{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T11:06:12Z","timestamp":1771931172096,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2019,1,16]],"date-time":"2019-01-16T00:00:00Z","timestamp":1547596800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Intervent Radiol"],"published-print":{"date-parts":[[2019,5]]},"DOI":"10.1007\/s00270-019-02163-3","type":"journal-article","created":{"date-parts":[[2019,1,16]],"date-time":"2019-01-16T15:50:29Z","timestamp":1547653829000},"page":"712-719","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose"],"prefix":"10.1007","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7741-7267","authenticated-orcid":false,"given":"Davide","family":"Fior","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Vacirca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davide","family":"Leni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio","family":"Pagni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davide","family":"Ippolito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luca","family":"Riva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandro","family":"Sironi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rocco","family":"Corso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,1,16]]},"reference":[{"key":"2163_CR1","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1159\/000093369","volume":"73","author":"FJF Herth","year":"2016","unstructured":"Herth FJF, Eberhardt R, Ernst A. The future of bronchoscopy in diagnosing, staging and treatment of lung cancer. Respiration. 2016;73:399\u2013409.","journal-title":"Respiration"},{"key":"2163_CR2","doi-asserted-by":"publisher","first-page":"e93S","DOI":"10.1378\/chest.12-2351","volume":"143","author":"MK Gould","year":"2013","unstructured":"Gould MK, Donington J, Lynch WR, et al. Evaluation of individuals with pulmonary nodules: When is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143:e93S\u2013120S.","journal-title":"Chest"},{"issue":"1","key":"2163_CR3","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1148\/radiol.2391050343","volume":"239","author":"HT Winer-Muram","year":"2006","unstructured":"Winer-Muram HT. The solitary pulmonary nodule. Radiology. 2006;239(1):34\u201349.","journal-title":"Radiology"},{"issue":"6","key":"2163_CR4","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1007\/s00330-006-0152-2","volume":"16","author":"SL Heck","year":"2006","unstructured":"Heck SL, Blom P. Berstad A accuracy and complications in computed tomography fluoroscopy guided needle biopsies of lung masses. Eur Radiol. 2006;16(6):1387\u201392.","journal-title":"Eur Radiol"},{"issue":"6","key":"2163_CR5","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1378\/chest.09-0370","volume":"136","author":"T Hiraki","year":"2009","unstructured":"Hiraki T, Mimura H, Gobara H, et al. CT floroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest. 2009;136(6):1612\u20137.","journal-title":"Chest"},{"issue":"2","key":"2163_CR6","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1148\/radiol.2291020499","volume":"229","author":"PR Geraghty","year":"2003","unstructured":"Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology. 2003;229(2):475\u201381.","journal-title":"Radiology"},{"issue":"2","key":"2163_CR7","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1148\/radiol.2372041323","volume":"237","author":"SK Carlson","year":"2005","unstructured":"Carlson SK, Felmlee JP, Bender CE, et al. CT floroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology. 2005;237(2):701\u20138.","journal-title":"Radiology"},{"issue":"2","key":"2163_CR8","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/S0033-8389(05)70162-7","volume":"38","author":"DF Yankelevitz","year":"2000","unstructured":"Yankelevitz DF, Vazquez M, Henschke CI. Special techniques in transthoracic needle biopsy of pulmonary nodules. Radiol Clin N Am. 2000;38(2):267\u201379.","journal-title":"Radiol Clin N Am"},{"issue":"8","key":"2163_CR9","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1007\/s00270-017-1642-0","volume":"40","author":"R Sato","year":"2017","unstructured":"Sato R, Aramaki T, Yoza K, et al. \u201cDirect MPR\u201d: a useful tool for oblique CT fluoroscopy-assisted puncture. Cardiovasc Intervent Radiol. 2017;40(8):1261\u20136.","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"7","key":"2163_CR10","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/S0009-9260(96)80191-7","volume":"51","author":"H Arakawa","year":"1996","unstructured":"Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol. 1996;51(7):503\u20136.","journal-title":"Clin Radiol"},{"issue":"3","key":"2163_CR11","doi-asserted-by":"publisher","first-page":"661","DOI":"10.2214\/ajr.169.3.9275873","volume":"169","author":"PM Boiselle","year":"1997","unstructured":"Boiselle PM, Shepard JA, Mark EJ, et al. Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospective assessment. AJR Am J Roentgenol. 1997;169(3):661\u20136.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2163_CR12","doi-asserted-by":"publisher","first-page":"53","DOI":"10.2214\/ajr.165.1.7785631","volume":"165","author":"LB Haramati","year":"1995","unstructured":"Haramati LB. CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol. 1995;165(1):53\u20135.","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2163_CR13","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1148\/radiology.198.3.8628859","volume":"198","author":"JS Klein","year":"1996","unstructured":"Klein JS, Salomon G, Stewart EA. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology. 1996;198(3):715\u201320.","journal-title":"Radiology"},{"issue":"5","key":"2163_CR14","doi-asserted-by":"publisher","first-page":"903","DOI":"10.2214\/ajr.151.5.903","volume":"151","author":"CH Goralnik","year":"1988","unstructured":"Goralnik CH, O\u2019Connell DM, el Yousef SJ, Haaga JR. CT-guided cutting-needle biopsies of selected chest lesions. AJR Am J Roentgenol. 1988;151(5):903\u20137.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2163_CR15","doi-asserted-by":"publisher","first-page":"19","DOI":"10.2478\/v10019-012-0004-4","volume":"46","author":"S Beslic","year":"2012","unstructured":"Beslic S, Zukic F, Milisic S. Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy. Radiol Oncol. 2012;46(1):19\u201322.","journal-title":"Radiol Oncol"},{"issue":"5","key":"2163_CR16","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","volume":"14","author":"K-M Yeow","year":"2003","unstructured":"Yeow K-M, Tsay P-K, Cheung Y-C, Lui K-W, Pan K-T, Chou AS-B. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol. 2003;14(5):581\u20138.","journal-title":"J Vasc Interv Radiol"},{"issue":"1","key":"2163_CR17","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1148\/radiol.13131265","volume":"271","author":"SM Lee","year":"2014","unstructured":"Lee SM, Park CM, Lee KH, Bahn YE, Kim JI, Goo JM. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology. 2014;271(1):291\u2013300.","journal-title":"Radiology"},{"key":"2163_CR18","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1093\/rpd\/ncr464","volume":"151","author":"S Strocchi","year":"2012","unstructured":"Strocchi S, Colli V, Conte L, et al. Multidector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses. Radiat Prot Dosim. 2012;151:162\u20135.","journal-title":"Radiat Prot Dosim"},{"key":"2163_CR19","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1007\/s00270-005-0287-6","volume":"29","author":"S Hirota","year":"2006","unstructured":"Hirota S, Nakao N, Yamamoto S, et al. Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures. Cardiovasc Intervent Radiol. 2006;29:1034\u20138.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2163_CR20","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1007\/s00256-010-0959-4","volume":"40","author":"SE Kang","year":"2011","unstructured":"Kang SE, Lee JW, Kim JH, et al. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome. Skeletal Radiol. 2011;40:453\u201360.","journal-title":"Skeletal Radiol"},{"key":"2163_CR21","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1007\/s11547-012-0788-1","volume":"117","author":"G Carrafiello","year":"2012","unstructured":"Carrafiello G, Fontana F, Mangini M, et al. Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med. 2012;117:1386\u201397.","journal-title":"Radiol Med"},{"key":"2163_CR22","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1258\/ar.2011.110187","volume":"52","author":"H Higashihara","year":"2011","unstructured":"Higashihara H, Osuga K, Azuma T, et al. Detection of pulmonary nodules by C-arm CT using a phantom lung: comparison with CT. Acta Radiol. 2011;52:964\u20138.","journal-title":"Acta Radiol"},{"issue":"11","key":"2163_CR23","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1007\/s11547-014-0406-z","volume":"119","author":"C Floridi","year":"2014","unstructured":"Floridi C, Muollo A, Fontana F, et al. C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules. Radiol Med. 2014;119(11):802\u20137.","journal-title":"Radiol Med"},{"issue":"4","key":"2163_CR24","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/j.tranon.2015.04.006","volume":"8","author":"YC Cheng","year":"2015","unstructured":"Cheng YC, Tsai SH, Cheng, et al. Percutaneous transthoracic lung biopsy: comparison between C-arm cone-beam CT and conventional CT guidance. Transl Oncol. 2015;8(4):258\u201364.","journal-title":"Transl Oncol"},{"issue":"6","key":"2163_CR25","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.2214\/ajr.180.6.1801665","volume":"180","author":"Y Ohno","year":"2003","unstructured":"Ohno Y, Hatabu H, Takenaka D, et al. CT-guided transthoracic needle aspiration biopsy of small (, or\u2009=\u200920\u00a0mm) solitary pulmonary nodules. AJR Am J Roentgenol. 2003;180(6):1665\u20139.","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2163_CR26","doi-asserted-by":"publisher","first-page":"809","DOI":"10.2214\/AJR.09.3224","volume":"194","author":"T Hiraki","year":"2010","unstructured":"Hiraki T, Mimura H, Gobara H, et al. Incidence of and risk factors for pneumothorax and chest tube placement after CT floroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period. AJR Am J Roentgenol. 2010;194(3):809\u201314.","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2163_CR27","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1378\/chest.126.3.748","volume":"126","author":"KM Yeow","year":"2004","unstructured":"Yeow KM, Su IH, Pan KT, et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest. 2004;126(3):748\u201354.","journal-title":"Chest"},{"issue":"2","key":"2163_CR28","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1148\/radiology.198.2.8596834","volume":"198","author":"EA Kazerooni","year":"1996","unstructured":"Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology. 1996;198(2):371\u20135.","journal-title":"Radiology"},{"key":"2163_CR29","doi-asserted-by":"publisher","first-page":"322","DOI":"10.2214\/AJR.11.7576","volume":"199","author":"JW Choi","year":"2012","unstructured":"Choi JW, Park CM, Goo JM, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (\u2264\u200920\u00a0mm) lung nodules: diagnostic accuracy and complications in 161 patients. Am J Roentgenol. 2012;199:322\u201330.","journal-title":"Am J Roentgenol"},{"key":"2163_CR30","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1007\/s00330-010-1936-y","volume":"21","author":"GR Kim","year":"2011","unstructured":"Kim GR, Hur J, Lee SM, et al. CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol. 2011;21:232\u20139.","journal-title":"Eur Radiol"}],"container-title":["CardioVascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00270-019-02163-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00270-019-02163-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00270-019-02163-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,1,15]],"date-time":"2020-01-15T19:14:22Z","timestamp":1579115662000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00270-019-02163-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,16]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["2163"],"URL":"https:\/\/doi.org\/10.1007\/s00270-019-02163-3","relation":{},"ISSN":["0174-1551","1432-086X"],"issn-type":[{"value":"0174-1551","type":"print"},{"value":"1432-086X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1,16]]},"assertion":[{"value":"20 August 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed Consent"}}]}}