{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T07:33:11Z","timestamp":1768721591442,"version":"3.49.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2007,12,18]],"date-time":"2007-12-18T00:00:00Z","timestamp":1197936000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cardiovasc Intervent Radiol"],"published-print":{"date-parts":[[2008,5]]},"DOI":"10.1007\/s00270-007-9245-9","type":"journal-article","created":{"date-parts":[[2007,12,17]],"date-time":"2007-12-17T20:16:50Z","timestamp":1197922610000},"page":"460-467","source":"Crossref","is-referenced-by-count":43,"title":["Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?"],"prefix":"10.1007","volume":"31","author":[{"given":"Fabian","family":"Springer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolf W.","family":"G\u00fcnther","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Schmitz-Rode","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2007,12,18]]},"reference":[{"key":"9245_CR1","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/BF02015271","volume":"5","author":"JC Parodi","year":"1991","unstructured":"Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491\u2013499","journal-title":"Ann Vasc Surg"},{"key":"9245_CR2","first-page":"623","volume":"237","author":"WD Jordan","year":"2003","unstructured":"Jordan WD, Alcocer F, Wirthlin DJ, et\u00a0al. (2003) Abdominal aortic aneurysms in \u201chigh-risk\u201d surgical patients: Comparison of open and endovascular repair. Ann Surg 237:623\u2013629; discussion 629\u2013630","journal-title":"Ann Surg"},{"key":"9245_CR3","doi-asserted-by":"crossref","first-page":"2849","DOI":"10.1007\/s00330-005-0129-6","volume":"16","author":"J Golzarian","year":"2006","unstructured":"Golzarian J, Valenti D (2006) Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment. Eur Radiol 16:2849\u20132857","journal-title":"Eur Radiol"},{"key":"9245_CR4","first-page":"553","volume":"44","author":"SR Dubenec","year":"2003","unstructured":"Dubenec SR, White GH, Pasenau J, et\u00a0al. (2003) Endotension. A review of current views on pathophysiology and treatment. J Cardiovasc Surg (Torino) 44:553\u2013557","journal-title":"J Cardiovasc Surg (Torino)"},{"key":"9245_CR5","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1583\/1074-6218(1999)006<0305:EAEARD>2.0.CO;2","volume":"6","author":"G Gilling-Smith","year":"1999","unstructured":"Gilling-Smith G, Brennan J, Harris P, et\u00a0al. (1999) Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 6:305\u2013307","journal-title":"J Endovasc Surg"},{"key":"9245_CR6","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1583\/1074-6218(1999)006<0308:EAEFCA>2.0.CO;2","volume":"6","author":"GH White","year":"1999","unstructured":"White GH, May J, Petrasek P, et\u00a0al. (1999) Endotension: An explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg 6:308\u2013315","journal-title":"J Endovasc Surg"},{"key":"9245_CR7","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1148\/radiol.2331031767","volume":"233","author":"V Napoli","year":"2004","unstructured":"Napoli V, Bargellini I, Sardella SG, et\u00a0al. (2004) Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217\u2013225","journal-title":"Radiology"},{"key":"9245_CR8","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1067\/mva.2001.112215","volume":"33","author":"A d\u2019Audiffret","year":"2001","unstructured":"d\u2019Audiffret A, Desgranges P, Kobeiter DH, et\u00a0al. (2001) Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: Validation with computed tomography. J Vasc Surg 33:42\u201350","journal-title":"J Vasc Surg"},{"key":"9245_CR9","doi-asserted-by":"crossref","first-page":"2443","DOI":"10.1007\/s00330-002-1429-8","volume":"12","author":"M Cejna","year":"2002","unstructured":"Cejna M, Loewe C, Schoder M, et\u00a0al. (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Eur Radiol 12:2443\u20132450","journal-title":"Eur Radiol"},{"key":"9245_CR10","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1053\/ejvs.2001.1405","volume":"22","author":"S Haulon","year":"2001","unstructured":"Haulon S, Lions C, McFadden EP, et\u00a0al. (2001) Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysms. Eur J Vasc Endovasc Surg 22:62\u201369","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"9245_CR11","doi-asserted-by":"crossref","first-page":"W334","DOI":"10.2214\/AJR.06.0584","volume":"188","author":"RB Schwope","year":"2007","unstructured":"Schwope RB, Alper HJ, Talenfeld AD, et\u00a0al. (2007) MR angiography for patient surveillance after endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 188:W334\u2013340","journal-title":"AJR Am J Roentgenol"},{"key":"9245_CR12","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/S0033-8389(02)00024-6","volume":"40","author":"S Thurnher","year":"2002","unstructured":"Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am 40:799\u2013833","journal-title":"Radiol Clin North Am"},{"key":"9245_CR13","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1016\/j.jvs.2004.02.041","volume":"39","author":"NV Dias","year":"2004","unstructured":"Dias NV, Ivancev K, Malina M, et\u00a0al. (2004) Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. J Vasc Surg 39:1229\u20131235","journal-title":"J Vasc Surg"},{"key":"9245_CR14","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.jvs.2004.07.045","volume":"40","author":"NV Dias","year":"2004","unstructured":"Dias NV, Ivancev K, Malina M, et\u00a0al. (2004) Direct intra-aneurysm sac pressure measurement using tip-pressure sensors: In\u00a0vivo and in\u00a0vitro evaluation. J Vasc Surg 40:711\u2013716","journal-title":"J Vasc Surg"},{"key":"9245_CR15","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1067\/mva.2001.111807","volume":"33","author":"RA Baum","year":"2001","unstructured":"Baum RA, Carpenter JP, Cope C, et\u00a0al. (2001) Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 33:32\u201341","journal-title":"J Vasc Surg"},{"key":"9245_CR16","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1067\/mva.2003.138","volume":"37","author":"B Sonesson","year":"2003","unstructured":"Sonesson B, Dias N, Malina M, et\u00a0al. (2003) Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair. J Vasc Surg 37:733\u2013738","journal-title":"J Vasc Surg"},{"key":"9245_CR17","doi-asserted-by":"crossref","unstructured":"Allen MG (2005) Micromachined endovascularly-implantable wireless aneurysm pressure sensors: from concept to clinic. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Digest of Technical Papers, TRANSDUCERS \u201805:275\u2013278","DOI":"10.1109\/SENSOR.2005.1496410"},{"key":"9245_CR18","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jvs.2006.09.060","volume":"45","author":"T Ohki","year":"2007","unstructured":"Ohki T, Ouriel K, Silveira PG, et\u00a0al. (2007) Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial\u2014Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion. J Vasc Surg 45:236\u2013242","journal-title":"J Vasc Surg"},{"issue":"Suppl","key":"9245_CR19","first-page":"1","volume":"10","author":"T Ohki","year":"2003","unstructured":"Ohki T, Yadav J, Gargiulo N, et\u00a0al. (2003) Preliminary results of an implantable wireless aneurysm pressure sensor in a canine model: Will surveillance CT scan following EVAR become obsolete? J Endovasc Ther 10(Suppl):1\u201332","journal-title":"J Endovasc Ther"},{"key":"9245_CR20","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1016\/j.jvs.2006.08.031","volume":"44","author":"RA Chaer","year":"2006","unstructured":"Chaer RA, Trocciola S, DeRubertis B, et\u00a0al. (2006) Evaluation of the accuracy of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak and correlation with histologic analysis. J Vasc Surg 44:1306\u20131313","journal-title":"J Vasc Surg"},{"key":"9245_CR21","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1583\/04-1229.1","volume":"11","author":"R Milner","year":"2004","unstructured":"Milner R, Ruurda JP, Blankensteijn JD (2004) Durability and validity of a remote, miniaturized pressure sensor in an animal model of abdominal aortic aneurysm. J Endovasc Ther 11:372\u2013377","journal-title":"J Endovasc Ther"},{"key":"9245_CR22","doi-asserted-by":"crossref","first-page":"99","DOI":"10.2310\/6670.2004.20755","volume":"12","author":"R Milner","year":"2004","unstructured":"Milner R, Verhagen HJ, Prinssen M, et\u00a0al. (2004) Noninvasive intrasac pressure measurement and the influence of type 2 and type 3 endoleaks in an animal model of abdominal aortic aneurysm. Vascular 12:99\u2013105","journal-title":"Vascular"},{"key":"9245_CR23","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jvs.2005.09.039","volume":"43","author":"SH Ellozy","year":"2006","unstructured":"Ellozy SH, Carroccio A, Lookstein RA, et\u00a0al. (2006) Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurement. J Vasc Surg 43:2\u20137","journal-title":"J Vasc Surg"},{"key":"9245_CR24","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.jvs.2004.06.027","volume":"40","author":"SH Ellozy","year":"2004","unstructured":"Ellozy SH, Carroccio A, Lookstein RA, et\u00a0al. (2004) First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg 40:405\u2013412","journal-title":"J Vasc Surg"},{"key":"9245_CR25","doi-asserted-by":"crossref","unstructured":"Schlierf R, G\u00f6rtz M, Schmitz-Rode T, et\u00a0al. (2005) Pressure sensor to control the treatment of abdominal aorta aneurisms. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Digest of Technical Papers, TRANSDUCERS \u201805:1656\u20131659","DOI":"10.1109\/SENSOR.2005.1497407"},{"key":"9245_CR26","doi-asserted-by":"crossref","first-page":"2589","DOI":"10.1007\/s00330-007-0583-4","volume":"17","author":"F Springer","year":"2007","unstructured":"Springer F, Schlierf R, Pfeffer JG, et\u00a0al. (2007) Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: An in\u00a0vitro study. Eur Radiol 17:2589\u20132597","journal-title":"Eur Radiol"},{"key":"9245_CR27","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1053\/j.semvascsurg.2006.03.002","volume":"19","author":"R Milner","year":"2006","unstructured":"Milner R, Kasirajan K, Chaikof EL (2006) Future of endograft surveillance. Semin Vasc Surg 19:75\u201382","journal-title":"Semin Vasc Surg"},{"key":"9245_CR28","doi-asserted-by":"crossref","first-page":"264","DOI":"10.2310\/6670.2006.00048","volume":"14","author":"L Carnero","year":"2006","unstructured":"Carnero L, Milner R (2006) Aneurysm sac pressure measurement with a pressure sensor in endovascular aortic aneurysm repair. Vascular 14:264\u2013269","journal-title":"Vascular"},{"key":"9245_CR29","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1097\/01.RVI.0000217944.36738.02","volume":"17","author":"Z Sun","year":"2006","unstructured":"Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 17:759\u2013764","journal-title":"J Vasc Interv Radiol"},{"key":"9245_CR30","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1583\/05-1575MR.1","volume":"12","author":"AF AbuRahma","year":"2005","unstructured":"AbuRahma AF, Welch CA, Mullins BB, et\u00a0al. (2005) Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther 12:568\u2013573","journal-title":"J Endovasc Ther"},{"key":"9245_CR31","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1583\/04-1479R.1","volume":"12","author":"R Ashoke","year":"2005","unstructured":"Ashoke R, Brown LC, Rodway A, et\u00a0al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review. J Endovasc Ther 12:297\u2013305","journal-title":"J Endovasc Ther"},{"key":"9245_CR32","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.jvs.2005.09.045","volume":"43","author":"EA Henao","year":"2006","unstructured":"Henao EA, Hodge MD, Felkai DD, et\u00a0al. (2006) Contrast-enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: Improved efficacy using a continuous infusion technique. J Vasc Surg 43:259\u2013264; discussion 264","journal-title":"J Vasc Surg"},{"key":"9245_CR33","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1177\/153857440303700302","volume":"37","author":"PJ Bendick","year":"2003","unstructured":"Bendick PJ, Zelenock GB, Bove PG, et\u00a0al. (2003) Duplex ultrasound imaging with an ultrasound contrast agent: The economic alternative to CT angiography for aortic stent graft surveillance. Vasc Endovascular Surg 37:165\u2013170","journal-title":"Vasc Endovascular Surg"},{"key":"9245_CR34","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.2214\/AJR.04.0729","volume":"185","author":"MB Pitton","year":"2005","unstructured":"Pitton MB, Schweitzer H, Herber S, et\u00a0al. (2005) MRI versus helical CT for endoleak detection after endovascular aneurysm repair. AJR Am J Roentgenol 185:1275\u20131281","journal-title":"AJR Am J Roentgenol"},{"key":"9245_CR35","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.ejvs.2006.02.011","volume":"32","author":"MJ Laan van der","year":"2006","unstructured":"van der Laan MJ, Bartels LW, Viergever MA, et\u00a0al. (2006) Computed tomography versus magnetic resonance imaging of endoleaks after EVAR. Eur J Vasc Endovasc Surg 32:361\u2013365","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"9245_CR36","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1055\/s-2002-34624","volume":"174","author":"SC Kr\u00e4mer","year":"2002","unstructured":"Kr\u00e4mer SC, Gorich J, Pamler R, et\u00a0al. (2002) The contribution of MRI to the detection of endovascular aneurysm repair. Rofo 174:1285\u20131288","journal-title":"Rofo"},{"key":"9245_CR37","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.jvir.2007.01.025","volume":"18","author":"RH Chewning","year":"2007","unstructured":"Chewning RH, Murphy KJ (2007) Gadolinium-based Contrast Media and the Development of Nephrogenic Systemic Fibrosis in Patients with Renal Insufficiency. J Vasc Interv Radiol 18:331\u2013333","journal-title":"J Vasc Interv Radiol"},{"key":"9245_CR38","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.jaad.2006.10.047","volume":"56","author":"WA High","year":"2007","unstructured":"High WA, Ayers RA, Chandler J, et\u00a0al. (2007) Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis. J Am Acad Dermatol 56:21\u201326","journal-title":"J Am Acad Dermatol"},{"key":"9245_CR39","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/01.rli.0000253505.88945.d5","volume":"42","author":"A Khurana","year":"2007","unstructured":"Khurana A, Runge VM, Narayanan M, et\u00a0al. (2007) Nephrogenic systemic fibrosis: a review of 6 cases temporally related to gadodiamide injection (Omniscan). Invest Radiol 42:139\u2013145","journal-title":"Invest Radiol"},{"key":"9245_CR40","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1002\/jmri.20983","volume":"25","author":"M Pedersen","year":"2007","unstructured":"Pedersen M (2007) Safety update on the possible causal relationship between gadolinium-containing MRI agents and nephrogenic systemic fibrosis. J Magn Reson Imaging 25:881\u2013883","journal-title":"J Magn Reson Imaging"},{"key":"9245_CR41","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1148\/radiol.2431062144","volume":"243","author":"EA Sadowski","year":"2007","unstructured":"Sadowski EA, Bennett LK, Chan MR, et\u00a0al. (2007) Nephrogenic systemic fibrosis: Risk factors and incidence estimation. Radiology 243:148\u2013157","journal-title":"Radiology"},{"key":"9245_CR42","doi-asserted-by":"crossref","unstructured":"Fonseca MA, Allen M, Kroh J, et\u00a0al. (2006) Flexible wireless passive pressure sensors for biomedical applications. Solid-State Sensors, Actuators, and Microsystems Workshop, Hilton Head Island, South Carolina, June 4\u20138, pp 37\u201342","DOI":"10.31438\/trf.hh2006.9"}],"container-title":["CardioVascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00270-007-9245-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00270-007-9245-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00270-007-9245-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,15]],"date-time":"2023-05-15T09:00:08Z","timestamp":1684141208000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00270-007-9245-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,12,18]]},"references-count":42,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,5]]}},"alternative-id":["9245"],"URL":"https:\/\/doi.org\/10.1007\/s00270-007-9245-9","relation":{},"ISSN":["0174-1551","1432-086X"],"issn-type":[{"value":"0174-1551","type":"print"},{"value":"1432-086X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,12,18]]}}}