{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T22:01:09Z","timestamp":1773352869054,"version":"3.50.1"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,6,21]],"date-time":"2020-06-21T00:00:00Z","timestamp":1592697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,21]],"date-time":"2020-06-21T00:00:00Z","timestamp":1592697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s00264-020-04657-z","type":"journal-article","created":{"date-parts":[[2020,6,21]],"date-time":"2020-06-21T01:03:27Z","timestamp":1592701407000},"page":"2101-2112","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Open reduction and internal fixation of three- and four-part proximal humeral fractures by intrafocal distraction: a clinical and radiographic study of thirty-two cases with five to ten years of follow-up"],"prefix":"10.1007","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0629-0921","authenticated-orcid":false,"given":"Levon","family":"Doursounian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julien","family":"Gaillard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Lauthe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alain","family":"Sautet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adeline","family":"Cambon-Binder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,6,21]]},"reference":[{"key":"4657_CR1","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1067\/mse.2002.124346","volume":"11","author":"CMS Neer II","year":"2002","unstructured":"Neer CMS II (2002) Four-segment classification of proximal humeral fractures: purpose and reliable use. J Shoulder Elbow Surg 11:389\u2013400","journal-title":"J Shoulder Elbow Surg"},{"issue":"9","key":"4657_CR2","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.1007\/s00264-017-3569-0","volume":"41","author":"LL Nowak","year":"2017","unstructured":"Nowak LL, Vicente MR, McKee MD, Hall JA, Nauth A (2017 Sep) Schemitsch EH (2017) Orthopaedic surgeons\u2019 opinions surrounding the management of proximal humerus fractures: an international survey. Int Orthop 41(9):1749\u20131755. https:\/\/doi.org\/10.1007\/s00264-017-3569-0","journal-title":"Int Orthop"},{"key":"4657_CR3","doi-asserted-by":"publisher","first-page":"251","DOI":"10.2106\/JBJS.L.01293","volume":"96","author":"D Maier","year":"2014","unstructured":"Maier D, Jaeger M, Izadpanah K, Strohm PC, Suedkamp NP (2014) Proximal humeral fracture treatment in adults. J Bone Joint Surg Am 96:251\u2013261. https:\/\/doi.org\/10.2106\/JBJS.L.01293","journal-title":"J Bone Joint Surg Am"},{"key":"4657_CR4","doi-asserted-by":"publisher","first-page":"1689","DOI":"10.2106\/JBJS.H.00133","volume":"91","author":"BD Solberg","year":"2009","unstructured":"Solberg BD, Moon CN, Franco DP, Paiement GD (2009) Surgical treatment of three and four-part proximal humeral fractures. J Bone Joint Surg Am 91:1689\u20131697. https:\/\/doi.org\/10.2106\/JBJS.H.00133","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"4657_CR5","doi-asserted-by":"publisher","first-page":"2373","DOI":"10.1007\/s00264-015-3109-8","volume":"40","author":"L Doursounian","year":"2016","unstructured":"Doursounian L, Le Sant A, Mauprivez R, Miquel A, Beauthier-Landauer V (2016) Open reduction and internal fixation ofthree- and four-part proximal humeral fractures by intra-focal distraction: observational study of twenty-five cases. Int Orthop 40(11):2373\u20132382","journal-title":"Int Orthop"},{"key":"4657_CR6","doi-asserted-by":"crossref","unstructured":"Freese H, Volas MG, Wood JR (2001) Metallurgy and technological properties of titanium and titanium alloys applications in titanium in medicine springer-Verlag D-69121 Heidelberg, 26-49","DOI":"10.1007\/978-3-642-56486-4_3"},{"key":"4657_CR7","doi-asserted-by":"crossref","unstructured":"Perren MS, Pohler OE, Schneider E. (2001) Titanium as implant material for osteosynthesis applications in titanium in medicine Springer-Verlag D-69121 Heidelberg, 783\u2013800","DOI":"10.1007\/978-3-642-56486-4_23"},{"key":"4657_CR8","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/s40729-019-0162-x","volume":"5","author":"KT Kim","year":"2019","unstructured":"Kim KT, Eo MY, Nguyen TTH, Kim SM (2019) General review of titanium toxicity. Int J Implant Dent 5:10. https:\/\/doi.org\/10.1186\/s40729-019-0162-x","journal-title":"Int J Implant Dent"},{"issue":"6","key":"4657_CR9","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1586\/erd.10.53","volume":"7","author":"JS Hayes","year":"2010","unstructured":"Hayes JS, Richards RG (2010) The use of titanium and stainless steel in fracture fixation. Expert Rev Med Devices 7(6):843\u2013853","journal-title":"Expert Rev Med Devices"},{"key":"4657_CR10","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1302\/0301-620X.79B4.0790695c","volume":"79","author":"CR Constant","year":"1997","unstructured":"Constant CR (1997) An evaluation of the Constant-Murley shoulder assessment. J Bone Joint Surg Br 79:695\u2013696","journal-title":"J Bone Joint Surg Br"},{"key":"4657_CR11","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1097\/00003086-198607000-00007","volume":"208","author":"RL Cruess","year":"1986","unstructured":"Cruess RL (1986) Osteonecrosis of bone. Current concepts as to aetiology and pathogenesis. Clin Orthop Relat Res 208:30\u201339","journal-title":"Clin Orthop Relat Res"},{"key":"4657_CR12","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.2106\/JBJS.H.00006","volume":"91","author":"N S\u00fcdkamp","year":"2009","unstructured":"S\u00fcdkamp N, Bayer J, Hepp P, Voigt C, Oestern H, K\u00e4\u00e4b M, Luo C, Plecko M, Wendt K, K\u00f6stler W, Konrad G (2009) Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91:1320\u20131328. https:\/\/doi.org\/10.2106\/JBJS.H.00006","journal-title":"J Bone Joint Surg Am"},{"key":"4657_CR13","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.jse.2009.06.004","volume":"18","author":"C Thanasas","year":"2009","unstructured":"Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P (2009) Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elb Surg 18:837\u2013844. https:\/\/doi.org\/10.1016\/j.jse.2009.06.004","journal-title":"J Shoulder Elb Surg"},{"key":"4657_CR14","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","volume":"21","author":"MJ Gardner","year":"2007","unstructured":"Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG (2007) The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma 21:185\u2013191","journal-title":"J Orthop Trauma"},{"key":"4657_CR15","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1302\/0301-620X.86B6.14577","volume":"86","author":"C Gerber","year":"2004","unstructured":"Gerber C, Werner CM, Vienne P (2004) Internal fixation of complex fractures of the proximal humerus. J Bone Joint Surg Br 86:848\u2013855","journal-title":"J Bone Joint Surg Br"},{"key":"4657_CR16","doi-asserted-by":"publisher","first-page":"1724","DOI":"10.1016\/j.injury.2012.06.029","volume":"43","author":"SH Kim","year":"2012","unstructured":"Kim SH, Lee YH, Chung SW, Shin SH, Jang WY, Gong HS, Baek GH (2012) Outcomes for four-part proximal humerus fractures treated with a locking compression plate and an autologous iliac bone impaction graft. Injury. 43:1724\u20131731. https:\/\/doi.org\/10.1016\/j.injury.2012.06.029","journal-title":"Injury."},{"key":"4657_CR17","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.jse.2008.06.014","volume":"18","author":"CW Lee","year":"2009","unstructured":"Lee CW, Shin SJ (2009) Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Shoulder Elb Surg 18:83\u201388. https:\/\/doi.org\/10.1016\/j.jse.2008.06.014","journal-title":"J Shoulder Elb Surg"},{"key":"4657_CR18","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1007\/s00264-011-1227-5","volume":"35","author":"L Zhang","year":"2011","unstructured":"Zhang L, Zheng J, Wang W, Lin G, Huang Y, Zheng J, Edem Prince GA, Yang G (2011) The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study. Int Orthop 35:1655\u20131661. https:\/\/doi.org\/10.1007\/s00264-011-1227-5","journal-title":"Int Orthop"},{"key":"4657_CR19","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.otsr.2010.06.015","volume":"97","author":"L Doursounian","year":"2011","unstructured":"Doursounian L, Kilinc A, Cherrier B, Nourissat G (2011) Complex proximal humeral fractures: a prospective study of 22 cases treated using the \"Bilboquet\" device. Orthop Traumatol Surg Res 97:58\u201366. https:\/\/doi.org\/10.1016\/j.otsr.2010.06.015","journal-title":"Orthop Traumatol Surg Res"},{"key":"4657_CR20","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1067\/mse.2000.106086","volume":"9","author":"L Doursounian","year":"2000","unstructured":"Doursounian L, Grimberg J, Cazeau C, Jos E, Touzard RC (2000) A new internal fixation technique for fractures of the proximal humerus--the Bilboquet device: a report on 26 cases. J Shoulder Elb Surg 9:279\u2013278","journal-title":"J Shoulder Elb Surg"},{"key":"4657_CR21","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1302\/0301-620X.73B2.2005159","volume":"73","author":"RP Jakob","year":"1991","unstructured":"Jakob RP, Miniaci A, Anson PS, Jaberg H, Osterwalder A, Ganz R (1991) Four-part valgus impacted fractures of the proximal humerus. J Bone Joint Surg Br 73:295\u2013298","journal-title":"J Bone Joint Surg Br"},{"key":"4657_CR22","doi-asserted-by":"crossref","unstructured":"Geetha M, Singh AK, R.Asokamani, Gogia AK (2009) Ti based biomaterials, the ultimate choice for orthopaedic implants-a review. Prog Mater Sci 54(3): p. 397\u2013425","DOI":"10.1016\/j.pmatsci.2008.06.004"},{"issue":"2","key":"4657_CR23","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1002\/1521-4052(200102)32:2<137::AID-MAWE137>3.0.CO;2-7","volume":"32","author":"V Biehl","year":"2001","unstructured":"Biehl V, Breme J (2001) Metallic biomaterials. Mater Werkst 32(2):137\u2013141","journal-title":"Mater Werkst"},{"key":"4657_CR24","unstructured":"Malekani J, Schmutz B, Gu Y, Schuetz M (2011) Biomaterials in orthopedic bone plates: a review, 2nd Annual International Conference on Materials Science, Metal & Manufacturing, pp. 71-77"},{"key":"4657_CR25","doi-asserted-by":"crossref","unstructured":"Zheng-Ming Huang, K. Fujihara, (2005), Stiffness and strength design of composite bone plates, Compos Sci Technol, Vol. 65, pp73\u201385","DOI":"10.1016\/j.compscitech.2004.06.006"},{"key":"4657_CR26","doi-asserted-by":"crossref","unstructured":"Huiskes R, Weinans H, van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res (274):124\u2013134","DOI":"10.1097\/00003086-199201000-00014"},{"issue":"1\u20132","key":"4657_CR27","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","volume":"243","author":"M Niinomi","year":"1998","unstructured":"Niinomi M (1998) Mechanical properties of biomedical titanium alloys. Mater Sci Eng A 243(1\u20132):231\u2013236","journal-title":"Mater Sci Eng A"},{"issue":"12","key":"4657_CR28","doi-asserted-by":"publisher","first-page":"1685","DOI":"10.1007\/s00402-017-2790-z","volume":"137","author":"FJP Beeres","year":"2017","unstructured":"Beeres FJP, Hallensleben NDL, Rhemrev SJ, Goslings JC, Oehme F, Meylaerts SAG, Babst R, Schep NWL (2017) Plate fixation of the proximal humerus: an international multicentre comparative study of postoperative complications. Arch Orthop Trauma Surg 137(12):1685\u20131692. https:\/\/doi.org\/10.1007\/s00402-017-2790-z","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"4657_CR29","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.jse.2018.07.019","volume":"28","author":"M Chivot","year":"2019","unstructured":"Chivot M, Lami D, Bizzozero P, Galland A, Argenson JN (2019) Three- and four-part displaced proximal humeral fractures in patients older than 70 years: reverse shoulder arthroplasty or nonsurgical treatment? J Shoulder Elb Surg 28(2):252\u2013259. https:\/\/doi.org\/10.1016\/j.jse.2018.07.019","journal-title":"J Shoulder Elb Surg"},{"issue":"3","key":"4657_CR30","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1302\/0301-620X.99B3.BJJ-2016-1028","volume":"99-B","author":"HH Handoll","year":"2017","unstructured":"Handoll HH, Keding A, Corbacho B, Brealey SD, Hewitt C, Rangan A (2017) Five-year follow-up results of the PROFHER trial comparing operative and non-operative treatment of adults with a displaced fracture of the proximal humerus. Bone Joint J 99-B(3):383\u2013392. https:\/\/doi.org\/10.1302\/0301-620X.99B3.BJJ-2016-1028","journal-title":"Bone Joint J"},{"issue":"11","key":"4657_CR31","doi-asserted-by":"publisher","first-page":"1974","DOI":"10.1016\/j.injury.2019.09.019","volume":"50","author":"P Luciani","year":"2019","unstructured":"Luciani P, Farinelli L, Procaccini R, Verducci C, Gigante A (2019) Primary reverse shoulder arthroplasty for acute proximal humerus fractures: A 5-year long term retrospective study of elderly patients. Injury 50(11):1974\u20131977. https:\/\/doi.org\/10.1016\/j.injury.2019.09.019","journal-title":"Injury"},{"issue":"12","key":"4657_CR32","doi-asserted-by":"publisher","first-page":"2259","DOI":"10.1016\/j.jse.2019.06.024","volume":"28","author":"Y Lopiz","year":"2019","unstructured":"Lopiz Y, Alcob\u00eda-D\u00edaz B, Gal\u00e1n-Olleros M, Garc\u00eda-Fern\u00e1ndez C, Picado AL, Marco F (2019) Reverse shoulder arthroplasty versus nonoperative treatment for 3- or 4-part proximal humeral fractures in elderly patients: a prospective randomized controlled trial. J Shoulder Elb Surg 28(12):2259\u20132271. https:\/\/doi.org\/10.1016\/j.jse.2019.06.024","journal-title":"J Shoulder Elb Surg"},{"issue":"5","key":"4657_CR33","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.otsr.2019.03.019","volume":"105","author":"D Gallinet","year":"2019","unstructured":"Gallinet D, Cazeneuve JF, Boyer E, Menu G, Obert L, Ohl X, Bonnevialle N, Valenti P, Boileau P, Soci\u00e9t\u00e9 Fran\u00e7aise de Chirurgie Orthop\u00e9dique et Traumatologique (SoFCOT) (2019) Reverse shoulder arthroplasty for recent proximal humerus fractures: Outcomes in 422 cases. Orthop Traumatol Surg Res 105(5):805\u2013811. https:\/\/doi.org\/10.1016\/j.otsr.2019.03.019","journal-title":"Orthop Traumatol Surg Res"},{"issue":"8","key":"4657_CR34","doi-asserted-by":"publisher","first-page":"e3","DOI":"10.2106\/JBJS.RVW.17.00152","volume":"6","author":"JJ Jauregui","year":"2018","unstructured":"Jauregui JJ, Nadarajah V, Shield WP 3rd, Henn RF 3rd, Gilotra M, Hasan SA (2018) Reverse shoulder arthroplasty: perioperative considerations and complications. JBJS Rev 6(8):e3. https:\/\/doi.org\/10.2106\/JBJS.RVW.17.00152","journal-title":"JBJS Rev"},{"key":"4657_CR35","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1007\/s00264-013-1832-6","volume":"37","author":"MM Scarlat","year":"2013","unstructured":"Scarlat MM (2013) Complications with reverse total shoulder arthroplasty and recent evolutions. Int Orthop 37:843\u2013851. https:\/\/doi.org\/10.1007\/s00264-013-1832-6","journal-title":"Int Orthop"},{"key":"4657_CR36","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.jse.2004.01.034","volume":"13","author":"R Hertel","year":"2004","unstructured":"Hertel R, Hempfing A, Stiehler M, Leunig M (2004) Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. J Shoulder Elb Surg 13:427\u2013433","journal-title":"J Shoulder Elb Surg"},{"key":"4657_CR37","doi-asserted-by":"publisher","first-page":"1878","DOI":"10.1016\/j.injury.2015.06.026","volume":"46","author":"S Patel","year":"2015","unstructured":"Patel S, Colaco HB, Elvey ME, Lee MH (2015) Post-traumatic osteonecrosis of the proximal humerus. Injury 46:1878\u20131884","journal-title":"Injury"},{"key":"4657_CR38","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1016\/S1058-2746(98)90005-2","volume":"7","author":"C Gerber","year":"1998","unstructured":"Gerber C, Hersche O, Berberat C (1998) The clinical relevance of posttraumatic avascular necrosis the humeral head. J Shoulder Elb Surg 7:586\u2013590","journal-title":"J Shoulder Elb Surg"},{"key":"4657_CR39","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/S1058-2746(95)80015-8","volume":"4","author":"P Schai","year":"1995","unstructured":"Schai P, Imhoff A, Preiss S (1995) Comminuted humeral fractures: a multicenter analysis. J Shoulder Elb Surg 4:319\u2013330","journal-title":"J Shoulder Elb Surg"},{"issue":"5","key":"4657_CR40","doi-asserted-by":"publisher","first-page":"1155","DOI":"10.1007\/s00264-018-39","volume":"43","author":"L Doursounian","year":"2019","unstructured":"Doursounian L, Gaillard J, Cambon-Binder A, Zbili D, Sautet A (2019) Hemiarthroplasty for proximal humerus fractures with conservation of the whole humeral head as autograft: does it improve greater tuberosity healing? Int Orthop 43(5):1155\u20131164. https:\/\/doi.org\/10.1007\/s00264-018-39","journal-title":"Int Orthop"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-020-04657-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-020-04657-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-020-04657-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,29]],"date-time":"2022-10-29T17:17:07Z","timestamp":1667063827000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-020-04657-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,21]]},"references-count":40,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["4657"],"URL":"https:\/\/doi.org\/10.1007\/s00264-020-04657-z","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,21]]},"assertion":[{"value":"12 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The first author is the inventor of the device.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}