{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T01:00:29Z","timestamp":1790643629451,"version":"4.1.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["International Orthopaedics (SICOT)"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1007\/s00264-026-07019-3","type":"journal-article","created":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T01:30:27Z","timestamp":1788399027000},"page":"2681-2689","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Three dimensional\u00a0printed patient-specific PEEK versus titanium mesh cage for anterior column reconstruction after spondylectomy for spinal tumours: a prospective controlled cohort study"],"prefix":"10.1007","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4562-8160","authenticated-orcid":false,"given":"Nikta","family":"Zaborovskii","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergei","family":"Masevnin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dmitrii","family":"Ptashnikov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rashid","family":"Tikhilov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,3]]},"reference":[{"key":"7019_CR1","doi-asserted-by":"publisher","first-page":"668","DOI":"10.21037\/jss.2018.09.02","volume":"4","author":"S Boriani","year":"2018","unstructured":"Boriani S (2018) En bloc resection in the spine: a procedure of surgical oncology. J Spine Surg 4:668\u2013676. https:\/\/doi.org\/10.21037\/jss.2018.09.02","journal-title":"J Spine Surg"},{"key":"7019_CR2","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1055\/a-1017-3968","volume":"159","author":"A Kasapovic","year":"2021","unstructured":"Kasapovic A, Bornemann R, Pflugmacher R, Rommelspacher Y (2021) Implants for vertebral body replacement - which systems are available and have become established. Z Orthop Unfall 159:83\u201390. https:\/\/doi.org\/10.1055\/a-1017-3968","journal-title":"Z Orthop Unfall"},{"key":"7019_CR3","doi-asserted-by":"publisher","DOI":"10.1177\/21925682221120644","author":"Z Li","year":"2022","unstructured":"Li Z, Guo L, Zhang P et al (2022) A systematic review of perioperative complications in en bloc resection for spinal tumors. Glob Spine J. https:\/\/doi.org\/10.1177\/21925682221120644","journal-title":"Glob Spine J"},{"key":"7019_CR4","doi-asserted-by":"publisher","first-page":"e106","DOI":"10.1016\/j.wneu.2019.11.057","volume":"135","author":"Z Li","year":"2020","unstructured":"Li Z, Wei F, Liu Z et al (2020) Risk factors for instrumentation failure after total en bloc spondylectomy of thoracic and lumbar spine tumors using titanium mesh cage for anterior reconstruction. World Neurosurg 135:e106\u2013e115. https:\/\/doi.org\/10.1016\/j.wneu.2019.11.057","journal-title":"World Neurosurg"},{"key":"7019_CR5","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1007\/s00586-019-06276-8","volume":"29","author":"P Berjano","year":"2020","unstructured":"Berjano P, Cecchinato R, Pun A, Boriani S (2020) Revision surgery for tumors of the thoracic and lumbar spine: causes, prevention, and treatment strategy. Eur Spine J 29:66\u201377. https:\/\/doi.org\/10.1007\/s00586-019-06276-8","journal-title":"Eur Spine J"},{"key":"7019_CR6","doi-asserted-by":"publisher","first-page":"139","DOI":"10.21823\/2311-2905-2020-26-2-139-147","volume":"26","author":"SV Kolesov","year":"2020","unstructured":"Kolesov SV, Kazmin AI et al (2020) Cage subsidence after surgery on the anterior part of the subaxial cervical spine: a monocentric prospective clinical study with a 3-year follow-up. Traumatol Orthop Russia 26:139\u2013147. https:\/\/doi.org\/10.21823\/2311-2905-2020-26-2-139-147","journal-title":"Traumatol Orthop Russia"},{"key":"7019_CR7","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1186\/s12891-022-05919-0","volume":"23","author":"H Xu","year":"2022","unstructured":"Xu H, Wang X, Han Y et al (2022) Biomechanical comparison of different prosthetic reconstructions in total en bloc spondylectomy: a finite element study. BMC Musculoskelet Disord 23:955. https:\/\/doi.org\/10.1186\/s12891-022-05919-0","journal-title":"BMC Musculoskelet Disord"},{"key":"7019_CR8","doi-asserted-by":"publisher","first-page":"489","DOI":"10.3390\/life12040489","volume":"12","author":"R Costanzo","year":"2022","unstructured":"Costanzo R, Ferini G, Brunasso L et al (2022) The role of 3D-printed custom-made vertebral body implants in the treatment of spinal tumors: a systematic review. Life (Basel) 12:489. https:\/\/doi.org\/10.3390\/life12040489","journal-title":"Life (Basel)"},{"key":"7019_CR9","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1530\/EOR-23-0066","volume":"8","author":"D Kotrych","year":"2023","unstructured":"Kotrych D, Angelini A, Bohatyrewicz A, Ruggieri P (2023) 3D printing for patient-specific implants in musculoskeletal oncology. EFORT Open Rev 8:331\u2013339. https:\/\/doi.org\/10.1530\/EOR-23-0066","journal-title":"EFORT Open Rev"},{"key":"7019_CR10","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.wneu.2021.01.059","volume":"148","author":"N Kumar","year":"2021","unstructured":"Kumar N, Ramakrishnan SA, Lopez KG et al (2021) Can polyether ether ketone dethrone titanium as the choice implant material for metastatic spine tumor surgery? World Neurosurg 148:94\u2013109. https:\/\/doi.org\/10.1016\/j.wneu.2021.01.059","journal-title":"World Neurosurg"},{"key":"7019_CR11","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s40204-022-00214-6","volume":"12","author":"P Rendas","year":"2023","unstructured":"Rendas P, Figueiredo L, Machado C et al (2023) Mechanical performance and bioactivation of 3D-printed PEEK for high-performance implant manufacture: a review. Prog Biomater 12:89\u2013111. https:\/\/doi.org\/10.1007\/s40204-022-00214-6","journal-title":"Prog Biomater"},{"key":"7019_CR12","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.jor.2024.10.024","volume":"62","author":"N Zaborovskii","year":"2025","unstructured":"Zaborovskii N, Masevnin S, Smekalenkov O et al (2025) Patient-specific 3D-printed PEEK implants for spinal tumor surgery. J Orthop 62:99\u2013105. https:\/\/doi.org\/10.1016\/j.jor.2024.10.024","journal-title":"J Orthop"},{"key":"7019_CR13","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/1301028","author":"P Honigmann","year":"2021","unstructured":"Honigmann P, Sharma N, Schumacher R et al (2021) In-hospital 3D printed scaphoid prosthesis using medical-grade Polyetheretherketone (PEEK) biomaterial. BioMed Res Int. https:\/\/doi.org\/10.1155\/2021\/1301028","journal-title":"BioMed Res Int"},{"key":"7019_CR14","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1186\/s12957-023-03271-8","volume":"21","author":"J Hu","year":"2023","unstructured":"Hu J, Song G, Chen H et al (2023) Surgical outcomes and risk factors for surgical complications after en bloc resection following reconstruction with 3D-printed artificial vertebral body for thoracolumbar tumors. World J Surg Oncol 21:385. https:\/\/doi.org\/10.1186\/s12957-023-03271-8","journal-title":"World J Surg Oncol"},{"key":"7019_CR15","doi-asserted-by":"publisher","first-page":"179","DOI":"10.17816\/2311-2905-17750","volume":"31","author":"NS Zaborovskii","year":"2025","unstructured":"Zaborovskii NS, Shailieva SL, Masevnin SV et al (2025) Subsidence of vertebral body replacement prostheses in spinal tumors: a systematic review. Traumatol Ortop Ross 31:179\u2013188. https:\/\/doi.org\/10.17816\/2311-2905-17750","journal-title":"Traumatol Ortop Ross"},{"key":"7019_CR16","doi-asserted-by":"publisher","first-page":"31","DOI":"10.22603\/ssrr.1.2016-0005","volume":"1","author":"K Yoshioka","year":"2017","unstructured":"Yoshioka K, Murakami H, Demura S et al (2017) Risk factors of instrumentation failure after multilevel total en bloc spondylectomy. Spine Surg Relat Res 1:31\u201339. https:\/\/doi.org\/10.22603\/ssrr.1.2016-0005","journal-title":"Spine Surg Relat Res"},{"key":"7019_CR17","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1007\/s00586-022-07480-9","volume":"32","author":"Z Chen","year":"2023","unstructured":"Chen Z, L\u00fc G, Wang X et al (2023) Is 3D-printed prosthesis stable and economic enough for anterior spinal column reconstruction after spinal tumor resection? A retrospective comparative study between 3D-printed off-the-shelf prosthesis and titanium mesh cage. Eur Spine J 32:261\u2013270. https:\/\/doi.org\/10.1007\/s00586-022-07480-9","journal-title":"Eur Spine J"},{"key":"7019_CR18","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1302\/0301-620X.105B2.BJJ-2022-0761.R2","volume":"105-B","author":"T Shimizu","year":"2023","unstructured":"Shimizu T, Kato S, Demura S et al (2023) Characteristics and risk factors of instrumentation failure following total en bloc spondylectomy. Bone Joint J 105-B:172\u2013179. https:\/\/doi.org\/10.1302\/0301-620X.105B2.BJJ-2022-0761.R2","journal-title":"Bone Joint J"},{"key":"7019_CR19","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/BRS.0000000000004177","volume":"47","author":"FH Shen","year":"2022","unstructured":"Shen FH, Gasbarrini A, Lui DF et al (2022) Integrated custom composite Polyetheretherketone\/Carbon fiber (PEEK\/CF) vertebral body replacement (VBR) in the treatment of bone tumors of the spine: a preliminary report from a multicenter study. Spine 47:252. https:\/\/doi.org\/10.1097\/BRS.0000000000004177","journal-title":"Spine"},{"key":"7019_CR20","doi-asserted-by":"publisher","first-page":"576","DOI":"10.18063\/ijb.v8i3.576","volume":"8","author":"X Hu","year":"2022","unstructured":"Hu X, Kenan S, Cheng M et al (2022) 3D-printed patient-customized artificial vertebral body for spinal reconstruction after total en bloc spondylectomy of complex multi-level spinal tumors. Int J Bioprint 8:576. https:\/\/doi.org\/10.18063\/ijb.v8i3.576","journal-title":"Int J Bioprint"},{"key":"7019_CR21","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2024.1327319","author":"M Dong","year":"2024","unstructured":"Dong M, Gao Y, Fan H et al (2024) Comparison of clinical efficacy of 3D-printed artificial vertebral body and conventional titanium mesh cage in spinal reconstruction after total en bloc spondylectomy for spinal tumors: a systematic review and meta-analysis. Front Oncol. https:\/\/doi.org\/10.3389\/fonc.2024.1327319","journal-title":"Front Oncol"},{"key":"7019_CR22","doi-asserted-by":"publisher","first-page":"18767","DOI":"10.1038\/s41598-023-45736-6","volume":"13","author":"AJ Pokorni","year":"2023","unstructured":"Pokorni AJ, Turbucz M, Kiss RM et al (2023) Comparison of anterior column reconstruction techniques after en bloc spondylectomy: a finite element study - Scientific Reports. Sci Rep 13:18767. https:\/\/doi.org\/10.1038\/s41598-023-45736-6","journal-title":"Sci Rep"},{"key":"7019_CR23","doi-asserted-by":"publisher","first-page":"101","DOI":"10.14245\/ns.1938296.148","volume":"17","author":"A Warburton","year":"2020","unstructured":"Warburton A, Girdler SJ, Mikhail CM et al (2020) Biomaterials in spinal implants: a review. Neurospine 17:101\u2013110. https:\/\/doi.org\/10.14245\/ns.1938296.148","journal-title":"Neurospine"},{"key":"7019_CR24","doi-asserted-by":"publisher","first-page":"163","DOI":"10.21037\/jss.2017.05.01","volume":"3","author":"RF Heary","year":"2017","unstructured":"Heary RF, Parvathreddy N, Sampath S, Agarwal N (2017) Elastic modulus in the selection of interbody implants. J Spine Surg 3:163\u2013167. https:\/\/doi.org\/10.21037\/jss.2017.05.01","journal-title":"J Spine Surg"},{"key":"7019_CR25","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1043\/0003-3219(2004)074<0003:AUOBPA>2.0.CO;2","volume":"74","author":"HM Frost","year":"2004","unstructured":"Frost HM (2004) A 2003 update of bone physiology and Wolff\u2019s law for clinicians. Angle Orthod 74:3\u201315. https:\/\/doi.org\/10.1043\/0003-3219(2004)074%3c0003:AUOBPA%3e2.0.CO;2","journal-title":"Angle Orthod"},{"key":"7019_CR26","doi-asserted-by":"publisher","first-page":"53","DOI":"10.15593\/RJBiomech\/2025.1.04","volume":"29","author":"O Shosheva","year":"2025","unstructured":"Shosheva O, Zhmaylo M, Maslov L et al (2025) Comparative analysis of lumbar spine reconstruction using implants made of homogeneous PEEK and lattice titanium. Russ J Biomech 29:53\u201373. https:\/\/doi.org\/10.15593\/RJBiomech\/2025.1.04","journal-title":"Russ J Biomech"},{"key":"7019_CR27","doi-asserted-by":"publisher","first-page":"603","DOI":"10.14444\/8685","volume":"18","author":"N Kumar","year":"2024","unstructured":"Kumar N, Kumar P, Zihui GL et al (2024) Nonmetallic carbon fiber-reinforced polyetheretherketone implants vs titanium implants: analysis of clinical outcomes and influence on postoperative radiotherapy planning in metastatic spine tumor surgery. Int J Spine Surg 18:603\u2013610. https:\/\/doi.org\/10.14444\/8685","journal-title":"Int J Spine Surg"},{"key":"7019_CR28","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s11060-024-04842-9","volume":"171","author":"J Ward","year":"2025","unstructured":"Ward J, Damante M, Wilson S et al (2025) Impact of instrumentation material on local recurrence: a case-matched series using carbon fiber-PEEK vs. titanium. J Neurooncol 171:155\u2013162. https:\/\/doi.org\/10.1007\/s11060-024-04842-9","journal-title":"J Neurooncol"},{"key":"7019_CR29","doi-asserted-by":"publisher","first-page":"274","DOI":"10.3171\/2022.1.SPINE21900","volume":"37","author":"H Zhou","year":"2022","unstructured":"Zhou H, Liu S, Li Z et al (2022) 3D-printed vertebral body for anterior spinal reconstruction in patients with thoracolumbar spinal tumors. J Neurosurg Spine 37:274\u2013282. https:\/\/doi.org\/10.3171\/2022.1.SPINE21900","journal-title":"J Neurosurg Spine"},{"key":"7019_CR30","doi-asserted-by":"publisher","first-page":"439","DOI":"10.5937\/scriptamed56-59057","volume":"56","author":"G Demyashkin","year":"2025","unstructured":"Demyashkin G, Durasov M, Muraev A et al (2025) Assessment of local tissue responses to subcutaneous implantation of Polyetheretherketone and Polymethyl methacrylate-based materials. Scr Med 56:439\u2013449. https:\/\/doi.org\/10.5937\/scriptamed56-59057","journal-title":"Scr Med"}],"container-title":["International Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-026-07019-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00264-026-07019-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00264-026-07019-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:09:58Z","timestamp":1790640598000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00264-026-07019-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":30,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["7019"],"URL":"https:\/\/doi.org\/10.1007\/s00264-026-07019-3","relation":{},"ISSN":["0341-2695","1432-5195"],"issn-type":[{"value":"0341-2695","type":"print"},{"value":"1432-5195","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]},"assertion":[{"value":"23 July 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the Institutional Review Board of Vreden National Medical Research Center of Traumatology and Orthopedics (IRB \u2116 00324-1, 02.09.2021) and complied with the Declaration of Helsinki and International Ethical Guidelines for Biomedical Research.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}