{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T18:00:27Z","timestamp":1790186427154,"version":"4.1.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Intervent Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the feasibility, usability, and perceived workload of the AZURION-AR augmented reality (AR) medical device during routine interventional radiology procedures in a real-world clinical setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>This prospective, single-center, single-arm feasibility study included six interventional radiologists performing 34 AR-assisted vascular and non-vascular procedures. The AZURION-AR system projected virtual monitor and touchscreen interfaces within the operator\u2019s visual field. Post-procedural structured interviews and standardized 5-point Likert questionnaires assessed usability (System Usability Scale, SUS; 1\u20135 per item, max score: 100), workload (NASA Task Load Index, NASA-TLX; 0\u201321 per domain), and image quality (1\u20135 scale).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Continuous head-mounted display use throughout the procedure occurred in 20 cases (58%); mean wearing time was 40\u00a0min [5\u2013140\u00a0min] versus a mean procedure duration of 59\u00a0min [20\u2013240\u00a0min]. Mean SUS score was 64.5 \u00b1 11.1, indicating moderate usability with considerable inter-operator variability. Mean NASA-TLX score was 7.6 \u00b1 1.4, reflecting acceptable workload. Mean image quality score was 3.5 \u00b1 0.6, with substantial variability across interventions. Scores tended to be lower in vascular and complex drainage procedures, reflecting increased effort and frustration, reduced anatomical detail, limited spatial resolution, and technical issues such as battery depletion and signal lag.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The AZURION-AR medical device proved feasible for use during routine interventional radiology offering unanimously rated perceived ergonomic advantages. Although usability was moderate, limitations in image resolution, technical reliability, and battery life require further refinement before reliable routine clinical implementation can be achieved, particularly for procedures requiring high spatial resolution and detailed\u00a0anatomical assessment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00270-026-04615-z","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T17:01:33Z","timestamp":1790182893000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility and Usability of Head-Mounted Display Augmented Reality During Routine Radiological Interventions: The Prospective AZURION-AR Study"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-1475-5175","authenticated-orcid":false,"given":"Pietro","family":"Zappala","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. L. J.","family":"Smits","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. W. K.","family":"Vos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Goossen-Nachtigall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. A. F.","family":"van den Heuvel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. C.","family":"Jacobs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. P.","family":"van Lienden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"van Leersum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"van Strijen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"issue":"2","key":"4615_CR1","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.jvir.2020.11.001","volume":"32","author":"MG Knuttinen","year":"2021","unstructured":"Knuttinen MG, Zurcher KS, Wallace A, Doe C, Naidu SG, Money SR, et al. Ergonomics in IR. J Vasc Interv Radiol. 2021;32(2):235\u201341. https:\/\/doi.org\/10.1016\/j.jvir.2020.11.001.","journal-title":"J Vasc Interv Radiol"},{"issue":"5","key":"4615_CR2","doi-asserted-by":"publisher","DOI":"10.3390\/medicina57050500","volume":"57","author":"FH Cornelis","year":"2021","unstructured":"Cornelis FH, Razakamanantsoa L, Ben Ammar M, Lehrer R, Haffaf I, El-Mouhadi S, et al. Ergonomics in interventional radiology: awareness is mandatory. Medicina (Kaunas). 2021;57(5):500. https:\/\/doi.org\/10.3390\/medicina57050500.","journal-title":"Medicina (Kaunas)"},{"issue":"6","key":"4615_CR3","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s11547-025-02001-2","volume":"130","author":"M Tortora","year":"2025","unstructured":"Tortora M, Luppi A, Pacchiano F, Marisei M, Grassi F, Werner H, et al. Current applications and future perspectives of extended reality in radiology. Radiol Med. 2025;130(6):905\u201320. https:\/\/doi.org\/10.1007\/s11547-025-02001-2.","journal-title":"Radiol Med"},{"issue":"4","key":"4615_CR4","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1914","volume":"14","author":"JW Yoon","year":"2018","unstructured":"Yoon JW, Chen RE, Kim EJ, Akinduro OO, Kerezoudis P, Han PK, et al. Augmented reality for the surgeon: systematic review. Int J Med Robot. 2018;14(4):e1914. https:\/\/doi.org\/10.1002\/rcs.1914.","journal-title":"Int J Med Robot"},{"issue":"4","key":"4615_CR5","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1590\/1516-3180.2021.0606.R2.27122021","volume":"140","author":"AYP Gelmini","year":"2022","unstructured":"Gelmini AYP, Duarte ML, Silva MOD, Guimar\u00e3es Junior JB, Santos LRD. Augmented reality in interventional radiology education: a systematic review of randomized controlled trials. Sao Paulo Med J. 2022;140(4):604\u201314. https:\/\/doi.org\/10.1590\/1516-3180.2021.0606.R2.27122021.","journal-title":"Sao Paulo Med J"},{"issue":"2","key":"4615_CR6","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.54907","volume":"16","author":"J Baker","year":"2024","unstructured":"Baker J, Antypas A, Aggarwal P, Elliott C, Baxter R, Singh S, et al. Augmented reality in interventional radiology: transforming training paradigms. Cureus. 2024;16(2):e54907. https:\/\/doi.org\/10.7759\/cureus.54907.","journal-title":"Cureus"},{"key":"4615_CR7","doi-asserted-by":"publisher","DOI":"10.1177\/17562872241297554","volume":"16","author":"OS T\u0103taru","year":"2024","unstructured":"T\u0103taru OS, Ferro M, Marchioni M, Veccia A, Coman O, Lasorsa F, et al. HoloLens\u00ae platform for healthcare professionals simulation training, teaching, and its urological applications: an up-to-date review. Ther Adv Urol. 2024;16:17562872241297554. https:\/\/doi.org\/10.1177\/17562872241297554.","journal-title":"Ther Adv Urol"},{"issue":"4","key":"4615_CR8","doi-asserted-by":"publisher","first-page":"2927","DOI":"10.1007\/s00330-022-09220-5","volume":"33","author":"NA Farshad-Amacker","year":"2023","unstructured":"Farshad-Amacker NA, Kubik-Huch RA, Kolling C, Leo C, Goldhahn J. Learning how to perform ultrasound-guided interventions with and without augmented reality visualization: a randomized study. Eur Radiol. 2023;33(4):2927\u201334. https:\/\/doi.org\/10.1007\/s00330-022-09220-5.","journal-title":"Eur Radiol"},{"issue":"8","key":"4615_CR9","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1007\/s00270-022-03195-y","volume":"45","author":"V Van den Bosch","year":"2022","unstructured":"Van den Bosch V, Salim HS, Chen NZ, Stroosma O, Bruners P, Kuhl CK, et al. Augmented reality-assisted CT-guided puncture: a phantom study. Cardiovasc Interv Radiol. 2022;45(8):1173\u20137. https:\/\/doi.org\/10.1007\/s00270-022-03195-y.","journal-title":"Cardiovasc Interv Radiol"},{"issue":"6","key":"4615_CR10","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1049\/htl.2019.0062","volume":"6","author":"F Heinrich","year":"2019","unstructured":"Heinrich F, Schwenderling L, Becker M, Skalej M, Hansen C. HoloInjection: augmented reality support for CT-guided spinal needle injections. Healthc Technol Lett. 2019;6(6):165\u201371. https:\/\/doi.org\/10.1049\/htl.2019.0062.","journal-title":"Healthc Technol Lett"},{"issue":"5","key":"4615_CR11","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1007\/s11548-020-02142-x","volume":"15","author":"Y Mu","year":"2020","unstructured":"Mu Y, Hocking D, Wang ZT, Garvin GJ, Eagleson R, Peters TM. Augmented reality simulator for ultrasound-guided percutaneous renal access. Int J Comput Assist Radiol Surg. 2020;15(5):749\u201357. https:\/\/doi.org\/10.1007\/s11548-020-02142-x.","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"4615_CR12","doi-asserted-by":"publisher","DOI":"10.1186\/s41747-017-0033-2","volume":"2","author":"P Pratt","year":"2018","unstructured":"Pratt P, Ives M, Lawton G, Simmons J, Radev N, Spyropoulou L, et al. Through the HoloLens\u2122 looking glass: augmented reality for extremity reconstruction surgery using 3D vascular models with perforating vessels. Eur Radiol Exp. 2018;2(1):2. https:\/\/doi.org\/10.1186\/s41747-017-0033-2.","journal-title":"Eur Radiol Exp"},{"key":"4615_CR13","doi-asserted-by":"publisher","first-page":"129281D","DOI":"10.1117\/12.3008663","volume":"12928","author":"R Fraser","year":"2024","unstructured":"Fraser R, Bettati P, Young J, Rathgeb A, Sirsi S, Fei B. A fast and interactive augmented reality system for PET\/CT-guided intervention of neuroblastoma. Proc SPIE Int Soc Opt Eng. 2024;12928:129281D. https:\/\/doi.org\/10.1117\/12.3008663. (Epub 2024 Mar 29).","journal-title":"Proc SPIE Int Soc Opt Eng"},{"key":"4615_CR14","doi-asserted-by":"publisher","first-page":"29","DOI":"10.5555\/2817912.2817913","volume":"8","author":"J Brooke","year":"2013","unstructured":"Brooke J. SUS: a retrospective. J Usability Stud. 2013;8:29\u201340. https:\/\/doi.org\/10.5555\/2817912.2817913.","journal-title":"J Usability Stud"},{"key":"4615_CR15","doi-asserted-by":"publisher","unstructured":"Brooke J. SUS: a quick and dirty usability scale. In: Usability evaluation in industry. Taylor & Francis; London. 1996; 189\u2013194. https:\/\/doi.org\/10.1201\/9781498710411-35.","DOI":"10.1201\/9781498710411-35"},{"issue":"3","key":"4615_CR16","doi-asserted-by":"publisher","first-page":"114","DOI":"10.5555\/2835587.2835589","volume":"4","author":"A Bangor","year":"2009","unstructured":"Bangor A, Kortum P, Miller J. Determining what individual SUS scores mean: adding an adjective rating scale. J Usability Stud. 2009;4(3):114\u201323. https:\/\/doi.org\/10.5555\/2835587.2835589.","journal-title":"J Usability Stud"},{"issue":"3","key":"4615_CR17","doi-asserted-by":"publisher","first-page":"158","DOI":"10.5555\/3294033.3294037","volume":"13","author":"JR Lewis","year":"2018","unstructured":"Lewis JR, Sauro J. Item benchmarks for the system usability scale. J Usability Stud. 2018;13(3):158\u201367. https:\/\/doi.org\/10.5555\/3294033.3294037.","journal-title":"J Usability Stud"},{"key":"4615_CR18","volume-title":"A practical guide to the system usability scale: background, benchmarks and best practices","author":"J Sauro","year":"2011","unstructured":"Sauro J. A practical guide to the system usability scale: background, benchmarks and best practices. Denver, CO: Measuring Usability LLC; 2011."},{"key":"4615_CR19","unstructured":"Hart SG. NASA Task Load Index (TLX). Paper and pencil package. Version 1.0. 1986."},{"key":"4615_CR20","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1177\/154193120605000909","volume":"50","author":"SG Hart","year":"2006","unstructured":"Hart SG. NASA-Task Load Index (NASA-TLX): 20 years later. Proc Hum Factors Ergon Soc Annu Meet. 2006;50:904\u20138. https:\/\/doi.org\/10.1177\/154193120605000909.","journal-title":"Proc Hum Factors Ergon Soc Annu Meet."},{"key":"4615_CR21","doi-asserted-by":"publisher","first-page":"1727","DOI":"10.1177\/1541931215591373","volume":"59","author":"RA Grier","year":"2015","unstructured":"Grier RA. How high is high? A meta-analysis of NASA-TLX global workload scores. Proc Hum Factors Ergon Soc Annu Meet. 2015;59:1727\u201331. https:\/\/doi.org\/10.1177\/1541931215591373.","journal-title":"Proc Hum Factors Ergon Soc Annu Meet."},{"issue":"5","key":"4615_CR22","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.3390\/cancers14051312","volume":"14","author":"M o Solbiati","year":"2022","unstructured":"o Solbiati M, Ierace T, Muglia R, Pedicini V, Iezzi R, Passera KM, et al. Thermal ablation of liver tumors guided by augmented reality: an initial clinical experience. Cancers (Basel). 2022;14(5):1312. https:\/\/doi.org\/10.3390\/cancers14051312.","journal-title":"Cancers (Basel)."},{"issue":"1","key":"4615_CR23","doi-asserted-by":"publisher","DOI":"10.1186\/s41747-023-00353-w","volume":"7","author":"D Albano","year":"2023","unstructured":"Albano D, Messina C, Gitto S, Chianca V, Sconfienza LM. Bone biopsies guided by augmented reality: a pilot study. Eur Radiol Exp. 2023;7(1):40. https:\/\/doi.org\/10.1186\/s41747-023-00353-w.","journal-title":"Eur Radiol Exp"},{"issue":"3","key":"4615_CR24","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1007\/s00270-025-04249-7","volume":"49","author":"T Borde","year":"2026","unstructured":"Borde T, Xu S, Saccenti L, Kassin MT, Varble NA, Wood BJ. Dual-camera augmented reality-based navigation system for precision CT-guided biopsy and ablation. Cardiovasc Interv Radiol. 2026;49(3):671\u20138. https:\/\/doi.org\/10.1007\/s00270-025-04249-7.","journal-title":"Cardiovasc Interv Radiol"},{"issue":"7","key":"4615_CR25","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1007\/s00270-024-03727-8","volume":"47","author":"L Saccenti","year":"2024","unstructured":"Saccenti L, Bessy H, Ben Jedidia B, Longere B, Tortolano L, Derbel H, et al. Performance comparison of augmented reality versus ultrasound guidance for puncture: a phantom study. Cardiovasc Interv Radiol. 2024;47(7):993\u20139. https:\/\/doi.org\/10.1007\/s00270-024-03727-8.","journal-title":"Cardiovasc Interv Radiol"}],"container-title":["CardioVascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00270-026-04615-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00270-026-04615-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00270-026-04615-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T17:01:35Z","timestamp":1790182895000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00270-026-04615-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":25,"alternative-id":["4615"],"URL":"https:\/\/doi.org\/10.1007\/s00270-026-04615-z","relation":{},"ISSN":["1432-086X"],"issn-type":[{"value":"1432-086X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]},"assertion":[{"value":"13 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}