{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T23:07:33Z","timestamp":1782601653704,"version":"3.54.5"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2013,9,22]],"date-time":"2013-09-22T00:00:00Z","timestamp":1379808000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1007\/s00264-013-2101-4","type":"journal-article","created":{"date-parts":[[2013,9,21]],"date-time":"2013-09-21T05:25:15Z","timestamp":1379741115000},"page":"2421-2427","source":"Crossref","is-referenced-by-count":66,"title":["Comparison of anterior cervical fusion by titanium mesh cage versus nano-hydroxyapatite\/polyamide cage following single-level corpectomy"],"prefix":"10.1007","volume":"37","author":[{"given":"Xi","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Limin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yueming","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingquan","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiancheng","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youdi","family":"Xue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunpeng","family":"Ren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,9,22]]},"reference":[{"key":"2101_CR1","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/00003086-200201000-00004","volume":"394","author":"KM Malloy","year":"2002","unstructured":"Malloy KM, Hilibrand AS (2002) Autograft versus allograft in degenerative cervical disease. Clin Orthop Relat Res 394:27\u201338","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"2101_CR2","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1302\/0301-620X.85B7.13398","volume":"85","author":"AA Siddiqui","year":"2003","unstructured":"Siddiqui AA, Jackowski A (2003) Cage versus tricortical graft for cervical interbody fusion. A prospective randomised study. J Bone Joint Surg Br 85(7):1019\u20131025","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"2101_CR3","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1097\/00007632-200301150-00008","volume":"28","author":"JS Silber","year":"2003","unstructured":"Silber JS, Anderson DG, Daffner SD et al (2003) Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion. Spine (Phila Pa 1976) 28(2):134\u2013139","journal-title":"Spine (Phila Pa 1976)"},{"issue":"11","key":"2101_CR4","doi-asserted-by":"crossref","first-page":"1742","DOI":"10.2106\/00004623-199511000-00017","volume":"77","author":"WW Tomford","year":"1995","unstructured":"Tomford WW (1995) Transmission of disease through transplantation of musculoskeletal allografts. J Bone Joint Surg Am 77(11):1742\u20131754","journal-title":"J Bone Joint Surg Am"},{"key":"2101_CR5","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1097\/00007632-199107000-00006","volume":"(Phila Pa 1976)","author":"TA Zdeblick","year":"1991","unstructured":"Zdeblick TA, Ducker TB (1991) The use of freeze-dried allograft bone for anterior cervical fusions. Spine (Phila Pa 1976) 16:726\u2013729","journal-title":"Spine"},{"key":"2101_CR6","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/00003086-200201000-00006","volume":"394","author":"KD Riew","year":"2002","unstructured":"Riew KD, Rhee JM (2002) The use of titanium mesh cages in the cervical spine. Clin Orthop Relat Res 394:47\u201354","journal-title":"Clin Orthop Relat Res"},{"issue":"15","key":"2101_CR7","doi-asserted-by":"crossref","first-page":"1604","DOI":"10.1097\/00007632-199908010-00016","volume":"24","author":"ME Majd","year":"1999","unstructured":"Majd ME, Vadhva M, Holt RT (1999) Anterior cervical reconstruction using titanium cage with anterior plating. Spine (Phila Pa 1976) 24(15):1604\u20131610","journal-title":"Spine (Phila Pa 1976)"},{"issue":"18","key":"2101_CR8","doi-asserted-by":"crossref","first-page":"2407","DOI":"10.1097\/00007632-200009150-00023","volume":"25","author":"KR Eck","year":"2000","unstructured":"Eck KR, Bridwell KH, Ungacta FF et al (2000) Analysis of titanium mesh cages in adults with minimum two-year follow-up. Spine (Phila Pa 1976) 25(18):2407\u20132415","journal-title":"Spine (Phila Pa 1976)"},{"issue":"7","key":"2101_CR9","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1097\/BSD.0b013e318158de22","volume":"21","author":"Y Chen","year":"2008","unstructured":"Chen Y, Chen D, Guo Y et al (2008) Subsidence of titanium mesh cage: a study based on 300 cases. J Spinal Disord Tech 21(7):489\u2013492","journal-title":"J Spinal Disord Tech"},{"issue":"5","key":"2101_CR10","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1097\/BSD.0b013e3181b15bc8","volume":"23","author":"JF Chen","year":"2010","unstructured":"Chen JF, Lee ST, Wu CT (2010) A hollow cylindrical PMMA strut for cervical spine reconstruction after cervical multilevel corpectomy. J Spinal Disord Tech 23(5):321\u2013327","journal-title":"J Spinal Disord Tech"},{"issue":"5","key":"2101_CR11","doi-asserted-by":"crossref","first-page":"542","DOI":"10.3109\/02688697.2010.503819","volume":"24","author":"SM Kabir","year":"2010","unstructured":"Kabir SM, Alabi J, Rezajooi K et al (2010) Anterior cervical corpectomy: review and comparison of results using titanium mesh cages and carbon fibre reinforced polymer cages. Br J Neurosurg 24(5):542\u2013546","journal-title":"Br J Neurosurg"},{"issue":"1","key":"2101_CR12","doi-asserted-by":"crossref","first-page":"e66","DOI":"10.3928\/01477447-20111122-10","volume":"35","author":"X Yang","year":"2012","unstructured":"Yang X, Song Y, Liu L et al (2012) Anterior reconstruction with nano-hydroxyapatite\/polyamide-66 cage after thoracic and lumbar corpectomy. Orthopedics 35(1):e66\u2013e73","journal-title":"Orthopedics"},{"issue":"4","key":"2101_CR13","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.jocn.2011.05.043","volume":"19","author":"Z Zhao","year":"2012","unstructured":"Zhao Z, Jiang D, Ou Y et al (2012) A hollow cylindrical nano-hydroxyapatite\/polyamide composite strut for cervical reconstruction after cervical corpectomy. J Clin Neurosci 19(4):536\u2013540","journal-title":"J Clin Neurosci"},{"key":"2101_CR14","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1007\/s00586-006-0284-8","volume":"16","author":"P Barsa","year":"2007","unstructured":"Barsa P, Suchomel P (2007) Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion. Eur Spine J 16:1395\u20131400","journal-title":"Eur Spine J"},{"issue":"1 suppl","key":"2101_CR15","first-page":"3","volume":"99","author":"Z Dorai","year":"2003","unstructured":"Dorai Z, Morgan H, Coimbra C (2003) Titanium cage reconstruction after cervical corpectomy. J Neurosurg 99(1 suppl):3\u20137","journal-title":"J Neurosurg"},{"key":"2101_CR16","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/01.bsd.0000210113.09521.aa","volume":"19","author":"H Nakase","year":"2006","unstructured":"Nakase H, Park YS, Kimura H et al (2006) Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy. J Spinal Disord Tech 19:353\u2013357","journal-title":"J Spinal Disord Tech"},{"issue":"4","key":"2101_CR17","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.jocn.2011.06.029","volume":"19","author":"AE Castellvi","year":"2012","unstructured":"Castellvi AE, Castellvi A, Clabeaux DH (2012) Corpectomy with titanium cage reconstruction in the cervical spine. J Clin Neurosci 19(4):517\u2013521","journal-title":"J Clin Neurosci"},{"issue":"24","key":"2101_CR18","doi-asserted-by":"crossref","first-page":"4787","DOI":"10.1016\/S0142-9612(02)00229-6","volume":"23","author":"X Wang","year":"2002","unstructured":"Wang X, Li Y, Wei J et al (2002) Development of biomimetic nano- hydroxyapatite\/poly(hexamethyleneadipamide) composites. Biomaterials 23(24):4787\u20134791","journal-title":"Biomaterials"},{"issue":"7","key":"2101_CR19","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1023\/A:1024087410890","volume":"14","author":"M Huang","year":"2003","unstructured":"Huang M, Feng J, Wang J et al (2003) Synthesis and characterization of nano-HA\/PA66 composites. J Mater Sci Mater Med 14(7):655\u2013660","journal-title":"J Mater Sci Mater Med"},{"key":"2101_CR20","first-page":"331","volume":"5","author":"Q Xu","year":"2010","unstructured":"Xu Q, Lu H, Zhang J et al (2010) Tissue engineering scaffold material of porous nanohydroxyapatite\/polyamide 66. Int J Nanomedicine 5:331\u2013335","journal-title":"Int J Nanomedicine"},{"issue":"5","key":"2101_CR21","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/BSD.0b013e3181af3a84","volume":"23","author":"CC Niu","year":"2010","unstructured":"Niu CC, Liao JC, Chen WJ, Chen LH (2010) Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages. J Spinal Disord Tech 23(5):310\u2013316","journal-title":"J Spinal Disord Tech"},{"issue":"4","key":"2101_CR22","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1002\/jor.21566","volume":"30","author":"NR Ordway","year":"2010","unstructured":"Ordway NR, Rim BC, Tan R et al (2010) Anterior cervical interbody constructs: effect of a repetitive compressive force on the endplate. J Orthop Res 30(4):587\u2013592","journal-title":"J Orthop Res"},{"issue":"2 Suppl","key":"2101_CR23","first-page":"172","volume":"99","author":"PK Narotam","year":"2003","unstructured":"Narotam PK, Pauley SM, McGinn GJ (2003) Titanium mesh cages for cervical spine stabilization after corpectomy: a clinical and radiological study. J Neurosurg 99(2 Suppl):172\u2013180","journal-title":"J Neurosurg"},{"issue":"5","key":"2101_CR24","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.surneu.2005.12.021","volume":"65","author":"HC Chuang","year":"2006","unstructured":"Chuang HC, Cho DY, Chang CS et al (2006) Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy. Surg Neurol 65(5):464\u2013471","journal-title":"Surg Neurol"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-013-2101-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-013-2101-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-013-2101-4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,6]],"date-time":"2022-03-06T15:57:31Z","timestamp":1646582251000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-013-2101-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,22]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["2101"],"URL":"https:\/\/doi.org\/10.1007\/s00264-013-2101-4","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,22]]}}}