{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T12:45:48Z","timestamp":1787748348091,"version":"build-2784847793"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2013,10,5]],"date-time":"2013-10-05T00:00:00Z","timestamp":1380931200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1007\/s00264-013-2120-1","type":"journal-article","created":{"date-parts":[[2013,10,4]],"date-time":"2013-10-04T02:42:36Z","timestamp":1380854556000},"page":"2465-2473","source":"Crossref","is-referenced-by-count":57,"title":["A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures"],"prefix":"10.1007","volume":"37","author":[{"given":"Yanfeng","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunlin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,10,5]]},"reference":[{"key":"2120_CR1","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1243\/09544119JEIM799","volume":"224","author":"S Eberle","year":"2010","unstructured":"Eberle S, Gerber C, von Oldenburg G et al (2010) A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests. Proc Inst Mech Eng H 224:1141\u20131152","journal-title":"Proc Inst Mech Eng H"},{"key":"2120_CR2","doi-asserted-by":"crossref","first-page":"49","DOI":"10.4103\/0019-5413.38581","volume":"42","author":"NK Magu","year":"2008","unstructured":"Magu NK, Tater R, Rohilla R et al (2008) Functional outcome of modified Pauwels\u2019 intertrochanteric osteotomy and total hip arthroplasty in femoral neck fractures in elderly patients. Indian J Orthop 42:49\u201355","journal-title":"Indian J Orthop"},{"key":"2120_CR3","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1016\/j.injury.2006.06.008","volume":"37","author":"E Strauss","year":"2006","unstructured":"Strauss E, Frank J, Lee J et al (2006) Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury 37:984\u2013989","journal-title":"Injury"},{"key":"2120_CR4","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e31819211b2","volume":"23","author":"AH Ruecker","year":"2009","unstructured":"Ruecker AH, Rupprecht M, Gruber M et al (2009) The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression. J Orthop Trauma 23:22\u201330","journal-title":"J Orthop Trauma"},{"key":"2120_CR5","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s001980050003","volume":"11","author":"KM Fox","year":"2000","unstructured":"Fox KM, Magaziner J, Hawkes WG et al (2000) Loss of bone density and lean body mass after hip fracture. Osteoporos Int 11:31\u201335","journal-title":"Osteoporos Int"},{"key":"2120_CR6","first-page":"478","volume":"65","author":"JO Laursen","year":"1999","unstructured":"Laursen JO (1999) Treatment of intracapsular fractures of the femoral neck in Denmark: trends in indications over the past decade. Acta Orthop Belg 65:478\u2013484","journal-title":"Acta Orthop Belg"},{"key":"2120_CR7","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1080\/000164700317362235","volume":"71","author":"T Johansson","year":"2000","unstructured":"Johansson T, Jacobsson SA, Ivarsson I et al (2000) Internal fixation versus total hip arthroplasty in the treatment of displaced femoral neck fractures: a prospective randomized study of 100 hips. Acta Orthop Scand 71:597\u2013602","journal-title":"Acta Orthop Scand"},{"key":"2120_CR8","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1097\/TA.0b013e31820e86e6","volume":"71","author":"M Rupprecht","year":"2011","unstructured":"Rupprecht M, Grossterlinden L, Ruecker AH et al (2011) A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma 71:625\u2013634","journal-title":"J Trauma"},{"key":"2120_CR9","first-page":"937","volume":"34","author":"D Kristek","year":"2010","unstructured":"Kristek D, Lovri\u0107 I, Kristek J et al (2010) The proximal femoral nail antirotation (PFNA) in the treatment of proximal femoral fractures. Coll Antropol 34:937\u2013940","journal-title":"Coll Antropol"},{"key":"2120_CR10","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/j.injury.2010.03.020","volume":"41","author":"Y Liu","year":"2010","unstructured":"Liu Y, Tao R, Liu F et al (2010) Mid-term outcomes after intramedullary fixation of peritrochanteric femoral fractures using the new proximal femoral nail antirotation (PFNA). Injury 41:810\u2013817","journal-title":"Injury"},{"key":"2120_CR11","doi-asserted-by":"crossref","first-page":"127","DOI":"10.3944\/AOTT.2010.2237","volume":"44","author":"S Sahin","year":"2010","unstructured":"Sahin S, Ert\u00fcrer E, Ozt\u00fcrk I et al (2010) Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures. Acta Orthop Traumatol Turc 44:127\u2013134","journal-title":"Acta Orthop Traumatol Turc"},{"key":"2120_CR12","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1097\/00005373-200203000-00021","volume":"52","author":"TN Joseph","year":"2002","unstructured":"Joseph TN, Al C, Kummer FJ et al (2002) The effect of posterior say on the fixation stability of intertrochantic hip fractures. J Trauma 52:544\u2013547","journal-title":"J Trauma"},{"key":"2120_CR13","first-page":"361","volume":"57","author":"D Mellano","year":"2006","unstructured":"Mellano D, Grosso E, Tarello M et al (2006) Hip fractures: our experience in surgical treatment. Minerva Ortop Traumatol 57:361\u2013365","journal-title":"Minerva Ortop Traumatol"},{"key":"2120_CR14","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/S0020-1383(02)00054-2","volume":"33","author":"H Banan","year":"2002","unstructured":"Banan H, Al-Sabti A, Jimulia T et al (2002) The treatment of unstable, extracapsular hip fractures with the AO\/ASIF proximal femoral nail (PFN)\u2013our first 60 cases. Injury 33:401\u2013405","journal-title":"Injury"},{"key":"2120_CR15","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1007\/s00402-008-0736-1","volume":"128","author":"JH Hwang","year":"2008","unstructured":"Hwang JH, Oh JK, Han SH, Shon WY et al (2008) Mismatch between PFNa and medullary canal causing difficulty in nailing of the pertrochanteric fractures. Arch Orthop Trauma Surg 128:1443\u20131446","journal-title":"Arch Orthop Trauma Surg"},{"key":"2120_CR16","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.injury.2008.02.005","volume":"39","author":"RKJ Simmermacher","year":"2008","unstructured":"Simmermacher RKJ, Ljungqvist J, Bail H et al (2008) The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury 39:932\u2013939","journal-title":"Injury"},{"key":"2120_CR17","doi-asserted-by":"crossref","unstructured":"Pu JS, Liu L, Wang GL et al (2009) Results of the proximal femoral nail anti-rotation (PFNA) in elderly Chinese patients. Int Orthop 33:1441\u20131444","DOI":"10.1007\/s00264-009-0776-3"},{"key":"2120_CR18","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0020-1383(02)00171-7","volume":"34","author":"C Vicario","year":"2003","unstructured":"Vicario C, Marco F, Ortega L et al (2003) Necrosis of the femoral head after fixation of trochanteric fractures with gamma locking nail. A cause of late mechanical failure. Injury 34:129\u2013134","journal-title":"Injury"},{"key":"2120_CR19","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/S0020-1383(03)00076-7","volume":"35","author":"B Seral","year":"2004","unstructured":"Seral B, Garcia JM, Cegonino J et al (2004) Finite element study of intramedullary osteosynthesis in the treatment of trochanteric fractures of the hip: Gamma and PFN. Injury 35:130\u2013135","journal-title":"Injury"},{"key":"2120_CR20","doi-asserted-by":"crossref","first-page":"1250075","DOI":"10.1142\/S0219519412005125","volume":"12","author":"W Lizhen","year":"2012","unstructured":"Lizhen W, Feng Z, Jingyun H (2012) Biomechanical study on proximal femoral nail antirotation(PFNA) for intertrochanteric fracture. J Mech Med Biol 12:1250075","journal-title":"J Mech Med Biol"},{"key":"2120_CR21","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/S1350-4533(02)00185-6","volume":"25","author":"K Sitthiseripratip","year":"2003","unstructured":"Sitthiseripratip K, Van Oosterwyck H, Vander Sloten J et al (2003) Finite element study of trochanteric gamma nail for trochanteric fracture. Med Eng Phys 25:99\u2013106","journal-title":"Med Eng Phys"},{"key":"2120_CR22","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1749-799X-4-16","volume":"4","author":"GK Kouvidis","year":"2009","unstructured":"Kouvidis GK, Sommers MB, Giannoudis PV et al (2009) Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation. J Orthop Surg Res 4:16. doi: 10.1186\/1749-799X-4-16","journal-title":"J Orthop Surg Res"},{"key":"2120_CR23","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/01.bot.0000151819.95075.ad","volume":"19","author":"AL Utrilla","year":"2005","unstructured":"Utrilla AL, Reig JS, Mu\u00f1oz FM et al (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19:229\u2013233","journal-title":"J Orthop Trauma"},{"key":"2120_CR24","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1097\/TA.0b013e3181c995ec","volume":"68","author":"PC Lee","year":"2010","unstructured":"Lee PC, Hsieh PH, Chou YC et al (2010) Dynamic hip screws for unstable intertrochanteric fractures in elderly patients\u2014encouraging results with a cement augmentation technique. J Trauma 68:954\u2013964","journal-title":"J Trauma"},{"key":"2120_CR25","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/00003086-199611000-00010","volume":"332","author":"WJ Kraemer","year":"1996","unstructured":"Kraemer WJ, Hearn TC, Powell JN et al (1996) Fixation of segmental subtrochanteric fractures. A biomechanical study. Clin Orthop Relat Res 332:71\u201379","journal-title":"Clin Orthop Relat Res"},{"key":"2120_CR26","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.1007\/s00264-010-1199-x","volume":"35","author":"M Rupprecht","year":"2011","unstructured":"Rupprecht M, Grossterlinden L, Sellenschloh K et al (2011) Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS\u00ae and Intertan nail\u00ae. Int Orthop 35:1695\u20131701","journal-title":"Int Orthop"},{"key":"2120_CR27","first-page":"e288","volume":"36","author":"S Zhang","year":"2013","unstructured":"Zhang S, Zhang K, Jia Y et al (2013) InterTan nail versus Proximal Femoral Nail Antirotation-Asia in the treatment of unstable trochanteric fractures. Orthopedics 36:e288\u2013e294","journal-title":"Orthopedics"},{"key":"2120_CR28","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1007\/s00264-013-1888-3","volume":"37","author":"SM Zielinski","year":"2013","unstructured":"Zielinski SM, Meeuwis MA, Heetveld MJ et al (2013) Adherence to a femoral neck fracture treatment guideline. Int Orthop 37:1327\u20131334","journal-title":"Int Orthop"},{"key":"2120_CR29","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1007\/s00264-012-1600-z","volume":"36","author":"J Schneppendahl","year":"2012","unstructured":"Schneppendahl J, Grassmann JP, Petrov V et al (2012) Decreasing mortality after femoral neck fracture treated with bipolar hemiarthroplasty during the last twenty years. Int Orthop 36:2021\u20132026","journal-title":"Int Orthop"},{"key":"2120_CR30","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00264-011-1354-z","volume":"36","author":"A Kannan","year":"2012","unstructured":"Kannan A, Kancherla R, McMahon S et al (2012) Arthroplasty options in femoral-neck fracture: answers from the national registries. Int Orthop 36:1\u20138","journal-title":"Int Orthop"},{"key":"2120_CR31","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1016\/j.injury.2012.03.032","volume":"43","author":"T Basso","year":"2012","unstructured":"Basso T, Klaksvik J, Syversen U et al (2012) Biomechanical femoral neck fracture experiments\u2014a narrative review. Injury 43:1633\u20131639","journal-title":"Injury"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-013-2120-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-013-2120-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-013-2120-1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T12:44:45Z","timestamp":1558701885000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-013-2120-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,10,5]]},"references-count":31,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["2120"],"URL":"https:\/\/doi.org\/10.1007\/s00264-013-2120-1","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,10,5]]}}}