{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T19:11:46Z","timestamp":1790795506129,"version":"4.1.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2024,4,13]],"date-time":"2024-04-13T00:00:00Z","timestamp":1712966400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,4,13]],"date-time":"2024-04-13T00:00:00Z","timestamp":1712966400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"the Chinese Academy of Medical Sciences Innovation Fund for Medical Sciences","award":["2021-I2M-5-007"],"award-info":[{"award-number":["2021-I2M-5-007"]}]},{"name":"the Beijing JST Research Funding","award":["2023OSR-GCZX202202"],"award-info":[{"award-number":["2023OSR-GCZX202202"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2024,7]]},"DOI":"10.1007\/s00264-024-06179-4","type":"journal-article","created":{"date-parts":[[2024,4,13]],"date-time":"2024-04-13T00:01:27Z","timestamp":1712966487000},"page":"1903-1914","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Accuracy and clinical characteristics of robot-assisted cervical spine surgery: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"48","author":[{"given":"Jiayuan","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingxing","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Da","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangfang","family":"Duan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xieyuan","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1067-600X","authenticated-orcid":false,"given":"Wei","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,13]]},"reference":[{"key":"6179_CR1","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.spinee.2020.09.007","volume":"21","author":"N Fatima","year":"2021","unstructured":"Fatima N, Massaad E, Hadzipasic M, Shankar GM, Shin JH (2021) Safety and accuracy of robot-assisted placement of pedicle screws compared to conventional free-hand technique: a systematic review and meta-analysis. Spine J 21:181\u2013192. https:\/\/doi.org\/10.1016\/j.spinee.2020.09.007","journal-title":"Spine J"},{"key":"6179_CR2","doi-asserted-by":"publisher","unstructured":"Cunningham BW, Brooks DM, McAfee PC (2021) Accuracy of robotic-assisted spinal surgery-comparison to TJR Robotics, da Vinci Robotics, and Optoelectronic Laboratory Robotics. Int J Spine Surg 15:S38-S55. https:\/\/doi.org\/10.14444\/8139","DOI":"10.14444\/8139"},{"key":"6179_CR3","unstructured":"Bell GR, Garfin SR, Fischgrund J, Eismont FJ, Bono CM (2017) Rothman-Simeone The Spine E-Book"},{"key":"6179_CR4","doi-asserted-by":"publisher","first-page":"472","DOI":"10.3171\/2011.6.SPINE10809","volume":"15","author":"Y Ishikawa","year":"2011","unstructured":"Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15:472\u2013478. https:\/\/doi.org\/10.3171\/2011.6.SPINE10809","journal-title":"J Neurosurg Spine"},{"key":"6179_CR5","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1007\/s10143-016-0757-0","volume":"40","author":"N Shimokawa","year":"2017","unstructured":"Shimokawa N, Takami T (2017) Surgical safety of cervical pedicle screw placement with computer navigation system. Neurosurg Rev 40:251\u2013258. https:\/\/doi.org\/10.1007\/s10143-016-0757-0","journal-title":"Neurosurg Rev"},{"key":"6179_CR6","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1177\/15563316211026652","volume":"17","author":"DR Lebl","year":"2021","unstructured":"Lebl DR, Avrumova F, Abjornson C, Cammisa FP (2021) Cervical Spine Navigation and Enabled Robotics: A New Frontier in Minimally Invasive Surgery. Hss J 17:333\u2013343. https:\/\/doi.org\/10.1177\/15563316211026652","journal-title":"Hss J"},{"key":"6179_CR7","doi-asserted-by":"publisher","first-page":"E221","DOI":"10.1097\/01.brs.0000210263.87578.65","volume":"31","author":"MI Yusof","year":"2006","unstructured":"Yusof MI, Ming LK, Abdullah MS, Yusof AH (2006) Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation. Spine (Phila Pa 1976) (31):E221-224. https:\/\/doi.org\/10.1097\/01.brs.0000210263.87578.65","journal-title":"Spine (Phila Pa 1976)"},{"key":"6179_CR8","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1007\/s00276-021-02707-8","volume":"43","author":"K Morita","year":"2021","unstructured":"Morita K, Ohashi H, Kawamura D, Tani S, Karagiozov K, Murayama Y (2021) Thoracic and lumbar spine pedicle morphology in Japanese patients. Surg Radiol Anat 43:833\u2013842. https:\/\/doi.org\/10.1007\/s00276-021-02707-8","journal-title":"Surg Radiol Anat"},{"key":"6179_CR9","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1097\/00006123-200011000-00029","volume":"47","author":"HC U\u011fur","year":"2000","unstructured":"U\u011fur HC, Attar A, Uz A, Tekdemir I, Egemen N, Ca\u011flar S, Gen\u00e7 Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47:1162\u20131168. https:\/\/doi.org\/10.1097\/00006123-200011000-00029. (discussion 1168-1169)","journal-title":"Neurosurgery"},{"key":"6179_CR10","doi-asserted-by":"publisher","first-page":"52","DOI":"10.3171\/2010.3.Spine09231","volume":"13","author":"A Tomasino","year":"2010","unstructured":"Tomasino A, Parikh K, Koller H, Zink W, Tsiouris AJ, Steinberger J, H\u00e4rtl R (2010) The vertebral artery and the cervical pedicle: morphometric analysis of a critical neighborhood. J Neurosurg Spine 13:52\u201360. https:\/\/doi.org\/10.3171\/2010.3.Spine09231","journal-title":"J Neurosurg Spine"},{"key":"6179_CR11","doi-asserted-by":"publisher","first-page":"B2","DOI":"10.1097\/BRS.0000000000001674","volume":"41","author":"W Tian","year":"2018","unstructured":"Tian W (2018) Robot-assisted posterior C1\u20132 transarticular screw fixation for atlantoaxial instability a case report. Spine 41:B2\u2013B5. https:\/\/doi.org\/10.1097\/BRS.0000000000001674","journal-title":"Spine"},{"key":"6179_CR12","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1097\/BRS.0000000000003258","volume":"45","author":"M Fan","year":"2020","unstructured":"Fan M, Liu Y, He D, Han X, Zhao J, Duan F, Liu B, Tian W (2020) Improved Accuracy of Cervical Spinal Surgery with Robot-Assisted Screw Insertion: A Prospective, Randomized, Controlled Study. Spine 45:285\u2013291. https:\/\/doi.org\/10.1097\/BRS.0000000000003258","journal-title":"Spine"},{"key":"6179_CR13","doi-asserted-by":"publisher","unstructured":"Mao JZ, Soliman MAR, Karamian BA, Khan A, Fritz AG, Avasthi N, DiMaria S, Levy BR, O'Connor TE, Schroeder G, Pollina J, Vaccaro AR, Mullin JP (2022) Anatomical and technical considerations of robot-assisted cervical pedicle screw placement: a cadaveric study. Global Spine J 21925682211068410. https:\/\/doi.org\/10.1177\/21925682211068410","DOI":"10.1177\/21925682211068410"},{"key":"6179_CR14","doi-asserted-by":"publisher","unstructured":"Bindels BJJ, Dronkers BEG, Smits MLJ, Verlaan JJ (2023) Accurate placement and revisions for cervical pedicle screws placed with or without navigation: a systematic review and meta-analysis. Global Spine J: 21925682231196456. https:\/\/doi.org\/10.1177\/21925682231196456","DOI":"10.1177\/21925682231196456"},{"key":"6179_CR15","doi-asserted-by":"publisher","first-page":"777","DOI":"10.7326\/m14-2385","volume":"162","author":"B Hutton","year":"2015","unstructured":"Hutton B, Salanti G, Caldwell DM, Chaimani A, Schmid CH, Cameron C, Ioannidis JP, Straus S, Thorlund K, Jansen JP, Mulrow C, Catal\u00e1-L\u00f3pez F, G\u00f8tzsche PC, Dickersin K, Boutron I, Altman DG, Moher D (2015) The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations. Ann Intern Med 162:777\u2013784. https:\/\/doi.org\/10.7326\/m14-2385","journal-title":"Ann Intern Med"},{"key":"6179_CR16","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11\u201314. https:\/\/doi.org\/10.1097\/00007632-199001000-00004","journal-title":"Spine"},{"key":"6179_CR17","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1097\/brs.0000000000003258","volume":"45","author":"M Fan","year":"2020","unstructured":"Fan M, Liu Y, He D, Han X, Zhao J, Duan F, Liu B (2020) Tian W (2020) Improved accuracy of cervical spinal surgery with robot-assisted screw insertion: a prospective, randomized, controlled study. Spine Phila Pa 1976) 45:285\u2013291. https:\/\/doi.org\/10.1097\/brs.0000000000003258","journal-title":"Spine Phila Pa 1976)"},{"key":"6179_CR18","doi-asserted-by":"publisher","first-page":"d5928","DOI":"10.1136\/bmj.d5928","volume":"343","author":"JP Higgins","year":"2011","unstructured":"Higgins JP, Altman DG, G\u00f8tzsche PC, J\u00fcni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA (2011) The Cochrane Collaboration\u2019s tool for assessing risk of bias in randomised trials. BMJ 343:d5928. https:\/\/doi.org\/10.1136\/bmj.d5928","journal-title":"BMJ"},{"key":"6179_CR19","unstructured":"Hartling L, Hamm M, Milne A, Vandermeer B, Santaguida PL, Ansari M, Tsertsvadze A, Hempel S, Shekelle P, Dryden DM (2012) AHRQ Methods for Effective Health Care In: Validity and Inter-Rater Reliability Testing of Quality Assessment Instruments Agency for Healthcare Research and Quality (US), Rockville (MD)"},{"key":"6179_CR20","doi-asserted-by":"publisher","first-page":"66","DOI":"10.3171\/2022.7.SPINE22473","volume":"38","author":"RS Beyer","year":"2023","unstructured":"Beyer RS, Nguyen A, Brown NJ, Gendreau JL, Hatter MJ, Pooladzandi O, Pham MH (2023) Spinal robotics in cervical spine surgery: a systematic review with key concepts and technical considerations. J Neurosurg Spine 38:66\u201374. https:\/\/doi.org\/10.3171\/2022.7.SPINE22473","journal-title":"J Neurosurg Spine"},{"key":"6179_CR21","doi-asserted-by":"publisher","first-page":"329","DOI":"10.14245\/ns.2244952.476","volume":"20","author":"LP Zhou","year":"2023","unstructured":"Zhou LP, Zhang ZG, Li D, Fang S, Sheng R, Zhang RJ, Shen CL (2023) Robotics in Cervical Spine Surgery: Feasibility and Safety of Posterior Screw Placement. Neurospine 20:329\u2013339. https:\/\/doi.org\/10.14245\/ns.2244952.476","journal-title":"Neurospine"},{"key":"6179_CR22","doi-asserted-by":"publisher","first-page":"131","DOI":"10.19548\/j.2096-269x.2020.03.002","volume":"5","author":"ZD Lv","year":"2020","unstructured":"Lv ZD, Chen Z, Han YC, Lao LF, Li Q, Zhang YH, Shen HX (2020) Accuracy and clinical effect of robot-assisted posterior cervical pedicle screw placement in treatment of cervical spondylosis. J Clin Orthop Res 5:131\u2013137. https:\/\/doi.org\/10.19548\/j.2096-269x.2020.03.002","journal-title":"J Clin Orthop Res"},{"issue":"3","key":"6179_CR23","first-page":"149","volume":"42","author":"QQ Li","year":"2022","unstructured":"Li QQ, Yu LP, Cai WH, Zhou W, Cao XJ, Ren YX, Yin GY (2022) Surgical safety of cervical pedicle screw placement with orthopaedic surgery robot system. Chinese J Orthop 42(3):149\u2013155","journal-title":"Chinese J Orthop"},{"key":"6179_CR24","first-page":"1941","volume":"30","author":"Y Liu","year":"2022","unstructured":"Liu Y, Zhao ZG, Wang X, Hu J, Xu YY, Ma ZX, Liu XL, Qiao Y, Zheng CK (2022) Robot-assisted pedicle screw fixation for cervical fracture and dislocation. Orthop J China 30:1941\u20131946","journal-title":"Orthop J China"},{"key":"6179_CR25","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1186\/s12893-022-01826-2","volume":"22","author":"Z Lang","year":"2022","unstructured":"Lang Z, Han X, Fan M, Liu Y, He D, Tian W (2022) Posterior atlantoaxial internal fixation using Harms technique assisted by 3D-based navigation robot for treatment of atlantoaxial instability. BMC Surg 22:378. https:\/\/doi.org\/10.1186\/s12893-022-01826-2","journal-title":"BMC Surg"},{"key":"6179_CR26","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1177\/2192568220960406","volume":"12","author":"XJ Su","year":"2022","unstructured":"Su XJ, Lv ZD, Chen Z, Wang K, Zhu C, Chen H, Han YC, Song QX, Lao LF, Zhang YH, Li Q, Shen HX (2022) Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical Surgery. Glob Spine J 12:620\u2013626. https:\/\/doi.org\/10.1177\/2192568220960406","journal-title":"Glob Spine J"},{"key":"6179_CR27","doi-asserted-by":"publisher","first-page":"8508113","DOI":"10.1155\/2022\/8508113","volume":"2022","author":"J Zhan","year":"2022","unstructured":"Zhan J, Xu W, Lin J, Luan J, Hou Y, Wang Y, Li Y, Chen B, Lin D, Chen S (2022) Accuracy and safety of robot-assisted versus fluoroscopy-guided posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial dislocation: a preliminary study. Biomed Res Int 2022:8508113. https:\/\/doi.org\/10.1155\/2022\/8508113","journal-title":"Biomed Res Int"},{"key":"6179_CR28","doi-asserted-by":"publisher","first-page":"15934","DOI":"10.1038\/s41598-023-43136-4","volume":"13","author":"S Li","year":"2023","unstructured":"Li S, Du J, Huang Y, Hao D, Zhao Z, Chang Z, Zhu J, Wang X, Duan Y, He B (2023) Comparison of the efficacies of TINAVI robot-assisted surgery and conventional open surgery for Levine-Edward type IIA (postreduction) hangman fractures. Sci Rep 13:15934. https:\/\/doi.org\/10.1038\/s41598-023-43136-4","journal-title":"Sci Rep"},{"key":"6179_CR29","doi-asserted-by":"publisher","unstructured":"Zhao JW, Liu YJ, Zhang Q, Fan MX, Han XG, He D, Liu B, Tian W (2023) Robot-assisted percutaneous pars-pedicle screw fixation for treating Hangman's fracture. J Orthop Surg Res 18. https:\/\/doi.org\/10.1186\/s13018-023-03765-x","DOI":"10.1186\/s13018-023-03765-x"},{"key":"6179_CR30","doi-asserted-by":"publisher","unstructured":"Zhou LP, Zhang RJ, Zhang WK, Kang L, Li KX, Zhang HQ, Jia CY, Zhang YS, Shen CL (2023) Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods. Neurosurg Rev 46. https:\/\/doi.org\/10.1007\/s10143-023-02027-y","DOI":"10.1007\/s10143-023-02027-y"},{"key":"6179_CR31","doi-asserted-by":"publisher","first-page":"e777","DOI":"10.1016\/j.wneu.2021.03.150","volume":"150","author":"K Farah","year":"2021","unstructured":"Farah K, Meyer M, Prost S, Albader F, Dufour H, Blondel B, Fuentes S (2021) Robotic Assistance for Minimally Invasive Cervical Pedicle Instrumentation: Report on Feasibility and Safety. World Neurosurg 150:e777\u2013e782. https:\/\/doi.org\/10.1016\/j.wneu.2021.03.150","journal-title":"World Neurosurg"},{"key":"6179_CR32","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1007\/s00586-022-07110-4","volume":"31","author":"S Kisinde","year":"2022","unstructured":"Kisinde S, Hu X, Hesselbacher S, Satin AM, Lieberman IH (2022) Robotic-guided placement of cervical pedicle screws: feasibility and accuracy. Eur Spine J 31:693\u2013701. https:\/\/doi.org\/10.1007\/s00586-022-07110-4","journal-title":"Eur Spine J"},{"key":"6179_CR33","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","volume":"23","author":"AV Matur","year":"2023","unstructured":"Matur AV, Palmisciano P, Duah HO, Chilakapati SS, Cheng JS, Adogwa O (2023) Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis. Spine J 23:197\u2013208. https:\/\/doi.org\/10.1016\/j.spinee.2022.10.006","journal-title":"Spine J"},{"key":"6179_CR34","doi-asserted-by":"publisher","first-page":"136","DOI":"10.21037\/jss.2019.11.13","volume":"6","author":"N Wallace","year":"2020","unstructured":"Wallace N, Schaffer NE, Freedman BA, Nassr A, Currier BL, Patel R, Aleem IS (2020) Computer-assisted navigation in complex cervical spine surgery: tips and tricks. J Spine Surg 6:136\u2013144. https:\/\/doi.org\/10.21037\/jss.2019.11.13","journal-title":"J Spine Surg"},{"key":"6179_CR35","doi-asserted-by":"publisher","first-page":"262","DOI":"10.21037\/jss.2020.03.07","volume":"6","author":"KA Tan","year":"2020","unstructured":"Tan KA, Lin S, Chin BZ, Thadani VN, Hey HWD (2020) Anatomic techniques for cervical pedicle screw placement. J Spine Surg 6:262\u2013273. https:\/\/doi.org\/10.21037\/jss.2020.03.07","journal-title":"J Spine Surg"},{"key":"6179_CR36","doi-asserted-by":"publisher","first-page":"839","DOI":"10.14245\/ns.2142560.180","volume":"18","author":"Q Zhang","year":"2021","unstructured":"Zhang Q, Fan M-X, Han X-G, Liu Y-J, He D, Liu B, Tian W (2021) Risk factors of unsatisfactory robot- assisted pedicle screw placement a case-control study. Neurospine 18:839\u2013844. https:\/\/doi.org\/10.14245\/ns.2142560.180","journal-title":"Neurospine"},{"key":"6179_CR37","doi-asserted-by":"publisher","first-page":"1549","DOI":"10.1016\/j.spinee.2013.06.006","volume":"13","author":"JM Lin","year":"2013","unstructured":"Lin JM, Hipp JA, Reitman CA (2013) C1 lateral mass screw placement via the posterior arch: a technique comparison and anatomic analysis. Spine J 13:1549\u20131555. https:\/\/doi.org\/10.1016\/j.spinee.2013.06.006","journal-title":"Spine J"},{"key":"6179_CR38","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1111\/os.12454","volume":"11","author":"W Tian","year":"2019","unstructured":"Tian W, Liu Y-J, Liu B, He D, Wu J-Y, Han X-G, Zhao J-W, Fan M-X, Engineering TCoMREoCSoB, Center TCCoNROSA (2019) Guideline for Posterior Atlantoaxial Internal Fixation Assisted by Orthopaedic Surgical Robot. Orthop Surg 11:160\u2013166. https:\/\/doi.org\/10.1111\/os.12454","journal-title":"Orthop Surg"},{"key":"6179_CR39","doi-asserted-by":"publisher","first-page":"2273","DOI":"10.1007\/s11548-016-1448-6","volume":"11","author":"H Liu","year":"2016","unstructured":"Liu H, Chen WK, Wang ZY, Lin J, Meng B, Yang HL (2016) Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis. Int J Comput Assist Radiol Surg 11:2273\u20132281. https:\/\/doi.org\/10.1007\/s11548-016-1448-6","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"6179_CR40","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1097\/BRS.0000000000004357","volume":"47","author":"DC Perfetti","year":"2022","unstructured":"Perfetti DC, Kisinde S, Rogers-LaVanne MP, Satin AM, Lieberman IH (2022) Robotic Spine Surgery: Past, Present, and Future. Spine 47:909\u2013921. https:\/\/doi.org\/10.1097\/BRS.0000000000004357","journal-title":"Spine"},{"key":"6179_CR41","doi-asserted-by":"publisher","first-page":"615","DOI":"10.3171\/2018.10.SPINE18487","volume":"30","author":"X Han","year":"2019","unstructured":"Han X, Tian W, Liu Y, Liu B, He D, Sun Y, Han X, Fan M, Zhao J, Xu Y, Zhang Q (2019) Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial. J Neurosurg-Spine 30:615\u2013622. https:\/\/doi.org\/10.3171\/2018.10.SPINE18487","journal-title":"J Neurosurg-Spine"},{"key":"6179_CR42","doi-asserted-by":"publisher","unstructured":"Naik A, Smith AD, Shaffer A, Krist DT, Moawad CM, MacInnis BR, Teal K, Hassaneen W, Arnold PM (2022) Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis. Neurosurg Focus 52. https:\/\/doi.org\/10.3171\/2021.10.FOCUS21509","DOI":"10.3171\/2021.10.FOCUS21509"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-024-06179-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-024-06179-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-024-06179-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,13]],"date-time":"2024-06-13T04:04:23Z","timestamp":1718251463000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-024-06179-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,13]]},"references-count":42,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2024,7]]}},"alternative-id":["6179"],"URL":"https:\/\/doi.org\/10.1007\/s00264-024-06179-4","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,13]]},"assertion":[{"value":"22 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}