{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T14:18:40Z","timestamp":1770214720353,"version":"3.49.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2000,3,1]],"date-time":"2000-03-01T00:00:00Z","timestamp":951868800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cardiovasc Intervent Radiol"],"published-print":{"date-parts":[[2000,3]]},"DOI":"10.1007\/s002709910019","type":"journal-article","created":{"date-parts":[[2002,7,25]],"date-time":"2002-07-25T07:09:43Z","timestamp":1027580983000},"page":"87-90","source":"Crossref","is-referenced-by-count":6,"title":["Coil occlusion of the paient ductus arteriosus: lessons learned"],"prefix":"10.1007","volume":"23","author":[{"given":"Shubhayan","family":"Sanatani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James E.","family":"Potts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angela","family":"Ryan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George G. S.","family":"Sandor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Derek G.","family":"Human","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. A. Gordon","family":"Culham","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"230200087_CR1","doi-asserted-by":"crossref","unstructured":"Lloyd TR, Beekman RH (1994) Clinically silent patent ductus arteriosus, (letter) Am Heart J 127(6):P1664","DOI":"10.1016\/0002-8703(94)90415-4"},{"issue":"4","key":"230200087_CR2","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.1016\/0002-8703(93)90144-X","volume":"125","author":"DT Balzer","year":"1993","unstructured":"Balzer DT, Spray TL, McMullin D, Cottingham W, Canter CE (1993) Endarteritis associated with a clinically silent patent ductus arteriosus. Am Heart J 125(4): 1192\u20131193","journal-title":"Am Heart J"},{"key":"230200087_CR3","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/S0022-3476(97)70209-9","volume":"130","author":"A Rothman","year":"1997","unstructured":"Rothman A, Lucas VW, Sklansky MS, Cocalis MW, Kashani IA (1997) Percutaneous coil occlusion of patent ductus arteriosus. Pediatr 130: 447\u2013454","journal-title":"Pediatr"},{"key":"230200087_CR4","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/s002469900248","volume":"19","author":"D Shim","year":"1998","unstructured":"Shim D, Beekman RHI (1998) Transcatheter management of patent ductus arteriosus. Ped Cardiol 19:67\u201371","journal-title":"Ped Cardiol"},{"key":"230200087_CR5","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1002\/(SICI)1097-0304(199708)41:4<386::AID-CCD7>3.0.CO;2-1","volume":"41","author":"T Podnar","year":"1997","unstructured":"Podnar T, Masura J (1997) Percutaneous closure of patent ductus arteriosus using special screwing detachable coils. Cath Cardiovasc Diagn 41:386\u2013391","journal-title":"Cath Cardiovasc Diagn"},{"key":"230200087_CR6","doi-asserted-by":"crossref","first-page":"1856","DOI":"10.1016\/S0735-1097(97)00382-3","volume":"30","author":"CY Owada","year":"1997","unstructured":"Owada CY, Teitel DF, Moore P (1997) Evaluation of Gianturco coils for closure of large (>3.5 mm) patent ductus arteriosus. J Am Coll Cardiol 30:1856\u20131862","journal-title":"J Am Coll Cardiol"},{"key":"230200087_CR7","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1161\/01.CIR.88.4.1412","volume":"88","author":"TR Lloyd","year":"1993","unstructured":"Lloyd TR, Fedderly R, Mendelsohn A, Sandhu SK, Beekman RH (1993) Transcatheter occlusion of patent ductus arteriosus with Gianturco coils. Circulation 88:1412\u20131420","journal-title":"Circulation"},{"key":"230200087_CR8","first-page":"703","volume":"96","author":"DG Human","year":"1995","unstructured":"Human DG, Lucas ML, Gniewek A, Hanna BD (1995) Technology assessment of nonsurgical closure of patent ductus arteriosus: An evaluation of the clinical effectiveness and costs of a new medical device. Pediatr 96:703\u2013706","journal-title":"Pediatr"},{"key":"230200087_CR9","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1016\/S0002-9149(97)89219-3","volume":"77","author":"R Fedderly","year":"1996","unstructured":"Fedderly R, Beekman RHI, Mosca RS, Bove EL, Lloyd TR (1996) Comparison of hospital charges for closure of patent ductus arteriosus by surgery and transcatheter coil occlusion. Am J Cardiol 77:776\u2013779","journal-title":"Am J Cardiol"},{"issue":"2","key":"230200087_CR10","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S0033-8389(22)01768-7","volume":"9","author":"W Porstmann","year":"1971","unstructured":"Porstmann W, Wierny L, Warnke H, Gertsberger G, Romaniuk PA (1971) Catheter closure of patent ductus arteriosus: 62 cases treated without thoracotomy. Radiol Clin North Am 9(2):203\u2013218","journal-title":"Radiol Clin North Am"},{"key":"230200087_CR11","doi-asserted-by":"crossref","first-page":"428","DOI":"10.2214\/ajr.124.3.428","volume":"24","author":"C Gianturco","year":"1975","unstructured":"Gianturco C, Anderson JH, Wallace S (1975) Mechanical devices for arterial occlusion. AJR 24:428\u2013435","journal-title":"AJR"},{"key":"230200087_CR12","unstructured":"Radtke WAK (1997) Comparison of the efficacy and safety of the Rashkind occluder versus Gianturco coils for occlusion of the patent ductus arteriosus, (abstract) Proceedings from the Second World Congress of Pediatric Cardiology and Cardiac Surgery, p116"},{"key":"230200087_CR13","unstructured":"Samion H, Alwi M, Latiff H, Kandavello G, Lim MK, Zambahari R (1997) Transcatheter occlusion of patent ductus arteriosus (PDA): Comparison of outcome between Rashkind umbrella device and Gianturco coil, (abstract) Proceedings from the Second World Congress of Pediatric Cardiology and Cardiac Surgery, p116."},{"key":"230200087_CR14","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/0002-9149(91)90911-4","volume":"67","author":"KE Sorenson","year":"1991","unstructured":"Sorenson KE, Kristensen BO, Hansen OK (1991) Frequency of occurrence of residual ductal flow after surgical ligation by color-flow mapping. Am J Cardiol 67:653\u2013654","journal-title":"Am J Cardiol"},{"key":"230200087_CR15","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1002\/(SICI)1097-0304(199708)41:4<392::AID-CCD8>3.0.CO;2-0","volume":"41","author":"JP Cheatham","year":"1997","unstructured":"Cheatham JP (1997) A wake-up call to those who dare to close the patent ductus arteriosus: Cardiologists, surgeons, FDA... are you listening? Cath Cardiovasc Diagn 41:392\u2013394","journal-title":"Cath Cardiovasc Diagn"}],"container-title":["Cardiovascular and Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s002709910019.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s002709910019\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s002709910019","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,4]],"date-time":"2023-04-04T19:58:07Z","timestamp":1680638287000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s002709910019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,3]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2000,3]]}},"alternative-id":["230200087"],"URL":"https:\/\/doi.org\/10.1007\/s002709910019","relation":{},"ISSN":["0174-1551","1432-086X"],"issn-type":[{"value":"0174-1551","type":"print"},{"value":"1432-086X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,3]]}}}