{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T05:41:23Z","timestamp":1792734083319,"version":"4.5.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1007\/s00264-026-06954-5","type":"journal-article","created":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T09:55:27Z","timestamp":1784627727000},"page":"2855-2867","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Patient-Specific Instrumentation Improves Technical Execution Accuracy After Artificial Intelligence-Assisted Preoperative Planning in Medial Unicompartmental Knee Arthroplasty"],"prefix":"10.1007","volume":"50","author":[{"given":"Dehua","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaheng","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zirun","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinlong","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yafang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingyu","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gang","family":"Ji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guobin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,21]]},"reference":[{"key":"6954_CR1","doi-asserted-by":"publisher","first-page":"S84","DOI":"10.1016\/j.arth.2025.03.061","volume":"40","author":"DN Kugelman","year":"2025","unstructured":"Kugelman DN, Wu KA, Goel RK, Dilbone ES, Ryan SP, Bolognesi MP, Seyler TM, Wellman SS (2025) Comparing functional recovery between total and unicompartmental knee arthroplasty: a prospective health kit study. J Arthroplasty 40:S84\u2013S87. https:\/\/doi.org\/10.1016\/j.arth.2025.03.061","journal-title":"J Arthroplasty"},{"key":"6954_CR2","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1302\/0301-620X.107B4.BJJ-2024-0977.R1","volume":"107-B","author":"LW Arthur","year":"2025","unstructured":"Arthur LW, Jenkins C, Dodd CAF, Price AJ, Jackson WFM, Bottomley N, Alvand A, Murray DW (2025) Mid-term outcomes of the fixed-bearing lateral Oxford unicompartmental knee arthroplasty. Bone Joint J 107-B:432\u2013439. https:\/\/doi.org\/10.1302\/0301-620X.107B4.BJJ-2024-0977.R1","journal-title":"Bone Joint J"},{"key":"6954_CR3","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.jisako.2022.06.001","volume":"7","author":"ML Tay","year":"2022","unstructured":"Tay ML, Matthews BG, Monk AP, Young SW (2022) Disease progression, aseptic loosening and bearing dislocations are the main revision indications after lateral unicompartmental knee arthroplasty: a systematic review. J ISAKOS 7:132\u2013141. https:\/\/doi.org\/10.1016\/j.jisako.2022.06.001","journal-title":"J ISAKOS"},{"key":"6954_CR4","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1007\/s00402-021-04063-z","volume":"142","author":"L Thoreau","year":"2021","unstructured":"Thoreau L, Morcillo Marfil D, Thienpont E (2021) Periprosthetic fractures after medial unicompartmental knee arthroplasty: a narrative review. Arch Orthop Trauma Surg 142:2039\u20132048. https:\/\/doi.org\/10.1007\/s00402-021-04063-z","journal-title":"Arch Orthop Trauma Surg"},{"key":"6954_CR5","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-27623-4","volume":"15","author":"F Wang","year":"2025","unstructured":"Wang F, Zhao J, He W, He H, Wang Q (2025) Biomechanical analysis of femoral component malalignment in medial unicompartmental knee arthroplasty. Sci Rep 15:44071. https:\/\/doi.org\/10.1038\/s41598-025-27623-4","journal-title":"Sci Rep"},{"key":"6954_CR6","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1302\/0301-620X.107B3.BJJ-2024-0512.R2","volume":"107-B","author":"GV Ten Noever de Brauw","year":"2025","unstructured":"Ten Noever de Brauw GV, Vossen RJM, Bayoumi T, Sierevelt IN, Burger JA, Pearle AD, Kerkhoffs GMMJ, Spekenbrink-Spooren A, Zuiderbaan HA (2025) Distinct age-related modes of failure in cemented and cementless Oxford medial unicompartmental knee arthroplasty: results from 25,762 patients in the Dutch Arthroplasty Register. Bone Joint J 107-B:329\u2013336. https:\/\/doi.org\/10.1302\/0301-620X.107B3.BJJ-2024-0512.R2","journal-title":"Bone Joint J"},{"key":"6954_CR7","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1302\/0301-620X.104B5.BJJ-2021-1506.R1","volume":"104-B","author":"J Zhang","year":"2022","unstructured":"Zhang J, Ng N, Scott CEH, Blyth MJG, Haddad FS, Macpherson GJ, Patton JT, Clement ND (2022) Robotic arm-assisted versus manual unicompartmental knee arthroplasty: a systematic review and meta-analysis of the MAKO robotic system. Bone Joint J 104-B:541\u2013548. https:\/\/doi.org\/10.1302\/0301-620X.104B5.BJJ-2021-1506.R1","journal-title":"Bone Joint J"},{"key":"6954_CR8","doi-asserted-by":"publisher","first-page":"627","DOI":"10.2106\/JBJS.15.00664","volume":"98","author":"SW Bell","year":"2016","unstructured":"Bell SW, Anthony I, Jones B, MacLean A, Rowe P, Blyth M (2016) Improved accuracy of component positioning with robotic-assisted unicompartmental knee arthroplasty: data from a prospective, randomized controlled study. J Bone Joint Surg Am 98:627\u2013635. https:\/\/doi.org\/10.2106\/JBJS.15.00664","journal-title":"J Bone Joint Surg Am"},{"key":"6954_CR9","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/j.arth.2022.02.029","volume":"37","author":"GS Goh","year":"2022","unstructured":"Goh GS, Haffar A, Tarabichi S, Courtney PM, Krueger CA, Lonner JH (2022) Robotic-assisted versus manual unicompartmental knee arthroplasty: a time-driven activity-based cost analysis. J Arthroplasty 37:1023\u20131028. https:\/\/doi.org\/10.1016\/j.arth.2022.02.029","journal-title":"J Arthroplasty"},{"key":"6954_CR10","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s00167-021-06814-2","volume":"31","author":"ML Tay","year":"2022","unstructured":"Tay ML, Carter M, Bolam SM, Zeng N, Young SW (2022) Robotic-arm assisted unicompartmental knee arthroplasty system has a learning curve of 11 cases and increased operating time. Knee Surg Sports Traumatol Arthrosc 31:793\u2013802. https:\/\/doi.org\/10.1007\/s00167-021-06814-2","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR11","doi-asserted-by":"publisher","first-page":"4487","DOI":"10.1097\/JS9.0000000000002514","volume":"111","author":"G Cao","year":"2025","unstructured":"Cao G, Du M, Li Z, An S, Huang J, Liu S, Huang Y (2025) Novel patient-specific instrument with comparable accuracy to robotic assistance in medial unicompartmental knee arthroplasty: a prospective study. Int J Surg 111:4487\u20134494. https:\/\/doi.org\/10.1097\/JS9.0000000000002514","journal-title":"Int J Surg"},{"key":"6954_CR12","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1007\/s00167-021-06471-5","volume":"30","author":"AM Leenders","year":"2021","unstructured":"Leenders AM, Kort NP, Koenraadt KLM, van Geenen RCI, Most J, Kerens B, Boonen B, Schotanus MGM (2021) Patient-specific instruments do not show advantage over conventional instruments in unicompartmental knee arthroplasty at 2 year follow-up: a prospective, two-centre, randomised, double-blind, controlled trial. Knee Surg Sports Traumatol Arthrosc 30:918\u2013927. https:\/\/doi.org\/10.1007\/s00167-021-06471-5","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR13","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1051\/sicotj\/2017054","volume":"3","author":"MA Hafez","year":"2017","unstructured":"Hafez MA, Moholkar K (2017) Patient-specific instruments: advantages and pitfalls. SICOT J 3:66. https:\/\/doi.org\/10.1051\/sicotj\/2017054","journal-title":"SICOT J"},{"key":"6954_CR14","doi-asserted-by":"publisher","DOI":"10.1186\/s40001-025-03572-6","volume":"30","author":"Y Deng","year":"2025","unstructured":"Deng Y, Bai X, Zhao Z, Cao L, Liu Y, Jiang Q (2025) Patient-specific vs. Oxford microplasty instrumentation in unicompartmental knee arthroplasty: a randomized controlled trial. Eur J Med Res 30:1238. https:\/\/doi.org\/10.1186\/s40001-025-03572-6","journal-title":"Eur J Med Res"},{"key":"6954_CR15","doi-asserted-by":"publisher","first-page":"1823","DOI":"10.1007\/s00167-017-4826-x","volume":"26","author":"B Kerens","year":"2017","unstructured":"Kerens B, Leenders AM, Schotanus MGM, Boonen B, Tuinebreijer WE, Emans PJ, Jong B, Kort NP (2017) Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation. Knee Surg Sports Traumatol Arthrosc 26:1823\u20131830. https:\/\/doi.org\/10.1007\/s00167-017-4826-x","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR16","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.knee.2025.02.014","volume":"54","author":"HC Rodriguez","year":"2025","unstructured":"Rodriguez HC, Rust BD, Roche MW, Gupta A (2025) Artificial intelligence and machine learning in knee arthroplasty. Knee 54:28\u201349. https:\/\/doi.org\/10.1016\/j.knee.2025.02.014","journal-title":"Knee"},{"key":"6954_CR17","doi-asserted-by":"publisher","first-page":"2538","DOI":"10.1007\/s00167-022-07037-9","volume":"30","author":"GM Schwarz","year":"2022","unstructured":"Schwarz GM, Simon S, Mitterer JA, Frank BJH, Aichmair A, Dominkus M, Hofstaetter JG (2022) Artificial intelligence enables reliable and standardized measurements of implant alignment in long leg radiographs with total knee arthroplasties. Knee Surg Sports Traumatol Arthrosc 30:2538\u20132547. https:\/\/doi.org\/10.1007\/s00167-022-07037-9","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR18","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.2022.3152247","author":"K Han","year":"2022","unstructured":"Han K, Wang Y, Chen H, Chen X, Guo J, Liu Z, Tang Y, Xiao A, Xu C, Xu Y, Yang Z, Zhang Y, Tao D (2022) A survey on vision transformer. IEEE Trans Pattern Anal Mach Intell. https:\/\/doi.org\/10.1109\/TPAMI.2022.3152247","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"6954_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.media.2017.06.012","volume":"41","author":"S Ourselin","year":"2017","unstructured":"Ourselin S, Sabuncu MR, Wells W, Joskowicz L, Unal G, Maier A (2017) The 19th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2016). Med Image Anal 41:1. https:\/\/doi.org\/10.1016\/j.media.2017.06.012","journal-title":"Med Image Anal"},{"key":"6954_CR20","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.2106\/JBJS.L.01335","volume":"95","author":"JH Park","year":"2013","unstructured":"Park JH, Rasouli MR, Mortazavi SMJ, Tokarski AT, Maltenfort MG, Parvizi J (2013) Predictors of perioperative blood loss in total joint arthroplasty. J Bone Joint Surg Am 95:1777\u20131783. https:\/\/doi.org\/10.2106\/JBJS.L.01335","journal-title":"J Bone Joint Surg Am"},{"key":"6954_CR21","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.1007\/s00167-017-4677-5","volume":"26","author":"A Alvand","year":"2017","unstructured":"Alvand A, Khan T, Jenkins C, Rees JL, Jackson WF, Dodd CAF, Murray DW, Price AJ (2017) The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study. Knee Surg Sports Traumatol Arthrosc 26:1662\u20131670. https:\/\/doi.org\/10.1007\/s00167-017-4677-5","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR22","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1007\/s00167-016-4268-x","volume":"25","author":"JAMJ van Leeuwen","year":"2016","unstructured":"van Leeuwen JAMJ, R\u00f6hrl SM (2016) Patient-specific positioning guides do not consistently achieve the planned implant position in UKA. Knee Surg Sports Traumatol Arthrosc 25:752\u2013758. https:\/\/doi.org\/10.1007\/s00167-016-4268-x","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR23","doi-asserted-by":"publisher","first-page":"1292","DOI":"10.1007\/s00167-013-2794-3","volume":"23","author":"P Volpi","year":"2013","unstructured":"Volpi P, Prospero E, Bait C, Cervellin M, Quaglia A, Redaelli A, Denti M (2013) High accuracy in knee alignment and implant placement in unicompartmental medial knee replacement when using patient-specific instrumentation. Knee Surg Sports Traumatol Arthrosc 23:1292\u20131298. https:\/\/doi.org\/10.1007\/s00167-013-2794-3","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR24","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1007\/s00167-019-05616-x","volume":"28","author":"E Thijs","year":"2019","unstructured":"Thijs E, Theeuwen D, Boonen B, van Haaren E, Hendrickx R, Vos R, Borghans R, Kort N, Schotanus MGM (2019) Comparable clinical outcome and implant longevity after CT- or MRI-based patient-specific instruments for total knee arthroplasty: a 2-year follow-up of a RCT. Knee Surg Sports Traumatol Arthrosc 28:1821\u20131826. https:\/\/doi.org\/10.1007\/s00167-019-05616-x","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6954_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.jisako.2024.100324","volume":"9","author":"NS Makaram","year":"2024","unstructured":"Makaram NS, Yapp LZ, Bowley ALW, Garner A, Scott CEH (2024) Polyethylene wear in metal-backed tibial components in unicompartmental knee prostheses. J ISAKOS 9:100324. https:\/\/doi.org\/10.1016\/j.jisako.2024.100324","journal-title":"J ISAKOS"},{"key":"6954_CR26","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.2106\/JBJS.19.01277","volume":"102","author":"GS Kazarian","year":"2020","unstructured":"Kazarian GS, Barrack TN, Okafor L, Barrack RL, Nunley RM, Lawrie CM (2020) High prevalence of radiographic outliers and revisions with unicompartmental knee arthroplasty. J Bone Joint Surg Am 102:1151\u20131159. https:\/\/doi.org\/10.2106\/JBJS.19.01277","journal-title":"J Bone Joint Surg Am"},{"key":"6954_CR27","doi-asserted-by":"publisher","first-page":"2903","DOI":"10.1016\/j.arth.2019.07.031","volume":"34","author":"J-C Escudier","year":"2019","unstructured":"Escudier J-C, Jacquet C, Flecher X, Parratte S, Ollivier M, Argenson J-N (2019) Better implant positioning and clinical outcomes with a morphometric unicompartmental knee arthroplasty. Results of a retrospective, matched-controlled study. J Arthroplasty 34:2903\u20132908. https:\/\/doi.org\/10.1016\/j.arth.2019.07.031","journal-title":"J Arthroplasty"},{"key":"6954_CR28","doi-asserted-by":"publisher","DOI":"10.1177\/10225536221149485","volume":"31","author":"Y Miyake","year":"2023","unstructured":"Miyake Y, Namba Y, Mitani S, Umehara N, Kawamoto T, Furuichi S (2023) Comparison of tibial implant positioning between symmetrical and anatomical design implants in unicompartmental knee arthroplasty for Japanese patients. J Orthop Surg (Hong Kong) 31:10225536221149485. https:\/\/doi.org\/10.1177\/10225536221149485","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"6954_CR29","doi-asserted-by":"publisher","first-page":"1694","DOI":"10.1016\/j.arth.2014.03.026","volume":"29","author":"DP Carpenter","year":"2014","unstructured":"Carpenter DP, Holmberg RR, Quartulli MJ, Barnes CL (2014) Tibial plateau coverage in UKA: a comparison of patient specific and off-the-shelf implants. J Arthroplasty 29:1694\u20131698. https:\/\/doi.org\/10.1016\/j.arth.2014.03.026","journal-title":"J Arthroplasty"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-026-06954-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-026-06954-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-026-06954-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T05:33:05Z","timestamp":1792733585000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-026-06954-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,21]]},"references-count":29,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["6954"],"URL":"https:\/\/doi.org\/10.1007\/s00264-026-06954-5","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,21]]},"assertion":[{"value":"31 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethical approval for this prospective randomized study was obtained from the Ethics Committee of our institution on 10 November 2025 (approval number: 2025-YanShen00212). The study was registered in the China Medical Research Registration and Filing Information System (MR-13\u201326-020943). Written informed consent was obtained from all participants before enrolment.","order":1,"name":"Ethics","label":"Ethics approval statement","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}