{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T12:14:58Z","timestamp":1788351298071,"version":"build-2803163510"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2014,12,20]],"date-time":"2014-12-20T00:00:00Z","timestamp":1419033600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2015,7]]},"DOI":"10.1007\/s00264-014-2616-3","type":"journal-article","created":{"date-parts":[[2014,12,19]],"date-time":"2014-12-19T10:18:41Z","timestamp":1418984321000},"page":"1259-1267","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging"],"prefix":"10.1007","volume":"39","author":[{"given":"Jean Yves","family":"Lazennec","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrien","family":"Brusson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Folinais","family":"Dominique","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc-Antoine","family":"Rousseau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aidin Eslam","family":"Pour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2014,12,20]]},"reference":[{"key":"2616_CR1","first-page":"131","volume":"54","author":"MN Charles","year":"2005","unstructured":"Charles MN, Bourne RB, Davey JR et al (2005) Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect 54:131\u2013141","journal-title":"Instr Course Lect"},{"key":"2616_CR2","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.arth.2004.01.016","volume":"20","author":"I Asayama","year":"2005","unstructured":"Asayama I, Chamnongkich S, Simpson KJ et al (2005) Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty. J Arthroplasty 20:414\u2013420. doi: 10.1016\/j.arth.2004.01.016","journal-title":"J Arthroplasty"},{"key":"2616_CR3","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1302\/0301-620X.77B6.7593096","volume":"77","author":"BJ McGrory","year":"1995","unstructured":"McGrory BJ, Morrey BF, Cahalan TD et al (1995) Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg (Br) 77:865\u2013869","journal-title":"J Bone Joint Surg (Br)"},{"key":"2616_CR4","doi-asserted-by":"crossref","unstructured":"Sakalkale DP, Sharkey PF, Eng K, et al. (2001) Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res 125\u2013134","DOI":"10.1097\/00003086-200107000-00019"},{"key":"2616_CR5","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1007\/s00264-011-1477-2","volume":"36","author":"F Schmidutz","year":"2012","unstructured":"Schmidutz F, Beirer M, Weber P et al (2012) Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36:1341\u20131347. doi: 10.1007\/s00264-011-1477-2","journal-title":"Int Orthop"},{"issue":"7","key":"2616_CR6","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1007\/s00264-012-1512-y","volume":"36","author":"T Ill\u00e9s","year":"2012","unstructured":"Ill\u00e9s T, Somoske\u00f6y S (2012) The EOS\u2122 imaging system and its uses in daily orthopaedic practice. Int Orthop 36(7):1325\u20131331. doi: 10.1007\/s00264-012-1512-y","journal-title":"Int Orthop"},{"issue":"6","key":"2616_CR7","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1007\/s00264-011-1403-7","volume":"36","author":"P Than","year":"2012","unstructured":"Than P, Szuper K, Somoske\u00f6y S, Warta V, Ill\u00e9s T (2012) Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int Orthop 36(6):1291\u20131297. doi: 10.1007\/s00264-011-1403-7","journal-title":"Int Orthop"},{"key":"2616_CR8","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1080\/10255842.2010.540758","volume":"15","author":"Y Chaibi","year":"2012","unstructured":"Chaibi Y, Cresson T, Aubert B et al (2012) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 15:457\u2013466. doi: 10.1080\/10255842.2010.540758","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"2616_CR9","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/BF02344767","volume":"38","author":"D Mitton","year":"2000","unstructured":"Mitton D, Landry C, V\u00e9ron S et al (2000) 3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes. Med Biol Eng Comput 38:133\u2013139","journal-title":"Med Biol Eng Comput"},{"key":"2616_CR10","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1007\/BF02344797","volume":"39","author":"A Mitulescu","year":"2001","unstructured":"Mitulescu A, Semaan I, de Guise JA et al (2001) Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique. Med Biol Eng Comput 39:152\u2013158","journal-title":"Med Biol Eng Comput"},{"key":"2616_CR11","doi-asserted-by":"crossref","first-page":"51","DOI":"10.3109\/10929080400018122","volume":"9","author":"A Bras Le","year":"2004","unstructured":"Le Bras A, Laporte S, Bousson V et al (2004) 3D reconstruction of the proximal femur with low-dose digital stereoradiography. Comput Aided Surg 9:51\u201357. doi: 10.3109\/10929080400018122","journal-title":"Comput Aided Surg"},{"key":"2616_CR12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/10255840500521786","volume":"9","author":"D Mitton","year":"2006","unstructured":"Mitton D, Desch\u00eanes S, Laporte S et al (2006) 3D reconstruction of the pelvis from bi-planar radiography. Comput Methods Biomech Biomed Eng 9:1\u20135. doi: 10.1080\/10255840500521786","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"2616_CR13","doi-asserted-by":"crossref","first-page":"W607","DOI":"10.2214\/AJR.11.8295","volume":"199","author":"FM Buck","year":"2012","unstructured":"Buck FM, Guggenberger R, Koch PP, Pfirrmann CWA (2012) Femoral and tibial torsion measurements with 3D models based on low-dose biplanar radiographs in comparison with standard CT measurements. AJR Am J Roentgenol 199:W607\u2013W612. doi: 10.2214\/AJR.11.8295","journal-title":"AJR Am J Roentgenol"},{"key":"2616_CR14","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.otsr.2012.03.014","volume":"98","author":"B Guenoun","year":"2012","unstructured":"Guenoun B, Zadegan F, Aim F et al (2012) Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction. Orthop Traumatol Surg Res 98:506\u2013513. doi: 10.1016\/j.otsr.2012.03.014","journal-title":"Orthop Traumatol Surg Res"},{"key":"2616_CR15","doi-asserted-by":"crossref","unstructured":"Lazennec J-Y, Rousseau MA, Rangel A et al (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97(4):3. doi: 10.1016\/j.otsr.2011.02.006","DOI":"10.1016\/j.otsr.2011.02.006"},{"key":"2616_CR16","doi-asserted-by":"crossref","unstructured":"Folinais D, Thelen P, Delin C et al (2013) Measuring femoral and rotational alignment: EOS system versus computed tomography. Orthop Traumatol Surg Res 99(5):509-516. doi: 10.1016\/j.otsr.2012.12.023","DOI":"10.1016\/j.otsr.2012.12.023"},{"key":"2616_CR17","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1302\/0301-620X.94B4.28067","volume":"94-B","author":"C Merle","year":"2012","unstructured":"Merle C, Waldstein W, Pegg E et al (2012) Femoral offset is underestimated on anteroposterior radiographs of the pelvis but accurately assessed on anteroposterior radiographs of the hip. J Bone Joint Surg (Br) 94-B:477\u2013482. doi: 10.1302\/0301-620X.94B4.28067","journal-title":"J Bone Joint Surg (Br)"},{"key":"2616_CR18","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1007\/s11999-009-1086-1","volume":"468","author":"T Renkawitz","year":"2010","unstructured":"Renkawitz T, Schuster T, Grifka J et al (2010) Leg length and offset measures with a pinless femoral reference array during THA. Clin Orthop Relat Res 468:1862\u20131868. doi: 10.1007\/s11999-009-1086-1","journal-title":"Clin Orthop Relat Res"},{"key":"2616_CR19","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1302\/0301-620X.91B3.21390","volume":"91","author":"E Sariali","year":"2009","unstructured":"Sariali E, Mouttet A, Pasquier G et al (2009) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg (Br) 91:333\u2013340. doi: 10.1302\/0301-620X.91B3.21390","journal-title":"J Bone Joint Surg (Br)"},{"key":"2616_CR20","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1016\/j.arth.2008.04.031","volume":"24","author":"E Sariali","year":"2009","unstructured":"Sariali E, Mouttet A, Pasquier G, Durante E (2009) Three-dimensional hip anatomy in osteoarthritis. Analysis of the femoral offset. J Arthroplasty 24:990\u2013997. doi: 10.1016\/j.arth.2008.04.031","journal-title":"J Arthroplasty"},{"key":"2616_CR21","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/S0761-8425(04)71243-7","volume":"21","author":"D Journois","year":"2004","unstructured":"Journois D (2004) Concordance between two variables: graphical approach (Bland and Altman\u2019s method). Rev Mal Respir 21:127\u2013130","journal-title":"Rev Mal Respir"},{"key":"2616_CR22","first-page":"218","volume":"89","author":"L Rillardon","year":"2003","unstructured":"Rillardon L, Levassor N, Guigui P et al (2003) Validation of a tool to measure pelvic and spinal parameters of sagittal balance. Rev Chir Orthop Reparatrice Appar Mot 89:218\u2013227","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"2616_CR23","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.annrmp.2005.04.004","volume":"48","author":"J Fermanian","year":"2005","unstructured":"Fermanian J (2005) Validation of assessment scales in physical medicine and rehabilitation: how are psychometric properties determined? Ann Readapt Med Phys 48:281\u2013287. doi: 10.1016\/j.annrmp.2005.04.004","journal-title":"Ann Readapt Med Phys"},{"key":"2616_CR24","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/S0761-8425(04)71242-5","volume":"21","author":"C Fuhrman","year":"2004","unstructured":"Fuhrman C, Choua\u00efd C (2004) Concordance between two variables: numerical approaches (qualitative observations\u2014the kappa coefficient-; quantitative measures. Rev Mal Respir 21:123\u2013125","journal-title":"Rev Mal Respir"},{"key":"2616_CR25","unstructured":"International Organization for Standardization (1994) Application of statistics\u2014accuracy (trueness and precision) of measurement methods and results\u2014Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method. ISO 5725\u20132:1994"},{"key":"2616_CR26","doi-asserted-by":"crossref","first-page":"28","DOI":"10.2106\/00004623-199274010-00005","volume":"74","author":"PJ Rubin","year":"1992","unstructured":"Rubin PJ, Leyvraz PF, Aubaniac JM et al (1992) The morphology of the proximal femur. A three-dimensional radiographic analysis. J Bone Joint Surg (Br) 74:28\u201332","journal-title":"J Bone Joint Surg (Br)"},{"key":"2616_CR27","first-page":"229","volume":"88","author":"E Thomasson De","year":"2002","unstructured":"De Thomasson E, Mazel C, Guingand O, Terracher R (2002) Value of preoperative planning in total hip arthroplasty. Rev Chir Orthop Reparatrice Appar Mot 88:229\u2013235","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"2616_CR28","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.otsr.2010.02.006","volume":"96","author":"G Pasquier","year":"2010","unstructured":"Pasquier G, Ducharne G, Ali ES et al (2010) Total hip arthroplasty offset measurement: is CT scan the most accurate option? Orthop Traumatol Surg Res 96:367\u2013375. doi: 10.1016\/j.otsr.2010.02.006","journal-title":"Orthop Traumatol Surg Res"},{"key":"2616_CR29","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/BF00360817","volume":"12","author":"B Guyer","year":"1984","unstructured":"Guyer B, Smith DS, Cady RB et al (1984) Dosimetry of computerized tomography in the evaluation of hip dysplasia. Skeletal Radiol 12:123\u2013127","journal-title":"Skeletal Radiol"},{"key":"2616_CR30","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1177\/02841851960371P127","volume":"37","author":"A Jonsson","year":"1996","unstructured":"Jonsson A, Herrlin K, Jonsson K et al (1996) Radiation dose reduction in computed skeletal radiography. Effect on image quality. Acta Radiol 37:128\u2013133","journal-title":"Acta Radiol"},{"key":"2616_CR31","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.medengphy.2003.11.008","volume":"26","author":"R Lattanzi","year":"2004","unstructured":"Lattanzi R, Baruffaldi F, Zannoni C, Viceconti M (2004) Specialised CT scan protocols for 3-D pre-operative planning of total hip replacement. Med Eng Phys 26:237\u2013245. doi: 10.1016\/j.medengphy.2003.11.008","journal-title":"Med Eng Phys"},{"key":"2616_CR32","doi-asserted-by":"crossref","first-page":"578","DOI":"10.2174\/1874325001206010578","volume":"6","author":"B Preininger","year":"2012","unstructured":"Preininger B, Schmorl K, von Roth P et al (2012) Femoral offset (3D) in patients without osteoarthritis\u2014index values from 200 hip joints. Open Orthop J 6:578\u2013581. doi: 10.2174\/1874325001206010578","journal-title":"Open Orthop J"},{"key":"2616_CR33","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1097\/BRS.0b013e3181bdcaa4","volume":"35","author":"S Desch\u00eanes","year":"2010","unstructured":"Desch\u00eanes S, Charron G, Beaudoin G et al (2010) Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager. Spine 35:989\u2013994. doi: 10.1097\/BRS.0b013e3181bdcaa4","journal-title":"Spine"},{"key":"2616_CR34","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3310\/hta16140","volume":"16","author":"C McKenna","year":"2012","unstructured":"McKenna C, Wade R, Faria R et al (2012) EOS 2D\/3D X-ray imaging system: a systematic review and economic evaluation. Health Technol Assess 16:1\u2013188. doi: 10.3310\/hta16140","journal-title":"Health Technol Assess"},{"key":"2616_CR35","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1007\/s00586-012-2469-7","volume":"22","author":"R Wade","year":"2013","unstructured":"Wade R, Yang H, McKenna C et al (2013) A systematic review of the clinical effectiveness of EOS 2D\/3D X-ray imaging system. Eur Spine J 22:296\u2013304. doi: 10.1007\/s00586-012-2469-7","journal-title":"Eur Spine J"},{"key":"2616_CR36","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1053\/j.sart.2013.01.005","volume":"23","author":"J-Y Lazennec","year":"2012","unstructured":"Lazennec J-Y, Brusson A, Rousseau M-A (2012) THA patients in standing and sitting positions: a prospective evaluation using the low-dose \u201cfull-body\u201d EOS. Semin Arthroplast 23:220\u2013225. doi: 10.1053\/j.sart.2013.01.005","journal-title":"Semin Arthroplast"},{"key":"2616_CR37","author":"M Wybier","year":"2012","unstructured":"Wybier M, Bossard P (2012) Musculoskeletal imaging in progress: the EOS imaging system. Joint Bone Spine. doi: 10.1016\/j.jbspin.2012.09.018","journal-title":"Joint Bone Spine"},{"key":"2616_CR38","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1054\/arth.2002.33263","volume":"17","author":"RB Bourne","year":"2002","unstructured":"Bourne RB, Rorabeck CH (2002) Soft tissue balancing: the hip. J Arthroplasty 17:17\u201322. doi: 10.1054\/arth.2002.33263","journal-title":"J Arthroplasty"},{"key":"2616_CR39","doi-asserted-by":"crossref","first-page":"791","DOI":"10.2214\/ajr.168.3.9057536","volume":"168","author":"RJ Tomczak","year":"1997","unstructured":"Tomczak RJ, Guenther KP, Rieber A et al (1997) MR imaging measurement of the femoral antetorsional angle as a new technique: comparison with CT in children and adults. AJR Am J Roentgenol 168:791\u2013794. doi: 10.2214\/ajr.168.3.9057536","journal-title":"AJR Am J Roentgenol"},{"key":"2616_CR40","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1097\/00004728-199807000-00019","volume":"22","author":"N Sugano","year":"1998","unstructured":"Sugano N, Noble PC, Kamaric E (1998) A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 22:610\u2013614","journal-title":"J Comput Assist Tomogr"},{"key":"2616_CR41","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1007\/BF00572255","volume":"1","author":"DS Weiner","year":"1978","unstructured":"Weiner DS, Cook AJ, Hoyt WA, Oravec CE (1978) Computed tomography in the measurement of femoral anteversion. Orthopedics 1:299\u2013306","journal-title":"Orthopedics"},{"key":"2616_CR42","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3109\/17453678308992864","volume":"54","author":"O Reiker\u00e5s","year":"1983","unstructured":"Reiker\u00e5s O, Bjerkreim I, Kolbenstvedt A (1983) Anteversion of the acetabulum and femoral neck in normals and in patients with osteoarthritis of the hip. Acta Orthop Scand 54:18\u201323","journal-title":"Acta Orthop Scand"},{"key":"2616_CR43","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.2106\/00004623-198769080-00010","volume":"69","author":"SB Murphy","year":"1987","unstructured":"Murphy SB, Simon SR, Kijewski PK et al (1987) Femoral anteversion. J Bone Joint Surg Am 69:1169\u20131176","journal-title":"J Bone Joint Surg Am"},{"key":"2616_CR44","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1007\/s776-002-8418-7","volume":"7","author":"T Sakai","year":"2002","unstructured":"Sakai T, Sugano N, Ohzono K et al (2002) Femoral anteversion, femoral offset, and abductor lever arm after total hip arthroplasty using a modular femoral neck system. J Orthop Sci 7:62\u201367. doi: 10.1007\/s007760200010","journal-title":"J Orthop Sci"},{"key":"2616_CR45","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.otsr.2009.03.010","volume":"95","author":"G Lecerf","year":"2009","unstructured":"Lecerf G, Fessy MH, Philippot R et al (2009) Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty. Orthop Traumatol Surg Res 95:210\u2013219. doi: 10.1016\/j.otsr.2009.03.010","journal-title":"Orthop Traumatol Surg Res"},{"key":"2616_CR46","doi-asserted-by":"crossref","unstructured":"Delp SL, Wixson RL, Komattu AV, Kocmond JH (1996) How superior placement of the joint center in hip arthroplasty affects the abductor muscles. Clin Orthop Relat Res 137\u2013146","DOI":"10.1097\/00003086-199607000-00022"},{"key":"2616_CR47","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.arth.2004.04.016","volume":"20","author":"A Gonzalez Della Valle","year":"2005","unstructured":"Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51\u201358. doi: 10.1016\/j.arth.2004.04.016","journal-title":"J Arthroplasty"},{"key":"2616_CR48","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/S0883-5403(05)80153-6","volume":"10","author":"LW Carter","year":"1995","unstructured":"Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10:507\u2013513","journal-title":"J Arthroplasty"},{"issue":"Suppl","key":"2616_CR49","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/S0883-5403(07)80031-3","volume":"7","author":"JL Knight","year":"1992","unstructured":"Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7(Suppl):403\u2013409","journal-title":"J Arthroplasty"},{"key":"2616_CR50","doi-asserted-by":"crossref","first-page":"196.e7","DOI":"10.1016\/j.arth.2012.03.050","volume":"28","author":"NG Sotereanos","year":"2013","unstructured":"Sotereanos NG, Sauber TJ, Tupis TT (2013) Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty 28:196.e7\u2013196.e9. doi: 10.1016\/j.arth.2012.03.050","journal-title":"J Arthroplasty"},{"key":"2616_CR51","doi-asserted-by":"crossref","first-page":"543.e13","DOI":"10.1016\/j.arth.2012.07.026","volume":"28","author":"SD Werner","year":"2013","unstructured":"Werner SD, Bono JV, Nandi S et al (2013) Adverse tissue reactions in modular exchangeable neck implants: a report of two cases. J Arthroplasty 28:543.e13\u2013543.e15. doi: 10.1016\/j.arth.2012.07.026","journal-title":"J Arthroplasty"},{"key":"2616_CR52","doi-asserted-by":"crossref","first-page":"865","DOI":"10.2106\/JBJS.L.01042","volume":"95","author":"HJ Cooper","year":"2013","unstructured":"Cooper HJ, Urban RM, Wixson RL et al (2013) Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg 95:865\u2013872. doi: 10.2106\/JBJS.L.01042","journal-title":"J Bone Joint Surg"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-014-2616-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-014-2616-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-014-2616-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,18]],"date-time":"2019-08-18T16:04:47Z","timestamp":1566144287000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-014-2616-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,20]]},"references-count":52,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2015,7]]}},"alternative-id":["2616"],"URL":"https:\/\/doi.org\/10.1007\/s00264-014-2616-3","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,20]]}}}