{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:18:27Z","timestamp":1786979907222,"version":"build-2736575974"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T00:00:00Z","timestamp":1701129600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T00:00:00Z","timestamp":1701129600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100008426","name":"DePuy Mitek","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008426","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2024,3]]},"DOI":"10.1007\/s00264-023-06041-z","type":"journal-article","created":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T06:02:49Z","timestamp":1701151369000},"page":"643-649","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Knot holding capacity of two different high-strength sutures\u2014a biomechanical analysis"],"prefix":"10.1007","volume":"48","author":[{"given":"Kenneth P.","family":"van Knegsel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Zderic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Kastner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Varga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Knobe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Till","family":"Berk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyko","family":"Gueorguiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4357-236X","authenticated-orcid":false,"given":"Torsten","family":"Pastor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,28]]},"reference":[{"key":"6041_CR1","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1016\/j.arthro.2014.05.030","volume":"30","author":"D Hurwit","year":"2014","unstructured":"Hurwit D, Fanton G, Tella M et al (2014) Viscoelastic properties of common suture material used for rotator cuff repair and arthroscopic procedures. Arthroscopy 30:1406\u20131412. https:\/\/doi.org\/10.1016\/j.arthro.2014.05.030","journal-title":"Arthroscopy"},{"key":"6041_CR2","doi-asserted-by":"publisher","first-page":"2607","DOI":"10.1016\/j.jbiomech.2016.05.023","volume":"49","author":"MC Jordan","year":"2016","unstructured":"Jordan MC, Boelch S, Jansen H et al (2016) Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials. J Biomech 49:2607\u20132612. https:\/\/doi.org\/10.1016\/j.jbiomech.2016.05.023","journal-title":"J Biomech"},{"key":"6041_CR3","unstructured":"Algeri JA, Me B DYNACORDTM Suture: comparative monitoring of the compression force using pressure film. 2.\u00a0https:\/\/www.jnjmedtech.com\/system\/files\/pdf\/115003-210422%20-%20DYNACORD%20Compress%20%281%29.pdf"},{"key":"6041_CR4","unstructured":"Bhattacharyya S, Mafilios M, Spenciner D, Algeri J DYNACORDTM Suture: comparative evaluation of knot security in a mechanical model. 2.\u00a0http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/INT%20Mobile\/Synthes%20International\/Product%20Support%20Material\/legacy_DePuy_Mitek_PDFs\/102997.pdf"},{"key":"6041_CR5","doi-asserted-by":"publisher","first-page":"2849","DOI":"10.1007\/s00167-013-2452-9","volume":"22","author":"S Neuhofer","year":"2014","unstructured":"Neuhofer S, Wieser K, Lajtai G et al (2014) Surgical knot tightening: how much pull is necessary? Knee Surg Sports Traumatol Arthrosc 22:2849\u20132855. https:\/\/doi.org\/10.1007\/s00167-013-2452-9","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6041_CR6","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1111\/vsu.12627","volume":"46","author":"M Coleridge","year":"2017","unstructured":"Coleridge M, Gillen AM, Farag R et al (2017) Effect of fluid media on the mechanical properties of continuous pattern-ending surgeon\u2019s, square, and Aberdeen knots in vitro. Vet Surg 46:306\u2013315. https:\/\/doi.org\/10.1111\/vsu.12627","journal-title":"Vet Surg"},{"key":"6041_CR7","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.arthro.2019.08.048","volume":"36","author":"ME Taha","year":"2020","unstructured":"Taha ME, Schneider K, Clarke EC et al (2020) A biomechanical comparison of different suture materials used for arthroscopic shoulder procedures. Arthroscopy 36:708\u2013713. https:\/\/doi.org\/10.1016\/j.arthro.2019.08.048","journal-title":"Arthroscopy"},{"key":"6041_CR8","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1111\/j.1748-5827.2009.00771.x","volume":"50","author":"O Schaaf","year":"2009","unstructured":"Schaaf O, Glyde M, Day RE (2009) A secure Aberdeen knot: in vitro assessment of knot security in plasma and fat. J Small Anim Pract 50:415\u2013421. https:\/\/doi.org\/10.1111\/j.1748-5827.2009.00771.x","journal-title":"J Small Anim Pract"},{"key":"6041_CR9","doi-asserted-by":"publisher","first-page":"709","DOI":"10.2460\/ajvr.80.7.709","volume":"80","author":"L McGlinchey","year":"2019","unstructured":"McGlinchey L, Boone LH, Munsterman AS et al (2019) In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat. Am J Vet Res 80:709\u2013716. https:\/\/doi.org\/10.2460\/ajvr.80.7.709","journal-title":"Am J Vet Res"},{"key":"6041_CR10","doi-asserted-by":"publisher","first-page":"680","DOI":"10.2106\/JBJS.H.00110","volume":"91","author":"AW Mack","year":"2009","unstructured":"Mack AW, Freedman BA, Shawen SB et al (2009) Wound complications following the use of FiberWire in lower-extremity traumatic amputations. A case series. J Bone Joint Surg Am 91:680\u2013685. https:\/\/doi.org\/10.2106\/JBJS.H.00110","journal-title":"J Bone Joint Surg Am"},{"key":"6041_CR11","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jse.2018.05.043","volume":"28","author":"PJ Favorito","year":"2019","unstructured":"Favorito PJ, Spenciner DB, Muench TR et al (2019) Safety evaluation of a laxity-minimizing suture at 5 days and 6 weeks after repair of a sheep infraspinatus tendon. J Shoulder Elbow Surg 28:164\u2013169. https:\/\/doi.org\/10.1016\/j.jse.2018.05.043","journal-title":"J Shoulder Elbow Surg"},{"key":"6041_CR12","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1007\/s00590-017-2114-6","volume":"28","author":"E Hohmann","year":"2018","unstructured":"Hohmann E, K\u00f6nig A, Kat C-J et al (2018) Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors. A systematic review and meta-analysis of basic biomechanical studies. Eur J Orthop Surg Traumatol 28:859\u2013868. https:\/\/doi.org\/10.1007\/s00590-017-2114-6","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"6041_CR13","doi-asserted-by":"publisher","first-page":"975","DOI":"10.2106\/00004623-199907000-00010","volume":"81","author":"RH Gelberman","year":"1999","unstructured":"Gelberman RH, Boyer MI, Brodt MD et al (1999) The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons. An experimental study on the early stages of tendon-healing in dogs. J Bone Joint Surg Am 81:975\u2013982. https:\/\/doi.org\/10.2106\/00004623-199907000-00010","journal-title":"J Bone Joint Surg Am"},{"key":"6041_CR14","unstructured":"Livermore RW, Chong ACM, Prohaska DJ, et al Knot security, loop security, and elongation of braided polyblend sutures used for arthroscopic knots. 8.\u00a0https:\/\/pubmed.ncbi.nlm.nih.gov\/21720573\/"},{"key":"6041_CR15","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.arthro.2004.03.005","volume":"20","author":"IKY Lo","year":"2004","unstructured":"Lo IKY, Burkhart SS, Chan KC, Athanasiou K (2004) Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthroscopy: J Arthroscopic Related Surg 20:489\u2013502. https:\/\/doi.org\/10.1016\/j.arthro.2004.03.005","journal-title":"Arthroscopy: J Arthroscopic Related Surg"},{"key":"6041_CR16","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1097\/00006250-198609000-00029","volume":"68","author":"JB Trimbos","year":"1986","unstructured":"Trimbos JB, Van Rijssel EJ, Klopper PJ (1986) Performance of sliding knots in monofilament and multifilament suture material. Obstet Gynecol 68:425\u2013430. https:\/\/doi.org\/10.1097\/00006250-198609000-00029","journal-title":"Obstet Gynecol"},{"key":"6041_CR17","doi-asserted-by":"publisher","first-page":"2407","DOI":"10.1177\/0363546508323745","volume":"36","author":"OA Ilahi","year":"2008","unstructured":"Ilahi OA, Younas SA, Ho DM, Noble PC (2008) Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid. Am J Sports Med 36:2407\u20132414. https:\/\/doi.org\/10.1177\/0363546508323745","journal-title":"Am J Sports Med"},{"key":"6041_CR18","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.jse.2015.07.018","volume":"25","author":"JF Williams","year":"2016","unstructured":"Williams JF, Patel SS, Baker DK et al (2016) Abrasiveness of high-strength sutures used in rotator cuff surgery: are they all the same? J Shoulder Elbow Surg 25:142\u2013148. https:\/\/doi.org\/10.1016\/j.jse.2015.07.018","journal-title":"J Shoulder Elbow Surg"},{"key":"6041_CR19","doi-asserted-by":"publisher","first-page":"e873","DOI":"10.1016\/j.asmr.2021.01.029","volume":"3","author":"P Borbas","year":"2021","unstructured":"Borbas P, Fischer L, Ernstbrunner L et al (2021) High-strength suture tapes are biomechanically stronger than high-strength sutures used in rotator cuff repair. ASMAR 3:e873\u2013e880. https:\/\/doi.org\/10.1016\/j.asmr.2021.01.029","journal-title":"ASMAR"},{"key":"6041_CR20","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1007\/s11999-016-4838-8","volume":"474","author":"RS Camenzind","year":"2016","unstructured":"Camenzind RS, Wieser K, Fessel G et al (2016) Tendon collagen crosslinking offers potential to improve suture pullout in rotator cuff repair: an ex vivo sheep study. Clin Orthop Relat Res 474:1778\u20131785. https:\/\/doi.org\/10.1007\/s11999-016-4838-8","journal-title":"Clin Orthop Relat Res"},{"key":"6041_CR21","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1302\/0301-620X.94B5.27642","volume":"94","author":"C Ortiz","year":"2012","unstructured":"Ortiz C, Wagner E, Moco\u00e7ain P et al (2012) Biomechanical comparison of four methods of repair of the Achilles tendon: a laboratory study with bovine tendons. J Bone Joint Surg Br 94:663\u2013667. https:\/\/doi.org\/10.1302\/0301-620X.94B5.27642","journal-title":"J Bone Joint Surg Br"},{"key":"6041_CR22","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1067\/mse.2003.21","volume":"12","author":"CA Cummins","year":"2003","unstructured":"Cummins CA, Murrell GAC (2003) Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elbow Surg 12:128\u2013133. https:\/\/doi.org\/10.1067\/mse.2003.21","journal-title":"J Shoulder Elbow Surg"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-023-06041-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-023-06041-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-023-06041-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T21:04:04Z","timestamp":1709154244000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-023-06041-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,28]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["6041"],"URL":"https:\/\/doi.org\/10.1007\/s00264-023-06041-z","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,28]]},"assertion":[{"value":"16 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in this study were followed in accordance with relevant guidelines.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The donor gave his informed consent inherent within the donation of the anatomical gift statement during his lifetime, as registered by Science Care.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}