{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T01:19:00Z","timestamp":1768785540299,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T00:00:00Z","timestamp":1658188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T00:00:00Z","timestamp":1658188800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"the training project of academic leaders of health and family planning committee of Shanghai Pudong new area","award":["PWRd2019-09"],"award-info":[{"award-number":["PWRd2019-09"]}]},{"name":"the clinical peak discipline construction project of Shanghai Pudong new area","award":["PWYgf2018-05"],"award-info":[{"award-number":["PWYgf2018-05"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1007\/s00264-022-05516-9","type":"journal-article","created":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T07:03:08Z","timestamp":1658214188000},"page":"2393-2403","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Should cannulated screws be removed after a femoral neck fracture has healed, and how? A finite element analysis of the femur before and after cannulated screw removal"],"prefix":"10.1007","volume":"46","author":[{"given":"Le","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qing","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuo","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1516-0213","authenticated-orcid":false,"given":"Lifeng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,19]]},"reference":[{"key":"5516_CR1","doi-asserted-by":"publisher","first-page":"2527","DOI":"10.1007\/s00198-011-1888-3","volume":"23","author":"RO St\u00f8en","year":"2012","unstructured":"St\u00f8en RO, Nordsletten L, Meyer HE, Frihagen JF, Falch JA, Lofthus CM (2012) Hip fracture incidence is decreasing in the high incidence area of Oslo, Norway. Osteoporos Int 23:2527\u20132534. https:\/\/doi.org\/10.1007\/s00198-011-1888-3","journal-title":"Osteoporos Int"},{"key":"5516_CR2","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.ocl.2010.01.001","volume":"41","author":"JA Lowe","year":"2010","unstructured":"Lowe JA, Crist BD, Bhandari M, Ferguson TA (2010) Optimal treatment of femoral neck fractures according to patient\u2019s physiologic age: an evidence-based review. Orthop Clin North Am 41:157\u2013166. https:\/\/doi.org\/10.1016\/j.ocl.2010.01.001","journal-title":"Orthop Clin North Am"},{"key":"5516_CR3","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s40001-021-00556-0","volume":"26","author":"H Fischer","year":"2021","unstructured":"Fischer H, Maleitzke T, Eder C, Ahmad S, St\u00f6ckle U, Braun KF (2021) Management of proximal femur fractures in the elderly: current concepts and treatment options. Eur J Med Res 26:86. https:\/\/doi.org\/10.1186\/s40001-021-00556-0","journal-title":"Eur J Med Res"},{"key":"5516_CR4","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1186\/1471-2474-9-73","volume":"9","author":"B Hanson","year":"2008","unstructured":"Hanson B, van der Werken C, Stengel D (2008) Surgeons\u2019 beliefs and perceptions about removal of orthopaedic implants. BMC Musculoskelet Disord 9:73. https:\/\/doi.org\/10.1186\/1471-2474-9-73","journal-title":"BMC Musculoskelet Disord"},{"key":"5516_CR5","doi-asserted-by":"publisher","first-page":"e285","DOI":"10.1097\/BOT.0000000000000358","volume":"29","author":"SM Zielinski","year":"2015","unstructured":"Zielinski SM, Heetveld MJ, Bhandari M, Patka P, Van Lieshout EM, Trial Investigators FAITH (2015) Implant removal after internal fixation of a femoral neck fracture: effects on physical functioning. J Orthop Trauma 29:e285-292. https:\/\/doi.org\/10.1097\/BOT.0000000000000358","journal-title":"J Orthop Trauma"},{"key":"5516_CR6","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1007\/s00776-012-0331-8","volume":"18","author":"ZS Ai","year":"2013","unstructured":"Ai ZS, Gao YS, Sun Y, Liu Y, Zhang CQ, Jiang CH (2013) Logistic regression analysis of factors associated with avascular necrosis of the femoral head following femoral neck fractures in middle-aged and elderly patients. J Orthop Sci 18:271\u2013276. https:\/\/doi.org\/10.1007\/s00776-012-0331-8","journal-title":"J Orthop Sci"},{"key":"5516_CR7","doi-asserted-by":"publisher","first-page":"1271762","DOI":"10.1155\/2018\/1271762","volume":"2018","author":"J Li","year":"2018","unstructured":"Li J, Wang M, Zhou J, Han L, Zhang H, Li C, Li L, Hao M (2018) Optimum configuration of cannulated compression screws for the fixation of unstable femoral neck fractures: finite element analysis evaluation. Biomed Res Int 2018:1271762. https:\/\/doi.org\/10.1155\/2018\/1271762","journal-title":"Biomed Res Int"},{"key":"5516_CR8","first-page":"40","volume":"44","author":"KS Song","year":"2015","unstructured":"Song KS, Lee SW (2015) Subtrochanteric femur fracture after removal of screws for femoral neck fracture in a child. Am J Orthop 44:40\u201342","journal-title":"Am J Orthop"},{"key":"5516_CR9","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1097\/BOT.0b013e31829906a0","volume":"27","author":"PW Yoon","year":"2013","unstructured":"Yoon PW, Kwon JE, Yoo JJ, Kim HJ, Yoon KS (2013) Femoral neck fracture after removal of the compression hip screw from healed intertrochanteric fractures. J Orthop Trauma 27:696\u2013701. https:\/\/doi.org\/10.1097\/BOT.0b013e31829906a0","journal-title":"J Orthop Trauma"},{"key":"5516_CR10","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1007\/s00402-020-03435-1","volume":"140","author":"MLS Driessen","year":"2020","unstructured":"Driessen MLS, Goessens MLMJ (2020) Complications of implant removal after healed hip fractures. Arch Orthop Trauma Surg 140:1745\u20131749. https:\/\/doi.org\/10.1007\/s00402-020-03435-1","journal-title":"Arch Orthop Trauma Surg"},{"key":"5516_CR11","doi-asserted-by":"publisher","first-page":"e177","DOI":"10.3346\/jkms.2021.36.e177","volume":"36","author":"JT Hines","year":"2021","unstructured":"Hines JT, Jo WL, Cui Q, Mont MA, Koo KH, Cheng EY, Goodman SB, Ha YC, Hernigou P, Jones LC, Kim SY, Sakai T, Sugano N, Yamamoto T, Lee MS, Zhao D, Drescher W, Kim TY, Lee YK, Yoon BH, Baek SH, Ando W, Kim HS, Park JW (2021) Osteonecrosis of the femoral head: an updated review of ARCO on pathogenesis, staging and treatment. J Korean Med Sci 36:e177. https:\/\/doi.org\/10.3346\/jkms.2021.36.e177","journal-title":"J Korean Med Sci"},{"key":"5516_CR12","doi-asserted-by":"publisher","first-page":"e65","DOI":"10.3346\/jkms.2021.36.e65","volume":"36","author":"Q Cui","year":"2021","unstructured":"Cui Q, Jo WL, Koo KH, Cheng EY, Drescher W, Goodman SB, Ha YC, Hernigou P, Jones LC, Kim SY, Lee KS, Lee MS, Lee YJ, Mont MA, Sugano N, Taliaferro J, Yamamoto T, Zhao D (2021) ARCO consensus on the pathogenesis of non-traumatic osteonecrosis of the femoral head. J Korean Med Sci 36:e65. https:\/\/doi.org\/10.3346\/jkms.2021.36.e65","journal-title":"J Korean Med Sci"},{"key":"5516_CR13","doi-asserted-by":"publisher","first-page":"e83","DOI":"10.3928\/01477447-20111122-34","volume":"35","author":"JA Shaer","year":"2012","unstructured":"Shaer JA, Hileman BM, Newcomer JE, Hanes MC (2012) Femoral neck fracture following hardware removal. Orthopedics 35:e83-87. https:\/\/doi.org\/10.3928\/01477447-20111122-34","journal-title":"Orthopedics"},{"key":"5516_CR14","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1016\/s0021-9290(97)00057-2","volume":"30","author":"GN Duda","year":"1997","unstructured":"Duda GN, Schneider E, Chao EY (1997) Internal forces and moments in the femur during walking. J Biomech 30:933\u2013941. https:\/\/doi.org\/10.1016\/s0021-9290(97)00057-2","journal-title":"J Biomech"},{"key":"5516_CR15","doi-asserted-by":"publisher","first-page":"113","DOI":"10.5435\/00124635-200602000-00006","volume":"14","author":"ML Busam","year":"2006","unstructured":"Busam ML, Esther RJ, Obremskey WT (2006) Hardware removal: indications and expectations. J Am Acad Orthop Surg 14:113\u2013120. https:\/\/doi.org\/10.5435\/00124635-200602000-00006","journal-title":"J Am Acad Orthop Surg"},{"key":"5516_CR16","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1055\/s-0039-1693046","volume":"54","author":"A Freitas","year":"2019","unstructured":"Freitas A, Ramos LS, Dantas \u00c9L, Giordano Neto V, Godinho PF, Shimano AC (2019) Biomechanical test after hip cannulated screw removal (in vitro analysis). Rev Bras Ortop 54:416\u2013421. https:\/\/doi.org\/10.1055\/s-0039-1693046","journal-title":"Rev Bras Ortop"},{"key":"5516_CR17","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1002\/ar.1049","volume":"262","author":"HM Frost","year":"2001","unstructured":"Frost HM (2001) From Wolff\u2019s law to the Utah paradigm: insights about bone physiology and its clinical applications. Anat Rec 262:398\u2013419. https:\/\/doi.org\/10.1002\/ar.1049","journal-title":"Anat Rec"},{"key":"5516_CR18","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1016\/j.clinbiomech.2010.12.002","volume":"26","author":"S Eberle","year":"2011","unstructured":"Eberle S, Wutte C, Bauer C, von Oldenburg G, Augat P (2011) Should extramedullary fixations for hip fractures be removed after bone union? Clin Biomech 26:410\u2013414. https:\/\/doi.org\/10.1016\/j.clinbiomech.2010.12.002","journal-title":"Clin Biomech"},{"key":"5516_CR19","doi-asserted-by":"publisher","first-page":"e468","DOI":"10.3928\/01477447-20130327-24","volume":"36","author":"LJ Patman","year":"2013","unstructured":"Patman LJ, Szalay EA (2013) Relative osteopenia after femoral implant removal in children and adolescents. Orthopedics 36:e468-472. https:\/\/doi.org\/10.3928\/01477447-20130327-24","journal-title":"Orthopedics"},{"key":"5516_CR20","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1007\/s00198-013-2487-2","volume":"25","author":"SM Zielinski","year":"2014","unstructured":"Zielinski SM, Bouwmans CA, Heetveld MJ, Bhandari M, Patka P, Van Lieshout EM, FAITH trial investigators (2014) The societal costs of femoral neck fracture patients treated with internal fixation. Osteoporos Int 25:875\u2013885. https:\/\/doi.org\/10.1007\/s00198-013-2487-2","journal-title":"Osteoporos Int"},{"key":"5516_CR21","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/0020-1383(91)90100-s","volume":"22","author":"J Rosson","year":"1991","unstructured":"Rosson J, Murphy W, Tonge C, Shearer J (1991) Healing of residual screw holes after plate removal. Injury 22:383\u2013384. https:\/\/doi.org\/10.1016\/0020-1383(91)90100-s","journal-title":"Injury"},{"key":"5516_CR22","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.2106\/00004623-197254060-00001","volume":"54","author":"AH Burstein","year":"1972","unstructured":"Burstein AH, Currey J, Frankel VH, Heiple KG, Lunseth P, Vessely JC (1972) Bone strength. The effect of screw holes. J Bone Joint Surg Am 54:1143\u20131156","journal-title":"J Bone Joint Surg Am"},{"key":"5516_CR23","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1097\/00005131-200303000-00013","volume":"17","author":"P Kloen","year":"2003","unstructured":"Kloen P, Rubel IF, Lyden JP, Helfet DL (2003) Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: a report of four cases. J Orthop Trauma 17:225\u2013229. https:\/\/doi.org\/10.1097\/00005131-200303000-00013","journal-title":"J Orthop Trauma"},{"key":"5516_CR24","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1097\/00003086-198504000-00034","volume":"194","author":"RK Karr","year":"1985","unstructured":"Karr RK, Schwab JP (1985) Subtrochanteric fracture as a complication of proximal femoral pinning. Clin Orthop Relat Res 194:214\u2013217","journal-title":"Clin Orthop Relat Res"},{"key":"5516_CR25","doi-asserted-by":"publisher","first-page":"507","DOI":"10.2106\/00004623-197052030-00008","volume":"52","author":"DB Brooks","year":"1970","unstructured":"Brooks DB, Burstein AH, Frankel VH (1970) The biomechanics of torsional fractures. The stress concentration effect of a drill hole. J Bone Joint Surg Am 52:507\u2013514","journal-title":"J Bone Joint Surg Am"},{"key":"5516_CR26","doi-asserted-by":"publisher","first-page":"809136","DOI":"10.4061\/2011\/809136","volume":"2011","author":"M Paloski","year":"2011","unstructured":"Paloski M, Taylor BC, Willits M (2011) Subtrochanteric femur fracture after slipped capital femoral epiphysis pinning: a novel treatment. Adv Orthop 2011:809136. https:\/\/doi.org\/10.4061\/2011\/809136","journal-title":"Adv Orthop"},{"key":"5516_CR27","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1097\/00004694-199703000-00014","volume":"17","author":"ST Canale","year":"1997","unstructured":"Canale ST, Casillas M, Banta JV (1997) Displaced femoral neck fractures at the bone-screw interface after in situ fixation of slipped capital femoral epiphysis. J Pediatr Orthop 17:212\u2013215. https:\/\/doi.org\/10.1097\/00004694-199703000-00014","journal-title":"J Pediatr Orthop"},{"key":"5516_CR28","doi-asserted-by":"publisher","first-page":"1827","DOI":"10.1007\/s00264-021-05039-9","volume":"45","author":"K Ding","year":"2021","unstructured":"Ding K, Yang W, Wang H, Zhan S, Hu P, Bai J, Ren C, Zhang Q, Zhu Y, Chen W (2021) Finite element analysis of biomechanical effects of residual varus\/valgus malunion after femoral fracture on knee joint. Int Orthop 45:1827\u20131835. https:\/\/doi.org\/10.1007\/s00264-021-05039-9","journal-title":"Int Orthop"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-022-05516-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-022-05516-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-022-05516-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T09:22:19Z","timestamp":1663752139000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-022-05516-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,19]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["5516"],"URL":"https:\/\/doi.org\/10.1007\/s00264-022-05516-9","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,19]]},"assertion":[{"value":"16 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by Shanghai East Hospital ethics committee and performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from all the participants for the publication of this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}