,4,3]],"date-time":"2012-04-03T02:28:43Z","timestamp":1333420123000},"page":"1767-1772","source":"Crossref","is-referenced-by-count":39,"title":["The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty"],"prefix":"10.1007","volume":"36","author":[{"given":"Florian","family":"Schmidutz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arnd","family":"Steinbr\u00fcck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenz","family":"Wanke-Jellinek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Pietschmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Volkmar","family":"Jansson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Fottner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,4,4]]},"reference":[{"issue":"3","key":"1532_CR1","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1302\/0301-620X.80B3.7764","volume":"80","author":"S Eggli","year":"1998","unstructured":"Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80(3):382\u2013390","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"1532_CR2","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0030-5898(05)70074-2","volume":"30","author":"FS Haddad","year":"1999","unstructured":"Haddad FS, Masri BA, Garbuz DS, Duncan CP (1999) The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am 30(2):191\u2013207","journal-title":"Orthop Clin North Am"},{"issue":"1","key":"1532_CR3","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1080\/00016470410001708070","volume":"75","author":"KT Suh","year":"2004","unstructured":"Suh KT, Cheon SJ, Kim DW (2004) Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 75(1):40\u201344","journal-title":"Acta Orthop Scand"},{"issue":"7","key":"1532_CR4","doi-asserted-by":"crossref","first-page":"455","DOI":"10.5435\/00124635-200511000-00005","volume":"13","author":"AG Della Valle","year":"2005","unstructured":"Della Valle AG, Padgett DE, Salvati EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13(7):455\u2013462","journal-title":"J Am Acad Orthop Surg"},{"issue":"3","key":"1532_CR5","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s00264-006-0317-2","volume":"32","author":"AG Della Valle","year":"2008","unstructured":"Della Valle AG, Comba F, Taveras N, Salvati EA (2008) The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop 32(3):289\u2013294","journal-title":"Int Orthop"},{"issue":"7","key":"1532_CR6","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1007\/s00402-010-1256-3","volume":"131","author":"A Fottner","year":"2011","unstructured":"Fottner A, Steinbruck A, Sadoghi P, Mazoochian F, Jansson V (2011) Digital comparison of planned and implanted stem position in total hip replacement using a program form migration analysis. Arch Orthop Trauma Surg 131(7):1013\u20131019","journal-title":"Arch Orthop Trauma Surg"},{"issue":"6","key":"1532_CR7","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1016\/j.arth.2006.07.013","volume":"22","author":"B The","year":"2007","unstructured":"The B, Verdonschot N, van Horn JR, van Ooijen PM, Diercks RL (2007) Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty 22(6):866\u2013870","journal-title":"J Arthroplasty"},{"issue":"5","key":"1532_CR8","first-page":"631","volume":"35","author":"X Zhao","year":"2011","unstructured":"Zhao X, Zhu ZA, Zhao J, Li MQ, Wang G, Yu DG, Yu B (2011) The utility of digital templating in total hip arthroplasty with Crowe type II and III dysplastic hips. IntOrthop 35(5):631\u2013638","journal-title":"IntOrthop"},{"issue":"8","key":"1532_CR9","first-page":"395","volume":"40","author":"DR Whiddon","year":"2011","unstructured":"Whiddon DR, Bono JV, Lang JE, Smith EL, Salyapongse AK (2011) Accuracy of digital templating in total hip arthroplasty. Am J Orthop (Belle Mead NJ) 40(8):395\u2013398","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"10","key":"1532_CR10","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1007\/s00402-007-0494-5","volume":"128","author":"C Wedemeyer","year":"2008","unstructured":"Wedemeyer C, Quitmann H, Xu J, Heep H, von Knoch M, Saxler G (2008) Digital templating in total hip arthroplasty with the Mayo stem. Arch Orthop Trauma Surg 128(10):1023\u20131029","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"1532_CR11","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.arth.2007.11.019","volume":"24","author":"R Iorio","year":"2009","unstructured":"Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24(2):175\u2013179","journal-title":"J Arthroplasty"},{"issue":"4","key":"1532_CR12","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.arth.2009.04.011","volume":"25","author":"P Gamble","year":"2010","unstructured":"Gamble P, de Beer J, Petruccelli D, Winemaker M (2010) The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty 25(4):529\u2013532","journal-title":"J Arthroplasty"},{"issue":"7","key":"1532_CR13","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1302\/0301-620X.82B7.10420","volume":"82","author":"BF Morrey","year":"2000","unstructured":"Morrey BF, Adams RA, Kessler M (2000) A conservative femoral replacement for total hip arthroplasty. A prospective study. J Bone Joint Surg Br 82(7):952\u2013958","journal-title":"J Bone Joint Surg Br"},{"issue":"12","key":"1532_CR14","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1007\/s00402-011-1350-1","volume":"131","author":"S Kamada","year":"2011","unstructured":"Kamada S, Naito M, Nakamura Y, Kiyama T (2011) Hip abductor muscle strength after total hip arthroplasty with short stems. Arch Orthop Trauma Surg 131(12):1723\u20131732","journal-title":"Arch Orthop Trauma Surg"},{"issue":"Suppl 2","key":"1532_CR15","doi-asserted-by":"crossref","first-page":"118","DOI":"10.2106\/00004623-200412002-00016","volume":"86-A","author":"JV Bono","year":"2004","unstructured":"Bono JV (2004) Digital templating in total hip arthroplasty. J Bone Joint Surg Am 86-A(Suppl 2):118\u2013122","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"1532_CR16","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159\u2013174","journal-title":"Biometrics"},{"issue":"5","key":"1532_CR17","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1007\/s00264-010-1020-x","volume":"35","author":"D Briem","year":"2011","unstructured":"Briem D, Schneider M, Bogner N, Botha N, Gebauer M, Gehrke T, Schwantes B (2011) Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesis. Int Orthop 35(5):655\u2013660","journal-title":"Int Orthop"},{"issue":"3","key":"1532_CR18","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1007\/s00264-011-1361-0","volume":"36","author":"M Lerch","year":"2012","unstructured":"Lerch M, von der Haar-Tran A, Windhagen H, Behrens BA, Wefstaedt P, Stukenborg-Colsman CM (2012) Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study. Int Orthop 36(3):533\u2013541","journal-title":"Int Orthop"},{"issue":"2","key":"1532_CR19","first-page":"e179","volume":"35","author":"AR Hsu","year":"2012","unstructured":"Hsu AR, Kim JD, Bhatia S, Levine BR (2012) Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty. Orthopedics 35(2):e179\u2013e183","journal-title":"Orthopedics"},{"issue":"4","key":"1532_CR20","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1007\/s11999-008-0486-y","volume":"467","author":"HJ Crooijmans","year":"2009","unstructured":"Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB (2009) A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res 467(4):909\u2013916","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"1532_CR21","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1007\/s00402-011-1342-1","volume":"131","author":"A Zeh","year":"2011","unstructured":"Zeh A, Radetzki F, Diers V, Bach D, Rollinghoff M, Delank KS (2011) Is there an increased stem migration or compromised osteointegration of the Mayo short-stemmed prosthesis following cerclage wiring of an intrasurgical periprosthetic fracture? Arch Orthop Trauma Surg 131(12):1717\u20131722","journal-title":"Arch Orthop Trauma Surg"},{"issue":"6","key":"1532_CR22","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1007\/s00402-008-0676-9","volume":"129","author":"E Jakubowitz","year":"2009","unstructured":"Jakubowitz E, Seeger JB, Lee C, Heisel C, Kretzer JP, Thomsen MN (2009) Do short-stemmed-prostheses induce periprosthetic fractures earlier than standard hip stems? A biomechanical ex-vivo study of two different stem designs. Arch Orthop Trauma Surg 129(6):849\u2013855","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"1532_CR23","doi-asserted-by":"crossref","first-page":"e144","DOI":"10.3928\/01477447-20120123-14","volume":"35","author":"F Mittag","year":"2012","unstructured":"Mittag F, Ipach I, Schaefer R, Meisner C, Leichtle U (2012) Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician. Orthopedics 35(2):e144\u2013e147","journal-title":"Orthopedics"},{"issue":"4","key":"1532_CR24","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/S0883-5403(05)80153-6","volume":"10","author":"LW Carter","year":"1995","unstructured":"Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10(4):507\u2013513","journal-title":"J Arthroplasty"},{"issue":"5","key":"1532_CR25","first-page":"616","volume":"77","author":"T Efe","year":"2011","unstructured":"Efe T, El Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J (2011) Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg 77(5):616\u2013621","journal-title":"Acta Orthop Belg"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-012-1532-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-012-1532-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-012-1532-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,11]],"date-time":"2022-01-11T22:14:43Z","timestamp":1641939283000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-012-1532-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4,4]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["1532"],"URL":"https:\/\/doi.org\/10.1007\/s00264-012-1532-7","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,4,4]]}}}