{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T14:25:36Z","timestamp":1787063136986,"version":"build-2736575974"},"reference-count":30,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2021,6,23]],"date-time":"2021-06-23T00:00:00Z","timestamp":1624406400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2021,6,23]],"date-time":"2021-06-23T00:00:00Z","timestamp":1624406400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,6,23]],"date-time":"2021-06-23T00:00:00Z","timestamp":1624406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81470896"],"award-info":[{"award-number":["81470896"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81470896"],"award-info":[{"award-number":["81470896"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["World j. surg."],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Cholangiojejunostomy (CJ) is a popular operation; however, no specific anastomotic device is available. A novel magnamosis device for CJ was developed in 2017; here, we evaluated the feasibility and safety of the device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Between January 2017 and December 2019, 23 patients who underwent CJ using a novel magnamosis device were enrolled. For the CJ: the parent magnet was placed in the proximal duct, and the purse\u2013string suture was tightened over the rod of the parent magnet. The magnamosis device was introduced into the jejunum, and the mandrel penetrated the jejunum at the anastomotic site, before insertion into the rod of the parent magnet. After rotating the knob, the distance between two magnets was shortened enough to achieve coupling.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Sixteen patients (69.6%) underwent open CJ, while 7 (30.4%) underwent laparoscopic CJ; 21 patients (91.3%) underwent choledochojejunostomy, and 2 (8.7%) underwent right or left hepatic duct jejunostomy. The mean time for completion of CJ was 9.2\u00b12.5\u00a0min; it was significantly shorter for open CJ than for the laparoscopic way (8\u00b11.2\u00a0min vs. 11.8\u00b12.5\u00a0min,\n                      <jats:italic>P<\/jats:italic>\n                      &lt;0.05). Only one patient (4.3%) suffered bile leakage after operation and was cured by conservative treatment. The magnets were discharged with a postoperative duration of 66.7\u00b147.2\u00a0days, with a 100% expulsion rate. After a median follow\u2010up of 15\u00a0months, only one patient (4.3%) developed inflammatory anastomotic stricture.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The novel magnamosis device is a simple, safe, and effective modality for CJ.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00268-021-06196-z","type":"journal-article","created":{"date-parts":[[2021,6,23]],"date-time":"2021-06-23T10:05:40Z","timestamp":1624442740000},"page":"3138-3145","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Cholangiojejunostomy Using a Novel Magnamosis Device: Initial Clinical Results"],"prefix":"10.1002","volume":"45","author":[{"given":"Yu","family":"Li","sequence":"first","affiliation":[{"name":"Department of Hepatobiliary Surgery The First Affiliated Hospital of Xi'an Jiaotong University 710061 Xi'an China"},{"name":"National Local Joint Engineering Research Center for Precision Surgery &amp; Regenerative Medicine 710061 Xi'an China"},{"name":"Shaanxi Province Center for Regenerative Medicine and Surgery Engineering Research 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xue\u2010min","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery The First Affiliated Hospital of Xi'an Jiaotong University 710061 Xi'an China"},{"name":"National Local Joint Engineering Research Center for Precision Surgery &amp; Regenerative Medicine 710061 Xi'an China"},{"name":"Shaanxi Province Center for Regenerative Medicine and Surgery Engineering Research 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong\u2010ke","family":"Zhang","sequence":"additional","affiliation":[{"name":"National Local Joint Engineering Research Center for Precision Surgery &amp; Regenerative Medicine 710061 Xi'an China"},{"name":"Shaanxi Province Center for Regenerative Medicine and Surgery Engineering Research 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xu\u2010feng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery The First Affiliated Hospital of Xi'an Jiaotong University 710061 Xi'an China"},{"name":"National Local Joint Engineering Research Center for Precision Surgery &amp; Regenerative Medicine 710061 Xi'an China"},{"name":"Shaanxi Province Center for Regenerative Medicine and Surgery Engineering Research 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Tang","sequence":"additional","affiliation":[{"name":"National Local Joint Engineering Research Center for Precision Surgery &amp; Regenerative Medicine 710061 Xi'an China"},{"name":"Shaanxi Province Center for Regenerative Medicine and Surgery Engineering Research 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji\u2010gang","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery The First Affiliated Hospital of Xi'an Jiaotong University 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Lv","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery The First Affiliated Hospital of Xi'an Jiaotong University 710061 Xi'an China"},{"name":"National Local Joint Engineering Research Center for Precision Surgery &amp; Regenerative Medicine 710061 Xi'an China"},{"name":"Shaanxi Province Center for Regenerative Medicine and Surgery Engineering Research 710061 Xi'an China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2021,6,23]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.tp.0000446273.13310.77"},{"key":"e_1_2_8_3_1","first-page":"e921896","article-title":"A modified suture technique in hepaticojejunostomy","volume":"26","author":"Li G","year":"2020","journal-title":"Med Sci Monit"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13304\u2010011\u20100102\u20107"},{"key":"e_1_2_8_5_1","first-page":"177","article-title":"Choledochojejunostomy using a mechanical stapler","volume":"51","author":"Cirocchi R","year":"1999","journal-title":"Chir Ital"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.21037\/hbsn.2019.03.01"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00268\u2010018\u20104710\u2010y"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2018.11.010"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/jgh.14500"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2017.07.1062"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2016.08.047"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00464\u2010019\u201007063\u20108"},{"issue":"1283","key":"e_1_2_8_13_1","first-page":"294","article-title":"Magnetic recanalization technique for the treatment of alimentary tract stricture: a clinical study","volume":"65","author":"Li Yu","year":"2020","journal-title":"Ch Sci Bull"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1055\/s\u20100038\u20101649489"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00192\u2010016\u20103097\u20102"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2017.05.094"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.sla.0000133083.54934.ae"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsu.2010.06.013"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11605\u2010009\u20101131\u20100"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11605\u2010012\u20101903\u20109"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2007.02.021"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13054\u2010018\u20102160\u20104"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00464\u2010017\u20105740\u20105"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1499\u20103872(11)60129\u2010X"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2012.04.003"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2007.09.014"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v22.i7.2326"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2009.01.019"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2016.05.021"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11605\u2010017\u20103532\u20109"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1499\u20103872(17)60033\u2010X"}],"container-title":["World Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00268-021-06196-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00268-021-06196-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00268-021-06196-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1007\/s00268-021-06196-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,23]],"date-time":"2023-12-23T11:51:11Z","timestamp":1703332271000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1007\/s00268-021-06196-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,23]]},"references-count":30,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["10.1007\/s00268-021-06196-z"],"URL":"https:\/\/doi.org\/10.1007\/s00268-021-06196-z","archive":["Portico"],"relation":{},"ISSN":["0364-2313","1432-2323"],"issn-type":[{"value":"0364-2313","type":"print"},{"value":"1432-2323","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,23]]},"assertion":[{"value":"31 May 2021","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2021","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare that they have no disclosures to report.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical consent was given by the ethical committee at the First Affiliated Hospital of Xi\u2019an Jiaotong University (XJTU1AF2015LSL-046).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All participants eligible for inclusion received full explanation of the protocol and provided informed consent. The study was carried out in accordance with the Declaration of Helsinki.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}