{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T15:12:15Z","timestamp":1789571535364,"version":"build-2803163510"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2025,7,19]],"date-time":"2025-07-19T00:00:00Z","timestamp":1752883200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,19]],"date-time":"2025-07-19T00:00:00Z","timestamp":1752883200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University of Health Sciences"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>The Both Column Screw (BCS) fixation technique is a recently introduced, innovative method for the treatment of acetabular posterior column fractures. This study aims to biomechanically compare the BCS technique with conventional posterior column lag screw fixation methods using finite element analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Five different internal fixation models were simulated using five distinct screw fixation techniques: antegrade posterior column screw (APCS), retrograde posterior column screw (RPCS), magic screw (MS), anterior BCS (aBCS), and posterior BCS (pBCS). The modeling process included meshing, assignment of material properties, and definition of boundary conditions. Each model was subjected to three different loading conditions: level walking, stairs up, and stairs down. The biomechanical performance of each fixation technique was evaluated based on five parameters: maximum stress in the screw, maximum stress in the bone, total deformation, gap in fracture surfaces, and sliding distance in the fracture surface.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Finite element analysis demonstrated biomechanical differences among the five fixation techniques. The APCS model consistently showed the highest stress values and deformation across all loading conditions, whereas the MS, aBCS, and pBCS models exhibited lower deformation and stress parameters. Among these, pBCS generally displayed the most favorable performance in terms of stress reduction and fracture stability. Overall, the BCS configurations (aBCS and pBCS) showed improved biomechanical behavior compared to conventional fixation methods.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The BCS fixation technique, due to its superior biomechanical properties, may serve as a valuable addition to current methods for acetabular posterior column fractures. It broadens surgical options and may support clinical decision-making for orthopaedic surgeons.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s00264-025-06604-2","type":"journal-article","created":{"date-parts":[[2025,7,19]],"date-time":"2025-07-19T04:39:45Z","timestamp":1752899985000},"page":"2271-2280","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Is the innovative both column screw fixation technique a biomechanical game-changer in the fixation of acetabular posterior column fractures?"],"prefix":"10.1007","volume":"49","author":[{"given":"Vedat","family":"\u00d6zt\u00fcrk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Burak","family":"Kaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Talip","family":"\u00c7elik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malik","family":"\u00c7elik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cemal","family":"Kural","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustafa G\u00f6khan","family":"Bilgili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,19]]},"reference":[{"key":"6604_CR1","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1302\/0301-620X.92B2.22488","volume":"92","author":"TA Ferguson","year":"2010","unstructured":"Ferguson TA, Patel R, Bhandari M, Matta JM (2010) Fractures of the acetabulum in patients aged 60 years and older: an epidemiological and radiological study. J Bone Jt Surg - Ser B 92:250\u2013257. https:\/\/doi.org\/10.1302\/0301-620X.92B2.22488","journal-title":"J Bone Jt Surg - Ser B"},{"key":"6604_CR2","doi-asserted-by":"publisher","first-page":"2267","DOI":"10.1016\/J.INJURY.2020.06.016","volume":"51","author":"J Kelly","year":"2020","unstructured":"Kelly J, Ladurner A, Rickman M (2020) Surgical management of acetabular fractures - A contemporary literature review. Injury 51:2267\u20132277. https:\/\/doi.org\/10.1016\/J.INJURY.2020.06.016","journal-title":"Injury"},{"key":"6604_CR3","doi-asserted-by":"publisher","first-page":"E13","DOI":"10.1097\/BOT.0000000000001856","volume":"35","author":"YA Kati","year":"2021","unstructured":"Kati YA, Kose O, Acar B et al (2021) Risk of injury to the neurovascular structures in the pararectus approach used in acetabular fractures: A cadaver study. J Orthop Trauma 35:E13\u2013E17. https:\/\/doi.org\/10.1097\/BOT.0000000000001856","journal-title":"J Orthop Trauma"},{"key":"6604_CR4","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1016\/J.OTSR.2019.11.019","volume":"106","author":"E Melhem","year":"2020","unstructured":"Melhem E, Riouallon G, Habboubi K et al (2020) Epidemiology of pelvic and acetabular fractures in France. Orthop Traumatol Surg Res 106:831\u2013839. https:\/\/doi.org\/10.1016\/J.OTSR.2019.11.019","journal-title":"Orthop Traumatol Surg Res"},{"issue":"1","key":"6604_CR5","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1302\/0301-620X.87B1.15605","volume":"87","author":"PV Giannoudis","year":"2005","unstructured":"Giannoudis PV, Grotz MR, Papakostidis C, Dinopoulos H (2005) Operative treatment of displaced fractures of the acetabulum. A meta-analysis. J Bone Joint Surg Br Jan 87(1):2\u20139","journal-title":"J Bone Joint Surg Br Jan"},{"key":"6604_CR6","first-page":"119","volume":"81","author":"R Judet","year":"1968","unstructured":"Judet R, Judet J, Lanzetta A, Letournel E (1968) Fractures of the acetabulum. Classification and guiding rules for open reduction. Arch Ortop 81:119\u2013158","journal-title":"Arch Ortop"},{"issue":"3","key":"6604_CR7","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.3390\/JCM12031163","volume":"12","author":"S Einhorn","year":"2023","unstructured":"Einhorn S, H\u00f6ch A, Osterhoff G et al (2023) Comparison of percutaneous screw fixation to open reduction and internal fixation in acetabular fractures: A matched pair study regarding the Short-Term rate of conversion to total hip arthroplasty and functional outcomes. J Clin Med 12(3):1163. https:\/\/doi.org\/10.3390\/JCM12031163","journal-title":"J Clin Med"},{"key":"6604_CR8","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1302\/2058-5241.3.170054","volume":"3","author":"H Caviglia","year":"2018","unstructured":"Caviglia H, Mejai A, Landro ME, Vatani N (2018) Percutaneous fixation of acetabular fractures. EFORT Open Rev 3:326. https:\/\/doi.org\/10.1302\/2058-5241.3.170054","journal-title":"EFORT Open Rev"},{"issue":"6","key":"6604_CR9","doi-asserted-by":"publisher","first-page":"110579","DOI":"10.1016\/j.injury.2023.01.017","volume":"54","author":"G Boni","year":"2023","unstructured":"Boni G, Pires RE, Sanchez GT, Giordano V (2023) Antegrade posterior column screw fixation for acetabular fractures: it\u2019s time to standardize the surgical technique. Injury 54(6):110579. https:\/\/doi.org\/10.1016\/j.injury.2023.01.017","journal-title":"Injury"},{"issue":"1","key":"6604_CR10","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1186\/S13018-022-03347-3","volume":"17","author":"K Yu","year":"2022","unstructured":"Yu K, Zhou R, Gao S et al (2022) The placement of percutaneous retrograde acetabular posterior column screw based on imaging anatomical study of acetabular posterior column corridor. J Orthop Surg Res 17(1):492. https:\/\/doi.org\/10.1186\/S13018-022-03347-3","journal-title":"J Orthop Surg Res"},{"key":"6604_CR11","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/S1048-6666(01)80008-2","volume":"11","author":"AJ Starr","year":"2001","unstructured":"Starr AJ, Borer DS, Reinert CM (2001) Technical aspects of limited open reduction and percutaneous screw fixation of fractures of the acetabulum. Oper Tech Orthop 11:218\u2013226. https:\/\/doi.org\/10.1016\/S1048-6666(01)80008-2","journal-title":"Oper Tech Orthop"},{"key":"6604_CR12","doi-asserted-by":"publisher","first-page":"899","DOI":"10.5435\/JAAOS-D-18-00102","volume":"27","author":"D Banaszek","year":"2019","unstructured":"Banaszek D, Starr AJ, Lefaivre KA (2019) Technical considerations and fluoroscopy in percutaneous fixation of the pelvis and acetabulum. J Am Acad Orthop Surg 27:899\u2013908. https:\/\/doi.org\/10.5435\/JAAOS-D-18-00102","journal-title":"J Am Acad Orthop Surg"},{"key":"6604_CR13","doi-asserted-by":"publisher","first-page":"811","DOI":"10.5435\/JAAOS-D-21-00066","volume":"29","author":"M Hadeed","year":"2021","unstructured":"Hadeed M, Heare A, Parry J, Mauffrey C (2021) Anatomical considerations in percutaneous fixation of the pelvis and acetabulum. J Am Acad Orthop Surg 29:811\u2013819. https:\/\/doi.org\/10.5435\/JAAOS-D-21-00066","journal-title":"J Am Acad Orthop Surg"},{"key":"6604_CR14","doi-asserted-by":"publisher","first-page":"103872","DOI":"10.1016\/J.OTSR.2024.103872","volume":"110","author":"V \u00d6zt\u00fcrk","year":"2024","unstructured":"\u00d6zt\u00fcrk V, \u00c7elik M, Koluman AC et al (2024) Fluroscopy-assisted transiliac antegrade lag screw placement technique in both columns of acetabulum: A novel procedure. Orthop Traumatol Surg Res 110:103872. https:\/\/doi.org\/10.1016\/J.OTSR.2024.103872","journal-title":"Orthop Traumatol Surg Res"},{"key":"6604_CR15","doi-asserted-by":"publisher","unstructured":"\u00d6zt\u00fcrk V, Bilgili MG (2024) Combining innovative techniques: total extraperitoneal approach in orthopedic surgery (O-TEP) and percutaneous both column screw (BCS) fixation technique in a geriatric acetabular fracture case. https:\/\/doi.org\/10.1055\/A-2370-0086. Z Orthop Unfall","DOI":"10.1055\/A-2370-0086"},{"key":"6604_CR16","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.2106\/00004623-196446080-00001","volume":"46","author":"R JUDET","year":"1964","unstructured":"JUDET R, JUDET J, LETOURNEL E (1964) FRACTURES OF THE ACETABULUM: CLASSIFICATION AND SURGICAL APPROACHES FOR OPEN REDUCTION. PRELIMINARY REPORT. J Bone Joint Surg Am 46:1615\u20131646","journal-title":"J Bone Joint Surg Am"},{"key":"6604_CR17","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/S0736-0266(01)00185-1","volume":"20","author":"DL Kopperdahl","year":"2002","unstructured":"Kopperdahl DL, Morgan EF, Keaveny TM (2002) Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone. J Orthop Res 20:801\u2013805. https:\/\/doi.org\/10.1016\/S0736-0266(01)00185-1","journal-title":"J Orthop Res"},{"key":"6604_CR18","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1146\/ANNUREV.BIOENG.3.1.307","volume":"3","author":"TM Keaveny","year":"2001","unstructured":"Keaveny TM, Morgan EF, Niebur GL, Yeh OC (2001) Biomechanics of trabecular bone. Annu Rev Biomed Eng 3:307\u2013333. https:\/\/doi.org\/10.1146\/ANNUREV.BIOENG.3.1.307","journal-title":"Annu Rev Biomed Eng"},{"key":"6604_CR19","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1016\/S0021-9290(03)00071-X","volume":"36","author":"EF Morgan","year":"2003","unstructured":"Morgan EF, Bayraktar HH, Keaveny TM (2003) Trabecular bone modulus-density relationships depend on anatomic site. J Biomech 36:897\u2013904. https:\/\/doi.org\/10.1016\/S0021-9290(03)00071-X","journal-title":"J Biomech"},{"key":"6604_CR20","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/0021-9290(93)90042-D","volume":"26","author":"JY Rho","year":"1993","unstructured":"Rho JY, Ashman RB, Turner CH (1993) Young\u2019s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech 26:111\u2013119. https:\/\/doi.org\/10.1016\/0021-9290(93)90042-D","journal-title":"J Biomech"},{"key":"6604_CR21","doi-asserted-by":"publisher","unstructured":"Cowin SC (2001) Bone Mechanics Handbook. 2nd ed. Boca Raton, Bone Mech Handb. https:\/\/doi.org\/10.1201\/B14263","DOI":"10.1201\/B14263"},{"key":"6604_CR22","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/J.CLINBIOMECH.2007.08.024","volume":"23","author":"B Helgason","year":"2008","unstructured":"Helgason B, Perilli E, Schileo E et al (2008) Mathematical relationships between bone density and mechanical properties: A literature review. Clin Biomech 23:135\u2013146. https:\/\/doi.org\/10.1016\/J.CLINBIOMECH.2007.08.024","journal-title":"Clin Biomech"},{"key":"6604_CR23","doi-asserted-by":"publisher","first-page":"5290","DOI":"10.1007\/S11665-021-05753-W\/FIGURES\/6","volume":"30","author":"N Eshawish","year":"2021","unstructured":"Eshawish N, Malinov S, Sha W, Walls P (2021) Microstructure and mechanical properties of Ti-6Al-4V manufactured by selective laser melting after stress relieving, hot isostatic pressing treatment, and Post-Heat treatment. J Mater Eng Perform 30:5290\u20135296. https:\/\/doi.org\/10.1007\/S11665-021-05753-W\/FIGURES\/6","journal-title":"J Mater Eng Perform"},{"key":"6604_CR24","doi-asserted-by":"publisher","first-page":"3517","DOI":"10.1016\/j.jbiomech.2015.07.012","volume":"48","author":"NB Damm","year":"2015","unstructured":"Damm NB, Morlock MM, Bishop NE (2015) Friction coefficient and effective interference at the implant-bone interface. J Biomech 48:3517\u20133521. https:\/\/doi.org\/10.1016\/j.jbiomech.2015.07.012","journal-title":"J Biomech"},{"key":"6604_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cvsm.2019.08.009","volume":"50","author":"S Roe","year":"2020","unstructured":"Roe S (2020) Biomechanics of fracture fixation. Vet clin North am -. Small Anim Pract 50:1\u201315. https:\/\/doi.org\/10.1016\/j.cvsm.2019.08.009","journal-title":"Small Anim Pract"},{"key":"6604_CR26","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.2106\/JBJS.17.01298","volume":"100","author":"G Bergmann","year":"2018","unstructured":"Bergmann G, Bender A, Dymke J et al (2018) Physical activities that cause high friction moments at the cup in hip implants. J Bone Jt Surg - Am Vol 100:1637\u20131644. https:\/\/doi.org\/10.2106\/JBJS.17.01298","journal-title":"J Bone Jt Surg - Am Vol"},{"key":"6604_CR27","unstructured":"Orthoload Database Result file: h4l_111111_2_60.akf, Julius Wolff Institute, Charit\u00e9\u2013 Universit\u00e4tsmedizin Berlin; Available from: https:\/\/orthoload.com\/wp-content\/files\/file\/result\/h4l_111111_2_60.akf, Accessed 28 April 2025"},{"key":"6604_CR28","unstructured":"Orthoload Database Result file: h4l_170211_2_147.akf, Julius Wolff Institute, Charit\u00e9\u2013 Universit\u00e4tsmedizin Berlin; Available from: https:\/\/orthoload.com\/wp-content\/files\/file\/result\/h4l_170211_2_147.akf, Accessed 28 April 2025"},{"key":"6604_CR29","unstructured":"Orthoload Database Result file: h4l_240211_2_109.akf, Julius Wolff Institute, Charit\u00e9\u2013 Universit\u00e4tsmedizin Berlin; Available from: https:\/\/orthoload.com\/wp-content\/files\/file\/result\/h4l_240211_2_109.akf, Accessed 28 April 2025"},{"key":"6604_CR30","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1007\/BF02433653","volume":"316","author":"E Letournel","year":"1966","unstructured":"Letournel E (1966) [Surgical management of hip joint-acetabulum fractures]. Langenbecks Arch Chir 316:422\u2013445. https:\/\/doi.org\/10.1007\/BF02433653","journal-title":"Langenbecks Arch Chir"},{"key":"6604_CR31","doi-asserted-by":"publisher","first-page":"4561","DOI":"10.1007\/S00402-024-05471-7\/FIGURES\/6","volume":"144","author":"D Krappinger","year":"2024","unstructured":"Krappinger D, G\u00e4nsslen A, Wilde L, Lindtner RA (2024) Acetabular posterior column screws via an anterior approach. Arch Orthop Trauma Surg 144:4561\u20134568. https:\/\/doi.org\/10.1007\/S00402-024-05471-7\/FIGURES\/6","journal-title":"Arch Orthop Trauma Surg"},{"key":"6604_CR32","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/00005131-199801000-00009","volume":"12","author":"AJ Starr","year":"1998","unstructured":"Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12:51\u201358. https:\/\/doi.org\/10.1097\/00005131-199801000-00009","journal-title":"J Orthop Trauma"},{"key":"6604_CR33","doi-asserted-by":"publisher","first-page":"103288","DOI":"10.1016\/J.OTSR.2022.103288","volume":"108","author":"G Cavali\u00e9","year":"2022","unstructured":"Cavali\u00e9 G, Boudissa M, Kerschbaumer G et al (2022) Clinical and radiological outcomes of antegrade posterior column screw fixation of the acetabulum. Orthop Traumatol Surg Res 108:103288. https:\/\/doi.org\/10.1016\/J.OTSR.2022.103288","journal-title":"Orthop Traumatol Surg Res"},{"key":"6604_CR34","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1016\/J.INJURY.2017.01.028","volume":"48","author":"GH Jung","year":"2017","unstructured":"Jung GH, Lee Y, Kim JW, Kim Jwan (2017) Computational analysis of the safe zone for the antegrade lag screw in posterior column fixation with the anterior approach in acetabular fracture: A cadaveric study. Injury 48:608\u2013614. https:\/\/doi.org\/10.1016\/J.INJURY.2017.01.028","journal-title":"Injury"},{"key":"6604_CR35","doi-asserted-by":"publisher","first-page":"672","DOI":"10.7507\/1001-5515.202109042","volume":"39","author":"H Zhang","year":"2022","unstructured":"Zhang H, Xu Z, Liu Y et al (2022) [Biomechanical analysis of magic screw fixation for acetabular posterior column fracture]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 39:672\u2013678. https:\/\/doi.org\/10.7507\/1001-5515.202109042","journal-title":"Sheng Wu Yi Xue Gong Cheng Xue Za Zhi"},{"issue":"10","key":"6604_CR36","doi-asserted-by":"publisher","first-page":"110964","DOI":"10.1016\/J.INJURY.2023.110964","volume":"54","author":"K \u015eibar","year":"2023","unstructured":"\u015eibar K, Alemdaro\u011flu KB, Elibol FKE et al (2023) Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A Biomechanical study. Injury 54(10):110964. https:\/\/doi.org\/10.1016\/J.INJURY.2023.110964","journal-title":"Injury"},{"key":"6604_CR37","doi-asserted-by":"publisher","first-page":"100580","DOI":"10.1016\/J.TCR.2021.100580","volume":"37","author":"J Ye","year":"2021","unstructured":"Ye J, Xie L, Liu Z et al (2021) Anterograde lag screw placement in the posterior column of the acetabulum: A case report and literature review. Trauma Case Rep 37:100580. https:\/\/doi.org\/10.1016\/J.TCR.2021.100580","journal-title":"Trauma Case Rep"},{"key":"6604_CR38","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/S00264-021-05298-6\/TABLES\/4","volume":"46","author":"T Wang","year":"2022","unstructured":"Wang T, Zhao B, Yan J et al (2022) Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture. Int Orthop 46:623\u2013634. https:\/\/doi.org\/10.1007\/S00264-021-05298-6\/TABLES\/4","journal-title":"Int Orthop"},{"key":"6604_CR39","doi-asserted-by":"publisher","first-page":"2573","DOI":"10.1007\/S00402-024-05324-3","volume":"144","author":"N Hinz","year":"2024","unstructured":"Hinz N, Baumeister D, Dehoust J et al (2024) The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a Biomechanical comparison. Arch Orthop Trauma Surg 144:2573. https:\/\/doi.org\/10.1007\/S00402-024-05324-3","journal-title":"Arch Orthop Trauma Surg"},{"key":"6604_CR40","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1007\/S00068-019-01255-6","volume":"47","author":"G Osterhoff","year":"2021","unstructured":"Osterhoff G, Wulsten D, Babu S et al (2021) Antegrade versus retrograde screw fixation of anterior column acetabular fractures: a Biomechanical in vitro study. Eur J Trauma Emerg Surg 47:1307\u20131312. https:\/\/doi.org\/10.1007\/S00068-019-01255-6","journal-title":"Eur J Trauma Emerg Surg"},{"key":"6604_CR41","doi-asserted-by":"publisher","unstructured":"Yildirim AO, Alemdaroglu KB, Yuksel HY et al (2015) Finite element analysis of the stability of transverse acetabular fractures in standing and sitting positions by different fixation options. Injury 46 Suppl 2S29\u2013S35. https:\/\/doi.org\/10.1016\/J.INJURY.2015.05.029","DOI":"10.1016\/J.INJURY.2015.05.029"},{"key":"6604_CR42","doi-asserted-by":"publisher","unstructured":"\u00d6zt\u00fcrk V, \u00c7elik M, T\u0131ng\u0131r M, et al (2025) Is the both column fixation corridor a universally valid and consistent fixation pathway in pelvic and acetabular surgery? J Orthop Surg Res 16;20(1):590. https:\/\/doi.org\/10.1186\/s13018-025-06008-3","DOI":"10.1186\/s13018-025-06008-3"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-025-06604-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-025-06604-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-025-06604-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,7]],"date-time":"2025-09-07T14:33:48Z","timestamp":1757255628000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-025-06604-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,19]]},"references-count":42,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["6604"],"URL":"https:\/\/doi.org\/10.1007\/s00264-025-06604-2","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,19]]},"assertion":[{"value":"27 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted in accordance with the principles of the Declaration of Helsinki. Ethical approval was obtained from the local ethics committee (IRB decision number: 2024-03\/9, protocol code: 2024\/127).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}