{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:55:35Z","timestamp":1792428935199,"version":"4.5.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2018,9,8]],"date-time":"2018-09-08T00:00:00Z","timestamp":1536364800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s00264-018-4110-9","type":"journal-article","created":{"date-parts":[[2018,9,8]],"date-time":"2018-09-08T04:04:59Z","timestamp":1536379499000},"page":"2161-2166","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Subcutaneous internal anterior fixation of pelvis fractures\u2014which configuration of the InFix is clinically optimal?\u2014a retrospective study"],"prefix":"10.1007","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8943-5817","authenticated-orcid":false,"given":"Julian","family":"Scherer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Tiziani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Sprengel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans-Christoph","family":"Pape","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georg","family":"Osterhoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,9,8]]},"reference":[{"issue":"1","key":"4110_CR1","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.ocl.2010.08.004","volume":"42","author":"P Bates","year":"2011","unstructured":"Bates P, Gary J, Singh G, Reinert C, Starr A (2011) Percutaneous treatment of pelvic and acetabular fractures in obese patients. Orthop Clin N Am 42(1):55\u201367 vi","journal-title":"Orthop Clin N Am"},{"issue":"3","key":"4110_CR2","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1097\/01.TA.0000053397.33827.DD","volume":"54","author":"PR Miller","year":"2003","unstructured":"Miller PR, Moore PS, Mansell E, Meredith JW, Chang MC (2003) External fixation or arteriogram in bleeding pelvic fracture: initial therapy guided by markers of arterial hemorrhage. J Trauma 54(3):437\u2013443","journal-title":"J Trauma"},{"issue":"5","key":"4110_CR3","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/j.injury.2004.11.016","volume":"36","author":"WT Mason","year":"2005","unstructured":"Mason WT, Khan SN, James CL, Chesser TJ, Ward AJ (2005) Complications of temporary and definitive external fixation of pelvic ring injuries. Injury 36(5):599\u2013604","journal-title":"Injury"},{"issue":"1","key":"4110_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/BOT.0b013e318233b8a7","volume":"26","author":"R Vaidya","year":"2012","unstructured":"Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A (2012) Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma 26(1):1\u20138","journal-title":"J Orthop Trauma"},{"key":"4110_CR5","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1186\/1756-0500-7-133","volume":"7","author":"MJ Scheyerer","year":"2014","unstructured":"Scheyerer MJ, Zimmermann SM, Osterhoff G, Tiziani S, Simmen HP, Wanner GA, Werner CM (2014) Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures. BMC Res Notes 7:133","journal-title":"BMC Res Notes"},{"key":"4110_CR6","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/1471-2474-15-111","volume":"15","author":"G Osterhoff","year":"2014","unstructured":"Osterhoff G, Tiziani S, Ferguson SJ, Spreiter G, Scheyerer MJ, Spinas GL, Wanner GA, Simmen HP, Werner CM (2014) Mechanical testing of a device for subcutaneous internal anterior pelvic ring fixation versus external pelvic ring fixation. BMC Musculoskelet Disord 15:111","journal-title":"BMC Musculoskelet Disord"},{"issue":"9","key":"4110_CR7","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.1007\/s00264-017-3415-4","volume":"41","author":"C Fang","year":"2017","unstructured":"Fang C, Alabdulrahman H, Pape HC (2017) Complications after percutaneous internal fixator for anterior pelvic ring injuries. Int Orthop 41(9):1785\u20131790","journal-title":"Int Orthop"},{"issue":"3","key":"4110_CR8","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1097\/BOT.0000000000000193","volume":"29","author":"D Hesse","year":"2015","unstructured":"Hesse D, Kandmir U, Solberg B, Stroh A, Osgood G, Sems SA, Collinge CA (2015) Femoral nerve palsy after pelvic fracture treated with INFIX: a case series. J Orthop Trauma 29(3):138\u2013143","journal-title":"J Orthop Trauma"},{"issue":"7","key":"4110_CR9","doi-asserted-by":"publisher","first-page":"561","DOI":"10.2106\/JBJS.15.01022","volume":"98","author":"D Rudin","year":"2016","unstructured":"Rudin D, Manestar M, Ullrich O, Erhardt J, Grob K (2016) The anatomical course of the lateral femoral cutaneous nerve with special attention to the anterior approach to the hip joint. J Bone Joint Surg Am 98(7):561\u2013567","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"4110_CR10","doi-asserted-by":"publisher","first-page":"2162","DOI":"10.1016\/j.injury.2017.08.047","volume":"48","author":"G Osterhoff","year":"2017","unstructured":"Osterhoff G, Aichner EV, Scherer J, Simmen HP, Werner CML, Feigl GC (2017) Anterior subcutaneous internal fixation of the pelvis - what rod-to-bone distance is anatomically optimal? Injury 48(10):2162\u20132168","journal-title":"Injury"},{"key":"4110_CR11","doi-asserted-by":"publisher","unstructured":"Schmitz P, Baumann F, Acklin YP, Gueorguiev B, Nerlich M, Grechenig S, Muller MB (2018) Clinical application of a minimally invasive cement-augmentable Schanz screw rod system to treat pelvic ring fractures. Int Orthop. \n                    https:\/\/doi.org\/10.1007\/s00264-018-3988-6","DOI":"10.1007\/s00264-018-3988-6"},{"key":"4110_CR12","first-page":"9468285","volume":"2016","author":"R Vaidya","year":"2016","unstructured":"Vaidya R, Nasr K, Feria-Arias E, Fisher R, Kajy M, Diebel LN (2016) INFIX\/EXFIX: massive open pelvic injuries and review of the literature. Case Rep Orthop 2016:9468285","journal-title":"Case Rep Orthop"},{"key":"4110_CR13","doi-asserted-by":"publisher","unstructured":"Blum L, Hake ME, Charles R, Conlan T, Rojas D, Martin MT, Mauffrey C (2018) Vertical shear pelvic injury: evaluation, management, and fixation strategies. Int Orthop. \n                    https:\/\/doi.org\/10.1007\/s00264-018-3883-1","DOI":"10.1007\/s00264-018-3883-1"},{"issue":"9","key":"4110_CR14","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1007\/s00264-017-3532-0","volume":"41","author":"L Cai","year":"2017","unstructured":"Cai L, Lou Y, Guo X, Wang J (2017) Surgical treatment of unstable pelvic fractures with concomitant acetabular fractures. Int Orthop 41(9):1803\u20131811","journal-title":"Int Orthop"},{"issue":"3","key":"4110_CR15","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1007\/s00264-017-3728-3","volume":"42","author":"X Wu","year":"2018","unstructured":"Wu X (2018) A biomechanical comparison of different fixation techniques for fractures of the acetabular posterior wall. Int Orthop 42(3):673\u2013679","journal-title":"Int Orthop"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-018-4110-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00264-018-4110-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-018-4110-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,7]],"date-time":"2019-09-07T19:25:09Z","timestamp":1567884309000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00264-018-4110-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,8]]},"references-count":15,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["4110"],"URL":"https:\/\/doi.org\/10.1007\/s00264-018-4110-9","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,8]]},"assertion":[{"value":"20 April 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was carried out in accordance with the local institutional ethics committee\u2019s terms of reference (Kantonale Ethikkommission Z\u00fcrich, Switzerland. BASEC-Nr. 2016-01954).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}