{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T10:01:24Z","timestamp":1794045684502,"version":"4.8.0"},"reference-count":126,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T00:00:00Z","timestamp":1708128000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T00:00:00Z","timestamp":1708128000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Qatar Orthopaedic and Sports Medicine Hospital","id":[{"id":"https:\/\/ror.org\/00x6vsv29","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Wide-Awake Local Anaesthesia No Tourniquet (WALANT), a groundbreaking anaesthetic technique resurging in practice, warrants a comprehensive safety analysis for informed adoption. Our study aimed to identify complications\/side effects of WALANT upper limb procedures through a systematic review and meta-analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This PROSPERO-registered study was performed with strict adherence to PRISMA guidelines. Embase, OVIDMedline, Cochrane, Web of Science, and Scopus databases were searched until February 2023. Inclusion criteria involved English articles, reporting complications\/side effects in primary WALANT upper limb surgeries. Outcomes included all complications and side effects, data on the anaesthetic mixture, publication year\/location, study type, and procedures performed. The meta-analysis employed the Freeman-Tukey Double Arcsine Transformation, computed\n                      <jats:italic>I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      statistics, and utilized common or random effects models for pooled analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      2002 studies were identified; 79 studies met the inclusion criteria representing 15,595 WALANT patients. A total of 301 patients had complications, and the meta-analysis using a random effects model provided a complication rate of 1.7% (95% CI: 0.93\u20132.7%). The most reported complications were superficial infection (41%,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009123\/300), other\/specified (12%,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200937\/300), and recurrent disease (6.7%,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200920\/300). A decade-by-decade analysis revealed no statistically significant difference in complication rates spanning the last three decades (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.42). Adding sodium bicarbonate to the anaesthetic solution significantly reduced postoperative complications (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.025).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>WALANT has a low overall complication rate of 1.7%, with no significant temporal variation and a significant reduction in complications when sodium bicarbonate is added to the anaesthetic solution. Our findings support the safety of WALANT in upper limb procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Registration<\/jats:title>\n                    <jats:p>PROSPERO: CRD42023404018.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00264-024-06104-9","type":"journal-article","created":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T00:02:11Z","timestamp":1708128131000},"page":"1257-1269","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Complications and side effects of Wide-Awake Local Anaesthesia No Tourniquet (WALANT) in upper limb surgery: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"48","author":[{"given":"Jad","family":"Lawand","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashraf","family":"Hantouly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fadi","family":"Bouri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Muneer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulaziz","family":"Farooq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6667-2593","authenticated-orcid":false,"given":"Elisabet","family":"Hagert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,17]]},"reference":[{"key":"6104_CR1","unstructured":"Kurani N, Ortaliza J, Wager E, Fox L, Amin K. How has U.S. (2022) Spending on healthcare changed over time? Peterson-KFF health system tracker. https:\/\/www.healthsystemtracker.org\/chart-collection\/u-s-spending-healthcare-changed-time\/#Total%20national%20health%20expenditures,%20US%20$%20Billions,%201970-2022"},{"key":"6104_CR2","unstructured":"British Orthopedic Association (2022) T&O waiting list the largest for over a decade.\u00a0https:\/\/www.boa.ac.uk\/resource\/t-o-waiting-list-the-largest-for-over-a-decade.html."},{"issue":"8","key":"6104_CR3","doi-asserted-by":"publisher","first-page":"443","DOI":"10.5435\/JAAOS-21-08-443","volume":"21","author":"D Lalonde","year":"2013","unstructured":"Lalonde D, Martin A (2013) Epinephrine in local anesthesia in finger and hand surgery: the case for wide-awake anesthesia. J Am Acad Orthop Surg 21(8):443\u2013447. https:\/\/doi.org\/10.5435\/JAAOS-21-08-443","journal-title":"J Am Acad Orthop Surg"},{"issue":"6","key":"6104_CR4","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1590\/1516-3180.2020.0583.r2.0904221","volume":"139","author":"A Okamura","year":"2021","unstructured":"Okamura A, Moraes VY, Fernandes M, Raduan-Neto J, Belloti JC (2021) WALANT versus intravenous regional anesthesia for carpal tunnel syndrome: a randomized clinical trial. Sao Paulo Medical Journal Revista Paulista de Medicina 139(6):576\u2013578","journal-title":"Sao Paulo Medical Journal Revista Paulista de Medicina"},{"issue":"5","key":"6104_CR5","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1097\/PRS.0000000000006741","volume":"145","author":"E Ayhan","year":"2020","unstructured":"Ayhan E, Akaslan F (2020) Patients\u2019 perspective on carpal tunnel release with WALANT or intravenous regional anesthesia. Plast Reconstr Surg 145(5):1197\u20131203. https:\/\/doi.org\/10.1097\/PRS.0000000000006741","journal-title":"Plast Reconstr Surg"},{"issue":"3","key":"6104_CR6","doi-asserted-by":"publisher","first-page":"103134","DOI":"10.1016\/j.otsr.2021.103134","volume":"109","author":"L Moscato","year":"2023","unstructured":"Moscato L, Helmi A, Kouyoumdjian P, Lalonde D, Mares O (2023) The impact of WALANT anesthesia and office-based settings on patient satisfaction after carpal tunnel release: a patient reported outcome study. Orthopaedics & Traumatol, Surgery Res: OTSR 109(3):103134. https:\/\/doi.org\/10.1016\/j.otsr.2021.103134","journal-title":"Orthopaedics & Traumatol, Surgery Res: OTSR"},{"issue":"6","key":"6104_CR7","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1053\/j.jfas.2019.03.019","volume":"58","author":"J Stimpson","year":"2019","unstructured":"Stimpson J, Gill DF, Memarzadeh A, Dunne M, Perry L, Magan A, Devany A, Pasapula C (2019) Reducing the hypertensive effects of the prolonged surgical tourniquet using a dual-cuff strategy: a prospective randomized controlled trial. The J Foot Ankle Surg 58(6):1177\u20131186. https:\/\/doi.org\/10.1053\/j.jfas.2019.03.019","journal-title":"The J Foot Ankle Surg"},{"issue":"4","key":"6104_CR8","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1016\/0363-5023(91)90183-c","volume":"16","author":"RA Pedowitz","year":"1991","unstructured":"Pedowitz RA, Gershuni DH, Schmidt AH, Frid\u00e9n J, Rydevik BL, Hargens AR (1991) Muscle injury induced beneath and distal to a pneumatic tourniquet: a quantitative animal study of effects of tourniquet pressure and duration. The J Hand Surg 16(4):610\u2013621. https:\/\/doi.org\/10.1016\/0363-5023(91)90183-c","journal-title":"The J Hand Surg"},{"issue":"5","key":"6104_CR9","doi-asserted-by":"publisher","first-page":"e4285","DOI":"10.1097\/GOX.0000000000004285","volume":"10","author":"TC Oakes","year":"2022","unstructured":"Oakes TC, Wong KC, Schank KJ, Haan P, Bray SM, Clarkson JHW (2022) Infection rate comparison during transition from hospital to office WALANT enabled by virtual reality. Plast Reconstr Surg Glob Open 10(5):e4285. https:\/\/doi.org\/10.1097\/GOX.0000000000004285","journal-title":"Plast Reconstr Surg Glob Open"},{"issue":"1","key":"6104_CR10","doi-asserted-by":"publisher","first-page":"e12876","DOI":"10.7759\/cureus.12876","volume":"13","author":"MH Abd Hamid","year":"2021","unstructured":"Abd Hamid MH, Abdullah S, Ahmad AA, Narin Singh PSG, Soh EZF, Liu CY, Sapuan J (2021) A randomized controlled trial comparing wide-awake local anesthesia with no tourniquet (WALANT) to general anesthesia in plating of distal radius fractures with pain and anxiety level perception. Cureus 13(1):e12876. https:\/\/doi.org\/10.7759\/cureus.12876","journal-title":"Cureus"},{"issue":"1","key":"6104_CR11","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.jhsg.2022.10.003","volume":"5","author":"AM Far-Riera","year":"2022","unstructured":"Far-Riera AM, Perez-Uribarri C, Serrano MJE, Gonz\u00e1lez JMR (2022) Impact of WALANT hand surgery in a secondary care hospital in Spain Benefits to the patient and the health system. J Hand Surg Global Online 5(1):73\u201379","journal-title":"J Hand Surg Global Online"},{"issue":"10","key":"6104_CR12","doi-asserted-by":"publisher","first-page":"1624","DOI":"10.3390\/life12101624","volume":"12","author":"T Apard","year":"2022","unstructured":"Apard T, Odoemene M, Descamps J (2022) Wrist hemiarthroplasty of irreparable distal radius fracture under wide-awake local anesthetic and no tourniquet. Life (Basel, Switzerland) 12(10):1624. https:\/\/doi.org\/10.3390\/life12101624","journal-title":"Life (Basel, Switzerland)"},{"issue":"7","key":"6104_CR13","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1302\/2046-3758.97.BJR-2019-0315.R1","volume":"9","author":"M Tahir","year":"2020","unstructured":"Tahir M, Chaudhry EA, Zaffar Z, Anwar K, Mamoon MAH, Ahmad M, Jamali AR, Mehboob G (2020) Fixation of distal radius fractures using wide-awake local anaesthesia with no tourniquet (WALANT) technique: a randomized control trial of a cost-effective and resource-friendly procedure. Bone & Joint Res 9(7):429\u2013439. https:\/\/doi.org\/10.1302\/2046-3758.97.BJR-2019-0315.R1","journal-title":"Bone & Joint Res"},{"issue":"1","key":"6104_CR14","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1186\/s13018-021-02319-3","volume":"16","author":"J Xu","year":"2021","unstructured":"Xu J, Yin L, Cao S, Zhan H, Zhang J, Zhou Q, Gong K (2021) Application of WALANT technique for repairing finger skin defect with a random skin flap. J Orthop Surg Res 16(1):164. https:\/\/doi.org\/10.1186\/s13018-021-02319-3","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"6104_CR15","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1097\/PRS.0b013e3181e60489","volume":"126","author":"A Higgins","year":"2010","unstructured":"Higgins A, Lalonde DH, Bell M, McKee D, Lalonde JF (2010) Avoiding flexor tendon repair rupture with intraoperative total active movement examination. Plast Reconstr Surg 126(3):941\u2013945. https:\/\/doi.org\/10.1097\/PRS.0b013e3181e60489","journal-title":"Plast Reconstr Surg"},{"issue":"2","key":"6104_CR16","doi-asserted-by":"publisher","first-page":"88","DOI":"10.14712\/23362936.2022.9","volume":"123","author":"G Georgieva","year":"2022","unstructured":"Georgieva G, Srbov B, Nikolovska B, Tusheva S, Jovanovska K, Jovanoski T, Dzonov B, Gjorgova ST, Pejkova S (2022) WALANT as an optimal approach in hand surgery during pandemics. Prague Med Report 123(2):88\u201394. https:\/\/doi.org\/10.14712\/23362936.2022.9","journal-title":"Prague Med Report"},{"issue":"1","key":"6104_CR17","doi-asserted-by":"publisher","first-page":"e2022013","DOI":"10.23750\/abm.v93i1.12134","volume":"93","author":"A Sutcliffe","year":"2022","unstructured":"Sutcliffe A, Khera B, Khashaba H (2022) Wide-awake local anaesthesia no tourniquet (WALANT) procedures during COVID: a single centre experience. Acta bio-medica\u202f: Atenei Parmensis 93(1):e2022013. https:\/\/doi.org\/10.23750\/abm.v93i1.12134","journal-title":"Acta bio-medica : Atenei Parmensis"},{"issue":"3","key":"6104_CR18","doi-asserted-by":"publisher","first-page":"e36728","DOI":"10.7759\/cureus.36728","volume":"15","author":"R Bamal","year":"2023","unstructured":"Bamal R, Alnobani O, Bastouros E, Nolan G, Morris E, Griffiths S, Bell D (2023) Wide-awake local anesthesia no tourniquet (WALANT) for flexor tendon repairs as change in practice during the COVID-19 pandemic: a retrospective cohort study with outcomes. Cureus 15(3):e36728. https:\/\/doi.org\/10.7759\/cureus.36728","journal-title":"Cureus"},{"issue":"2","key":"6104_CR19","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.hansur.2021.12.002","volume":"41","author":"P Ruterana","year":"2022","unstructured":"Ruterana P, Abitbol A, Castel LC, Gregory T (2022) WALANT technique versus locoregional anesthesia in the surgical management of metacarpal and phalangeal fractures: Lessons from the Covid-19 crisis. Hand Surg Rehabilitation 41(2):220\u2013225. https:\/\/doi.org\/10.1016\/j.hansur.2021.12.002","journal-title":"Hand Surg Rehabilitation"},{"issue":"12","key":"6104_CR20","doi-asserted-by":"publisher","first-page":"e20.00100","DOI":"10.5435\/JAAOSGlobal-D-20-00100","volume":"4","author":"JJ Turcotte","year":"2020","unstructured":"Turcotte JJ, Petre BM, Jones CM, Gelfand JM (2020) Maintaining access to orthopaedic surgery during periods of operating room resource constraint: expanded use of wide-awake surgery during the COVID-19 pandemic. J Am Acad Orthop Surgeons Global Res Rev 4(12):e20.00100. https:\/\/doi.org\/10.5435\/JAAOSGlobal-D-20-00100","journal-title":"J Am Acad Orthop Surgeons Global Res Rev"},{"issue":"2","key":"6104_CR21","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1177\/15533506211003530","volume":"28","author":"JJ Turcotte","year":"2021","unstructured":"Turcotte JJ, Gelfand JM, Jones CM, Jackson RS (2021) Development of a low-resource operating room and a wide-awake orthopedic surgery program during the COVID-19 pandemic. Surgical Innov 28(2):183\u2013188. https:\/\/doi.org\/10.1177\/15533506211003530","journal-title":"Surgical Innov"},{"key":"6104_CR22","doi-asserted-by":"publisher","unstructured":"Clark DM, Dingle ME, Wade SM, Mescher PK, Nanos GP 3rd, Tintle SM (2023) Utilization of a clinic-based hand surgery procedure room in the US Military Health System: a performance improvement analysis of resource savings and patient satisfaction. J Hand Surg Am S0363-5023(23)00165-X. https:\/\/doi.org\/10.1016\/j.jhsa.2023.03.014","DOI":"10.1016\/j.jhsa.2023.03.014"},{"issue":"11","key":"6104_CR23","doi-asserted-by":"publisher","first-page":"e2509","DOI":"10.1097\/GOX.0000000000002509","volume":"7","author":"SG Maliha","year":"2019","unstructured":"Maliha SG, Cohen O, Jacoby A, Sharma S (2019) A cost and efficiency analysis of the WALANT technique for the management of trigger finger in a procedure room of a major city hospital. Plast Reconstr Surg Glob Open 7(11):e2509. https:\/\/doi.org\/10.1097\/GOX.0000000000002509","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"6104_CR24","doi-asserted-by":"publisher","DOI":"10.1177\/15589447221126764","author":"CW Long","year":"2022","unstructured":"Long CW, Wilson A, Daniels CL, Brown ME, Carreon L, Robinson L (2022) Improved resource utilization using WALANT hand surgery in sdolescents. Hand (N Y). https:\/\/doi.org\/10.1177\/15589447221126764","journal-title":"Hand (N Y)"},{"issue":"5","key":"6104_CR25","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.ijsu.2010.02.007","volume":"8","author":"D Moher","year":"2010","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group (2010) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg (London, England) 8(5):336\u2013341. https:\/\/doi.org\/10.1016\/j.ijsu.2010.02.007","journal-title":"Int J Surg (London, England)"},{"issue":"4","key":"6104_CR26","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1111\/jebm.12445","volume":"14","author":"SA Doi","year":"2021","unstructured":"Doi SA, Xu C (2021) The Freeman-Tukey double arcsine transformation for the meta-analysis of proportions: recent criticisms were seriously misleading. J Evid Based Med 14(4):259\u2013261. https:\/\/doi.org\/10.1111\/jebm.12445","journal-title":"J Evid Based Med"},{"issue":"7414","key":"6104_CR27","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses BMJ (Clinical research ed) 327(7414):557\u2013560. https:\/\/doi.org\/10.1136\/bmj.327.7414.557","journal-title":"Measuring inconsistency in meta-analyses BMJ (Clinical research ed)"},{"issue":"2","key":"6104_CR28","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.jhsg.2022.12.003","volume":"5","author":"S Abdullah","year":"2023","unstructured":"Abdullah S, Tokiran MF, Ahmad AA, Soh EZF, Makpol S, Sapuan J (2023) Safety of lidocaine during wide-awake local anesthesia no tourniquet for distal radius plating. J Hand Surg Global Online 5(2):196\u2013200. https:\/\/doi.org\/10.1016\/j.jhsg.2022.12.003","journal-title":"J Hand Surg Global Online"},{"issue":"3","key":"6104_CR29","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.hansur.2021.02.001","volume":"40","author":"A Abitbol","year":"2021","unstructured":"Abitbol A, Merlini L, Masmejean EH, Gregory T (2021) Applying the WALANT technique to surgical treatment of distal radius fractures. Hand Surg Rehab 40(3):277\u2013282. https:\/\/doi.org\/10.1016\/j.hansur.2021.02.001","journal-title":"Hand Surg Rehab"},{"issue":"2","key":"6104_CR30","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.hansur.2016.12.006","volume":"36","author":"T Apard","year":"2017","unstructured":"Apard T, Candelier G (2017) Wide-awake ultrasound-guided percutaneous extensor central slip tenotomy for chronic mallet finger: a prospective study of 14 cases (with videos). Hand Surg Rehab 36(2):86\u201389. https:\/\/doi.org\/10.1016\/j.hansur.2016.12.006","journal-title":"Hand Surg Rehab"},{"issue":"8","key":"6104_CR31","doi-asserted-by":"publisher","first-page":"1198","DOI":"10.1007\/s00270-022-03123-0","volume":"45","author":"T Apard","year":"2022","unstructured":"Apard T, Mares O, Duparc F, Michelin P (2022) Percutaneous Ultrasound-guided release of the lacertus fibrosus for median nerve entrapment at the elbow. Cardiovasc Intervent Radiol 45(8):1198\u20131202. https:\/\/doi.org\/10.1007\/s00270-022-03123-0","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"3","key":"6104_CR32","doi-asserted-by":"crossref","first-page":"156","DOI":"10.3113\/JSOA.2021.0156","volume":"30","author":"A Avoricani","year":"2021","unstructured":"Avoricani A, Dar QA, Levy KH, Koehler SM (2021) WALANT hand surgery: do the AORN guidelines apply? J Surg Orthop Adv 30(3):156\u2013160","journal-title":"J Surg Orthop Adv"},{"issue":"2","key":"6104_CR33","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1177\/22925503211003840","volume":"30","author":"A Avoricani","year":"2022","unstructured":"Avoricani A, Dar QA, Levy KH, Kurtzman JS, Koehler SM (2022) WALANT hand and upper extremity procedures performed with minor field sterility are associated with low infection rates. Plastic surgery (Oakville, Ont) 30(2):122\u2013129. https:\/\/doi.org\/10.1177\/22925503211003840","journal-title":"Plastic surgery (Oakville, Ont)"},{"issue":"6","key":"6104_CR34","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.jhsg.2022.05.001","volume":"4","author":"CE Bas","year":"2022","unstructured":"Bas CE, Ayhan E, Kunu O, Kuru CA (2022) Successful boutonniere reconstruction with wide-awake local anesthesia no tourniquet. J Hand Surg Global Online 4(6):421\u2013425. https:\/\/doi.org\/10.1016\/j.jhsg.2022.05.001","journal-title":"J Hand Surg Global Online"},{"issue":"8","key":"6104_CR35","doi-asserted-by":"publisher","first-page":"1606","DOI":"10.1016\/j.jhsa.2015.03.034","volume":"40","author":"MM Bashir","year":"2015","unstructured":"Bashir MM, Qayyum R, Saleem MH, Siddique K, Khan FA (2015) Effect of time interval between tumescent local anesthesia infiltration and start of surgery on operative field visibility in hand surgery without tourniquet. The J Hand Surg 40(8):1606\u20131609. https:\/\/doi.org\/10.1016\/j.jhsa.2015.03.034","journal-title":"The J Hand Surg"},{"issue":"3","key":"6104_CR36","doi-asserted-by":"publisher","first-page":"103358","DOI":"10.1016\/j.otsr.2022.103358","volume":"109","author":"B Boukebous","year":"2023","unstructured":"Boukebous B, Maillot C, Castel LC, Donadio J, Boyer P, Rousseau MA (2023) Wide awake local anesthesia no tourniquet (WALANT) versus axillary brachial plexus block for carpal tunnel release in a French public university hospital: care pathways and operating room costs. Orthopaedics & Traumatol Surg Res: OTSR 109(3):103358. https:\/\/doi.org\/10.1016\/j.otsr.2022.103358","journal-title":"Orthopaedics & Traumatol Surg Res: OTSR"},{"issue":"3","key":"6104_CR37","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1177\/15589447211030695","volume":"18","author":"ME Braza","year":"2023","unstructured":"Braza ME, Kelley JP, Kelpin JP, Fahrenkopf MP, Do VH (2023) Treatment of pyogenic flexor tenosynovitis in the emergency department setting with WALANT technique. Hand (New York, N.Y) 18(3):473\u2013477. https:\/\/doi.org\/10.1177\/15589447211030695","journal-title":"Hand (New York, N.Y)"},{"issue":"4","key":"6104_CR38","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1142\/S2424835519500486","volume":"24","author":"IJ Castro Magtoto","year":"2019","unstructured":"Castro Magtoto IJ, Alagar DL (2019) Wide awake local anesthesia no tourniquet: a pilot study for carpal tunnel release in the Philippine Orthopedic Center. The J Hand Surg Asian-Pacific 24(4):389\u2013391. https:\/\/doi.org\/10.1142\/S2424835519500486","journal-title":"The J Hand Surg Asian-Pacific"},{"issue":"6","key":"6104_CR39","doi-asserted-by":"publisher","first-page":"2031","DOI":"10.1097\/PRS.0b013e3181f44486","volume":"126","author":"S Chowdhry","year":"2010","unstructured":"Chowdhry S, Seidenstricker L, Cooney DS, Hazani R, Wilhelmi BJ (2010) Do not use epinephrine in digital blocks: myth or truth? Part II A retrospective review of 1111 cases. Plastic Reconstructive Surg 126(6):2031\u20132034","journal-title":"Plastic Reconstructive Surg"},{"issue":"3","key":"6104_CR40","doi-asserted-by":"publisher","first-page":"386","DOI":"10.22551\/MSJ.2021.03.09","volume":"125","author":"P Ciobanu","year":"2021","unstructured":"Ciobanu P, Poroch V, Moraru DC, Velenciuc N, Aladari N (2021) Wide awake local anesthesia no tourniquet technique in hand surgery during the COVID-19 pandemic\u2014personal experience. Medical-Surgical Journal-Revista Medico-Chirurgicala 125(3):386\u2013394","journal-title":"Medical-Surgical Journal-Revista Medico-Chirurgicala"},{"issue":"3","key":"6104_CR41","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1097\/01.prs.0000152420.64842.b6","volume":"115","author":"K Denkler","year":"2005","unstructured":"Denkler K (2005) Dupuytren\u2019s fasciectomies in 60 consecutive digits using lidocaine with epinephrine and no tourniquet. Plast Reconstr Surg 115(3):802\u2013810. https:\/\/doi.org\/10.1097\/01.prs.0000152420.64842.b6","journal-title":"Plast Reconstr Surg"},{"issue":"8","key":"6104_CR42","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/S0363-5023(11)60020-8","volume":"36","author":"KA Denkler","year":"2011","unstructured":"Denkler KA (2011) Needle fasciotomy for stage IV Dupuytren\u2019s: a wide-awake approach\u2014level 4 evidence. J Hand Surg 36(8):15\u201316","journal-title":"J Hand Surg"},{"issue":"5","key":"6104_CR43","doi-asserted-by":"publisher","first-page":"1033e","DOI":"10.1097\/PRS.0000000000009641","volume":"150","author":"KA Denkler","year":"2022","unstructured":"Denkler KA, Park KM (2022) Needle aponeurotomy for stage IV Dupuytren contracture: a wide-awake first step approach in 204 consecutive rays. Plast Reconstr Surg 150(5):1033e\u20131036e. https:\/\/doi.org\/10.1097\/PRS.0000000000009641","journal-title":"Plast Reconstr Surg"},{"issue":"8","key":"6104_CR44","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1177\/1753193420916418","volume":"45","author":"R Dukan","year":"2020","unstructured":"Dukan R, Krief E, Nizard R (2020) Distal radius fracture volar locking plate osteosynthesis using wide-awake local anaesthesia. The Journal of hand surgery, European 45(8):857\u2013863. https:\/\/doi.org\/10.1177\/1753193420916418","journal-title":"The Journal of hand surgery, European"},{"issue":"7","key":"6104_CR45","doi-asserted-by":"publisher","first-page":"734.e1","DOI":"10.1016\/j.jhsa.2022.01.015","volume":"48","author":"\u00c7 Duru","year":"2023","unstructured":"Duru \u00c7, Ya\u015far B, Ergani HM, Acicbe O, Utku \u00d6, \u00dcnl\u00fc RE (2023) Outcomes of wide-awake flexor tendon repairs in 58 fingers and 9 thumbs. The Journal of hand surgery 48(7):734.e1-734.e8. https:\/\/doi.org\/10.1016\/j.jhsa.2022.01.015","journal-title":"The Journal of hand surgery"},{"key":"6104_CR46","doi-asserted-by":"publisher","unstructured":"Enechukwu AOM, Bucher F, Dastagir K, Jokuszies A, Vogt PM, K\u00f6nneker S (2021) Treatment of hand infections using WALANT -when the anesthesiologist is not available: a retrospective cohort study. Ann Med Surg (Lond) 71:102993. https:\/\/doi.org\/10.1016\/j.amsu.2021.102993","DOI":"10.1016\/j.amsu.2021.102993"},{"issue":"1","key":"6104_CR47","doi-asserted-by":"publisher","first-page":"54e","DOI":"10.1097\/PRS.0000000000006902","volume":"146","author":"U Farkash","year":"2020","unstructured":"Farkash U, Herman A, Kalimian T, Segal O, Cohen A, Laish-Farkash A (2020) Keeping the finger on the pulse: cardiac arrhythmias in hand surgery using local anesthesia with adrenaline. Plast Reconstr Surg 146(1):54e\u201360e. https:\/\/doi.org\/10.1097\/PRS.0000000000006902","journal-title":"Plast Reconstr Surg"},{"issue":"1","key":"6104_CR48","first-page":"116","volume":"9","author":"R Farzam","year":"2021","unstructured":"Farzam R, Deilami M, Jalili S, Kamali K (2021) Comparison of anesthesia results between wide awake local anesthesia no tourniquet (WALANT) and forearm tourniquet bier block in hand surgeries: a randomized clinical trial. The Arch Bone Joint Surg 9(1):116\u2013121","journal-title":"The Arch Bone Joint Surg"},{"issue":"3","key":"6104_CR49","doi-asserted-by":"publisher","first-page":"230949901773949","DOI":"10.1177\/2309499017739499","volume":"25","author":"J Gunasagaran","year":"2017","unstructured":"Gunasagaran J, Sean ES, Shivdas S, Amir S, Ahmad TS (2017) Perceived comfort during minor hand surgeries with wide awake local anaesthesia no tourniquet (WALANT) versus local anaesthesia (LA)\/tourniquet. J Orthop Surg (Hong Kong) 25(3):2309499017739499. https:\/\/doi.org\/10.1177\/2309499017739499","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"6104_CR50","doi-asserted-by":"publisher","first-page":"9351354","DOI":"10.1155\/2020\/9351354","volume":"2020","author":"A Hernandez","year":"2020","unstructured":"Hernandez A, Rosario M, Mendoza-Torres R, Taguba CRM, Garcia A, Battad G (2020) Evaluating clinical outcomes for determining the optimal delay to skin incision under WALANT: a prospective series of 34 patients from a low-resource tertiary setting. Adv Orthop 2020:9351354. https:\/\/doi.org\/10.1155\/2020\/9351354","journal-title":"Adv Orthop"},{"issue":"3","key":"6104_CR51","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1097\/PRS.0000000000006611","volume":"145","author":"J Hong","year":"2020","unstructured":"Hong J, Kang HJ, Whang JI, Sung SY, Kim SH, Shin SC, Kim SN, Kim JS (2020) Comparison of the wide-awake approach and conventional approach in extensor indicis proprius-to-extensor pollicis longus tendon transfer for chronic extensor pollicis longus rupture. Plast Reconstr Surg 145(3):723\u2013733. https:\/\/doi.org\/10.1097\/PRS.0000000000006611","journal-title":"Plast Reconstr Surg"},{"issue":"6","key":"6104_CR52","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/j.jhsg.2022.02.004","volume":"4","author":"HM How","year":"2022","unstructured":"How HM, Khoo BLJ, Ayeop MAS, Ahmad AR, Bahaudin N, Ahmad AA (2022) Application of WALANT in diaphyseal plating of forearm fractures: an observational study. J Hand Surg Global Online 4(6):399\u2013407. https:\/\/doi.org\/10.1016\/j.jhsg.2022.02.004","journal-title":"J Hand Surg Global Online"},{"issue":"1","key":"6104_CR53","doi-asserted-by":"publisher","first-page":"e93","DOI":"10.3928\/01477447-20181206-01","volume":"42","author":"YC Huang","year":"2019","unstructured":"Huang YC, Chen CY, Lin KC, Yang SW, Tarng YW, Chang WN (2019) Comparison of wide-awake local anesthesia no tourniquet with general anesthesia with tourniquet for volar plating of distal radius fracture. Orthopedics 42(1):e93\u2013e98. https:\/\/doi.org\/10.3928\/01477447-20181206-01","journal-title":"Orthopedics"},{"issue":"1","key":"6104_CR54","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1186\/s13018-018-0903-1","volume":"13","author":"YC Huang","year":"2018","unstructured":"Huang YC, Hsu CJ, Renn JH, Lin KC, Yang SW, Tarng YW, Chang WN, Chen CY (2018) WALANT for distal radius fracture: open reduction with plating fixation via wide-awake local anesthesia with no tourniquet. J Orthop Surg Res 13(1):195. https:\/\/doi.org\/10.1186\/s13018-018-0903-1","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"6104_CR55","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.hansur.2021.10.312","volume":"41","author":"M Kadhum","year":"2022","unstructured":"Kadhum M, Georgiou A, Kanapathy M, Reissis D, Akhavani M, Burr N, Nikkhah D (2022) Operative outcomes for wide awake local anesthesia versus regional and general anesthesia for flexor tendon repair. Hand Surg Rehabilitation 41(1):125\u2013130. https:\/\/doi.org\/10.1016\/j.hansur.2021.10.312","journal-title":"Hand Surg Rehabilitation"},{"issue":"2","key":"6104_CR56","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/j.injury.2022.11.063","volume":"54","author":"MJ Kafiabadi","year":"2023","unstructured":"Kafiabadi MJ, Sabaghzadeh A, Biglari F, Sadighi M, Ebrahimpour A (2023) Effects of fixation of clavicle fracture using wide-awake local anesthesia no tourniquet (WALANT) technique on intra-operative bleeding volume, surgical duration, and post-operatively visual analog scale (VAS). A Case Series Study Injury 54(2):557\u2013560. https:\/\/doi.org\/10.1016\/j.injury.2022.11.063","journal-title":"A Case Series Study Injury"},{"key":"6104_CR57","doi-asserted-by":"publisher","first-page":"2725","DOI":"10.2147\/JPR.S210366","volume":"12","author":"SW Kang","year":"2019","unstructured":"Kang SW, Park HM, Park JK, Jeong HS, Cha JK, Go BS, Min KT (2019) Open cubital and carpal tunnel release using wide-awake technique: reduction of postoperative pain. J Pain Res 12:2725\u20132731. https:\/\/doi.org\/10.2147\/JPR.S210366","journal-title":"J Pain Res"},{"issue":"8","key":"6104_CR58","doi-asserted-by":"publisher","first-page":"1645","DOI":"10.1016\/j.otsr.2020.03.013","volume":"106","author":"S Ki Lee","year":"2020","unstructured":"Ki Lee S, Gul Kim S, Sik Choy W (2020) A randomized controlled trial of minor hand surgeries comparing wide awake local anesthesia no tourniquet and local anesthesia with tourniquet. Orthopaedics & Traumatol Surg Res: OTSR 106(8):1645\u20131651. https:\/\/doi.org\/10.1016\/j.otsr.2020.03.013","journal-title":"Orthopaedics & Traumatol Surg Res: OTSR"},{"issue":"1","key":"6104_CR59","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.jhsg.2019.09.011","volume":"2","author":"GR Lalchandani","year":"2019","unstructured":"Lalchandani GR, Halvorson RT, Rahgozar P, Immerman I (2019) Wide-awake local anesthesia for minor hand surgery associated with lower opioid prescriptions, morbidity, and costs: a nationwide database study. Journal of Hand Surg Global Online 2(1):7\u201312. https:\/\/doi.org\/10.1016\/j.jhsg.2019.09.011","journal-title":"Journal of Hand Surg Global Online"},{"issue":"2","key":"6104_CR60","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1177\/1753193420932465","volume":"46","author":"LP Larsen","year":"2021","unstructured":"Larsen LP, Hansen TB (2021) Total trapeziometacarpal joint arthroplasty using wide awake local anaesthetic no tourniquet. The J Hand Surg Europ 46(2):125\u2013130. https:\/\/doi.org\/10.1177\/1753193420932465","journal-title":"The J Hand Surg Europ"},{"issue":"6","key":"6104_CR61","doi-asserted-by":"publisher","first-page":"597","DOI":"10.5999\/aps.2020.01732","volume":"47","author":"S Lee","year":"2020","unstructured":"Lee S, Oh S, Son D (2020) Open carpal release using local anesthesia without a tourniquet: does bleeding tendency affect the outcome? Arch Plast Surg 47(6):597\u2013603. https:\/\/doi.org\/10.5999\/aps.2020.01732","journal-title":"Arch Plast Surg"},{"issue":"3","key":"6104_CR62","doi-asserted-by":"publisher","first-page":"103413","DOI":"10.1016\/j.otsr.2022.103413","volume":"109","author":"SK Lee","year":"2023","unstructured":"Lee SK, Kim SG, Kim H, Choy WS (2023) Carpal tunnel release under wide awake local anesthesia with no tourniquet in hemodialysis patients with arteriovenous shunt. Orthopaedics & Traumatol Surg Res: OTSR 109(3):103413. https:\/\/doi.org\/10.1016\/j.otsr.2022.103413","journal-title":"Orthopaedics & Traumatol Surg Res: OTSR"},{"issue":"1","key":"6104_CR63","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1186\/s12893-021-01362-5","volume":"21","author":"YC Lin","year":"2021","unstructured":"Lin YC, Chen WC, Chen CY, Kuo SM (2021) Plate osteosynthesis of single metacarpal fracture: WALANT technique is a cost-effective approach to reduce postoperative pain and discomfort in contrast to general anesthesia and wrist block. BMC Surg 21(1):358. https:\/\/doi.org\/10.1186\/s12893-021-01362-5","journal-title":"BMC Surg"},{"issue":"4","key":"6104_CR64","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.3390\/jcm11041123","volume":"11","author":"WC Liu","year":"2022","unstructured":"Liu WC, Lu IC, Chang CC, Chen CT, Chen CH, Shih CL, Fu YC, Jupiter JB (2022) Less fluctuation in hemodynamics of the wide-awake local anesthesia no tourniquet technique than general anesthesia in distal radius plating surgery: a prospective case-control study. J Clin Med 11(4):1123. https:\/\/doi.org\/10.3390\/jcm11041123","journal-title":"J Clin Med"},{"issue":"4","key":"6104_CR65","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.hansur.2022.03.003","volume":"41","author":"P Luciani","year":"2022","unstructured":"Luciani P, Delgove A, Pelissier P (2022) Retrospective evaluation of WALANT in emergency hand surgery in the Bordeaux university hospital. Hand Surg Rehabilitation 41(4):435\u2013440. https:\/\/doi.org\/10.1016\/j.hansur.2022.03.003","journal-title":"Hand Surg Rehabilitation"},{"issue":"1","key":"6104_CR66","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jhsg.2019.10.005","volume":"2","author":"TV Ly","year":"2019","unstructured":"Ly TV, Urban V, Meuli-Simmen C, Pasternak I (2019) Endoscopic carpal tunnel release using wide-awake anesthesia. J Hand Surg Global Online 2(1):13\u201315. https:\/\/doi.org\/10.1016\/j.jhsg.2019.10.005","journal-title":"J Hand Surg Global Online"},{"issue":"6","key":"6104_CR67","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.jhsg.2022.05.008","volume":"4","author":"KN McKnight","year":"2022","unstructured":"McKnight KN, Smith VJS, MacFadden LN, Chong ACM, Van Demark RE, Jr (2022) Wide-Awake Hand Surgery Has Its Benefits: A Study of 1,011 Patients. J Hand Surg Glob Online 4(6):394\u2013398. https:\/\/doi.org\/10.1016\/j.jhsg.2022.05.008","journal-title":"J Hand Surg Glob Online"},{"issue":"5","key":"6104_CR68","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.hansur.2022.06.005","volume":"41","author":"V Meunier","year":"2022","unstructured":"Meunier V, Mares O, Gricourt Y, Simon N, Kouyoumdjian P, Cuvillon P (2022) Patient satisfaction after distal upper limb surgery under WALANT versus axillary block: a propensity-matched comparative cohort study. Hand Surg Rehabilitation 41(5):576\u2013581. https:\/\/doi.org\/10.1016\/j.hansur.2022.06.005","journal-title":"Hand Surg Rehabilitation"},{"issue":"1","key":"6104_CR69","doi-asserted-by":"publisher","first-page":"230949901983300","DOI":"10.1177\/2309499019833002","volume":"27","author":"MZ Mohd Rashid","year":"2019","unstructured":"Mohd Rashid MZ, Sapuan J, Abdullah S (2019) A randomized controlled trial of trigger finger release under digital anesthesia with (WALANT) and without adrenaline. J Orthop Surg (Hong Kong) 27(1):2309499019833002. https:\/\/doi.org\/10.1177\/2309499019833002","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"3","key":"6104_CR70","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1007\/s00402-020-03744-5","volume":"141","author":"P Moog","year":"2021","unstructured":"Moog P, Dozan M, Betzl J, Sukhova I, K\u00fckrek H, Megerle K (2021) WALANT-epinephrine injection may lead to short term, reversible episodes of critical oxygen saturation in the fingertips. Arch Orthop Trauma Surg 141(3):527\u2013533. https:\/\/doi.org\/10.1007\/s00402-020-03744-5","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"6104_CR71","doi-asserted-by":"publisher","first-page":"141","DOI":"10.17159\/2309-8309\/2021\/v20n3a1","volume":"20","author":"JJ Naude","year":"2021","unstructured":"Naude JJ, Koch O, Schmidt LW, le Roux TLB (2021) Positive patient experience of Wide Awake Local Anaesthesia No Tourniquet (WALANT) hand surgery in the government setting: a prospective descriptive study. SA Orthopaedic J 20(3):141\u2013146. https:\/\/doi.org\/10.17159\/2309-8309\/2021\/v20n3a1","journal-title":"SA Orthopaedic J"},{"issue":"2","key":"6104_CR72","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s11552-009-9239-y","volume":"5","author":"R Nelson","year":"2010","unstructured":"Nelson R, Higgins A, Conrad J, Bell M, Lalonde D (2010) The wide-awake approach to Dupuytren\u2019s disease: fasciectomy under local anesthetic with epinephrine. Hand (New York N.Y) 5(2):117\u2013124. https:\/\/doi.org\/10.1007\/s11552-009-9239-y","journal-title":"Hand (New York N.Y)"},{"key":"6104_CR73","doi-asserted-by":"publisher","unstructured":"Noureddine H, Vejsbjerg K, Harrop JE, White MJ, Chakravarthy J, Harrison JWK (2020) Fasciectomy under local anaesthetic and adrenaline for Dupuytren's contracture in a community setting in the UK with a cost analysis. Bone Joint J 102-B(10), 1354-1358. https:\/\/doi.org\/10.1302\/0301-620X.102B10.BJJ-2019-1685.R2","DOI":"10.1302\/0301-620X.102B10.BJJ-2019-1685.R2"},{"issue":"10","key":"6104_CR74","doi-asserted-by":"publisher","first-page":"4269","DOI":"10.1177\/0300060518793036","volume":"46","author":"H Orbach","year":"2018","unstructured":"Orbach H, Rozen N, Rubin G (2018) Open reduction and internal fixation of intra-articular distal radius fractures under wide-awake local anesthesia with no tourniquet. J Int Med Res 46(10):4269\u20134276. https:\/\/doi.org\/10.1177\/0300060518793036","journal-title":"J Int Med Res"},{"issue":"2","key":"6104_CR75","doi-asserted-by":"publisher","first-page":"119","DOI":"10.14744\/SEMB.2017.17363","volume":"52","author":"\u0130A \u00d6zt\u00fcrk","year":"2018","unstructured":"\u00d6zt\u00fcrk \u0130A, \u00d6zt\u00fcrk K, Orman O, Baydar M, Aykut S, K\u00f6se A (2018) Comparison of the cost and efficacy of axillary anesthesia and wide-awake anesthesia in finger surgeries. Sisli Etfal Hastanesi tip bulteni 52(2):119\u2013123. https:\/\/doi.org\/10.14744\/SEMB.2017.17363","journal-title":"Sisli Etfal Hastanesi tip bulteni"},{"issue":"10","key":"6104_CR76","doi-asserted-by":"publisher","first-page":"3587","DOI":"10.37358\/RC.19.10.7602","volume":"70","author":"M Pertea","year":"2019","unstructured":"Pertea M, Grosu OM, Veliceasa B, Velenciuc N, Ciobanu P, Tudor R, Poroch V, Lunca S (2019) Effectiveness and safety of wide awake local anesthesia no tourniquet (WALANT) technique in hand surgery. Revista de Chimie 70(10):3587\u20133591. https:\/\/doi.org\/10.37358\/RC.19.10.7602","journal-title":"Revista de Chimie"},{"issue":"1","key":"6104_CR77","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1055\/s-0037-1618911","volume":"10","author":"A Poggetti","year":"2018","unstructured":"Poggetti A, Nucci AM, Giesen T, Calcagni M, Marchetti S, Lisanti M (2018) Percutaneous intramedullary headless screw fixation and wide-awake anesthesia to treat metacarpal fractures: early results in 25 patients. J Hand Microsurg 10(1):16\u201321. https:\/\/doi.org\/10.1055\/s-0037-1618911","journal-title":"J Hand Microsurg"},{"issue":"4","key":"6104_CR78","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1055\/s-0042-1742456","volume":"15","author":"C Pr\u00e9naud","year":"2022","unstructured":"Pr\u00e9naud C, Merlini L, Hurst SA, Gregory T, Dacheux C (2022) A study of hand flap viability when using a wide awake local anesthesia no tourniquet (WALANT) technique. J Hand Microsurg 15(4):270\u2013274. https:\/\/doi.org\/10.1055\/s-0042-1742456","journal-title":"J Hand Microsurg"},{"issue":"2","key":"6104_CR79","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1177\/1558944721994262","volume":"18","author":"I Rell\u00e1n","year":"2023","unstructured":"Rell\u00e1n I, Bronenberg Victorica P, Kohan Fortuna Figueira SV, Donndorff AG, De Carli P, Boretto JG (2023) What is the infection rate of carpal tunnel syndrome and trigger finger release performed under wide-awake anesthesia? Hand (N Y) 18(2):198\u2013202. https:\/\/doi.org\/10.1177\/1558944721994262","journal-title":"Hand (N Y)"},{"issue":"5","key":"6104_CR80","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1177\/1558944720975132","volume":"17","author":"M Reynolds","year":"2022","unstructured":"Reynolds M, Srinivasan RC, Person DW (2022) Complications after clinic-based wide awake local anesthesia no tourniquet hand surgery at a single private practice. Hand (New York N.Y) 17(5):865\u2013868. https:\/\/doi.org\/10.1177\/1558944720975132","journal-title":"Hand (New York N.Y)"},{"issue":"3","key":"6104_CR81","doi-asserted-by":"publisher","first-page":"e139","DOI":"10.1016\/j.jhsa.2016.11.019","volume":"42","author":"PC Rhee","year":"2017","unstructured":"Rhee PC, Fischer MM, Rhee LS, McMillan H, Johnson AE (2017) Cost savings and patient experiences of a clinic-based, wide-awake hand surgery program at a military medical center: a critical analysis of the first 100 procedures. The J Hand Surg 42(3):e139\u2013e147. https:\/\/doi.org\/10.1016\/j.jhsa.2016.11.019","journal-title":"The J Hand Surg"},{"issue":"1","key":"6104_CR82","first-page":"106","volume":"98","author":"S Ruxasagulwong","year":"2015","unstructured":"Ruxasagulwong S, Kraisarin J, Sananpanich K (2015) Wide awake technique versus local anesthesia with tourniquet application for minor orthopedic hand surgery: a prospective clinical trial. J Med Ass Thailand Chotmaihet Thangphaet 98(1):106\u2013110","journal-title":"J Med Ass Thailand Chotmaihet Thangphaet"},{"issue":"4","key":"6104_CR83","doi-asserted-by":"publisher","first-page":"e3513","DOI":"10.1097\/GOX.0000000000003513","volume":"9","author":"E Saleh","year":"2021","unstructured":"Saleh E, Saleh J, Govshievich A, Ferland-Caron G, Lin JC, Tremblay DM (2021) Comparing minor hand procedures performed with or without the use of a tourniquet: a randomized controlled trial. Plast Reconstr Surg Glob Open 9(4):e3513. https:\/\/doi.org\/10.1097\/GOX.0000000000003513","journal-title":"Plast Reconstr Surg Glob Open"},{"issue":"1","key":"6104_CR84","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1177\/1558944718787853","volume":"15","author":"SE Sasor","year":"2020","unstructured":"Sasor SE, Cook JA, Duquette SP, Lucich EA, Cohen AC, Wooden WA, Tholpady SS, Chu MW (2020) Tourniquet use in wide-awake carpal tunnel release. Hand (New York N.Y) 15(1):59\u201363. https:\/\/doi.org\/10.1177\/1558944718787853","journal-title":"Hand (New York N.Y)"},{"issue":"6","key":"6104_CR85","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/j.jhsg.2021.12.006","volume":"4","author":"L Schindelar","year":"2022","unstructured":"Schindelar L, Townsend CB, Ilyas AM, Matzon JL (2022) The impact of intraoperative nursing care on perioperative complications during wide-awake local anesthesia hand surgery. J Hand Surg Global Online 4(6):385\u2013388. https:\/\/doi.org\/10.1016\/j.jhsg.2021.12.006","journal-title":"J Hand Surg Global Online"},{"issue":"4","key":"6104_CR86","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1177\/15589447211063545","volume":"18","author":"S Sharma","year":"2023","unstructured":"Sharma S, Ong J, Putti A (2023) Proximal interphalangeal joint arthroplasty using the wide-awake local anesthesia no tourniquet technique. Hand (New York, N.Y) 18(4):612\u2013615. https:\/\/doi.org\/10.1177\/15589447211063545","journal-title":"Hand (New York, N.Y)"},{"issue":"5","key":"6104_CR87","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1177\/1558944719890038","volume":"16","author":"S Sraj","year":"2021","unstructured":"Sraj S (2021) Carpal tunnel release with wide awake local anesthesia and no tourniquet: with versus without epinephrine. Hand (New York NY) 16(5):592\u2013594. https:\/\/doi.org\/10.1177\/1558944719890038","journal-title":"Hand (New York NY)"},{"issue":"4","key":"6104_CR88","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1097\/PRS.0000000000009542","volume":"150","author":"AK Steve","year":"2022","unstructured":"Steve AK, Shine JJ, Yakaback S, Matthews JL, Yeung J (2022) Low infection rate for hand fractures managed with surgical fixation under wide-awake local anesthesia with no tourniquet in minor surgery. Plast Reconstr Surg 150(4):829\u2013833. https:\/\/doi.org\/10.1097\/PRS.0000000000009542","journal-title":"Plast Reconstr Surg"},{"key":"6104_CR89","unstructured":"Tahir M, Mehboob G, R Jamali A, Phillips AM (2020) Use of the wide-awake local anaesthetic no tourniquet in the management of distal radius fractures. J Pak Med Assoc 70(Suppl 1) (2):S42\u2013S48"},{"issue":"9","key":"6104_CR90","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1177\/1753193412475241","volume":"38","author":"I Teo","year":"2013","unstructured":"Teo I, Lam W, Muthayya P, Steele K, Alexander S, Miller G (2013) Patients\u2019 perspective of wide-awake hand surgery\u2014100 consecutive cases. The J Hand Surg Europ 38(9):992\u2013999. https:\/\/doi.org\/10.1177\/1753193412475241","journal-title":"The J Hand Surg Europ"},{"issue":"4","key":"6104_CR91","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1177\/15589447211064364","volume":"18","author":"CB Townsend","year":"2023","unstructured":"Townsend CB, Henry TW, Matzon JL, Seigerman D, Sodha SC, Beredjiklian PK (2023) Functional outcomes of flexor tendon repair in the fingers: a comparison of wide-awake local anesthesia no tourniquet versus traditional anesthesia. Hand (New York, N.Y) 18(4):635\u2013640. https:\/\/doi.org\/10.1177\/15589447211064364","journal-title":"Hand (New York, N.Y)"},{"issue":"2","key":"6104_CR92","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1177\/15589447211003180","volume":"18","author":"I Wellington","year":"2023","unstructured":"Wellington I, Cusano A, Ferreira JV, Parrino A (2023) WALANT technique versus sedation for endoscopic carpal tunnel release. Hand (New York N.Y) 18(2):214\u2013221. https:\/\/doi.org\/10.1177\/15589447211003180","journal-title":"Hand (New York N.Y)"},{"issue":"2","key":"6104_CR93","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1097\/00006534-200102000-00014","volume":"107","author":"BJ Wilhelmi","year":"2001","unstructured":"Wilhelmi BJ, Blackwell SJ, Miller JH, Mancoll JS, Dardano T, Tran A, Phillips LG (2001) Do not use epinephrine in digital blocks: myth or truth? Plast Reconstr Surg 107(2):393\u2013397. https:\/\/doi.org\/10.1097\/00006534-200102000-00014","journal-title":"Plast Reconstr Surg"},{"issue":"6","key":"6104_CR94","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1177\/1753193417703516","volume":"42","author":"J Wong","year":"2017","unstructured":"Wong J, Lin CH, Chang NJ, Chen HC, Lin YT, Hsu CC (2017) Digital revascularization and replantation using the wide-awake hand surgery technique. The J Hand Surg Europ 42(6):621\u2013625. https:\/\/doi.org\/10.1177\/1753193417703516","journal-title":"The J Hand Surg Europ"},{"issue":"1","key":"6104_CR95","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.hcl.2018.08.009","volume":"35","author":"SG Xing","year":"2019","unstructured":"Xing SG, Tang JB (2019) Extending applications of local anesthesia without tourniquet to flap harvest and transfer in the hand. Hand Clin 35(1):97\u2013102. https:\/\/doi.org\/10.1016\/j.hcl.2018.08.009","journal-title":"Hand Clin"},{"issue":"1","key":"6104_CR96","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1186\/s12891-020-03482-0","volume":"21","author":"CY Yen","year":"2020","unstructured":"Yen CY, Ma CH, Wu CH, Yang SC, Jou IM, Tu YK (2020) A cost and efficacy analysis of performing arthroscopic excision of wrist ganglions under wide-awake anaesthesia versus general anaesthesia. BMC Musculoskelet Disord 21(1):459. https:\/\/doi.org\/10.1186\/s12891-020-03482-0","journal-title":"BMC Musculoskelet Disord"},{"issue":"6","key":"6104_CR97","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1016\/j.jhsg.2020.09.003","volume":"2","author":"LM Yi","year":"2020","unstructured":"Yi LM, Ahmad AA, Ruslan SR, Abdullah S, Ahmad AR (2020) Plating distal radius fractures using wide-awake local anesthesia no tourniquet (WALANT) versus general anesthesia: a cohort study. J Hand Surg Global Online 2(6):331\u2013338. https:\/\/doi.org\/10.1016\/j.jhsg.2020.09.003","journal-title":"J Hand Surg Global Online"},{"issue":"9","key":"6104_CR98","doi-asserted-by":"publisher","first-page":"1852","DOI":"10.1016\/j.jhsa.2015.06.103","volume":"40","author":"AB Lipira","year":"2015","unstructured":"Lipira AB, Sood RF, Tatman PD, Davis JI, Morrison SD, Ko JH (2015) Complications within 30 days of hand surgery: an analysis of 10,646 patients. The J Hand Surg 40(9):1852\u201359.e3. https:\/\/doi.org\/10.1016\/j.jhsa.2015.06.103","journal-title":"The J Hand Surg"},{"issue":"1","key":"6104_CR99","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1055\/s-0040-1709212","volume":"14","author":"N Goyal","year":"2020","unstructured":"Goyal N, Bohl DD, Wysocki RW (2020) Timing of complications following hand surgery. J Hand Microsurg 14(1):31\u201338. https:\/\/doi.org\/10.1055\/s-0040-1709212","journal-title":"J Hand Microsurg"},{"issue":"7","key":"6104_CR100","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1016\/j.joms.2016.12.045","volume":"75","author":"VT Warren","year":"2017","unstructured":"Warren VT, Fisher AG, Rivera EM, Saha PT, Turner B, Reside G, Phillips C, White RP Jr (2017) Buffered 1% lidocaine with epinephrine is as effective as non-buffered 2% lidocaine with epinephrine for mandibular nerve block. J Oral Maxillofacial Surg 75(7):1363\u20131366. https:\/\/doi.org\/10.1016\/j.joms.2016.12.045","journal-title":"J Oral Maxillofacial Surg"},{"issue":"2","key":"6104_CR101","first-page":"88","volume":"43","author":"SD Baker","year":"2021","unstructured":"Baker SD, Lee JY, White RP, Collins L, Bodnar W, Philips C, Divaris K (2021) Double-blind, randomized clinical trial comparing one percent buffered versus two percent unbuffered lidocaine injections in children. Pediatr Dent 43(2):88\u201394","journal-title":"Pediatr Dent"},{"issue":"5","key":"6104_CR102","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1016\/j.jhsa.2013.02.016","volume":"38","author":"HJ Lee","year":"2013","unstructured":"Lee HJ, Cho YJ, Gong HS, Rhee SH, Park HS, Baek GH (2013) The effect of buffered lidocaine in local anesthesia: a prospective, randomized, double-blind study. The J Hand Surg 38(5):971\u2013975. https:\/\/doi.org\/10.1016\/j.jhsa.2013.02.016","journal-title":"The J Hand Surg"},{"issue":"2","key":"6104_CR103","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1111\/wrr.12125","volume":"22","author":"SL Percival","year":"2014","unstructured":"Percival SL, McCarty S, Hunt JA, Woods EJ (2014) The effects of pH on wound healing, biofilms, and antimicrobial efficacy. Wound Repair Regen 22(2):174\u201386. https:\/\/doi.org\/10.1111\/wrr.12125","journal-title":"Wound Repair Regen"},{"issue":"1","key":"6104_CR104","doi-asserted-by":"publisher","first-page":"e49","DOI":"10.1016\/S2665-9913(20)30238-1","volume":"3","author":"JCE Lane","year":"2020","unstructured":"Lane JCE, Craig RS, Rees JL, Gardiner MD, Green J, Prieto-Alhambra D, Furniss D (2020) Serious postoperative complications and reoperation after carpal tunnel decompression surgery in England: a nationwide cohort analysis. The Lancet Rheumatol 3(1):e49\u2013e57. https:\/\/doi.org\/10.1016\/S2665-9913(20)30238-1","journal-title":"The Lancet Rheumatol"},{"issue":"8","key":"6104_CR105","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1016\/j.jhsa.2012.05.014","volume":"37","author":"H Bruijnzeel","year":"2012","unstructured":"Bruijnzeel H, Neuhaus V, Fostvedt S, Jupiter JB, Mudgal CS, Ring DC (2012) Adverse events of open A1 pulley release for idiopathic trigger finger. The J Hand Surg 37(8):1650\u20131656. https:\/\/doi.org\/10.1016\/j.jhsa.2012.05.014","journal-title":"The J Hand Surg"},{"issue":"5","key":"6104_CR106","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s00402-011-1440-0","volume":"132","author":"F Cakmak","year":"2012","unstructured":"Cakmak F, Wolf MB, Bruckner T, Hahn P, Unglaub F (2012) Follow-up investigation of open trigger digit release. Arch Orthop Trauma Surg 132(5):685\u2013691. https:\/\/doi.org\/10.1007\/s00402-011-1440-0","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"6104_CR107","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1142\/s0218810403001820","volume":"8","author":"V Finsen","year":"2003","unstructured":"Finsen V, Hagen S (2003) Surgery for trigger finger. Hand surgery\u202f: an international journal devoted to hand and upper limb surgery and related research\u202f: journal of the Asia-Pacific Federation of Societies for Surgery of the Hand 8(2):201\u2013203. https:\/\/doi.org\/10.1142\/s0218810403001820","journal-title":"Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand"},{"issue":"12","key":"6104_CR108","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1007\/s00402-008-0802-8","volume":"129","author":"D Lange-Riess","year":"2009","unstructured":"Lange-Riess D, Schuh R, H\u00f6nle W, Schuh A (2009) Long-term results of surgical release of trigger finger and trigger thumb in adults. Arch Orthop Trauma Surg 129(12):1617\u20131619. https:\/\/doi.org\/10.1007\/s00402-008-0802-8","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"6104_CR109","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1016\/J.JHSB.2007.02.016","volume":"32","author":"MH Lim","year":"2007","unstructured":"Lim MH, Lim KK, Rasheed MZ, Narayanan S, Beng-Hoi Tan A (2007) Outcome of open trigger digit release. The J Hand Surg Europ 32(4):457\u2013459. https:\/\/doi.org\/10.1016\/J.JHSB.2007.02.016","journal-title":"The J Hand Surg Europ"},{"issue":"2","key":"6104_CR110","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/s11552-014-9716-9","volume":"10","author":"NG Everding","year":"2015","unstructured":"Everding NG, Bishop GB, Belyea CM, Soong MC (2015) Risk factors for complications of open trigger finger release. Hand (New York N.Y) 10(2):297\u2013300. https:\/\/doi.org\/10.1007\/s11552-014-9716-9","journal-title":"Hand (New York N.Y)"},{"issue":"9","key":"6104_CR111","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1016\/j.jhsa.2022.04.017","volume":"47","author":"JE Koopman","year":"2022","unstructured":"Koopman JE, Zweedijk BE, Hundepool CA, Duraku LS, Smit J, Wouters RM, Selles RW, Hand-Wrist Study Group, Zuidam, J. M (2022) Prevalence and risk factors for postoperative complications following open A1 pulley release for a trigger finger or thumb. The J Hand Surg 47(9):823\u201383. https:\/\/doi.org\/10.1016\/j.jhsa.2022.04.017","journal-title":"The J Hand Surg"},{"issue":"3","key":"6104_CR112","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.jhsg.2022.01.008","volume":"4","author":"M Kardestuncer","year":"2022","unstructured":"Kardestuncer M, Kardestuncer T (2022) Office-based open trigger finger release has a low complication rate. J Hand Surg Global Online 4(3):153\u2013155. https:\/\/doi.org\/10.1016\/j.jhsg.2022.01.008","journal-title":"J Hand Surg Global Online"},{"issue":"3","key":"6104_CR113","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/j.jhsa.2011.11.006","volume":"37","author":"CJ Dy","year":"2012","unstructured":"Dy CJ, Hernandez-Soria A, Ma Y, Roberts TR, Daluiski A (2012) Complications after flexor tendon repair: a systematic review and meta-analysis. The J Hand Surg 37(3):543-551.e1. https:\/\/doi.org\/10.1016\/j.jhsa.2011.11.006","journal-title":"The J Hand Surg"},{"issue":"4","key":"6104_CR114","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/SAP.0000000000002196","volume":"84","author":"KA Holoyda","year":"2020","unstructured":"Holoyda KA, Farhat B, Lalonde DH, Owusu-Danso O, Agbenorku P, Hoyte-Williams PE, Rockwell WB (2020) Creating an outpatient, local anesthetic hand operating room in a resource-constrained Ghanaian hospital builds surgical capacity and financial stability. Ann Plast Surg 84(4):385\u2013389. https:\/\/doi.org\/10.1097\/SAP.0000000000002196","journal-title":"Ann Plast Surg"},{"issue":"7","key":"6104_CR115","doi-asserted-by":"publisher","first-page":"e797","DOI":"10.1097\/GOX.0000000000000756","volume":"4","author":"D Lalonde","year":"2016","unstructured":"Lalonde D, Higgins A (2016) Wide awake flexor tendon repair in the finger. Plast Reconstr Surg Glob Open 4(7):e797. https:\/\/doi.org\/10.1097\/GOX.0000000000000756","journal-title":"Plast Reconstr Surg Glob Open"},{"issue":"2","key":"6104_CR116","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.hcl.2013.02.009","volume":"29","author":"DH Lalonde","year":"2013","unstructured":"Lalonde DH, Martin AL (2013) Wide-awake flexor tendon repair and early tendon mobilization in zones 1 and 2. Hand Clin 29(2):207\u2013213. https:\/\/doi.org\/10.1016\/j.hcl.2013.02.009","journal-title":"Hand Clin"},{"issue":"6","key":"6104_CR117","doi-asserted-by":"publisher","first-page":"1045e","DOI":"10.1097\/PRS.0000000000002769","volume":"138","author":"WS Khor","year":"2016","unstructured":"Khor WS, Langer MF, Wong R, Zhou R, Peck F, Wong JKF (2016) Improving outcomes in tendon repair: a critical look at the evidence for flexor tendon repair and rehabilitation. Plast Reconstr Surg 138(6):1045e\u20131058e. https:\/\/doi.org\/10.1097\/PRS.0000000000002769","journal-title":"Plast Reconstr Surg"},{"issue":"3","key":"6104_CR118","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/j.arth.2013.07.022","volume":"29","author":"LA Holzer","year":"2014","unstructured":"Holzer LA, Holzer G (2014) The 50 highest cited papers in hip and knee arthroplasty. J Arthroplasty 29(3):453\u2013457. https:\/\/doi.org\/10.1016\/j.arth.2013.07.022","journal-title":"J Arthroplasty"},{"issue":"5","key":"6104_CR119","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1007\/s11999-010-1604-1","volume":"469","author":"KA Lefaivre","year":"2011","unstructured":"Lefaivre KA, Shadgan B, O\u2019Brien PJ (2011) 100 most cited articles in orthopaedic surgery. Clin Orthop Relat Res 469(5):1487\u20131497. https:\/\/doi.org\/10.1007\/s11999-010-1604-1","journal-title":"Clin Orthop Relat Res"},{"issue":"10","key":"6104_CR120","doi-asserted-by":"publisher","first-page":"2000","DOI":"10.3390\/healthcare10102000","volume":"10","author":"M Mercurio","year":"2022","unstructured":"Mercurio M, Cofano E, Familiari F, Corona K, Cerciello S, Gasparini G, Galasso O (2022) The 50 highest cited papers on shoulder arthroplasty. Healthcare (Basel, Switzerland) 10(10):2000. https:\/\/doi.org\/10.3390\/healthcare10102000","journal-title":"Healthcare (Basel, Switzerland)"},{"issue":"1","key":"6104_CR121","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1186\/s12874-021-01404-9","volume":"21","author":"M Raynaud","year":"2021","unstructured":"Raynaud M, Goutaudier V, Louis K, Al-Awadhi S, Dubourg Q, Truchot A, Brousse R, Saleh N, Giarraputo A, Debiais C, Demir Z, Certain A, Tacafred F, Cortes-Garcia E, Yanes S, Dagobert J, Naser S, Robin B, Bailly \u00c9, Jouven X, Reese PP, Loupy A (2021) Impact of the COVID-19 pandemic on publication dynamics and non-COVID-19 research production. BMC Med Res Methodol 21(1):255. https:\/\/doi.org\/10.1186\/s12874-021-01404-9","journal-title":"BMC Med Res Methodol"},{"issue":"4","key":"6104_CR122","doi-asserted-by":"publisher","first-page":"e38331","DOI":"10.7759\/cureus.38331","volume":"15","author":"S Gasson","year":"2023","unstructured":"Gasson S, Solari F, Jesudason EP (2023) Sustainable hand surgery: incorporating water efficiency into clinical practice. Cureus 15(4):e38331. https:\/\/doi.org\/10.7759\/cureus.38331","journal-title":"Cureus"},{"issue":"9","key":"6104_CR123","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1177\/17531934221118658","volume":"47","author":"P Witt","year":"2022","unstructured":"Witt P, Ayhan E, Hagert E, Naqui Z (2022) The global FESSH green survey: sustainability in hand surgery. The J Hand Surg Europ 47(9):983\u2013986. https:\/\/doi.org\/10.1177\/17531934221118658","journal-title":"The J Hand Surg Europ"},{"issue":"7","key":"6104_CR124","doi-asserted-by":"publisher","first-page":"e16269","DOI":"10.7759\/cureus.16269","volume":"13","author":"S Abdullah","year":"2021","unstructured":"Abdullah S, Chia Hua L, Sheau Yun L, Thavamany Devapitchai AS, Ahmad AA, Narin Singh PSG, Sapuan J (2021) A review of 1073 cases of wide-awake-local-anaesthesia-no-tourniquet (WALANT) in finger and hand surgeries in an urban hospital in Malaysia. Cureus 13(7):e16269. https:\/\/doi.org\/10.7759\/cureus.16269","journal-title":"Cureus"},{"key":"6104_CR125","doi-asserted-by":"publisher","first-page":"848422","DOI":"10.3389\/fsurg.2022.848422","volume":"9","author":"MY Bajuri","year":"2022","unstructured":"Bajuri MY, Saidfudin NS, Mazli N, Azriq NA, Azemi AF (2022) Safety of wide-awake local anesthesia with no tourniquet (WALANT) in for lower limb surgery: a potential alternative in times of emergency. Frontiers Surg 9:848422. https:\/\/doi.org\/10.3389\/fsurg.2022.848422","journal-title":"Frontiers Surg"},{"issue":"1","key":"6104_CR126","doi-asserted-by":"publisher","first-page":"e4756","DOI":"10.1097\/GOX.0000000000004756","volume":"11","author":"KM Connors","year":"2023","unstructured":"Connors KM, Kurtzman JS, Koehler SM (2023) Successful use of WALANT in local and regional soft tissue flaps: a case series. Plast Reconstr Surg Glob Open 11(1):e4756. https:\/\/doi.org\/10.1097\/GOX.0000000000004756","journal-title":"Plast Reconstr Surg Glob Open"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-024-06104-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-024-06104-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-024-06104-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,23]],"date-time":"2024-04-23T14:07:40Z","timestamp":1713881260000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-024-06104-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,17]]},"references-count":126,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["6104"],"URL":"https:\/\/doi.org\/10.1007\/s00264-024-06104-9","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,17]]},"assertion":[{"value":"6 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study is considered secondary research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This study is considered secondary research.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"This study is considered secondary research.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}