{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T20:17:13Z","timestamp":1782332233947,"version":"3.54.5"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2016,5,13]],"date-time":"2016-05-13T00:00:00Z","timestamp":1463097600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Nature Science Foundation of China","doi-asserted-by":"crossref","award":["81071473"],"award-info":[{"award-number":["81071473"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2017,4]]},"DOI":"10.1007\/s00264-016-3217-0","type":"journal-article","created":{"date-parts":[[2016,5,13]],"date-time":"2016-05-13T10:44:49Z","timestamp":1463136289000},"page":"723-730","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles"],"prefix":"10.1007","volume":"41","author":[{"given":"Yufei","family":"Yan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianmin","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaizhe","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaidi","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weixiang","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingming","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuan","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,5,13]]},"reference":[{"key":"3217_CR1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-015-3064-4","author":"JL Prudhon","year":"2015","unstructured":"Prudhon JL, Desmarchelier R, Hamadouche M, Delaunay C, Verdier R, SoFcot (2015) Causes for revision of dual-mobility and standard primary total hip arthroplasty : matched case-control study based on a prospective multicenter study of two thousand and forty four implants. Int Orthop. doi: 10.1007\/s00264-015-3064-4","journal-title":"Int Orthop"},{"issue":"11","key":"3217_CR2","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.2106\/00004623-199711000-00001","volume":"79","author":"DH Sochart","year":"1997","unstructured":"Sochart DH, Porter ML (1997) The long-term results of Charnley low-friction arthroplasty in young patients who have congenital dislocation, degenerative osteoarthrosis, or rheumatoid arthritis. J Bone Joint Surg Am 79(11):1599\u20131617","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"3217_CR3","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1243\/0954411011535939","volume":"215","author":"D Dowson","year":"2001","unstructured":"Dowson D (2001) New joints for the Millennium: wear control in total replacement hip joints. Proc Inst Mech Eng H J Eng Med 215(4):335\u2013358","journal-title":"Proc Inst Mech Eng H J Eng Med"},{"issue":"2","key":"3217_CR4","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1302\/0301-620X.96B2.31920","volume":"96-B","author":"A Rajpura","year":"2014","unstructured":"Rajpura A, Kendoff D, Board TN (2014) The current state of bearing surfaces in total hip replacement. Bone Joint J 96-B(2):147\u2013156. doi: 10.1302\/0301-620X.96B2.31920","journal-title":"Bone Joint J"},{"key":"3217_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-015-2953-x","author":"J Hochreiter","year":"2015","unstructured":"Hochreiter J, Brusaferri G, Kirschbichler K, Emmanuel K (2015) Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system. Int Orthop. doi: 10.1007\/s00264-015-2953-x","journal-title":"Int Orthop"},{"issue":"8 Suppl","key":"3217_CR6","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.arth.2012.03.048","volume":"27","author":"CA Engh Jr","year":"2012","unstructured":"Engh CA Jr, Hopper RH Jr, Huynh C, Ho H, Sritulanondha S, Engh CA Sr (2012) A prospective, randomized study of cross-linked and non-cross-linked polyethylene for total hip arthroplasty at 10-year follow-up. J Arthroplasty 27(8 Suppl):2\u20137. doi: 10.1016\/j.arth.2012.03.048 , e1","journal-title":"J Arthroplasty"},{"issue":"7","key":"3217_CR7","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1016\/j.arth.2005.03.033","volume":"20","author":"DW Manning","year":"2005","unstructured":"Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20(7):880\u2013886. doi: 10.1016\/j.arth.2005.03.033","journal-title":"J Arthroplasty"},{"issue":"8","key":"3217_CR8","doi-asserted-by":"publisher","first-page":"716","DOI":"10.2106\/jbjs.j.00287","volume":"93","author":"GE Thomas","year":"2011","unstructured":"Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Gill HS, Murray DW, Glyn-Jones S (2011) The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am 93(8):716\u2013722. doi: 10.2106\/jbjs.j.00287","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"3217_CR9","doi-asserted-by":"publisher","first-page":"1961","DOI":"10.1016\/j.arth.2014.05.008","volume":"29","author":"NA Bedard","year":"2014","unstructured":"Bedard NA, Callaghan JJ, Stefl MD, Willman TJ, Liu SS, Goetz DD (2014) Fixation and wear with a contemporary acetabular component and cross-linked polyethylene at minimum 10-year follow-up. J Arthroplasty 29(10):1961\u20131969. doi: 10.1016\/j.arth.2014.05.008","journal-title":"J Arthroplasty"},{"issue":"4","key":"3217_CR10","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1007\/s11999-008-0628-2","volume":"467","author":"CH Geerdink","year":"2009","unstructured":"Geerdink CH, Grimm B, Vencken W, Heyligers IC, Tonino AJ (2009) Cross-linked compared with historical polyethylene in THA: an 8-year clinical study. Clin Orthop Relat Res 467(4):979\u2013984. doi: 10.1007\/s11999-008-0628-2","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"3217_CR11","doi-asserted-by":"publisher","first-page":"773","DOI":"10.2106\/jbjs.h.00244","volume":"91","author":"RW McCalden","year":"2009","unstructured":"McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD (2009) Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg Am 91(4):773\u2013782. doi: 10.2106\/jbjs.h.00244","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"3217_CR12","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1302\/0301-620X.93B5.25908","volume":"93","author":"PR Kuzyk","year":"2011","unstructured":"Kuzyk PR, Saccone M, Sprague S, Simunovic N, Bhandari M, Schemitsch EH (2011) Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials. J Bone Joint Surg (Br) 93(5):593\u2013600. doi: 10.1302\/0301-620X.93B5.25908","journal-title":"J Bone Joint Surg (Br)"},{"issue":"8","key":"3217_CR13","doi-asserted-by":"publisher","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","volume":"469","author":"SM Kurtz","year":"2011","unstructured":"Kurtz SM, Gawel HA, Patel JD (2011) History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 469(8):2262\u20132277. doi: 10.1007\/s11999-011-1872-4","journal-title":"Clin Orthop Relat Res"},{"key":"3217_CR14","first-page":"20","volume":"121","author":"JG DeLee","year":"1976","unstructured":"DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20\u201332","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"3217_CR15","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.arth.2004.08.008","volume":"20","author":"DM Estok 2nd","year":"2005","unstructured":"Estok DM 2nd, Bragdon CR, Plank GR, Huang A, Muratoglu OK, Harris WH (2005) The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene. J Arthroplasty 20(2):239\u2013243","journal-title":"J Arthroplasty"},{"issue":"4","key":"3217_CR16","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.orthres.2003.11.001","volume":"22","author":"KH Widmer","year":"2004","unstructured":"Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22(4):815\u2013821. doi: 10.1016\/j.orthres.2003.11.001","journal-title":"J Orthop Res"},{"issue":"21","key":"3217_CR17","doi-asserted-by":"crossref","first-page":"2835","DOI":"10.1016\/S0142-9612(01)00027-8","volume":"22","author":"EB Benz","year":"2001","unstructured":"Benz EB, Federman M, Godleski JJ, Bierbaum BE, Thornhill TS, Spector M (2001) Transmission electron microscopy of intracellular particles of polyethylene from joint replacement prostheses: size distribution and cellular response. Biomaterials 22(21):2835\u20132842","journal-title":"Biomaterials"},{"issue":"6 Suppl 2","key":"3217_CR18","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.arth.2006.05.002","volume":"21","author":"CA Engh Jr","year":"2006","unstructured":"Engh CA Jr, Stepniewski AS, Ginn SD, Beykirch SE, Sychterz-Terefenko CJ, Hopper RH Jr, Engh CA (2006) A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 21(6 Suppl 2):17\u201325. doi: 10.1016\/j.arth.2006.05.002","journal-title":"J Arthroplasty"},{"issue":"12","key":"3217_CR19","doi-asserted-by":"publisher","first-page":"3228","DOI":"10.1007\/s11999-010-1379-4","volume":"468","author":"J Mutimer","year":"2010","unstructured":"Mutimer J, Devane PA, Adams K, Horne JG (2010) Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years. Clin Orthop Relat Res 468(12):3228\u20133233. doi: 10.1007\/s11999-010-1379-4","journal-title":"Clin Orthop Relat Res"},{"key":"3217_CR20","doi-asserted-by":"publisher","first-page":"710621","DOI":"10.1155\/2013\/710621","volume":"2013","author":"TB Pace","year":"2013","unstructured":"Pace TB, Keith KC, Alvarez E, Snider RG, Tanner SL, Desjardins JD (2013) Comparison of conventional polyethylene wear and signs of cup failure in two similar total hip designs. Adv Orthop 2013:710621. doi: 10.1155\/2013\/710621","journal-title":"Adv Orthop"},{"issue":"5","key":"3217_CR21","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1054\/arth.2002.33664","volume":"17","author":"JH Dumbleton","year":"2002","unstructured":"Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17(5):649\u2013661","journal-title":"J Arthroplasty"},{"issue":"1","key":"3217_CR22","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1002\/jbm.b.31638","volume":"94","author":"J Gallo","year":"2010","unstructured":"Gallo J, Slouf M, Goodman SB (2010) The relationship of polyethylene wear to particle size, distribution, and number: a possible factor explaining the risk of osteolysis after hip arthroplasty. J Biomed Mater Res B Appl Biomater 94(1):171\u2013177. doi: 10.1002\/jbm.b.31638","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"2","key":"3217_CR23","doi-asserted-by":"crossref","first-page":"87","DOI":"10.55095\/achot2010\/017","volume":"77","author":"D Pokorny","year":"2010","unstructured":"Pokorny D, Slouf M, Vesely F, Fulin P, Jahoda D, Sosna A (2010) Distribution of UHMWPE wear particles in periprosthetic tissues of total hip replacements. Acta Chir Orthop Traumatol Cechoslov 77(2):87\u201392","journal-title":"Acta Chir Orthop Traumatol Cechoslov"},{"issue":"6","key":"3217_CR24","doi-asserted-by":"crossref","first-page":"864","DOI":"10.2106\/00004623-199274060-00007","volume":"74","author":"PC Peters Jr","year":"1992","unstructured":"Peters PC Jr, Engh GA, Dwyer KA, Vinh TN (1992) Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg Am 74(6):864\u2013876","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"3217_CR25","doi-asserted-by":"crossref","first-page":"849","DOI":"10.2106\/00004623-199274060-00006","volume":"74","author":"TP Schmalzried","year":"1992","unstructured":"Schmalzried TP, Jasty M, Harris WH (1992) Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 74(6):849\u2013863","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"3217_CR26","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1002\/(SICI)1097-4636(1999)48:3<374::AID-JBM23>3.0.CO;2-O","volume":"48","author":"SP James","year":"1999","unstructured":"James SP, Lee KR, Beauregard GP, Rentfrow ED, McLaughlin JR (1999) Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: effect of starting resin and forming method. J Biomed Mater Res 48(3):374\u2013384","journal-title":"J Biomed Mater Res"},{"issue":"2","key":"3217_CR27","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1007\/s11999-010-1571-6","volume":"469","author":"JB Meding","year":"2011","unstructured":"Meding JB, Keating EM, Davis KE (2011) Acetabular UHMWPE survival and wear changes with different manufacturing techniques. Clin Orthop Relat Res 469(2):405\u2013411. doi: 10.1007\/s11999-010-1571-6","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"3217_CR28","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1002\/jbm.a.32161","volume":"90","author":"A Jedenmalm","year":"2009","unstructured":"Jedenmalm A, Affatato S, Taddei P, Leardini W, Gedde UW, Fagnano C, Viceconti M (2009) Effect of head surface roughness and sterilization on wear of UHMWPE acetabular cups. J Biomed Mater Res A 90(4):1032\u20131042. doi: 10.1002\/jbm.a.32161","journal-title":"J Biomed Mater Res A"},{"issue":"4","key":"3217_CR29","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1023\/A:1008836107186","volume":"9","author":"M Goldman","year":"1998","unstructured":"Goldman M, Gronsky R, Pruitt L (1998) The influence of sterilization technique and ageing on the structure and morphology of medical-grade ultrahigh molecular weight polyethylene. J Mater Sci Mater Med 9(4):207\u2013212","journal-title":"J Mater Sci Mater Med"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-016-3217-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-016-3217-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-016-3217-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-016-3217-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,18]],"date-time":"2023-08-18T06:01:21Z","timestamp":1692338481000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-016-3217-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,13]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["3217"],"URL":"https:\/\/doi.org\/10.1007\/s00264-016-3217-0","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,13]]}}}