{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T22:54:46Z","timestamp":1754261686341},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2015,2,6]],"date-time":"2015-02-06T00:00:00Z","timestamp":1423180800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2015,9]]},"DOI":"10.1007\/s00264-014-2644-z","type":"journal-article","created":{"date-parts":[[2015,2,4]],"date-time":"2015-02-04T23:15:13Z","timestamp":1423091713000},"page":"1803-1811","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Influence of implant design on blood metal ion concentrations in metal-on-metal total hip replacement patients"],"prefix":"10.1007","volume":"39","author":[{"given":"Gulraj S.","family":"Matharu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fiona","family":"Berryman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lesley","family":"Brash","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul B.","family":"Pynsent","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronan B.","family":"Treacy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David J.","family":"Dunlop","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,2,6]]},"reference":[{"key":"2644_CR1","doi-asserted-by":"crossref","first-page":"1614","DOI":"10.2106\/JBJS.H.01220","volume":"91-A","author":"KJ Bozic","year":"2009","unstructured":"Bozic KJ, Kurtz S, Lau E, Ong K, Chiu V, Vail TP et al (2009) The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg (Am) 91-A:1614\u20131620","journal-title":"J Bone Joint Surg (Am)"},{"key":"2644_CR2","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1016\/S0140-6736(12)60353-5","volume":"379","author":"AJ Smith","year":"2012","unstructured":"Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW (2012) Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet 379:1199\u20131204","journal-title":"Lancet"},{"key":"2644_CR3","doi-asserted-by":"crossref","first-page":"1771","DOI":"10.1007\/s00264-011-1233-7","volume":"35","author":"WP Zijlstra","year":"2011","unstructured":"Zijlstra WP, van den Akker-Scheek I, Zee MJ, van Raay JJ (2011) No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty? Int Orthop 35:1771\u20131776","journal-title":"Int Orthop"},{"key":"2644_CR4","doi-asserted-by":"crossref","unstructured":"Fink Barnes LA, Johnson SH, Patrick DA Jr, Macaulay W (2014) Metal-on-metal hip resurfacing compared with total hip arthroplasty: two to five year outcomes in men younger than sixty five years. Int Orthop 38:2435\u20132440","DOI":"10.1007\/s00264-014-2506-8"},{"key":"2644_CR5","doi-asserted-by":"crossref","first-page":"e1410","DOI":"10.1136\/bmj.e1410","volume":"344","author":"D Cohen","year":"2012","unstructured":"Cohen D (2012) How safe are metal-on-metal hip implants? BMJ 344:e1410","journal-title":"BMJ"},{"key":"2644_CR6","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1302\/0301-620X.93B5.26309","volume":"93-B","author":"BJ Bolland","year":"2011","unstructured":"Bolland BJ, Culliford DJ, Langton DJ, Millington JP, Arden NK, Latham JM (2011) High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. J Bone Joint Surg (Br) 93-B:608\u2013615","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR7","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1302\/0301-620X.93B8.26040","volume":"93-B","author":"DJ Langton","year":"2011","unstructured":"Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Mereddy P et al (2011) Accelerating failure rate of the ASR total hip replacement. J Bone Joint Surg (Br) 93-B:1011\u20131016","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR8","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1302\/0301-620X.92B1.22770","volume":"92-B","author":"DJ Langton","year":"2010","unstructured":"Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and larger-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg (Br) 92-B:38\u201346","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR9","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1016\/S0140-6736(12)60989-1","volume":"380","author":"AJ Smith","year":"2012","unstructured":"Smith AJ, Dieppe P, Howard PW, Blom AW, National Joint Registry for England and Wales (2012) Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales. Lancet 380:1759\u20131766","journal-title":"Lancet"},{"key":"2644_CR10","unstructured":"Medical and Healthcare Products Regulatory Agency (MHRA) (2010) Medical device alert: ASR\u2122 hip replacement implant manufactured by DePuy International Ltd. MDA\/2010\/069. http:\/\/www.mhra.gov.uk\/ . Accessed 19 Nov 2014"},{"key":"2644_CR11","unstructured":"Medical and Healthcare products Regulatory Agency (MHRA) (2012) Medical device alert: all metal-on-metal (MoM) hip replacements. MDA\/2012\/036. http:\/\/www.mhra.gov.uk\/ . Accessed 19 Nov 2014"},{"key":"2644_CR12","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1302\/2046-3758.25.2000148","volume":"2","author":"RP Sidaginamale","year":"2013","unstructured":"Sidaginamale RP, Joyce TJ, Lord JK, Jefferson R, Blain PG, Nargol AV et al (2013) Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces. Bone Joint Res 2:84\u201395","journal-title":"Bone Joint Res"},{"key":"2644_CR13","doi-asserted-by":"crossref","first-page":"3814","DOI":"10.1007\/s11999-013-2944-4","volume":"471","author":"SA Almousa","year":"2013","unstructured":"Almousa SA, Greidanus NV, Masri BA, Duncan CP, Garbuz DS (2013) The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty. Clin Orthop Relat Res 471:3814\u20133821","journal-title":"Clin Orthop Relat Res"},{"key":"2644_CR14","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1302\/0301-620X.95B8.31377","volume":"95","author":"D Ebreo","year":"2013","unstructured":"Ebreo D, Bell PJ, Arshad H, Donell ST, Toms A, Nolan JF (2013) Serial magnetic resonance imaging of metal-on-metal total hip replacements. Follow-up of a cohort of 28\u00a0mm Ultima TPS THRs. Bone Joint J 95:1035\u20131039","journal-title":"Bone Joint J"},{"key":"2644_CR15","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1007\/s00264-012-1570-1","volume":"36","author":"M Bernstein","year":"2012","unstructured":"Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J (2012) Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty. Int Orthop 36:1807\u20131812","journal-title":"Int Orthop"},{"key":"2644_CR16","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1302\/0301-620X.90B10.20533","volume":"90-B","author":"R Haan De","year":"2008","unstructured":"De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg (Br) 90-B:1291\u20131297","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR17","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1302\/0301-620X.91B12.22287","volume":"91-B","author":"S Glyn-Jones","year":"2009","unstructured":"Glyn-Jones S, Pandit H, Kwon YM, Doll H, Gill HS, Murray DW (2009) Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg (Br) 91-B:1566\u20131574","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR18","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1302\/0301-620X.92B8.24194","volume":"92-B","author":"G Grammatopoulos","year":"2010","unstructured":"Grammatopoulos G, Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D et al (2010) Optimal acetabular orientation for hip resurfacing. J Bone Joint Surg (Br) 92-B:1072\u20131078","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR19","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1302\/0301-620X.93B2.25099","volume":"93-B","author":"DJ Langton","year":"2011","unstructured":"Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP et al (2011) Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg (Br) 93-B:164\u2013171","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR20","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/978-1-4614-8999-3_5","volume-title":"Metal-on-metal bearings. A clinical practicum","author":"D Langton","year":"2014","unstructured":"Langton D (2014) Are metal ion levels a trigger for surgical intervention? In: Jones LC, Greenwald AS, Haggard WO (eds) Metal-on-metal bearings. A clinical practicum. Springer, New York, pp 63\u201382, Chapter 5"},{"key":"2644_CR21","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1007\/s00264-014-2300-7","volume":"38","author":"A Reito","year":"2014","unstructured":"Reito A, Moilanen T, Puolakka T, Pajam\u00e4ki J, Eskelinen A (2014) Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement. Int Orthop 38:1353\u20131361","journal-title":"Int Orthop"},{"key":"2644_CR22","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1007\/s11999-010-1630-z","volume":"469","author":"M Bernstein","year":"2011","unstructured":"Bernstein M, Walsh A, Petit A, Zukor DJ, Huk OL, Antoniou J (2011) Femoral head size does not affect ion values in metal-on-metal total hips. Clin Orthop Relat Res 469:1642\u20131650","journal-title":"Clin Orthop Relat Res"},{"issue":"Supp 2","key":"2644_CR23","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.J.01885","volume":"93-A","author":"M Lavigne","year":"2011","unstructured":"Lavigne M, Belzile EL, Roy A, Morin F, Amzica T, Vendittoli PA (2011) Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve. J Bone Joint Surg (Am) 93-A(Supp 2):128\u2013136","journal-title":"J Bone Joint Surg (Am)"},{"key":"2644_CR24","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.2106\/JBJS.L.01481","volume":"95-A","author":"EY Chang","year":"2013","unstructured":"Chang EY, McAnally JL, Van Horne JR, Van Horne JG, Wolfson T, Gamst A et al (2013) Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal total hip replacements. J Bone Joint Surg (Am) 95-A:2015\u20132020","journal-title":"J Bone Joint Surg (Am)"},{"key":"2644_CR25","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.arth.2013.04.022","volume":"29","author":"AR Emmanuel","year":"2014","unstructured":"Emmanuel AR, Bergin KM, Kelly GE, McCoy GF, Wozniak AP, Quinlan JF (2014) The effect of acetabular inclination on metal ion levels following metal-on-metal hip arthroplasty. J Arthroplasty 29:186\u2013191","journal-title":"J Arthroplasty"},{"key":"2644_CR26","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/s11999-012-2526-x","volume":"471","author":"C Straeten Van Der","year":"2013","unstructured":"Van Der Straeten C, Grammatopoulos G, Gill HS, Calistri A, Campbell P, De Smet KA (2013) The 2012 Otto Aufranc Award: the interpretation of metal ion levels in unilateral and bilateral hip resurfacing. Clin Orthop Relat Res 471:377\u2013385","journal-title":"Clin Orthop Relat Res"},{"key":"2644_CR27","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1302\/0301-620X.78B2.0780185","volume":"78-B","author":"J Dawson","year":"1996","unstructured":"Dawson J, Fitzpatrick R, Carr A, Murray D (1996) Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg (Br) 78-B:185\u2013190","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR28","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1302\/0301-620X.90B7.20213","volume":"90-B","author":"H Pandit","year":"2008","unstructured":"Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL et al (2008) Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg (Br) 90-B:847\u2013851","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR29","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","volume":"86","author":"PE Shrout","year":"1979","unstructured":"Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420\u2013428","journal-title":"Psychol Bull"},{"key":"2644_CR30","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1191\/096228099673819272","volume":"8","author":"JM Bland","year":"1999","unstructured":"Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135\u2013160","journal-title":"Stat Methods Med Res"},{"key":"2644_CR31","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1302\/0301-620X.87B2.15095","volume":"87-B","author":"PB Pynsent","year":"2005","unstructured":"Pynsent PB, Adams DJ, Disney SP (2005) The Oxford hip and knee outcome questionnaires for arthroplasty. J Bone Joint Surg (Br) 87-B:241\u2013248","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR32","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1302\/0301-620X.89B8.19424","volume":"89-B","author":"DW Murray","year":"2007","unstructured":"Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ et al (2007) The use of the Oxford hip and knee scores. J Bone Joint Surg (Br) 89-B:1010\u20131014","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR33","volume-title":"R: a language and environment for statistical computing","author":"R Core Team","year":"2013","unstructured":"R Core Team (2013) R: a language and environment for statistical computing. R Foundation for Statistical Computing, Vienna"},{"key":"2644_CR34","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1302\/0301-620X.93B6.25804","volume":"93-B","author":"K Davda","year":"2011","unstructured":"Davda K, Lali FV, Sampson B, Skinner JA, Hart AJ (2011) An analysis of metal ion levels in the joint fluid of symptomatic patients with metal-on-metal hip replacements. J Bone Joint Surg (Br) 93-B:738\u2013745","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR35","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1002\/jor.22459","volume":"32","author":"AK Matthies","year":"2014","unstructured":"Matthies AK, Henckel J, Cro S, Suarez A, Noble PC, Skinner J et al (2014) Predicting wear and blood metal ion levels in metal-on-metal hip resurfacing. J Orthop Res 32:167\u2013174","journal-title":"J Orthop Res"},{"key":"2644_CR36","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","volume":"60-A","author":"GE Lewinnek","year":"1978","unstructured":"Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg (Am) 60-A:217\u2013220","journal-title":"J Bone Joint Surg (Am)"},{"key":"2644_CR37","unstructured":"National Joint Registry for England and Wales. 10th Annual Report 2013. http:\/\/njrcentre.org.uk . Accessed 19 Nov 2014"},{"key":"2644_CR38","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.2106\/JBJS.K.01352","volume":"94-A","author":"HJ Cooper","year":"2012","unstructured":"Cooper HJ, Della Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM et al (2012) Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg (Am) 94-A:1655\u20131661","journal-title":"J Bone Joint Surg (Am)"},{"key":"2644_CR39","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1302\/2046-3758.14.2000047","volume":"1","author":"DJ Langton","year":"2012","unstructured":"Langton DJ, Sidaginamale R, Lord JK, Nargol AV, Joyce TJ (2012) Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res 1:56\u201363","journal-title":"Bone Joint Res"},{"key":"2644_CR40","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1007\/s11999-009-1029-x","volume":"468","author":"DS Garbuz","year":"2010","unstructured":"Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP (2010) The John Charnley Award: metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 468:318\u2013325","journal-title":"Clin Orthop Relat Res"},{"key":"2644_CR41","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.ocl.2011.01.005","volume":"42","author":"PE Beaul\u00e9","year":"2011","unstructured":"Beaul\u00e9 PE, Kim PR, Hamdi A, Fazekas A (2011) A prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement. Orthop Clin N Am 42:251\u2013257","journal-title":"Orthop Clin N Am"},{"key":"2644_CR42","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.arth.2004.09.003","volume":"19","author":"W Brodner","year":"2004","unstructured":"Brodner W, Gr\u00fcbl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F (2004) Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 19:66\u201370","journal-title":"J Arthroplasty"},{"key":"2644_CR43","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s11999-013-3222-1","volume":"472","author":"TK Fehring","year":"2014","unstructured":"Fehring TK, Odum S, Sproul R, Weathersbee J (2014) High frequency of adverse local tissue reactions in asymptomatic patients with metal-on-metal THA. Clin Orthop Relat Res 472:517\u2013522","journal-title":"Clin Orthop Relat Res"},{"key":"2644_CR44","doi-asserted-by":"crossref","first-page":"317","DOI":"10.2106\/JBJS.J.01508","volume":"94-A","author":"AJ Hart","year":"2012","unstructured":"Hart AJ, Satchithananda K, Liddle AD, Sabah SA, McRobbie D, Henckel J et al (2012) Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case\u2013control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg (Am) 94-A:317\u2013325","journal-title":"J Bone Joint Surg (Am)"},{"key":"2644_CR45","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1302\/0301-620X.94B8.27626","volume":"94-B","author":"IA Malek","year":"2012","unstructured":"Malek IA, King A, Sharma H, Malek S, Lyons K, Jones S et al (2012) The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip. J Bone Joint Surg (Br) 94-B:1045\u20131050","journal-title":"J Bone Joint Surg (Br)"},{"key":"2644_CR46","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1007\/s11999-011-2201-7","volume":"470","author":"AK Matthies","year":"2012","unstructured":"Matthies AK, Skinner JA, Osmani H, Henckel J, Hart AJ (2012) Pseudotumors are common in well-positioned low-wearing metal-on-metal hips. Clin Orthop Relat Res 470:1895\u20131906","journal-title":"Clin Orthop Relat Res"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-014-2644-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-014-2644-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-014-2644-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,20]],"date-time":"2019-08-20T12:57:54Z","timestamp":1566305874000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-014-2644-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,6]]},"references-count":46,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["2644"],"URL":"https:\/\/doi.org\/10.1007\/s00264-014-2644-z","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,6]]}}}